Miniature endoscope for simultaneous optical coherence tomography and laser-induced fluorescence measurement
We have designed a multimodality system that combines optical coherence tomography (OCT) and laser-induced fluorescence (LIF) in a 2.0-mm-diameter endoscopic package. OCT provides approximately 18-microm resolution cross-sectional structural information over a 6-mm field. LIF spectra are collected s...
Gespeichert in:
Veröffentlicht in: | Applied Optics 2004-01, Vol.43 (1), p.113-121 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 121 |
---|---|
container_issue | 1 |
container_start_page | 113 |
container_title | Applied Optics |
container_volume | 43 |
creator | Tumlinson, Alexandre R Hariri, Lida P Utzinger, Urs Barton, Jennifer K |
description | We have designed a multimodality system that combines optical coherence tomography (OCT) and laser-induced fluorescence (LIF) in a 2.0-mm-diameter endoscopic package. OCT provides approximately 18-microm resolution cross-sectional structural information over a 6-mm field. LIF spectra are collected sequentially at submillimeter resolution across the same field and provide histochemical information about the tissue. We present the use of a rod prism to reduce the asymmetry in the OCT beam caused by a cylindrical window. The endoscope has been applied to investigate mouse colon cancer in vivo. |
doi_str_mv | 10.1364/AO.43.000113 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80096376</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80096376</sourcerecordid><originalsourceid>FETCH-LOGICAL-c287t-b1aa804dce51104ee59e1e1f461366afdec979868c439ddd7f01ea7b620c6bfb3</originalsourceid><addsrcrecordid>eNpFkD1PwzAURS0EolDYmJEnJlLs2HHisar4koq6gMRmOfYzDXLiYCdD_z0prcT03nB0dO9F6IaSBWWCPyw3C84WhBBK2Qm6oAWTGS_y_HT_FzKjefU5Q5cpfRPCCi7LczSjvKRcFPQC-bema_QwRsDQ2ZBM6AG7EHFq2tEPuoMwJhz6oTHaYxO2EKEzgIfQhq-o--0O685irxPErOnsaMBi58cQIZk_sgWdJn0L3XCFzpz2Ca6Pd44-nh7fVy_ZevP8ulquM5NX5ZDVVOuKcGugoJRwgEICBeq4mAoL7SwYWcpKVIYzaa0tHaGgy1rkxIja1WyO7g7ePoafEdKg2mZK4_2hjqoIkYKVYgLvD6CJIaUITvWxaXXcKUrUfl213CjO1GHdCb89ese6BfsPH-dkv4tMeGM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80096376</pqid></control><display><type>article</type><title>Miniature endoscope for simultaneous optical coherence tomography and laser-induced fluorescence measurement</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Tumlinson, Alexandre R ; Hariri, Lida P ; Utzinger, Urs ; Barton, Jennifer K</creator><creatorcontrib>Tumlinson, Alexandre R ; Hariri, Lida P ; Utzinger, Urs ; Barton, Jennifer K</creatorcontrib><description>We have designed a multimodality system that combines optical coherence tomography (OCT) and laser-induced fluorescence (LIF) in a 2.0-mm-diameter endoscopic package. OCT provides approximately 18-microm resolution cross-sectional structural information over a 6-mm field. LIF spectra are collected sequentially at submillimeter resolution across the same field and provide histochemical information about the tissue. We present the use of a rod prism to reduce the asymmetry in the OCT beam caused by a cylindrical window. The endoscope has been applied to investigate mouse colon cancer in vivo.</description><identifier>ISSN: 1559-128X</identifier><identifier>ISSN: 0003-6935</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/AO.43.000113</identifier><identifier>PMID: 14714651</identifier><language>eng</language><publisher>United States</publisher><subject>Animals ; Colonoscopes ; Colonoscopy ; Coloring Agents ; Endoscopes ; Equipment Design ; Fluorescence ; Lasers ; Mice ; Tomography, Optical Coherence - instrumentation</subject><ispartof>Applied Optics, 2004-01, Vol.43 (1), p.113-121</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c287t-b1aa804dce51104ee59e1e1f461366afdec979868c439ddd7f01ea7b620c6bfb3</citedby><cites>FETCH-LOGICAL-c287t-b1aa804dce51104ee59e1e1f461366afdec979868c439ddd7f01ea7b620c6bfb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/14714651$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tumlinson, Alexandre R</creatorcontrib><creatorcontrib>Hariri, Lida P</creatorcontrib><creatorcontrib>Utzinger, Urs</creatorcontrib><creatorcontrib>Barton, Jennifer K</creatorcontrib><title>Miniature endoscope for simultaneous optical coherence tomography and laser-induced fluorescence measurement</title><title>Applied Optics</title><addtitle>Appl Opt</addtitle><description>We have designed a multimodality system that combines optical coherence tomography (OCT) and laser-induced fluorescence (LIF) in a 2.0-mm-diameter endoscopic package. OCT provides approximately 18-microm resolution cross-sectional structural information over a 6-mm field. LIF spectra are collected sequentially at submillimeter resolution across the same field and provide histochemical information about the tissue. We present the use of a rod prism to reduce the asymmetry in the OCT beam caused by a cylindrical window. The endoscope has been applied to investigate mouse colon cancer in vivo.