Disposable Endoscopic Biopsy Forceps: Comparison with Standard Forceps of Sample Size and Adequacy of Specimen

Disposable biopsy forceps have recently been introduced into the field of endoscopy. We have analyzed biopsy size and histologic interpretation of samples obtained with the disposable forceps and compared them to those obtained with reusable forceps. In the 18 patients studied, 49 samples were colle...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical gastroenterology 1991-02, Vol.13 (1), p.76-78
Hauptverfasser: Turk, D J, Kozarek, R A, Botoman, V A, Patterson, D J, Ball, T J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 78
container_issue 1
container_start_page 76
container_title Journal of clinical gastroenterology
container_volume 13
creator Turk, D J
Kozarek, R A
Botoman, V A
Patterson, D J
Ball, T J
description Disposable biopsy forceps have recently been introduced into the field of endoscopy. We have analyzed biopsy size and histologic interpretation of samples obtained with the disposable forceps and compared them to those obtained with reusable forceps. In the 18 patients studied, 49 samples were collected with the reusable forceps and 47 samples with the disposable. Biopsy sites included the colorectum in 50%, esophagus in 22%, small bowel in 17%, and stomach in 11% of the patients. We found that statistically smaller samples were collected by the disposable biopsy forceps than by the reusable (2.48 ± 1.11 mm versus 1.99 ± 0.55 mm, p = 0.006). The smaller biopsy size with disposable forceps was not clinically important since all but one of 47 specimens were interpreted as adequate for histologic diagnosis. The convenience, potential cost savings, and prevention of the spread of communicable agents afforded by disposable biopsy forceps make them a possible alternative to conventional forceps in some clinical settings.
doi_str_mv 10.1097/00004836-199102000-00016
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80485145</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80485145</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3006-f37c19fbccb0ba6730721c838d42480b3e7359f7ea97d4793ca907c24196e0c73</originalsourceid><addsrcrecordid>eNp1kctq3DAUhkVpSCdJH6GgVXdOjyzbsrqbTpM2EMhikrWQ5WNGrW1pJJth8vRVMpddBUIc_suBT4RQBrcMpPgG6RQ1rzImJYM8TVm6rPpAFqzkMsuBs49kAUzmGQgJn8hVjH-SQ3DOLsllSghRwoKMP230LuqmR3o3ti4a562hP6zzcU_vXTDo43e6coPXwUY30p2dNnQ96bHVoT05qOvoWg8-taztK9Kk0mWL21mb_bvm0dgBxxty0ek-4ufje01e7u-eV7-zx6dfD6vlY2Y4QJV1XBgmu8aYBhpdCQ4iZ6bmdVvkRQ0NR8FL2QnUUrSFkNxoCcLkBZMVghH8mnw99PrgtjPGSQ02Gux7PaKbo6oTvZIVZTLWB6MJLsaAnfLBDjrsFQP1hlqdUKszavWOOkW_HHfMzYDtOXhkm_TioO9cP2GIf_t5h0FtUPfTRv3vB_k_SgiI2Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80485145</pqid></control><display><type>article</type><title>Disposable Endoscopic Biopsy Forceps: Comparison with Standard Forceps of Sample Size and Adequacy of Specimen</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Turk, D J ; Kozarek, R A ; Botoman, V A ; Patterson, D J ; Ball, T J</creator><creatorcontrib>Turk, D J ; Kozarek, R A ; Botoman, V A ; Patterson, D J ; Ball, T J</creatorcontrib><description>Disposable biopsy forceps have recently been introduced into the field of endoscopy. We have analyzed biopsy size and histologic interpretation of samples obtained with the disposable forceps and compared them to those obtained with reusable forceps. In the 18 patients studied, 49 samples were collected with the reusable forceps and 47 samples with the disposable. Biopsy sites included the colorectum in 50%, esophagus in 22%, small bowel in 17%, and stomach in 11% of the patients. We found that statistically smaller samples were collected by the disposable biopsy forceps than by the reusable (2.48 ± 1.11 mm versus 1.99 ± 0.55 mm, p = 0.006). The smaller biopsy size with disposable forceps was not clinically important since all but one of 47 specimens were interpreted as adequate for histologic diagnosis. The convenience, potential cost savings, and prevention of the spread of communicable agents afforded by disposable biopsy forceps make them a possible alternative to conventional forceps in some clinical settings.