Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee
During the last few years considerable attention has been given to the use of gait analysis as a tool for clinical use. The instrumentation for measurement of the kinetics and kinematics of human locomotion was originally designed for research use. Extension of its use into the clinical field calls...
Gespeichert in:
Veröffentlicht in: | Prosthetics and orthotics international 1987-08, Vol.11 (2), p.55-64 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 64 |
---|---|
container_issue | 2 |
container_start_page | 55 |
container_title | Prosthetics and orthotics international |
container_volume | 11 |
creator | Zahedi, M. S. Spence, W. D. Solomonidis, S. E. Paul, J. P. |
description | During the last few years considerable attention has been given to the use of gait analysis as a tool for clinical use. The instrumentation for measurement of the kinetics and kinematics of human locomotion was originally designed for research use. Extension of its use into the clinical field calls for simplified methodology and clearly defined protocols with precise identification of the relevant parameters for the analysis. Force platforms, TV-computer and pylon transducer systems were used for collection of kinetic and kinematic data of five normal subjects, 10 below-knee, 10 above-knee and one hip disarticulation amputee. The repeatability tests showed significant differences in the measured parameters. These variations are attributed to the methodology of the analysis and the step to step variation of the subjects' gait. Differences in the degree of step to step variation between various amputee and normal subjects are quantified. In this presentation the capability of present day systems to perform repeatable gait measurements is discussed. A computational method for determination of representative measurements for the purposes of biomechanical evaluation and comparison as well as quantification of the degree of repeatability is described. |
doi_str_mv | 10.3109/03093648709078179 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_81041077</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.3109_03093648709078179</sage_id><sourcerecordid>81041077</sourcerecordid><originalsourceid>FETCH-LOGICAL-c430t-c7ffed510d48949bfbeeeaf61dc3b4dd0adc7c5ab370ebc4efa06fb33e3f41753</originalsourceid><addsrcrecordid>eNqNkE9r3DAQxUVJSTdpP0APAZ16czpCsmXRUwn9EwgESnssZiSNskoseyvJlHz7ertLL4GS08zw3u_BPMbeCriUAsx7kGBkp3oNBnQvtHnBNkKrrhFtK0_YZq83q6F7xc5KuQeQ2hg4Zaeya_tOmQ37-Y12hBVtHGN95HPgD3GiGh3Hyf_dE-6vRFiWTImmWnic-B3GyktdfKSyp-qW-Dj_pszHmCzHtFsq0Wv2MuBY6M1xnrMfnz99v_ra3Nx-ub76eNM4JaE2TodAvhXgVW-UscESEYZOeCet8h7QO-1atFIDWacoIHTBSkkyKKFbec7eHXJ3ef61UKlDisXROOJE81KGXoASoPVqFAejy3MpmcKwyzFhfhwEDPtKhyeVrszFMXyxifw_4tjhql8e9IJ3NNzPS57WX_8b-OEAxCnMOeGWcKxbh_lZ9B8O_5O0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81041077</pqid></control><display><type>article</type><title>Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee</title><source>MEDLINE</source><source>Access via Taylor & Francis</source><creator>Zahedi, M. S. ; Spence, W. D. ; Solomonidis, S. E. ; Paul, J. P.</creator><creatorcontrib>Zahedi, M. S. ; Spence, W. D. ; Solomonidis, S. E. ; Paul, J. P.</creatorcontrib><description>During the last few years considerable attention has been given to the use of gait analysis as a tool for clinical use. The instrumentation for measurement of the kinetics and kinematics of human locomotion was originally designed for research use. Extension of its use into the clinical field calls for simplified methodology and clearly defined protocols with precise identification of the relevant parameters for the analysis. Force platforms, TV-computer and pylon transducer systems were used for collection of kinetic and kinematic data of five normal subjects, 10 below-knee, 10 above-knee and one hip disarticulation amputee. The repeatability tests showed significant differences in the measured parameters. These variations are attributed to the methodology of the analysis and the step to step variation of the subjects' gait. Differences in the degree of step to step variation between various amputee and normal subjects are quantified. In this presentation the capability of present day systems to perform repeatable gait measurements is discussed. A computational method for determination of representative measurements for the purposes of biomechanical evaluation and comparison as well as quantification of the degree of repeatability is described.