Plasma Compatibility of Injectables: Comparison of Intravenous U-74006F, a 21-Aminosteroid Antioxidant, with Dilantin Brand of Parenteral Phenytoin
The 21-aminosteroid antioxidant U-74006F (1) is being developed as an iv injectable agent for the treatment of human CNS trauma and ischemia. Because of its poor water solubility, the plasma compatibility of the parenteral formulation of 1 was evaluated using three models: (I) static solubility, (II...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical sciences 1991-04, Vol.80 (4), p.371-375 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The 21-aminosteroid antioxidant U-74006F (1) is being developed as an iv injectable agent for the treatment of human CNS trauma and ischemia. Because of its poor water solubility, the plasma compatibility of the parenteral formulation of 1 was evaluated using three models: (I) static solubility, (II) aggregometric, and (III) dynamic flow. The flow model was designed to mimic an iv infusion into the human antecubital vein, which was assumed to have plasma flow of 10 mL/min. Dilantin (phenytoin), the positive control, produced a precipitate in all three models from a 10% (v/v) mixture with human plasma, which approximates the in vivo ratio when the drug is infused at the recommended rate of 1 mL/min. Approximately 39% of the phenytoin dose in the flow model was retained on a downstream 3-μm filter as crystals. In comparison, the parenteral formulation of 1 produced minimal precipitate in models I and II from 40% mixtures with plasma, but higher percentages produced unstable suspensions with time-dependent precipitation. The percentage of the dose of the parenteral formulation of 1 retained on the filter in the flow model was 0.5% or less at infusion rates as high as 10 mL/min and 3% at 19 mL/min. At the 10-mL/min infusion rate, the mass of 1 retained on the filter per minute was |
---|---|
ISSN: | 0022-3549 1520-6017 |
DOI: | 10.1002/jps.2600800418 |