Direct resistively heated column gas chromatography (Ultrafast module-GC) for high-speed analysis of essential oils of differing complexities
This study applies Ultrafast module-GC (UFM-GC) with direct resistively heated columns to routine analysis of a group of essential oils of differing complexities (chamomile, peppermint, rosemary and sage). Essential oils were analysed by conventional GC with conventional inner diameter (i.d.) column...
Gespeichert in:
Veröffentlicht in: | Journal of Chromatography A 2004-01, Vol.1024 (1), p.195-207 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 207 |
---|---|
container_issue | 1 |
container_start_page | 195 |
container_title | Journal of Chromatography A |
container_volume | 1024 |
creator | Bicchi, Carlo Brunelli, Claudio Cordero, Chiara Rubiolo, Patrizia Galli, Mario Sironi, Albino |
description | This study applies Ultrafast module-GC (UFM-GC) with direct resistively heated columns to routine analysis of a group of essential oils of differing complexities (chamomile, peppermint, rosemary and sage). Essential oils were analysed by conventional GC with conventional inner diameter (i.d.) columns (0.25
mm) of different lengths (5 and 25
m long) and by Fast GC and Ultrafast module-GC with narrow bore columns (0.1
mm i.d., 5
m long). Column performance were evaluated and compared through their Grob test, separation number and peak capacity. Ultrafast module-GC was successful in the qualitative and quantitative analysis of essential oils of different compositions with analysis times between 40
s and 2
min versus 20–60
min required by conventional GC. Critical pairs or groups of components were separated by carefully tuning selectivity of the stationary phase to compensate for loss of efficiency due to the use of short columns and high temperature rates. The Ultrafast module-GC results of peppermint e.o. analyses were also validated and compared to those obtained by conventional GC; by measuring precision over time (i.e. repeatability and intermediate precision) and accuracy. Ultrafast module-GC showed a good separation reproducibility affording reliable component identification through the relative retention times and quantitative determination through normalised peak areas. Accuracy data also showed that Ultrafast module-GC and conventional GC normalised areas and areas percentage were perfectly comparable. |
doi_str_mv | 10.1016/j.chroma.2003.10.018 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80136093</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021967303018673</els_id><sourcerecordid>80136093</sourcerecordid><originalsourceid>FETCH-LOGICAL-c500t-20baf24d8b551e53906373b1aefa3695cb32a4187926016fcc957baadbf332283</originalsourceid><addsrcrecordid>eNp9kc1q3DAUhb1oSdKkb1CKNi3NwlP9-HdTCNMmLQS6adbiWr4aa5AtV5JD5yHyztHEA9l1JTh850h8yrIPjG4YZdXX_UYN3o2w4ZSKFG0oa95kF5RylrdVLc6zdyHsKWU1rflZds6KuhQ15xfZ03fjUUXiMZgQzSPaAxkQIvZEObuME9lBIOt6dDsP83AgXx5s9KAhRDK6frGY322viXaeDGY35GHGVIcJ7CGNEqcJhoBTNGCJM_Yl6Y3W6M20S9eMs8V_JhoMV9lbDTbg-9N5mT3c_viz_Znf_777tb25z1VJacw57UDzom-6smRYipZWohYdA9QgqrZUneBQsKZueZX0aKXasu4A-k4LwXkjLrPP6-7s3d8FQ5SjCQqthQndEmRDmahoKxJYrKDyLgSPWs7ejOAPklF5VC_3cpUjj-qPaVKfah9P-0s3Yv9aOnlPwKcTAEGB1R4mZcIrVxYNTVjivq0cJhuPBr0MyuCksH_5Ntk78_-XPAMdm6hj</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80136093</pqid></control><display><type>article</type><title>Direct resistively heated column gas chromatography (Ultrafast module-GC) for high-speed analysis of essential oils of differing complexities</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Bicchi, Carlo ; Brunelli, Claudio ; Cordero, Chiara ; Rubiolo, Patrizia ; Galli, Mario ; Sironi, Albino</creator><creatorcontrib>Bicchi, Carlo ; Brunelli, Claudio ; Cordero, Chiara ; Rubiolo, Patrizia ; Galli, Mario ; Sironi, Albino</creatorcontrib><description>This study applies Ultrafast module-GC (UFM-GC) with direct resistively heated columns to routine analysis of a group of essential oils of differing complexities (chamomile, peppermint, rosemary and sage). Essential oils were analysed by conventional GC with conventional inner diameter (i.d.) columns (0.25
mm) of different lengths (5 and 25
m long) and by Fast GC and Ultrafast module-GC with narrow bore columns (0.1
mm i.d., 5
m long). Column performance were evaluated and compared through their Grob test, separation number and peak capacity. Ultrafast module-GC was successful in the qualitative and quantitative analysis of essential oils of different compositions with analysis times between 40
s and 2
min versus 20–60
