Failure properties of passive human aortic tissue. II—Biaxial tension tests

Descending mid-thoracic aortas were obtained from 16 autopsies and biaxial inflation tests performed on the tissue at dynamic (∼20 s −1) and quasi-static (∼0.01 s −1) strain rates. A bubble inflation technique was developed for this purpose. Extension histories of the specimens were recorded photogr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomechanics 1983, Vol.16 (1), p.31,39-37,44
Hauptverfasser: Mohan, Dinesh, Melvin, John W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Descending mid-thoracic aortas were obtained from 16 autopsies and biaxial inflation tests performed on the tissue at dynamic (∼20 s −1) and quasi-static (∼0.01 s −1) strain rates. A bubble inflation technique was developed for this purpose. Extension histories of the specimens were recorded photographically and values of ultimate stresses and extension ratios in biaxial stretch have been calculated. Under conditions of uniform biaxial stretch the tissue consistently failed in a direction perpendicular to the long axis of the aorta and pressure values at failure were greater by a factor of two in the dynamic tests than those in the quasi-static tests.
ISSN:0021-9290