Clinical experience with the Nimbus pump

The Nimbus pump is an indwelling, electromagnetic powered left ventricular (LV) assist device inserted transfemorally. The inflow cannula (7 mm) is positioned across the aortic valve and the pump in the descending aorta. Indications for insertion include cardiogenic shock despite maximal medical sup...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ASAIO transactions 1990-07, Vol.36 (3), p.M632-M636
Hauptverfasser: Deeb, G M, Bolling, S F, Nicklas, J, Walsh, R S, Steimle, C N, Shea, M J, Meagher, J S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page M636
container_issue 3
container_start_page M632
container_title ASAIO transactions
container_volume 36
creator Deeb, G M
Bolling, S F
Nicklas, J
Walsh, R S
Steimle, C N
Shea, M J
Meagher, J S
description The Nimbus pump is an indwelling, electromagnetic powered left ventricular (LV) assist device inserted transfemorally. The inflow cannula (7 mm) is positioned across the aortic valve and the pump in the descending aorta. Indications for insertion include cardiogenic shock despite maximal medical support and PCWP greater than 18 mmHg, MAP less than 90 mmHg, and Cl less than 2 L/min/m2. Twelve patients underwent the attempt at surgical insertion of the Nimbus pump. Diagnoses included eight acute myocardial infarctions (AMI), two ischemic cardiomyopathy, one postpartum cardiomyopathy, and one transplanted heart rejection. Eight (67%) of twelve patients had successful insertion. One patient had peripheral vascular disease preventing passage, and three had femoral vessels too small for insertion (less than 7.5 Hagar dilator). Five patients with the diagnosis of AMI had successful insertion and three (60%) underwent sufficient LV recovery for removal of the device; the other two patients died of stroke and ventricular arrhythmias, respectively. Three patients with the diagnosis of cardiomyopathy had progression of the disease process, and their needs exceeded the capabilities of the pump and they died of multiorgan failure. The Nimbus pump is an attractive LV assist device because of its pumping capacity (3.5 L/min) and minor surgical procedure for insertion. However, its application is limited because of access route and size. The device appears to work well for patients in cardiogenic shock after AMI (60% recovery) but does not appear indicated for patients with cadiomyopathy.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_80154172</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80154172</sourcerecordid><originalsourceid>FETCH-LOGICAL-p121t-8ef8601e3dbf8f1123ce5dfe8a4b116642162079683cd06ac14152918466c2803</originalsourceid><addsrcrecordid>eNotj01LxDAUAHNQ1nX1Jwg5iZfCe0mbpEcpfiwsetFzSdNXNtJ0Y9Og_nsFe5rLMDBnbAvG1IXGGi7YZUofAFJqwA3bCFEJrWHL7prRT97ZkdN3pNnT5Ih_-eXIlyPxFx-6nHjMIV6x88GOia5X7tj748Nb81wcXp_2zf2hiChwKQwNRgGS7LvBDIhCOqr6gYwtO0SlSoFKgK6Vka4HZR2WWIkaTamUEwbkjt3-d-N8-syUljb45Ggc7USnnFoDWJWoxZ94s4q5C9S3cfbBzj_tuiZ_AQOdRwg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80154172</pqid></control><display><type>article</type><title>Clinical experience with the Nimbus pump</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Deeb, G M ; Bolling, S F ; Nicklas, J ; Walsh, R S ; Steimle, C N ; Shea, M J ; Meagher, J S</creator><creatorcontrib>Deeb, G M ; Bolling, S F ; Nicklas, J ; Walsh, R S ; Steimle, C N ; Shea, M J ; Meagher, J S</creatorcontrib><description>The Nimbus pump is an indwelling, electromagnetic powered left ventricular (LV) assist device inserted transfemorally. The inflow cannula (7 mm) is positioned across the aortic valve and the pump in the descending aorta. Indications for insertion include cardiogenic shock despite maximal medical support and PCWP greater than 18 mmHg, MAP less than 90 mmHg, and Cl less than 2 L/min/m2. Twelve patients underwent the attempt at surgical insertion of the Nimbus pump. Diagnoses included eight acute myocardial infarctions (AMI), two ischemic cardiomyopathy, one postpartum cardiomyopathy, and one transplanted heart rejection. Eight (67%) of twelve patients had successful insertion. One patient had peripheral vascular disease preventing passage, and three had femoral vessels too small for insertion (less than 7.5 Hagar dilator). Five patients with the diagnosis of AMI had successful insertion and three (60%) underwent sufficient LV recovery for removal of the device; the other two patients died of stroke and ventricular arrhythmias, respectively. Three patients with the diagnosis of cardiomyopathy had progression of the disease process, and their needs exceeded the capabilities of the pump and they died of multiorgan failure. The Nimbus pump is an attractive LV assist device because of its pumping capacity (3.5 L/min) and minor surgical procedure for insertion. However, its application is limited because of access route and size. The device appears to work well for patients in cardiogenic shock after AMI (60% recovery) but does not appear indicated for patients with cadiomyopathy.