Column-switching high-performance liquid chromatographic (HPLC) determination of hydrochlorothiazide in rat, dog, and human plasma

A fully automated HPLC assay for hydrochlorothiazide in plasma has been developed using a column-switching technique. The method involves direct injection of plasma to the extraction column for sample cleanup followed by switching onto the analytical column. Good precision, accuracy, and linearity w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pharmaceutical research 1990-12, Vol.7 (12), p.1257-1261
Hauptverfasser: BE-SHENG KUO, MANDAGERE, A, OSBORNE, D. R, KIN-KAI HWANG
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1261
container_issue 12
container_start_page 1257
container_title Pharmaceutical research
container_volume 7
creator BE-SHENG KUO
MANDAGERE, A
OSBORNE, D. R
KIN-KAI HWANG
description A fully automated HPLC assay for hydrochlorothiazide in plasma has been developed using a column-switching technique. The method involves direct injection of plasma to the extraction column for sample cleanup followed by switching onto the analytical column. Good precision, accuracy, and linearity were obtained over a range of 25 to 2000 ng/ml in rat, dog, and human plasma. The column-switching method has also been validated by comparison with a conventional HPLC method requiring a cumbersome plasma extraction procedure. Since the method is simple, rapid, and reproducible, it is useful for determination of hydrochlorothiazide levels in animal and human plasma.
doi_str_mv 10.1023/A:1015933820971
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_80342024</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80342024</sourcerecordid><originalsourceid>FETCH-LOGICAL-p236t-f20dddb2278d0f650ebe6387d6ca37532401373790285f72f7e8fb6e9698c57d3</originalsourceid><addsrcrecordid>eNo9kE1LwzAAhoMoc07PnoRcFIVV89E2qbdR1AkDPSh4K1k-lkjbdEmLzKO_3ILD03t4H57DA8A5RrcYEXq3uMcIZwWlnKCC4QMwxRmjSYHSj0MwRYykCWcpPgYnMX4ihDgu0gmYjHCW5XQKfkpfD02bxC_XS-vaDbRuY5NOB-NDI1qpYe22g1NQ2uAb0ftNEJ11El4vX1flDVS616Fxreidb6E30O5U8NLWPvjeOvHtlIauhUH0c6j8Zg5Fq6AdRjfsahEbcQqOjKijPtvvDLw_PryVy2T18vRcLlZJR2jeJ4YgpdSaEMYVMnmG9FrnlDOVS0FZRkmKMGWUFYjwzDBimOZmnesiL7jMmKIzcPXn7YLfDjr2VeOi1HUtWu2HWHFEU4JIOoIXe3BYN1pVXXCNCLtqH238L_e_iFLUJoyZXPzHxsKYMIbpLzxqfKw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80342024</pqid></control><display><type>article</type><title>Column-switching high-performance liquid chromatographic (HPLC) determination of hydrochlorothiazide in rat, dog, and human plasma</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>BE-SHENG KUO ; MANDAGERE, A ; OSBORNE, D. R ; KIN-KAI HWANG</creator><creatorcontrib>BE-SHENG KUO ; MANDAGERE, A ; OSBORNE, D. R ; KIN-KAI HWANG</creatorcontrib><description>A fully automated HPLC assay for hydrochlorothiazide in plasma has been developed using a column-switching technique. The method involves direct injection of plasma to the extraction column for sample cleanup followed by switching onto the analytical column. Good precision, accuracy, and linearity were obtained over a range of 25 to 2000 ng/ml in rat, dog, and human plasma. The column-switching method has also been validated by comparison with a conventional HPLC method requiring a cumbersome plasma extraction procedure. Since the method is simple, rapid, and reproducible, it is useful for determination of hydrochlorothiazide levels in animal and human plasma.</description><identifier>ISSN: 0724-8741</identifier><identifier>EISSN: 1573-904X</identifier><identifier>DOI: 10.1023/A:1015933820971</identifier><identifier>PMID: 2095563</identifier><identifier>CODEN: PHREEB</identifier><language>eng</language><publisher>New York, NY: Springer</publisher><subject>Analysis ; Animals ; Biological and medical sciences ; Chromatography, High Pressure Liquid - methods ; Chromatography, High Pressure Liquid - standards ; Dogs ; Evaluation Studies as Topic ; General pharmacology ; Humans ; Hydrochlorothiazide - blood ; Medical sciences ; Pharmacology. Drug treatments ; Rats</subject><ispartof>Pharmaceutical research, 1990-12, Vol.7 (12), p.1257-1261</ispartof><rights>1991 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27906,27907</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=19412771$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2095563$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>BE-SHENG KUO</creatorcontrib><creatorcontrib>MANDAGERE, A</creatorcontrib><creatorcontrib>OSBORNE, D. R</creatorcontrib><creatorcontrib>KIN-KAI HWANG</creatorcontrib><title>Column-switching high-performance liquid chromatographic (HPLC) determination of hydrochlorothiazide in rat, dog, and human plasma</title><title>Pharmaceutical research</title><addtitle>Pharm Res</addtitle><description>A fully automated HPLC assay for hydrochlorothiazide in plasma has been developed using a column-switching technique. The method involves direct injection of plasma to the extraction column for sample cleanup followed by switching onto the analytical column. Good precision, accuracy, and linearity were obtained over a range of 25 to 2000 ng/ml in rat, dog, and human plasma. The column-switching method has also been validated by comparison with a conventional HPLC method requiring a cumbersome plasma extraction procedure. Since the method is simple, rapid, and reproducible, it is useful for determination of hydrochlorothiazide levels in animal and human plasma.