</description><subject>Animals</subject><subject>Colonoscopes</subject><subject>Colonoscopy</subject><subject>Coloring Agents</subject><subject>Endoscopes</subject><subject>Equipment Design</subject><subject>Fluorescence</subject><subject>Lasers</subject><subject>Mice</subject><subject>Tomography, Optical Coherence - instrumentation</subject><issn>1559-128X</issn><issn>0003-6935</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkD1PwzAURS0EolDYmJEnJlLs2HHisar4koq6gMRmOfYzDXLiYCdD_z0prcT03nB0dO9F6IaSBWWCPyw3C84WhBBK2Qm6oAWTGS_y_HT_FzKjefU5Q5cpfRPCCi7LczSjvKRcFPQC-bema_QwRsDQ2ZBM6AG7EHFq2tEPuoMwJhz6oTHaYxO2EKEzgIfQhq-o--0O685irxPErOnsaMBi58cQIZk_sgWdJn0L3XCFzpz2Ca6Pd44-nh7fVy_ZevP8ulquM5NX5ZDVVOuKcGugoJRwgEICBeq4mAoL7SwYWcpKVIYzaa0tHaGgy1rkxIja1WyO7g7ePoafEdKg2mZK4_2hjqoIkYKVYgLvD6CJIaUITvWxaXXcKUrUfl213CjO1GHdCb89ese6BfsPH-dkv4tMeGM</recordid><startdate>20040101</startdate><enddate>20040101</enddate><creator>Tumlinson, Alexandre R</creator><creator>Hariri, Lida P</creator><creator>Utzinger, Urs</creator><creator>Barton, Jennifer K</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20040101</creationdate><title>Miniature endoscope for simultaneous optical coherence tomography and laser-induced fluorescence measurement</title><author>Tumlinson, Alexandre R ; Hariri, Lida P ; Utzinger, Urs ; Barton, Jennifer K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c287t-b1aa804dce51104ee59e1e1f461366afdec979868c439ddd7f01ea7b620c6bfb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Animals</topic><topic>Colonoscopes</topic><topic>Colonoscopy</topic><topic>Coloring Agents</topic><topic>Endoscopes</topic><topic>Equipment Design</topic><topic>Fluorescence</topic><topic>Lasers</topic><topic>Mice</topic><topic>Tomography, Optical Coherence - instrumentation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tumlinson, Alexandre R</creatorcontrib><creatorcontrib>Hariri, Lida P</creatorcontrib><creatorcontrib>Utzinger, Urs</creatorcontrib><creatorcontrib>Barton, Jennifer K</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied Optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tumlinson, Alexandre R</au><au>Hariri, Lida P</au><au>Utzinger, Urs</au><au>Barton, Jennifer K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Miniature endoscope for simultaneous optical coherence tomography and laser-induced fluorescence measurement</atitle><jtitle>Applied Optics</jtitle><addtitle>Appl Opt</addtitle><date>2004-01-01</date><risdate>2004</risdate><volume>43</volume><issue>1</issue><spage>113</spage><epage>121</epage><pages>113-121</pages><issn>1559-128X</issn><issn>0003-6935</issn><eissn>1539-4522</eissn><abstract>We have designed a multimodality system that combines optical coherence tomography (OCT) and laser-induced fluorescence (LIF) in a 2.0-mm-diameter endoscopic package. OCT provides approximately 18-microm resolution cross-sectional structural information over a 6-mm field. LIF spectra are collected sequentially at submillimeter resolution across the same field and provide histochemical information about the tissue. We present the use of a rod prism to reduce the asymmetry in the OCT beam caused by a cylindrical window. The endoscope has been applied to investigate mouse colon cancer in vivo.</abstract><cop>United States</cop><pmid>14714651</pmid><doi>10.1364/AO.43.000113</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1559-128X |
ispartof | Applied Optics, 2004-01, Vol.43 (1), p.113-121 |
issn | 1559-128X 0003-6935 1539-4522 |
language | eng |
recordid | cdi_proquest_miscellaneous_80096376 |
source | MEDLINE; Alma/SFX Local Collection; Optica Publishing Group Journals |
subjects | Animals Colonoscopes Colonoscopy Coloring Agents Endoscopes Equipment Design Fluorescence Lasers Mice Tomography, Optical Coherence - instrumentation |
title | Miniature endoscope for simultaneous optical coherence tomography and laser-induced fluorescence measurement |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T19%3A11%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Miniature%20endoscope%20for%20simultaneous%20optical%20coherence%20tomography%20and%20laser-induced%20fluorescence%20measurement&rft.jtitle=Applied%20Optics&rft.au=Tumlinson,%20Alexandre%20R&rft.date=2004-01-01&rft.volume=43&rft.issue=1&rft.spage=113&rft.epage=121&rft.pages=113-121&rft.issn=1559-128X&rft.eissn=1539-4522&rft_id=info:doi/10.1364/AO.43.000113&rft_dat=%3Cproquest_cross%3E80096376%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80096376&rft_id=info:pmid/14714651&rfr_iscdi=true |