</description><identifier>ISSN: 0889-7190</identifier><identifier>PMID: 2252770</identifier><language>eng</language><publisher>United States</publisher><subject>Adult ; Aged ; Cardiac Output - physiology ; Cardiomyopathies - therapy ; Equipment Design ; Female ; Follow-Up Studies ; Heart Transplantation - instrumentation ; Heart-Assist Devices ; Humans ; Male ; Middle Aged ; Myocardial Infarction - therapy ; Postoperative Complications - therapy ; Shock, Cardiogenic - therapy</subject><ispartof>ASAIO transactions, 1990-07, Vol.36 (3), p.M632-M636</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2252770$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Deeb, G M</creatorcontrib><creatorcontrib>Bolling, S F</creatorcontrib><creatorcontrib>Nicklas, J</creatorcontrib><creatorcontrib>Walsh, R S</creatorcontrib><creatorcontrib>Steimle, C N</creatorcontrib><creatorcontrib>Shea, M J</creatorcontrib><creatorcontrib>Meagher, J S</creatorcontrib><title>Clinical experience with the Nimbus pump</title><title>ASAIO transactions</title><addtitle>ASAIO Trans</addtitle><description>The Nimbus pump is an indwelling, electromagnetic powered left ventricular (LV) assist device inserted transfemorally. The inflow cannula (7 mm) is positioned across the aortic valve and the pump in the descending aorta. Indications for insertion include cardiogenic shock despite maximal medical support and PCWP greater than 18 mmHg, MAP less than 90 mmHg, and Cl less than 2 L/min/m2. Twelve patients underwent the attempt at surgical insertion of the Nimbus pump. Diagnoses included eight acute myocardial infarctions (AMI), two ischemic cardiomyopathy, one postpartum cardiomyopathy, and one transplanted heart rejection. Eight (67%) of twelve patients had successful insertion. One patient had peripheral vascular disease preventing passage, and three had femoral vessels too small for insertion (less than 7.5 Hagar dilator). Five patients with the diagnosis of AMI had successful insertion and three (60%) underwent sufficient LV recovery for removal of the device; the other two patients died of stroke and ventricular arrhythmias, respectively. Three patients with the diagnosis of cardiomyopathy had progression of the disease process, and their needs exceeded the capabilities of the pump and they died of multiorgan failure. The Nimbus pump is an attractive LV assist device because of its pumping capacity (3.5 L/min) and minor surgical procedure for insertion. However, its application is limited because of access route and size. The device appears to work well for patients in cardiogenic shock after AMI (60% recovery) but does not appear indicated for patients with cadiomyopathy.</description><subject>Adult</subject><subject>Aged</subject><subject>Cardiac Output - physiology</subject><subject>Cardiomyopathies - therapy</subject><subject>Equipment Design</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Heart Transplantation - instrumentation</subject><subject>Heart-Assist Devices</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Myocardial Infarction - therapy</subject><subject>Postoperative Complications - therapy</subject><subject>Shock, Cardiogenic - therapy</subject><issn>0889-7190</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNotj01LxDAUAHNQ1nX1Jwg5iZfCe0mbpEcpfiwsetFzSdNXNtJ0Y9Og_nsFe5rLMDBnbAvG1IXGGi7YZUofAFJqwA3bCFEJrWHL7prRT97ZkdN3pNnT5Ih_-eXIlyPxFx-6nHjMIV6x88GOia5X7tj748Nb81wcXp_2zf2hiChwKQwNRgGS7LvBDIhCOqr6gYwtO0SlSoFKgK6Vka4HZR2WWIkaTamUEwbkjt3-d-N8-syUljb45Ggc7USnnFoDWJWoxZ94s4q5C9S3cfbBzj_tuiZ_AQOdRwg</recordid><startdate>199007</startdate><enddate>199007</enddate><creator>Deeb, G M</creator><creator>Bolling, S F</creator><creator>Nicklas, J</creator><creator>Walsh, R S</creator><creator>Steimle, C N</creator><creator>Shea, M J</creator><creator>Meagher, J