Noquist: Reduced field-of-view imaging by direct Fourier inversion
A novel technique called “Noquist” is introduced for the acceleration of dynamic cardiac magnetic resonance imaging (CMRI). With the use of this technique, a more sparsely sampled dynamic image sequence is reconstructed correctly, without Nyquist foldover artifact. Unlike most other reduced field‐of...
Gespeichert in:
Veröffentlicht in: | Magnetic resonance in medicine 2004-02, Vol.51 (2), p.331-342 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 342 |
---|---|
container_issue | 2 |
container_start_page | 331 |
container_title | Magnetic resonance in medicine |
container_volume | 51 |
creator | Brummer, Marijn E. Moratal-Pérez, David Hong, Chung-Yi Pettigrew, Roderic I. Millet-Roig, José Dixon, W. Thomas |
description | A novel technique called “Noquist” is introduced for the acceleration of dynamic cardiac magnetic resonance imaging (CMRI). With the use of this technique, a more sparsely sampled dynamic image sequence is reconstructed correctly, without Nyquist foldover artifact. Unlike most other reduced field‐of‐view (rFOV) methods, Noquist does not rely on data substitution or temporal interpolation to reconstruct the dynamic image sequence. The proposed method reduces acquisition time in dynamic MRI scans by eliminating the data redundancy associated with static regions in the dynamic scene. A reduction of imaging time is achieved by a fraction asymptotically equal to the static fraction of the FOV, by omitting acquisition of an appropriate subset of phase‐encoding views from a conventional equidistant Cartesian acquisition grid. The theory behind this method is presented along with sample reconstructions from real and simulated data. Noquist is compared with conventional cine imaging by retrospective selection of a reduced data set from a full‐grid conventional image sequence. In addition, a comparison is presented, using real and simulated data, of our technique with an existing rFOV technique that uses temporal interpolation. The experimental results confirm the theory, and demonstrate that Noquist reduces scan time for cine MRI while fully preserving both spatial and temporal resolution, but at the cost of a reduced signal‐to‐noise ratio (SNR). Magn Reson Med 51:331–342, 2004. © 2004 Wiley‐Liss, Inc. |
doi_str_mv | 10.1002/mrm.10694 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80130818</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>19239926</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3904-8d429cf1fa960230e5c712419cfa9819783bc91aa6e3aa0758e15eb1b8171f893</originalsourceid><addsrcrecordid>eNqFkE1LJDEQhoMoOroe_APSJ8FDayofncSbio7iFwy7CF5Curtaot3Tmkzrzr_frDO6p8VTFcVTL1UPITtAD4BSdtiFLjWFEStkBJKxnEkjVsmIKkFzDkZskM0YnyilxiixTjZAKCkLaUbk5LZ_HXycHWUTrIcK66zx2NZ53-RvHt8z37lHP33MynlW-4DVLDvvh-AxZH76hiH6fvqDrDWujbi9rFvk1_nZz9OL_PpufHl6fJ1X3FCR61owUzXQOFNQxinKSgETkGbOaDBK87Iy4FyB3DmqpEaQWEKpQUGjDd8ie4vcl5BuxjiznY8Vtq2bYj9EqylwqkF_C4Jh3BhWJHB_AVahjzFgY19CejjMLVD716xNZu2H2cTuLkOHssP6H7lUmYDDBfDuW5z_P8neTG4-I_PFRvKPv782XHi2heJK2vvbsb24EpPiYSyt5H8APXeQUg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>19239926</pqid></control><display><type>article</type><title>Noquist: Reduced field-of-view imaging by direct Fourier inversion</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><source>Wiley Free Content</source><creator>Brummer, Marijn E. ; Moratal-Pérez, David ; Hong, Chung-Yi ; Pettigrew, Roderic I. ; Millet-Roig, José ; Dixon, W. Thomas</creator><creatorcontrib>Brummer, Marijn E. ; Moratal-Pérez, David ; Hong, Chung-Yi ; Pettigrew, Roderic I. ; Millet-Roig, José ; Dixon, W. Thomas</creatorcontrib><description>A novel technique called “Noquist” is introduced for the acceleration of dynamic cardiac magnetic resonance imaging (CMRI). With the use of this technique, a more sparsely sampled dynamic image sequence is reconstructed correctly, without Nyquist foldover artifact. Unlike most other reduced field‐of‐view (rFOV) methods, Noquist does not rely on data substitution or temporal interpolation to reconstruct the dynamic image sequence. The proposed method reduces acquisition time in dynamic MRI scans by eliminating the data redundancy associated with static regions in the dynamic scene. A reduction of imaging time is achieved by a fraction asymptotically equal to the static fraction of the FOV, by omitting acquisition of an appropriate subset of phase‐encoding views from a conventional equidistant Cartesian acquisition grid. The theory behind this method is presented along with sample reconstructions from real and simulated data. Noquist is compared with conventional cine imaging by retrospective selection of a reduced data set from a full‐grid conventional image sequence. In addition, a comparison is presented, using real and simulated data, of our technique with an existing rFOV technique that uses temporal interpolation. The experimental results confirm the theory, and demonstrate that Noquist reduces scan time for cine MRI while fully preserving both spatial and temporal resolution, but at the cost of a reduced signal‐to‐noise ratio (SNR). Magn Reson Med 51:331–342, 2004. © 2004 Wiley‐Liss, Inc.