min required by conventional GC. Critical pairs or groups of components were separated by carefully tuning selectivity of the stationary phase to compensate for loss of efficiency due to the use of short columns and high temperature rates. The Ultrafast module-GC results of peppermint e.o. analyses were also validated and compared to those obtained by conventional GC; by measuring precision over time (i.e. repeatability and intermediate precision) and accuracy. Ultrafast module-GC showed a good separation reproducibility affording reliable component identification through the relative retention times and quantitative determination through normalised peak areas. Accuracy data also showed that Ultrafast module-GC and conventional GC normalised areas and areas percentage were perfectly comparable.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/j.chroma.2003.10.018</identifier><identifier>PMID: 14753722</identifier><identifier>CODEN: JOCRAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Applied sciences ; Chemical industry and chemicals ; Chromatography, Gas - methods ; Direct resistively heated columns ; Essential oils ; Essential oils, perfumes ; Exact sciences and technology ; Oils, Volatile - analysis ; Reproducibility of Results ; Ultrafast module gas chromatography ; Washing products. Cosmetics and toiletries. Perfumes</subject><ispartof>Journal of Chromatography A, 2004-01, Vol.1024 (1), p.195-207</ispartof><rights>2003 Elsevier B.V.</rights><rights>2004 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c500t-20baf24d8b551e53906373b1aefa3695cb32a4187926016fcc957baadbf332283</citedby><cites>FETCH-LOGICAL-c500t-20baf24d8b551e53906373b1aefa3695cb32a4187926016fcc957baadbf332283</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0021967303018673$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27903,27904,65309</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=15480223$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/14753722$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bicchi, Carlo</creatorcontrib><creatorcontrib>Brunelli, Claudio</creatorcontrib><creatorcontrib>Cordero, Chiara</creatorcontrib><creatorcontrib>Rubiolo, Patrizia</creatorcontrib><creatorcontrib>Galli, Mario</creatorcontrib><creatorcontrib>Sironi, Albino</creatorcontrib><title>Direct resistively heated column gas chromatography (Ultrafast module-GC) for high-speed analysis of essential oils of differing complexities</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>This study applies Ultrafast module-GC (UFM-GC) with direct resistively heated columns to routine analysis of a group of essential oils of differing complexities (chamomile, peppermint, rosemary and sage). Essential oils were analysed by conventional GC with conventional inner diameter (i.d.) columns (0.25
mm) of different lengths (5 and 25
m long) and by Fast GC and Ultrafast module-GC with narrow bore columns (0.1
mm i.d., 5
m long). Column performance were evaluated and compared through their Grob test, separation number and peak capacity. Ultrafast module-GC was successful in the qualitative and quantitative analysis of essential oils of different compositions with analysis times between 40
s and 2
min versus 20–60
min required by conventional GC. Critical pairs or groups of components were separated by carefully tuning selectivity of the stationary phase to compensate for loss of efficiency due to the use of short columns and high temperature rates. The Ultrafast module-GC results of peppermint e.o. analyses were also validated and compared to those obtained by conventional GC; by measuring precision over time (i.e. repeatability and intermediate precision) and accuracy. Ultrafast module-GC showed a good separation reproducibility affording reliable component identification through the relative retention times and quantitative determination through normalised peak areas. Accuracy data also showed that Ultrafast module-GC and conventional GC normalised areas and areas percentage were perfectly comparable.</description><subject>Applied sciences</subject><subject>Chemical industry and chemicals</subject><subject>Chromatography, Gas - methods</subject><subject>Direct resistively heated columns</subject><subject>Essential oils</subject><subject>Essential oils, perfumes</subject><subject>Exact sciences and technology</subject><subject>Oils, Volatile - analysis</subject><subject>Reproducibility of Results</subject><subject>Ultrafast module gas chromatography</subject><subject>Washing products. Cosmetics and toiletries. Perfumes</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kc1q3DAUhb1oSdKkb1CKNi3NwlP9-HdTCNMmLQS6adbiWr4aa5AtV5JD5yHyztHEA9l1JTh850h8yrIPjG4YZdXX_UYN3o2w4ZSKFG0oa95kF5RylrdVLc6zdyHsKWU1rflZds6KuhQ15xfZ03fjUUXiMZgQzSPaAxkQIvZEObuME9lBIOt6dDsP83AgXx5s9KAhRDK6frGY322viXaeDGY35GHGVIcJ7CGNEqcJhoBTNGCJM_Yl6Y3W6M20S9eMs8V_JhoMV9lbDTbg-9N5mT3c_viz_Znf_777tb25z1VJacw57UDzom-6smRYipZWohYdA9QgqrZUneBQsKZueZX0aKXasu4A-k4LwXkjLrPP6-7s3d8FQ5SjCQqthQndEmRDmahoKxJYrKDyLgSPWs7ejOAPklF5VC_3cpUjj-qPaVKfah9P-0s3Yv9aOnlPwKcTAEGB1R4mZcIrVxYNTVjivq0cJhuPBr0MyuCksH_5Ntk78_-XPAMdm6hj</recordid><startdate>20040123</startdate><enddate>20040123</enddate><creator>Bicchi, Carlo</creator><creator>Brunelli, Claudio</creator><creator>Cordero, Chiara</creator><creator>Rubiolo, Patrizia</creator><creator>Galli, Mario</creator><creator>Sironi, Albino</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20040123</creationdate><title>Direct