Pressure measurements in the mammalian microvasculature

The servo nulling system for measuring pressures in the microvasculature system described by Wiederhielm was redesigned and utilized to measure pressures in the mammalian mesentric circulation, the hamster cheek pouch, and the rat cremaster muscle. A systems analysis of the components shows that dir...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Microvascular research 1970-04, Vol.2 (2), p.212-220
Hauptverfasser: Intaglietta, M., Pawula, R.F., Tompkins, W.R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 220
container_issue 2
container_start_page 212
container_title Microvascular research
container_volume 2
creator Intaglietta, M.
Pawula, R.F.
Tompkins, W.R.
description The servo nulling system for measuring pressures in the microvasculature system described by Wiederhielm was redesigned and utilized to measure pressures in the mammalian mesentric circulation, the hamster cheek pouch, and the rat cremaster muscle. A systems analysis of the components shows that direct-pressure measurements of suitable fidelity can be made with conventional transducers through microcannulas down to 10–15 μ diameter, and that for smaller diameters active systems are required. The system developed operates with a 25-Hz frequency response in the presence of routine electrical noise. Results obtained show that pressures in arterioles and venules in the mammalian mesenteric circulation are greater than the plasma colloidal osmotic pressure, while in corresponding vessels in muscle, venular pressures are lower than the colloidal osmotic pressure.
doi_str_mv 10.1016/0026-2862(70)90009-9
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80895917</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0026286270900099</els_id><sourcerecordid>80895917</sourcerecordid><originalsourceid>FETCH-LOGICAL-c272t-6360260967d188108a5ab076290eb6aa15146e93b0110c0dfa6cfaae9e20aa713</originalsourceid><addsrcrecordid>eNp9kE9LxDAQxYMo67r6DRR6Ej1UJ-k2bS6CLP6DBT3oOUzTKUaa7pq0C357U3fZo6eBmfdm3vwYO-dww4HLWwAhU1FKcVXAtQIAlaoDNuWg8lRlXB2y6V5yzE5C-ALgPFdiwiZ5LjIl5lNWvHkKYfCUOMKxOur6kNgu6T9jD53D1mKXOGv8aoPBDC32UXbKjhpsA53t6ox9PD68L57T5evTy-J-mRpRiD6VmYwRQMmi5mXJocQcKyikUECVROQ5n0tSWRWTgYG6QWkaRFIkALHg2Yxdbveu_ep7oNBrZ4OhtsWOVkPQJZQqV7yIwvlWGHOG4KnRa28d-h_NQY-89AhDjzB0AfqPl1bRdrHbP1SO6r1pByjO77Zzik9uLHkdjKXOUG09mV7XK_v_gV_zZ3kS</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80895917</pqid></control><display><type>article</type><title>Pressure measurements in the mammalian microvasculature</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Intaglietta, M. ; Pawula, R.F. ; Tompkins, W.R.</creator><creatorcontrib>Intaglietta, M. ; Pawula, R.F. ; Tompkins, W.R.</creatorcontrib><description>The servo nulling system for measuring pressures in the microvasculature system described by Wiederhielm was redesigned and utilized to measure pressures in the mammalian mesentric circulation, the hamster cheek pouch, and the rat cremaster muscle. A systems analysis of the components shows that direct-pressure measurements of suitable fidelity can be made with conventional transducers through microcannulas down to 10–15 μ diameter, and that for smaller diameters active systems are required. The system developed operates with a 25-Hz frequency response in the presence of routine electrical noise. Results obtained show that pressures in arterioles and venules in the mammalian mesenteric circulation are greater than the plasma colloidal osmotic pressure, while in corresponding vessels in muscle, venular pressures are lower than the colloidal osmotic pressure.</description><identifier>ISSN: 0026-2862</identifier><identifier>EISSN: 1095-9319</identifier><identifier>DOI: 10.1016/0026-2862(70)90009-9</identifier><identifier>PMID: 5523924</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Animals ; Blood Pressure Determination ; Catheterization ; Cats ; Cheek - blood supply ; Cricetinae ; Dogs ; Electronics ; Mesentery - blood supply ; Methods ; Microcirculation ; Muscles - blood supply ; Omentum - blood supply ; Rabbits ; Rats ; Transducers</subject><ispartof>Microvascular research, 1970-04, Vol.2 (2), p.212-220</ispartof><rights>1970</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c272t-6360260967d188108a5ab076290eb6aa15146e93b0110c0dfa6cfaae9e20aa713</citedby><cites>FETCH-LOGICAL-c272t-6360260967d188108a5ab076290eb6aa15146e93b0110c0dfa6cfaae9e20aa713</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0026-2862(70)90009-9$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/5523924$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Intaglietta, M.</creatorcontrib><creatorcontrib>Pawula, R.F.</creatorcontrib><creatorcontrib>Tompkins, W.R.</creatorcontrib><title>Pressure measurements in the mammalian microvasculature</title><title>Microvascular research</title><addtitle>Microvasc Res</addtitle><description>The servo nulling system for measuring pressures in the microvasculature system described by Wiederhielm was redesigned and utilized to measure pressures in the mammalian mesentric circulation, the hamster cheek pouch, and the rat cremaster muscle. A systems analysis of the components shows that direct-pressure measurements of suitable fidelity can be made with conventional transducers through microcannulas down to 10–15 μ diameter, and that for smaller diameters active systems are required. The system developed operates with a 25-Hz frequency response in the presence of routine electrical noise. Results obtained show that pressures in arterioles and venules in the mammalian mesenteric circulation are greater than the plasma colloidal osmotic pressure, while in corresponding vessels in muscle, venular pressures are lower than the colloidal osmotic pressure.