The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats

The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats The objective of this study is to investigate the effect of normovolaemic haemodilution (anaemia), haemoglobin level and replacement fluids on the survival of local flaps in rats. Fifty male...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical otolaryngology and allied sciences 2004-02, Vol.29 (1), p.80-83
Hauptverfasser: Tüz, M., Eroğlu, E., Doğru, H., Deli̇baş, N., Tunç, B., Uygur, K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 83
container_issue 1
container_start_page 80
container_title Clinical otolaryngology and allied sciences
container_volume 29
creator Tüz, M.
Eroğlu, E.
Doğru, H.
Deli̇baş, N.
Tunç, B.
Uygur, K.
description The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats The objective of this study is to investigate the effect of normovolaemic haemodilution (anaemia), haemoglobin level and replacement fluids on the survival of local flaps in rats. Fifty male Wistar rats were divided into four study groups and one control group (10 rats for each). In the study groups, 20% or 30% of blood was withdrawn and replaced by either Gelofusine® or saline (0.9%). Single 1.5 cm × 3 cm cranially based dorsal random skin flaps consisting of skin and panniculus carnosus were elevated in all rats. No difference was determined between the control and 20% exsanguinated groups regarding flap survival area. There was a statistically significant difference between the flap survival areas of 20% exsanguinated groups and 30% exsanguinated groups. If the blood loss exceeds 30% of total volume and/or haemoglobin (Hb) level is lower than 10.72 g/dL, the risk of flap necrosis increases significantly.
doi_str_mv 10.1111/j.1365-2273.2004.00787.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80152840</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80152840</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4707-c318f6f3f542a6f3ed0831bce92039ede430f4f23db472d9604e51c1307a24973</originalsourceid><addsrcrecordid>eNqNkM1u1DAUhS0EotPCKyCv2CX4L3EisakGaKmqVq0KXVoe51r11IkHOxmmb1-HGbVbLEv3SD7n2P4QwpSUNK8v65LyuioYk7xkhIiSENnIcvcGLV4O3qIF4UQWUkp2hI5TWpPspFK-R0dUtDVtKrlA_d0DYLAWzIiDxRE2XhvoYRix9ZPrEtZDh4cQ-7ANXkPvDH7II3TOT6MLA857zB1pilu31X5u6UJMWaVHN-QWvUk4i6jH9AG9s9on-HiYJ-jXj-93y_Pi8vrs5_L0sjBC5icbThtbW24rwXSe0JGG05WBlhHeQgeCEyss491KSNa1NRFQUUPzdzUTreQn6PO-dxPDnwnSqHqXDHivBwhTUg2hFWsEycZmbzQxpBTBqk10vY5PihI1o1ZrNRNVM1E1o1b_UKtdjn463DGteuhegwe22fB1b_jrPDz9d7FaXp9mkePFPu7SCLuXuI6PqpZcVur-6kzd3l98O7_5XakL_gxwDZz4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80152840</pqid></control><display><type>article</type><title>The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Tüz, M. ; Eroğlu, E. ; Doğru, H. ; Deli̇baş, N. ; Tunç, B. ; Uygur, K.</creator><creatorcontrib>Tüz, M. ; Eroğlu, E. ; Doğru, H. ; Deli̇baş, N. ; Tunç, B. ; Uygur, K.</creatorcontrib><description>The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats The objective of this study is to investigate the effect of normovolaemic haemodilution (anaemia), haemoglobin level and replacement fluids on the survival of local flaps in rats. Fifty male Wistar rats were divided into four study groups and one control group (10 rats for each). In the study groups, 20% or 30% of blood was withdrawn and replaced by either Gelofusine® or saline (0.9%). Single 1.5 cm × 3 cm cranially based dorsal random skin flaps consisting of skin and panniculus carnosus were elevated in all rats. No difference was determined between the control and 20% exsanguinated groups regarding flap survival area. There was a statistically significant difference between the flap survival areas of 20% exsanguinated groups and 30% exsanguinated groups. If the blood loss exceeds 30% of total volume and/or haemoglobin (Hb) level is lower than 10.72 g/dL, the risk of flap necrosis increases significantly.