resistively heated column gas chromatography (Ultrafast module-GC) for high-speed analysis of essential oils of differing complexities</title><author>Bicchi, Carlo ; Brunelli, Claudio ; Cordero, Chiara ; Rubiolo, Patrizia ; Galli, Mario ; Sironi, Albino</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c500t-20baf24d8b551e53906373b1aefa3695cb32a4187926016fcc957baadbf332283</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Applied sciences</topic><topic>Chemical industry and chemicals</topic><topic>Chromatography, Gas - methods</topic><topic>Direct resistively heated columns</topic><topic>Essential oils</topic><topic>Essential oils, perfumes</topic><topic>Exact sciences and technology</topic><topic>Oils, Volatile - analysis</topic><topic>Reproducibility of Results</topic><topic>Ultrafast module gas chromatography</topic><topic>Washing products. Cosmetics and toiletries. Perfumes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bicchi, Carlo</creatorcontrib><creatorcontrib>Brunelli, Claudio</creatorcontrib><creatorcontrib>Cordero, Chiara</creatorcontrib><creatorcontrib>Rubiolo, Patrizia</creatorcontrib><creatorcontrib>Galli, Mario</creatorcontrib><creatorcontrib>Sironi, Albino</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bicchi, Carlo</au><au>Brunelli, Claudio</au><au>Cordero, Chiara</au><au>Rubiolo, Patrizia</au><au>Galli, Mario</au><au>Sironi, Albino</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Direct resistively heated column gas chromatography (Ultrafast module-GC) for high-speed analysis of essential oils of differing complexities</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2004-01-23</date><risdate>2004</risdate><volume>1024</volume><issue>1</issue><spage>195</spage><epage>207</epage><pages>195-207</pages><issn>0021-9673</issn><coden>JOCRAM</coden><abstract>This study applies Ultrafast module-GC (UFM-GC) with direct resistively heated columns to routine analysis of a group of essential oils of differing complexities (chamomile, peppermint, rosemary and sage). Essential oils were analysed by conventional GC with conventional inner diameter (i.d.) columns (0.25
mm) of different lengths (5 and 25
m long) and by Fast GC and Ultrafast module-GC with narrow bore columns (0.1
mm i.d., 5
m long). Column performance were evaluated and compared through their Grob test, separation number and peak capacity. Ultrafast module-GC was successful in the qualitative and quantitative analysis of essential oils of different compositions with analysis times between 40
s and 2
min versus 20–60
min required by conventional GC. Critical pairs or groups of components were separated by carefully tuning selectivity of the stationary phase to compensate for loss of efficiency due to the use of short columns and high temperature rates. The Ultrafast module-GC results of peppermint e.o. analyses were also validated and compared to those obtained by conventional GC; by measuring precision over time (i.e. repeatability and intermediate precision) and accuracy. Ultrafast module-GC showed a good separation reproducibility affording reliable component identification through the relative retention times and quantitative determination through normalised peak areas. Accuracy data also showed that Ultrafast module-GC and conventional GC normalised areas and areas percentage were perfectly comparable.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>14753722</pmid><doi>10.1016/j.chroma.2003.10.018</doi><tpages>13</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-9673 |
ispartof | Journal of Chromatography A, 2004-01, Vol.1024 (1), p.195-207 |
issn | 0021-9673 |
language | eng |
recordid | cdi_proquest_miscellaneous_80136093 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Applied sciences Chemical industry and chemicals Chromatography, Gas - methods Direct resistively heated columns Essential oils Essential oils, perfumes Exact sciences and technology Oils, Volatile - analysis Reproducibility of Results Ultrafast module gas chromatography Washing products. Cosmetics and toiletries. Perfumes |
title | Direct resistively heated column gas chromatography (Ultrafast module-GC) for high-speed analysis of essential oils of differing complexities |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T05%3A05%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Direct%20resistively%20heated%20column%20gas%20chromatography%20(Ultrafast%20module-GC)%20for%20high-speed%20analysis%20of%20essential%20oils%20of%20differing%20complexities&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Bicchi,%20Carlo&rft.date=2004-01-23&rft.volume=1024&rft.issue=1&rft.spage=195&rft.epage=207&rft.pages=195-207&rft.issn=0021-9673&rft.coden=JOCRAM&rft_id=info:doi/10.1016/j.chroma.2003.10.018&rft_dat=%3Cproquest_cross%3E80136093%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80136093&rft_id=info:pmid/14753722&rft_els_id=S0021967303018673&rfr_iscdi=true |