</description><identifier>ISSN: 0192-0790</identifier><identifier>EISSN: 1539-2031</identifier><identifier>DOI: 10.1097/00004836-199102000-00016</identifier><identifier>PMID: 2007750</identifier><language>eng</language><publisher>United States: Lippincott-Raven Publishers</publisher><subject>Adult ; Aged ; Aged, 80 and over ; Biopsy - instrumentation ; Disposable Equipment ; Endoscopy, Digestive System - instrumentation ; Humans ; Middle Aged</subject><ispartof>Journal of clinical gastroenterology, 1991-02, Vol.13 (1), p.76-78</ispartof><rights>Lippincott-Raven Publishers.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2007750$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Turk, D J</creatorcontrib><creatorcontrib>Kozarek, R A</creatorcontrib><creatorcontrib>Botoman, V A</creatorcontrib><creatorcontrib>Patterson, D J</creatorcontrib><creatorcontrib>Ball, T J</creatorcontrib><title>Disposable Endoscopic Biopsy Forceps: Comparison with Standard Forceps of Sample Size and Adequacy of Specimen</title><title>Journal of clinical gastroenterology</title><addtitle>J Clin Gastroenterol</addtitle><description>Disposable biopsy forceps have recently been introduced into the field of endoscopy. We have analyzed biopsy size and histologic interpretation of samples obtained with the disposable forceps and compared them to those obtained with reusable forceps. In the 18 patients studied, 49 samples were collected with the reusable forceps and 47 samples with the disposable. Biopsy sites included the colorectum in 50%, esophagus in 22%, small bowel in 17%, and stomach in 11% of the patients. We found that statistically smaller samples were collected by the disposable biopsy forceps than by the reusable (2.48 ± 1.11 mm versus 1.99 ± 0.55 mm, p = 0.006). The smaller biopsy size with disposable forceps was not clinically important since all but one of 47 specimens were interpreted as adequate for histologic diagnosis. The convenience, potential cost savings, and prevention of the spread of communicable agents afforded by disposable biopsy forceps make them a possible alternative to conventional forceps in some clinical settings.</description><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Biopsy - instrumentation</subject><subject>Disposable Equipment</subject><subject>Endoscopy, Digestive System - instrumentation</subject><subject>Humans</subject><subject>Middle Aged</subject><issn>0192-0790</issn><issn>1539-2031</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1991</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kctq3DAUhkVpSCdJH6GgVXdOjyzbsrqbTpM2EMhikrWQ5WNGrW1pJJth8vRVMpddBUIc_suBT4RQBrcMpPgG6RQ1rzImJYM8TVm6rPpAFqzkMsuBs49kAUzmGQgJn8hVjH-SQ3DOLsllSghRwoKMP230LuqmR3o3ti4a562hP6zzcU_vXTDo43e6coPXwUY30p2dNnQ96bHVoT05qOvoWg8-taztK9Kk0mWL21mb_bvm0dgBxxty0ek-4ufje01e7u-eV7-zx6dfD6vlY2Y4QJV1XBgmu8aYBhpdCQ4iZ6bmdVvkRQ0NR8FL2QnUUrSFkNxoCcLkBZMVghH8mnw99PrgtjPGSQ02Gux7PaKbo6oTvZIVZTLWB6MJLsaAnfLBDjrsFQP1hlqdUKszavWOOkW_HHfMzYDtOXhkm_TioO9cP2GIf_t5h0FtUPfTRv3vB_k_SgiI2Q</recordid><startdate>199102</startdate><enddate>199102</enddate><creator>Turk, D J</creator><creator>Kozarek, R A</creator><creator>Botoman, V A</creator><creator>Patterson, D J</creator><creator>Ball, T J</creator><general>Lippincott-Raven Publishers</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>8BM</scope></search><sort><creationdate>199102</creationdate><title>Disposable Endoscopic Biopsy Forceps: Comparison with Standard