</description><subject>Animals</subject><subject>Blood Pressure Determination</subject><subject>Catheterization</subject><subject>Cats</subject><subject>Cheek - blood supply</subject><subject>Cricetinae</subject><subject>Dogs</subject><subject>Electronics</subject><subject>Mesentery - blood supply</subject><subject>Methods</subject><subject>Microcirculation</subject><subject>Muscles - blood supply</subject><subject>Omentum - blood supply</subject><subject>Rabbits</subject><subject>Rats</subject><subject>Transducers</subject><issn>0026-2862</issn><issn>1095-9319</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1970</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE9LxDAQxYMo67r6DRR6Ej1UJ-k2bS6CLP6DBT3oOUzTKUaa7pq0C357U3fZo6eBmfdm3vwYO-dww4HLWwAhU1FKcVXAtQIAlaoDNuWg8lRlXB2y6V5yzE5C-ALgPFdiwiZ5LjIl5lNWvHkKYfCUOMKxOur6kNgu6T9jD53D1mKXOGv8aoPBDC32UXbKjhpsA53t6ox9PD68L57T5evTy-J-mRpRiD6VmYwRQMmi5mXJocQcKyikUECVROQ5n0tSWRWTgYG6QWkaRFIkALHg2Yxdbveu_ep7oNBrZ4OhtsWOVkPQJZQqV7yIwvlWGHOG4KnRa28d-h_NQY-89AhDjzB0AfqPl1bRdrHbP1SO6r1pByjO77Zzik9uLHkdjKXOUG09mV7XK_v_gV_zZ3kS</recordid><startdate>197004</startdate><enddate>197004</enddate><creator>Intaglietta, M.</creator><creator>Pawula, R.F.</creator><creator>Tompkins, W.R.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>197004</creationdate><title>Pressure measurements in the mammalian microvasculature</title><author>Intaglietta, M. ; Pawula, R.F. ; Tompkins, W.R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c272t-6360260967d188108a5ab076290eb6aa15146e93b0110c0dfa6cfaae9e20aa713</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1970</creationdate><topic>Animals</topic><topic>Blood Pressure Determination</topic><topic>Catheterization</topic><topic>Cats</topic><topic>Cheek - blood supply</topic><topic>Cricetinae</topic><topic>Dogs</topic><topic>Electronics</topic><topic>Mesentery - blood supply</topic><topic>Methods</topic><topic>Microcirculation</topic><topic>Muscles - blood supply</topic><topic>Omentum - blood supply</topic><topic>Rabbits</topic><topic>Rats</topic><topic>Transducers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Intaglietta, M.</creatorcontrib><creatorcontrib>Pawula, R.F.</creatorcontrib><creatorcontrib>Tompkins, W.R.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Microvascular research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Intaglietta, M.</au><au>Pawula, R.F.</au><au>Tompkins, W.R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pressure measurements in the mammalian microvasculature</atitle><jtitle>Microvascular research</jtitle><addtitle>Microvasc Res</addtitle><date>1970-04</date><risdate>1970</risdate><volume>2</volume><issue>2</issue><spage>212</spage><epage>220</epage><pages>212-220</pages><issn>0026-2862</issn><eissn>1095-9319</eissn><abstract>The servo nulling system for measuring pressures in the microvasculature system described by Wiederhielm was redesigned and utilized to measure pressures in the mammalian mesentric circulation, the hamster cheek pouch, and the rat cremaster muscle. A systems analysis of the components shows that direct-pressure measurements of suitable fidelity can be made with conventional transducers through microcannulas down to 10–15 μ diameter, and that for smaller diameters active systems are required. The system developed operates with a 25-Hz frequency response in the presence of routine electrical noise. Results obtained show that pressures in arterioles and venules in the mammalian mesenteric circulation are greater than the plasma colloidal osmotic pressure, while in corresponding vessels in muscle, venular pressures are lower than the colloidal osmotic pressure.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>5523924</pmid><doi>10.1016/0026-2862(70)90009-9</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0026-2862
ispartof Microvascular research, 1970-04, Vol.2 (2), p.212-220
issn 0026-2862
1095-9319
language eng
recordid cdi_proquest_miscellaneous_80895917
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Animals
Blood Pressure Determination
Catheterization
Cats
Cheek - blood supply
Cricetinae
Dogs
Electronics
Mesentery - blood supply
Methods
Microcirculation
Muscles - blood supply
Omentum - blood supply
Rabbits
Rats
Transducers
title Pressure measurements in the mammalian microvasculature
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T19%3A15%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pressure%20measurements%20in%20the%20mammalian%20microvasculature&rft.jtitle=Microvascular%20research&rft.au=Intaglietta,%20M.&rft.date=1970-04&rft.volume=2&rft.issue=2&rft.spage=212&rft.epage=220&rft.pages=212-220&rft.issn=0026-2862&rft.eissn=1095-9319&rft_id=info:doi/10.1016/0026-2862(70)90009-9&rft_dat=%3Cproquest_cross%3E80895917%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80895917&rft_id=info:pmid/5523924&rft_els_id=0026286270900099&rfr_iscdi=true