</description><identifier>ISSN: 0309-3646</identifier><identifier>EISSN: 1746-1553</identifier><identifier>DOI: 10.3109/03093648709078179</identifier><identifier>PMID: 3658649</identifier><language>eng</language><publisher>London, England: Informa UK Ltd</publisher><subject>Adult ; Aged ; Amputees ; Artificial Limbs ; Biomechanical Phenomena ; Gait ; Humans ; Kinetics ; Leg - surgery ; Middle Aged</subject><ispartof>Prosthetics and orthotics international, 1987-08, Vol.11 (2), p.55-64</ispartof><rights>1987 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 1987</rights><rights>1987 SAGE Publications</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c430t-c7ffed510d48949bfbeeeaf61dc3b4dd0adc7c5ab370ebc4efa06fb33e3f41753</citedby><cites>FETCH-LOGICAL-c430t-c7ffed510d48949bfbeeeaf61dc3b4dd0adc7c5ab370ebc4efa06fb33e3f41753</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.3109/03093648709078179$$EPDF$$P50$$Ginformahealthcare$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.3109/03093648709078179$$EHTML$$P50$$Ginformahealthcare$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,61221,61402</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/3658649$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zahedi, M. S.</creatorcontrib><creatorcontrib>Spence, W. D.</creatorcontrib><creatorcontrib>Solomonidis, S. E.</creatorcontrib><creatorcontrib>Paul, J. P.</creatorcontrib><title>Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee</title><title>Prosthetics and orthotics international</title><addtitle>Prosthet Orthot Int</addtitle><description>During the last few years considerable attention has been given to the use of gait analysis as a tool for clinical use. The instrumentation for measurement of the kinetics and kinematics of human locomotion was originally designed for research use. Extension of its use into the clinical field calls for simplified methodology and clearly defined protocols with precise identification of the relevant parameters for the analysis. Force platforms, TV-computer and pylon transducer systems were used for collection of kinetic and kinematic data of five normal subjects, 10 below-knee, 10 above-knee and one hip disarticulation amputee. The repeatability tests showed significant differences in the measured parameters. These variations are attributed to the methodology of the analysis and the step to step variation of the subjects' gait. Differences in the degree of step to step variation between various amputee and normal subjects are quantified. In this presentation the capability of present day systems to perform repeatable gait measurements is discussed. A computational method for determination of representative measurements for the purposes of biomechanical evaluation and comparison as well as quantification of the degree of repeatability is described.</description><subject>Adult</subject><subject>Aged</subject><subject>Amputees</subject><subject>Artificial Limbs</subject><subject>Biomechanical Phenomena</subject><subject>Gait</subject><subject>Humans</subject><subject>Kinetics</subject><subject>Leg - surgery</subject><subject>Middle Aged</subject><issn>0309-3646</issn><issn>1746-1553</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1987</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkE9r3DAQxUVJSTdpP0APAZ16czpCsmXRUwn9EwgESnssZiSNskoseyvJlHz7ertLL4GS08zw3u_BPMbeCriUAsx7kGBkp3oNBnQvtHnBNkKrrhFtK0_YZq83q6F7xc5KuQeQ2hg4Zaeya_tOmQ37-Y12hBVtHGN95HPgD3GiGh3Hyf_dE-6vRFiWTImmWnic-B3GyktdfKSyp-qW-Dj_pszHmCzHtFsq0Wv2MuBY6M1xnrMfnz99v_ra3Nx-ub76eNM4JaE2TodAvhXgVW-UscESEYZOeCet8h7QO-1atFIDWacoIHTBSkkyKKFbec7eHXJ3ef61UKlDisXROOJE81KGXoASoPVqFAejy3MpmcKwyzFhfhwEDPtKhyeVrszFMXyxifw_4tjhql8e9IJ3NNzPS57WX_8b-OEAxCnMOeGWcKxbh_lZ9B8O_5O0</recordid><startdate>19870801</startdate><enddate>19870801</enddate><creator>Zahedi, M. S.