</description><identifier>ISSN: 0307-7772</identifier><identifier>EISSN: 1365-2273</identifier><identifier>DOI: 10.1111/j.1365-2273.2004.00787.x</identifier><identifier>PMID: 14961857</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Science Ltd</publisher><subject>Anemia - blood ; Anemia - complications ; Animals ; flap ; Fluid Therapy ; Gelatin - administration &amp; dosage ; Graft Survival - drug effects ; haemoglobin ; Hemodilution - methods ; Hemoglobins - analysis ; Hypovolemia - complications ; Male ; normovolaemic haemodilution ; Plasma Substitutes - administration &amp; dosage ; rat ; Rats ; Rats, Wistar ; Sodium Chloride - administration &amp; dosage ; Succinates - administration &amp; dosage ; Surgical Flaps - blood supply</subject><ispartof>Clinical otolaryngology and allied sciences, 2004-02, Vol.29 (1), p.80-83</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4707-c318f6f3f542a6f3ed0831bce92039ede430f4f23db472d9604e51c1307a24973</citedby><cites>FETCH-LOGICAL-c4707-c318f6f3f542a6f3ed0831bce92039ede430f4f23db472d9604e51c1307a24973</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1365-2273.2004.00787.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1365-2273.2004.00787.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,778,782,1414,27907,27908,45557,45558</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/14961857$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tüz, M.</creatorcontrib><creatorcontrib>Eroğlu, E.</creatorcontrib><creatorcontrib>Doğru, H.</creatorcontrib><creatorcontrib>Deli̇baş, N.</creatorcontrib><creatorcontrib>Tunç, B.</creatorcontrib><creatorcontrib>Uygur, K.</creatorcontrib><title>The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats</title><title>Clinical otolaryngology and allied sciences</title><addtitle>Clin Otolaryngol Allied Sci</addtitle><description>The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats The objective of this study is to investigate the effect of normovolaemic haemodilution (anaemia), haemoglobin level and replacement fluids on the survival of local flaps in rats. Fifty male Wistar rats were divided into four study groups and one control group (10 rats for each). In the study groups, 20% or 30% of blood was withdrawn and replaced by either Gelofusine® or saline (0.9%). Single 1.5 cm × 3 cm cranially based dorsal random skin flaps consisting of skin and panniculus carnosus were elevated in all rats. No difference was determined between the control and 20% exsanguinated groups regarding flap survival area. There was a statistically significant difference between the flap survival areas of 20% exsanguinated groups and 30% exsanguinated groups. If the blood loss exceeds 30% of total volume and/or haemoglobin (Hb) level is lower than 10.72 g/dL, the risk of flap necrosis increases significantly.</description><subject>Anemia - blood</subject><subject>Anemia - complications</subject><subject>Animals</subject><subject>flap</subject><subject>Fluid Therapy</subject><subject>Gelatin - administration &amp; dosage</subject><subject>Graft Survival - drug effects</subject><subject>haemoglobin</subject><subject>Hemodilution - methods</subject><subject>Hemoglobins - analysis</subject><subject>Hypovolemia - complications</subject><subject>Male</subject><subject>normovolaemic haemodilution</subject><subject>Plasma Substitutes - administration &amp; dosage</subject><subject>rat</subject><subject>Rats</subject><subject>Rats, Wistar</subject><subject>Sodium Chloride - administration &amp; dosage</subject><subject>Succinates - administration &amp; dosage</subject><subject>Surgical Flaps - blood supply</subject><issn>0307-7772</issn><issn>1365-2273</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkM1u1DAUhS0EotPCKyCv2CX4L3EisakGaKmqVq0KXVoe51r11IkHOxmmb1-HGbVbLEv3SD7n2P4QwpSUNK8v65LyuioYk7xkhIiSENnIcvcGLV4O3qIF4UQWUkp2hI5TWpPspFK-R0dUtDVtKrlA_d0DYLAWzIiDxRE2XhvoYRix9ZPrEtZDh4cQ-7ANXkPvDH7II3TOT6MLA857zB1pilu31X5u6UJMWaVHN-QWvUk4i6jH9AG9s9on-HiYJ-jXj-93y_Pi8vrs5_L0sjBC5icbThtbW24rwXSe0JGG05WBlhHeQgeCEyss491KSNa1NRFQUUPzdzUTreQn6PO-dxPDnwnSqHqXDHivBwhTUg2hFWsEycZmbzQxpBTBqk10vY5PihI1o1ZrNRNVM1E1o1b_UKtdjn463DGteuhegwe22fB1b_jrPDz9d7FaXp9mkePFPu7SCLuXuI6PqpZcVur-6kzd3l98O7_5XakL_gxwDZz4</recordid><startdate>200402</startdate><enddate>200402</enddate><creator>Tüz, M.</creator><creator>Eroğlu, E.</creator><creator>Doğru, H.</creator><creator>Deli̇baş, N.</creator><creator>Tunç, B.</creator><creator>Uygur, K.