</description><identifier>ISSN: 0740-3194</identifier><identifier>EISSN: 1522-2594</identifier><identifier>DOI: 10.1002/mrm.10694</identifier><identifier>PMID: 14755659</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Algorithms ; cardiac imaging ; Fast cine imaging ; Fourier Analysis ; Heart - anatomy & histology ; Humans ; Image Processing, Computer-Assisted ; image reconstruction ; Magnetic Resonance Imaging - methods ; Magnetic Resonance Imaging, Cine ; Models, Theoretical ; MRI ; Phantoms, Imaging ; reduced field of view</subject><ispartof>Magnetic resonance in medicine, 2004-02, Vol.51 (2), p.331-342</ispartof><rights>Copyright © 2004 Wiley‐Liss, Inc.</rights><rights>Copyright 2004 Wiley-Liss, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3904-8d429cf1fa960230e5c712419cfa9819783bc91aa6e3aa0758e15eb1b8171f893</citedby><cites>FETCH-LOGICAL-c3904-8d429cf1fa960230e5c712419cfa9819783bc91aa6e3aa0758e15eb1b8171f893</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmrm.10694$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmrm.10694$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,777,781,1412,1428,27905,27906,45555,45556,46390,46814</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/14755659$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Brummer, Marijn E.</creatorcontrib><creatorcontrib>Moratal-Pérez, David</creatorcontrib><creatorcontrib>Hong, Chung-Yi</creatorcontrib><creatorcontrib>Pettigrew, Roderic I.</creatorcontrib><creatorcontrib>Millet-Roig, José</creatorcontrib><creatorcontrib>Dixon, W. Thomas</creatorcontrib><title>Noquist: Reduced field-of-view imaging by direct Fourier inversion</title><title>Magnetic resonance in medicine</title><addtitle>Magn. Reson. Med</addtitle><description>A novel technique called “Noquist” is introduced for the acceleration of dynamic cardiac magnetic resonance imaging (CMRI). With the use of this technique, a more sparsely sampled dynamic image sequence is reconstructed correctly, without Nyquist foldover artifact. Unlike most other reduced field‐of‐view (rFOV) methods, Noquist does not rely on data substitution or temporal interpolation to reconstruct the dynamic image sequence. The proposed method reduces acquisition time in dynamic MRI scans by eliminating the data redundancy associated with static regions in the dynamic scene. A reduction of imaging time is achieved by a fraction asymptotically equal to the static fraction of the FOV, by omitting acquisition of an appropriate subset of phase‐encoding views from a conventional equidistant Cartesian acquisition grid. The theory behind this method is presented along with sample reconstructions from real and simulated data. Noquist is compared with conventional cine imaging by retrospective selection of a reduced data set from a full‐grid conventional image sequence. In addition, a comparison is presented, using real and simulated data, of our technique with an existing rFOV technique that uses temporal interpolation. The experimental results confirm the theory, and demonstrate that Noquist reduces scan time for cine MRI while fully preserving both spatial and temporal resolution, but at the cost of a reduced signal‐to‐noise ratio (SNR). Magn Reson Med 51:331–342, 2004. © 2004 Wiley‐Liss, Inc.</description><subject>Algorithms</subject><subject>cardiac imaging</subject><subject>Fast cine imaging</subject><subject>Fourier Analysis</subject><subject>Heart - anatomy & histology</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted</subject><subject>image reconstruction</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Magnetic Resonance Imaging, Cine</subject><subject>Models, Theoretical</subject><subject>MRI</subject><subject>Phantoms, Imaging</subject><subject>reduced field of view</subject><issn>0740-3194</issn><issn>1522-2594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1LJDEQhoMoOroe_APSJ8FDayofncSbio7iFwy7CF5Curtaot3Tmkzrzr_frDO6p8VTFcVTL1UPITtAD4BSdtiFLjWFEStkBJKxnEkjVsmIKkFzDkZskM0YnyilxiixTjZAKCkLaUbk5LZ_HXycHWUTrIcK66zx2NZ53-RvHt8z37lHP33MynlW-4DVLDvvh-AxZH76hiH6fvqDrDWujbi9rFvk1_nZz9OL_PpufHl6fJ1X3FCR61owUzXQOFNQxinKSgETkGbOaDBK87Iy4FyB3DmqpEaQWEKpQUGjDd8ie4vcl5BuxjiznY8Vtq2bYj9EqylwqkF_C4Jh3BhWJHB_AVahjzFgY19CejjMLVD716xNZu2H2cTuLkOHssP6H7lUmYDDBfDuW5z_P8neTG4-I_PFRvKPv782XHi2heJK2vvbsb24EpPiYSyt5H8APXeQUg</recordid><startdate>200402</startdate><enddate>200402</enddate><creator>Brummer, Marijn E.</creator><creator>Moratal-Pérez, David</creator><creator>Hong, Chung-Yi</creator><creator>Pettigrew, Roderic I.