S</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>199007</creationdate><title>Clinical experience with the Nimbus pump</title><author>Deeb, G M ; Bolling, S F ; Nicklas, J ; Walsh, R S ; Steimle, C N ; Shea, M J ; Meagher, J S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p121t-8ef8601e3dbf8f1123ce5dfe8a4b116642162079683cd06ac14152918466c2803</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Cardiac Output - physiology</topic><topic>Cardiomyopathies - therapy</topic><topic>Equipment Design</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Heart Transplantation - instrumentation</topic><topic>Heart-Assist Devices</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Myocardial Infarction - therapy</topic><topic>Postoperative Complications - therapy</topic><topic>Shock, Cardiogenic - therapy</topic><toplevel>online_resources</toplevel><creatorcontrib>Deeb, G M</creatorcontrib><creatorcontrib>Bolling, S F</creatorcontrib><creatorcontrib>Nicklas, J</creatorcontrib><creatorcontrib>Walsh, R S</creatorcontrib><creatorcontrib>Steimle, C N</creatorcontrib><creatorcontrib>Shea, M J</creatorcontrib><creatorcontrib>Meagher, J S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>ASAIO transactions</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Deeb, G M</au><au>Bolling, S F</au><au>Nicklas, J</au><au>Walsh, R S</au><au>Steimle, C N</au><au>Shea, M J</au><au>Meagher, J S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Clinical experience with the Nimbus pump</atitle><jtitle>ASAIO transactions</jtitle><addtitle>ASAIO Trans</addtitle><date>1990-07</date><risdate>1990</risdate><volume>36</volume><issue>3</issue><spage>M632</spage><epage>M636</epage><pages>M632-M636</pages><issn>0889-7190</issn><abstract>The Nimbus pump is an indwelling, electromagnetic powered left ventricular (LV) assist device inserted transfemorally. The inflow cannula (7 mm) is positioned across the aortic valve and the pump in the descending aorta. Indications for insertion include cardiogenic shock despite maximal medical support and PCWP greater than 18 mmHg, MAP less than 90 mmHg, and Cl less than 2 L/min/m2. Twelve patients underwent the attempt at surgical insertion of the Nimbus pump. Diagnoses included eight acute myocardial infarctions (AMI), two ischemic cardiomyopathy, one postpartum cardiomyopathy, and one transplanted heart rejection. Eight (67%) of twelve patients had successful insertion. One patient had peripheral vascular disease preventing passage, and three had femoral vessels too small for insertion (less than 7.5 Hagar dilator). Five patients with the diagnosis of AMI had successful insertion and three (60%) underwent sufficient LV recovery for removal of the device; the other two patients died of stroke and ventricular arrhythmias, respectively. Three patients with the diagnosis of cardiomyopathy had progression of the disease process, and their needs exceeded the capabilities of the pump and they died of multiorgan failure. The Nimbus pump is an attractive LV assist device because of its pumping capacity (3.5 L/min) and minor surgical procedure for insertion. However, its application is limited because of access route and size. The device appears to work well for patients in cardiogenic shock after AMI (60% recovery) but does not appear indicated for patients with cadiomyopathy.</abstract><cop>United States</cop><pmid>2252770</pmid></addata></record>
fulltext fulltext
identifier ISSN: 0889-7190
ispartof ASAIO transactions, 1990-07, Vol.36 (3), p.M632-M636
issn 0889-7190
language eng
recordid cdi_proquest_miscellaneous_80154172
source MEDLINE; Journals@Ovid Complete
subjects Adult
Aged
Cardiac Output - physiology
Cardiomyopathies - therapy
Equipment Design
Female
Follow-Up Studies
Heart Transplantation - instrumentation
Heart-Assist Devices
Humans
Male
Middle Aged
Myocardial Infarction - therapy
Postoperative Complications - therapy
Shock, Cardiogenic - therapy
title Clinical experience with the Nimbus pump
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T20%3A21%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Clinical%20experience%20with%20the%20Nimbus%20pump&rft.jtitle=ASAIO%20transactions&rft.au=Deeb,%20G%20M&rft.date=1990-07&rft.volume=36&rft.issue=3&rft.spage=M632&rft.epage=M636&rft.pages=M632-M636&rft.issn=0889-7190&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E80154172%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80154172&rft_id=info:pmid/2252770&rfr_iscdi=true