</creator><creator>Spence, W. D.</creator><creator>Solomonidis, S. E.</creator><creator>Paul, J. P.</creator><general>Informa UK Ltd</general><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19870801</creationdate><title>Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee</title><author>Zahedi, M. S. ; Spence, W. D. ; Solomonidis, S. E. ; Paul, J. P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c430t-c7ffed510d48949bfbeeeaf61dc3b4dd0adc7c5ab370ebc4efa06fb33e3f41753</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1987</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Amputees</topic><topic>Artificial Limbs</topic><topic>Biomechanical Phenomena</topic><topic>Gait</topic><topic>Humans</topic><topic>Kinetics</topic><topic>Leg - surgery</topic><topic>Middle Aged</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zahedi, M. S.</creatorcontrib><creatorcontrib>Spence, W. D.</creatorcontrib><creatorcontrib>Solomonidis, S. E.</creatorcontrib><creatorcontrib>Paul, J. P.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Prosthetics and orthotics international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zahedi, M. S.</au><au>Spence, W. D.</au><au>Solomonidis, S. E.</au><au>Paul, J. P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee</atitle><jtitle>Prosthetics and orthotics international</jtitle><addtitle>Prosthet Orthot Int</addtitle><date>1987-08-01</date><risdate>1987</risdate><volume>11</volume><issue>2</issue><spage>55</spage><epage>64</epage><pages>55-64</pages><issn>0309-3646</issn><eissn>1746-1553</eissn><abstract>During the last few years considerable attention has been given to the use of gait analysis as a tool for clinical use. The instrumentation for measurement of the kinetics and kinematics of human locomotion was originally designed for research use. Extension of its use into the clinical field calls for simplified methodology and clearly defined protocols with precise identification of the relevant parameters for the analysis. Force platforms, TV-computer and pylon transducer systems were used for collection of kinetic and kinematic data of five normal subjects, 10 below-knee, 10 above-knee and one hip disarticulation amputee. The repeatability tests showed significant differences in the measured parameters. These variations are attributed to the methodology of the analysis and the step to step variation of the subjects' gait. Differences in the degree of step to step variation between various amputee and normal subjects are quantified. In this presentation the capability of present day systems to perform repeatable gait measurements is discussed. A computational method for determination of representative measurements for the purposes of biomechanical evaluation and comparison as well as quantification of the degree of repeatability is described.</abstract><cop>London, England</cop><pub>Informa UK Ltd</pub><pmid>3658649</pmid><doi>10.3109/03093648709078179</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0309-3646 |
ispartof | Prosthetics and orthotics international, 1987-08, Vol.11 (2), p.55-64 |
issn | 0309-3646 1746-1553 |
language | eng |
recordid | cdi_proquest_miscellaneous_81041077 |
source | MEDLINE; Access via Taylor & Francis |
subjects | Adult Aged Amputees Artificial Limbs Biomechanical Phenomena Gait Humans Kinetics Leg - surgery Middle Aged |
title | Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T12%3A44%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Repeatability%20of%20kinetic%20and%20kinematic%20measurements%20in%20gait%20studies%20of%20the%20lower%20limb%20amputee&rft.jtitle=Prosthetics%20and%20orthotics%20international&rft.au=Zahedi,%20M.%20S.&rft.date=1987-08-01&rft.volume=11&rft.issue=2&rft.spage=55&rft.epage=64&rft.pages=55-64&rft.issn=0309-3646&rft.eissn=1746-1553&rft_id=info:doi/10.3109/03093648709078179&rft_dat=%3Cproquest_cross%3E81041077%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81041077&rft_id=info:pmid/3658649&rft_sage_id=10.3109_03093648709078179&rfr_iscdi=true |