</creator><creator>Millet-Roig, José</creator><creator>Dixon, W. Thomas</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>200402</creationdate><title>Noquist: Reduced field-of-view imaging by direct Fourier inversion</title><author>Brummer, Marijn E. ; Moratal-Pérez, David ; Hong, Chung-Yi ; Pettigrew, Roderic I. ; Millet-Roig, José ; Dixon, W. Thomas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3904-8d429cf1fa960230e5c712419cfa9819783bc91aa6e3aa0758e15eb1b8171f893</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Algorithms</topic><topic>cardiac imaging</topic><topic>Fast cine imaging</topic><topic>Fourier Analysis</topic><topic>Heart - anatomy & histology</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted</topic><topic>image reconstruction</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Magnetic Resonance Imaging, Cine</topic><topic>Models, Theoretical</topic><topic>MRI</topic><topic>Phantoms, Imaging</topic><topic>reduced field of view</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Brummer, Marijn E.</creatorcontrib><creatorcontrib>Moratal-Pérez, David</creatorcontrib><creatorcontrib>Hong, Chung-Yi</creatorcontrib><creatorcontrib>Pettigrew, Roderic I.</creatorcontrib><creatorcontrib>Millet-Roig, José</creatorcontrib><creatorcontrib>Dixon, W. Thomas</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Brummer, Marijn E.</au><au>Moratal-Pérez, David</au><au>Hong, Chung-Yi</au><au>Pettigrew, Roderic I.</au><au>Millet-Roig, José</au><au>Dixon, W. Thomas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Noquist: Reduced field-of-view imaging by direct Fourier inversion</atitle><jtitle>Magnetic resonance in medicine</jtitle><addtitle>Magn. Reson. Med</addtitle><date>2004-02</date><risdate>2004</risdate><volume>51</volume><issue>2</issue><spage>331</spage><epage>342</epage><pages>331-342</pages><issn>0740-3194</issn><eissn>1522-2594</eissn><abstract>A novel technique called “Noquist” is introduced for the acceleration of dynamic cardiac magnetic resonance imaging (CMRI). With the use of this technique, a more sparsely sampled dynamic image sequence is reconstructed correctly, without Nyquist foldover artifact. Unlike most other reduced field‐of‐view (rFOV) methods, Noquist does not rely on data substitution or temporal interpolation to reconstruct the dynamic image sequence. The proposed method reduces acquisition time in dynamic MRI scans by eliminating the data redundancy associated with static regions in the dynamic scene. A reduction of imaging time is achieved by a fraction asymptotically equal to the static fraction of the FOV, by omitting acquisition of an appropriate subset of phase‐encoding views from a conventional equidistant Cartesian acquisition grid. The theory behind this method is presented along with sample reconstructions from real and simulated data. Noquist is compared with conventional cine imaging by retrospective selection of a reduced data set from a full‐grid conventional image sequence. In addition, a comparison is presented, using real and simulated data, of our technique with an existing rFOV technique that uses temporal interpolation. The experimental results confirm the theory, and demonstrate that Noquist reduces scan time for cine MRI while fully preserving both spatial and temporal resolution, but at the cost of a reduced signal‐to‐noise ratio (SNR). Magn Reson Med 51:331–342, 2004. © 2004 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>14755659</pmid><doi>10.1002/mrm.10694</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0740-3194 |
ispartof | Magnetic resonance in medicine, 2004-02, Vol.51 (2), p.331-342 |
issn | 0740-3194 1522-2594 |
language | eng |
recordid | cdi_proquest_miscellaneous_80130818 |
source | MEDLINE; Wiley Online Library Journals Frontfile Complete; Wiley Free Content |
subjects | Algorithms cardiac imaging Fast cine imaging Fourier Analysis Heart - anatomy & histology Humans Image Processing, Computer-Assisted image reconstruction Magnetic Resonance Imaging - methods Magnetic Resonance Imaging, Cine Models, Theoretical MRI Phantoms, Imaging reduced field of view |
title | Noquist: Reduced field-of-view imaging by direct Fourier inversion |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T20%3A01%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Noquist:%20Reduced%20field-of-view%20imaging%20by%20direct%20Fourier%20inversion&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=Brummer,%20Marijn%20E.&rft.date=2004-02&rft.volume=51&rft.issue=2&rft.spage=331&rft.epage=342&rft.pages=331-342&rft.issn=0740-3194&rft.eissn=1522-2594&rft_id=info:doi/10.1002/mrm.10694&rft_dat=%3Cproquest_cross%3E19239926%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=19239926&rft_id=info:pmid/14755659&rfr_iscdi=true |