</description><subject>Analysis</subject><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Chromatography, High Pressure Liquid - standards</subject><subject>Dogs</subject><subject>Evaluation Studies as Topic</subject><subject>General pharmacology</subject><subject>Humans</subject><subject>Hydrochlorothiazide - blood</subject><subject>Medical sciences</subject><subject>Pharmacology. Drug treatments</subject><subject>Rats</subject><issn>0724-8741</issn><issn>1573-904X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kE1LwzAAhoMoc07PnoRcFIVV89E2qbdR1AkDPSh4K1k-lkjbdEmLzKO_3ILD03t4H57DA8A5RrcYEXq3uMcIZwWlnKCC4QMwxRmjSYHSj0MwRYykCWcpPgYnMX4ihDgu0gmYjHCW5XQKfkpfD02bxC_XS-vaDbRuY5NOB-NDI1qpYe22g1NQ2uAb0ftNEJ11El4vX1flDVS616Fxreidb6E30O5U8NLWPvjeOvHtlIauhUH0c6j8Zg5Fq6AdRjfsahEbcQqOjKijPtvvDLw_PryVy2T18vRcLlZJR2jeJ4YgpdSaEMYVMnmG9FrnlDOVS0FZRkmKMGWUFYjwzDBimOZmnesiL7jMmKIzcPXn7YLfDjr2VeOi1HUtWu2HWHFEU4JIOoIXe3BYN1pVXXCNCLtqH238L_e_iFLUJoyZXPzHxsKYMIbpLzxqfKw</recordid><startdate>19901201</startdate><enddate>19901201</enddate><creator>BE-SHENG KUO</creator><creator>MANDAGERE, A</creator><creator>OSBORNE, D. R</creator><creator>KIN-KAI HWANG</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>19901201</creationdate><title>Column-switching high-performance liquid chromatographic (HPLC) determination of hydrochlorothiazide in rat, dog, and human plasma</title><author>BE-SHENG KUO ; MANDAGERE, A ; OSBORNE, D. R ; KIN-KAI HWANG</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p236t-f20dddb2278d0f650ebe6387d6ca37532401373790285f72f7e8fb6e9698c57d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Analysis</topic><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Chromatography, High Pressure Liquid - standards</topic><topic>Dogs</topic><topic>Evaluation Studies as Topic</topic><topic>General pharmacology</topic><topic>Humans</topic><topic>Hydrochlorothiazide - blood</topic><topic>Medical sciences</topic><topic>Pharmacology. Drug treatments</topic><topic>Rats</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>BE-SHENG KUO</creatorcontrib><creatorcontrib>MANDAGERE, A</creatorcontrib><creatorcontrib>OSBORNE, D. R</creatorcontrib><creatorcontrib>KIN-KAI HWANG</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Pharmaceutical research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>BE-SHENG KUO</au><au>MANDAGERE, A</au><au>OSBORNE, D. R</au><au>KIN-KAI HWANG</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Column-switching high-performance liquid chromatographic (HPLC) determination of hydrochlorothiazide in rat, dog, and human plasma</atitle><jtitle>Pharmaceutical research</jtitle><addtitle>Pharm Res</addtitle><date>1990-12-01</date><risdate>1990</risdate><volume>7</volume><issue>12</issue><spage>1257</spage><epage>1261</epage><pages>1257-1261</pages><issn>0724-8741</issn><eissn>1573-904X</eissn><coden>PHREEB</coden><abstract>A fully automated HPLC assay for hydrochlorothiazide in plasma has been developed using a column-switching technique. The method involves direct injection of plasma to the extraction column for sample cleanup followed by switching onto the analytical column. Good precision, accuracy, and linearity were obtained over a range of 25 to 2000 ng/ml in rat, dog, and human plasma. The column-switching method has also been validated by comparison with a conventional HPLC method requiring a cumbersome plasma extraction procedure. Since the method is simple, rapid, and reproducible, it is useful for determination of hydrochlorothiazide levels in animal and human plasma.</abstract><cop>New York, NY</cop><pub>Springer</pub><pmid>2095563</pmid><doi>10.1023/A:1015933820971</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0724-8741
ispartof Pharmaceutical research, 1990-12, Vol.7 (12), p.1257-1261
issn 0724-8741
1573-904X
language eng
recordid cdi_proquest_miscellaneous_80342024
source MEDLINE; SpringerLink Journals - AutoHoldings
subjects Analysis
Animals
Biological and medical sciences
Chromatography, High Pressure Liquid - methods
Chromatography, High Pressure Liquid - standards
Dogs
Evaluation Studies as Topic
General pharmacology
Humans
Hydrochlorothiazide - blood
Medical sciences
Pharmacology. Drug treatments
Rats
title Column-switching high-performance liquid chromatographic (HPLC) determination of hydrochlorothiazide in rat, dog, and human plasma
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T10%3A54%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Column-switching%20high-performance%20liquid%20chromatographic%20(HPLC)%20determination%20of%20hydrochlorothiazide%20in%20rat,%20dog,%20and%20human%20plasma&rft.jtitle=Pharmaceutical%20research&rft.au=BE-SHENG%20KUO&rft.date=1990-12-01&rft.volume=7&rft.issue=12&rft.spage=1257&rft.epage=1261&rft.pages=1257-1261&rft.issn=0724-8741&rft.eissn=1573-904X&rft.coden=PHREEB&rft_id=info:doi/10.1023/A:1015933820971&rft_dat=%3Cproquest_pubme%3E80342024%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80342024&rft_id=info:pmid/2095563&rfr_iscdi=true