Forceps of Sample Size and Adequacy of Specimen</title><author>Turk, D J ; Kozarek, R A ; Botoman, V A ; Patterson, D J ; Ball, T J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3006-f37c19fbccb0ba6730721c838d42480b3e7359f7ea97d4793ca907c24196e0c73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1991</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Biopsy - instrumentation</topic><topic>Disposable Equipment</topic><topic>Endoscopy, Digestive System - instrumentation</topic><topic>Humans</topic><topic>Middle Aged</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Turk, D J</creatorcontrib><creatorcontrib>Kozarek, R A</creatorcontrib><creatorcontrib>Botoman, V A</creatorcontrib><creatorcontrib>Patterson, D J</creatorcontrib><creatorcontrib>Ball, T J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>ComDisDome</collection><jtitle>Journal of clinical gastroenterology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Turk, D J</au><au>Kozarek, R A</au><au>Botoman, V A</au><au>Patterson, D J</au><au>Ball, T J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Disposable Endoscopic Biopsy Forceps: Comparison with Standard Forceps of Sample Size and Adequacy of Specimen</atitle><jtitle>Journal of clinical gastroenterology</jtitle><addtitle>J Clin Gastroenterol</addtitle><date>1991-02</date><risdate>1991</risdate><volume>13</volume><issue>1</issue><spage>76</spage><epage>78</epage><pages>76-78</pages><issn>0192-0790</issn><eissn>1539-2031</eissn><abstract>Disposable biopsy forceps have recently been introduced into the field of endoscopy. We have analyzed biopsy size and histologic interpretation of samples obtained with the disposable forceps and compared them to those obtained with reusable forceps. In the 18 patients studied, 49 samples were collected with the reusable forceps and 47 samples with the disposable. Biopsy sites included the colorectum in 50%, esophagus in 22%, small bowel in 17%, and stomach in 11% of the patients. We found that statistically smaller samples were collected by the disposable biopsy forceps than by the reusable (2.48 ± 1.11 mm versus 1.99 ± 0.55 mm, p = 0.006). The smaller biopsy size with disposable forceps was not clinically important since all but one of 47 specimens were interpreted as adequate for histologic diagnosis. The convenience, potential cost savings, and prevention of the spread of communicable agents afforded by disposable biopsy forceps make them a possible alternative to conventional forceps in some clinical settings.</abstract><cop>United States</cop><pub>Lippincott-Raven Publishers</pub><pmid>2007750</pmid><doi>10.1097/00004836-199102000-00016</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0192-0790
ispartof Journal of clinical gastroenterology, 1991-02, Vol.13 (1), p.76-78
issn 0192-0790
1539-2031
language eng
recordid cdi_proquest_miscellaneous_80485145
source MEDLINE; Journals@Ovid Complete
subjects Adult
Aged
Aged, 80 and over
Biopsy - instrumentation
Disposable Equipment
Endoscopy, Digestive System - instrumentation
Humans
Middle Aged
title Disposable Endoscopic Biopsy Forceps: Comparison with Standard Forceps of Sample Size and Adequacy of Specimen
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T20%3A48%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Disposable%20Endoscopic%20Biopsy%20Forceps:%20Comparison%20with%20Standard%20Forceps%20of%20Sample%20Size%20and%20Adequacy%20of%20Specimen&rft.jtitle=Journal%20of%20clinical%20gastroenterology&rft.au=Turk,%20D%20J&rft.date=1991-02&rft.volume=13&rft.issue=1&rft.spage=76&rft.epage=78&rft.pages=76-78&rft.issn=0192-0790&rft.eissn=1539-2031&rft_id=info:doi/10.1097/00004836-199102000-00016&rft_dat=%3Cproquest_cross%3E80485145%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80485145&rft_id=info:pmid/2007750&rfr_iscdi=true