</creator><general>Blackwell Science Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200402</creationdate><title>The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats</title><author>Tüz, M. ; Eroğlu, E. ; Doğru, H. ; Deli̇baş, N. ; Tunç, B. ; Uygur, K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4707-c318f6f3f542a6f3ed0831bce92039ede430f4f23db472d9604e51c1307a24973</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Anemia - blood</topic><topic>Anemia - complications</topic><topic>Animals</topic><topic>flap</topic><topic>Fluid Therapy</topic><topic>Gelatin - administration &amp; dosage</topic><topic>Graft Survival - drug effects</topic><topic>haemoglobin</topic><topic>Hemodilution - methods</topic><topic>Hemoglobins - analysis</topic><topic>Hypovolemia - complications</topic><topic>Male</topic><topic>normovolaemic haemodilution</topic><topic>Plasma Substitutes - administration &amp; dosage</topic><topic>rat</topic><topic>Rats</topic><topic>Rats, Wistar</topic><topic>Sodium Chloride - administration &amp; dosage</topic><topic>Succinates - administration &amp; dosage</topic><topic>Surgical Flaps - blood supply</topic><toplevel>online_resources</toplevel><creatorcontrib>Tüz, M.</creatorcontrib><creatorcontrib>Eroğlu, E.</creatorcontrib><creatorcontrib>Doğru, H.</creatorcontrib><creatorcontrib>Deli̇baş, N.</creatorcontrib><creatorcontrib>Tunç, B.</creatorcontrib><creatorcontrib>Uygur, K.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical otolaryngology and allied sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tüz, M.</au><au>Eroğlu, E.</au><au>Doğru, H.</au><au>Deli̇baş, N.</au><au>Tunç, B.</au><au>Uygur, K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats</atitle><jtitle>Clinical otolaryngology and allied sciences</jtitle><addtitle>Clin Otolaryngol Allied Sci</addtitle><date>2004-02</date><risdate>2004</risdate><volume>29</volume><issue>1</issue><spage>80</spage><epage>83</epage><pages>80-83</pages><issn>0307-7772</issn><eissn>1365-2273</eissn><abstract>The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats The objective of this study is to investigate the effect of normovolaemic haemodilution (anaemia), haemoglobin level and replacement fluids on the survival of local flaps in rats. Fifty male Wistar rats were divided into four study groups and one control group (10 rats for each). In the study groups, 20% or 30% of blood was withdrawn and replaced by either Gelofusine® or saline (0.9%). Single 1.5 cm × 3 cm cranially based dorsal random skin flaps consisting of skin and panniculus carnosus were elevated in all rats. No difference was determined between the control and 20% exsanguinated groups regarding flap survival area. There was a statistically significant difference between the flap survival areas of 20% exsanguinated groups and 30% exsanguinated groups. If the blood loss exceeds 30% of total volume and/or haemoglobin (Hb) level is lower than 10.72 g/dL, the risk of flap necrosis increases significantly.</abstract><cop>Oxford, UK</cop><pub>Blackwell Science Ltd</pub><pmid>14961857</pmid><doi>10.1111/j.1365-2273.2004.00787.x</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0307-7772
ispartof Clinical otolaryngology and allied sciences, 2004-02, Vol.29 (1), p.80-83
issn 0307-7772
1365-2273
language eng
recordid cdi_proquest_miscellaneous_80152840
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects Anemia - blood
Anemia - complications
Animals
flap
Fluid Therapy
Gelatin - administration & dosage
Graft Survival - drug effects
haemoglobin
Hemodilution - methods
Hemoglobins - analysis
Hypovolemia - complications
Male
normovolaemic haemodilution
Plasma Substitutes - administration & dosage
rat
Rats
Rats, Wistar
Sodium Chloride - administration & dosage
Succinates - administration & dosage
Surgical Flaps - blood supply
title The effect of replacement fluids and normovolaemic haemodilution on the survival of dorsal skin flaps in rats
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T18%3A30%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20effect%20of%20replacement%20fluids%20and%20normovolaemic%20haemodilution%20on%20the%20survival%20of%20dorsal%20skin%20flaps%20in%20rats&rft.jtitle=Clinical%20otolaryngology%20and%20allied%20sciences&rft.au=T%C3%BCz,%20M.&rft.date=2004-02&rft.volume=29&rft.issue=1&rft.spage=80&rft.epage=83&rft.pages=80-83&rft.issn=0307-7772&rft.eissn=1365-2273&rft_id=info:doi/10.1111/j.1365-2273.2004.00787.x&rft_dat=%3Cproquest_cross%3E80152840%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80152840&rft_id=info:pmid/14961857&rfr_iscdi=true