Oxygen Consumption in a Hollow Fiber Bioartificial Liver-Revisited

:  Oxygen consumption dynamics in a hollow fiber, hepatocyte‐loaded bioartificial liver are investigated both theoretically and experimentally. The theoretical model is based upon the Krogh cylinder, which approximates the bioreactor as a collection of cylindrical elements comprised of an inner fibe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Artificial organs 2004-01, Vol.28 (1), p.83-98
1. Verfasser: Patzer II, John F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 98
container_issue 1
container_start_page 83
container_title Artificial organs
container_volume 28
creator Patzer II, John F.
description :  Oxygen consumption dynamics in a hollow fiber, hepatocyte‐loaded bioartificial liver are investigated both theoretically and experimentally. The theoretical model is based upon the Krogh cylinder, which approximates the bioreactor as a collection of cylindrical elements comprised of an inner fiber lumen for media perfusion, the fiber wall through which oxygen can diffuse, and an annular region of hepatocytes surrounding the fiber. The primary non‐dimensional parameters that describe the system are: (i) the Peclet number, Pe, which is the ratio of convective oxygen transport through the lumen to diffusive oxygen transport to the fiber walls; (ii) the hepatocyte saturation parameter, θ, which is the ratio of the inlet oxygen partial pressure to the Michaelis‐Menten half‐rate oxygen partial pressure; (iii) the Thiele modulus, φ2, which is the ratio of oxygen consumption rate to oxygen diffusion rate in the hepatocyte annulus; (iv) the hepatocyte permeability ratio, β31, which is the ratio of oxygen permeability in the hepatocyte cell mass to oxygen permeability in the perfusing lumen medium; and (v) the hepatocyte annular thickness, ρ3, which is the ratio of the exterior hepatocyte annular radius to the fiber lumen radius. Only Pe and θ are easily manipulated operating variables. φ2, β31, and ρ3 are engineering design parameters that are set when a bioreactor is fabricated. The model results are expressed as the effective hepatocyte utilization ratio, Vratio, which is the ratio of the observed oxygen consumption rate to the intrinsic hepatocyte oxygen consumption rate. Large regions of Vratio > 0.9, which is deemed an acceptable effective hepatocyte utilization are found for parameter values consistent with standard hollow fiber cartridges used in bioartificial liver fabrication. The extent of the Vratio > 0.9 region increases to a plateau with increasing Pe, increases with increasing θ, decreases with increasing φ2, increases with increasing β31, and decreases with increasing ρ3. The theoretical results indicate that Vratio > 0.9 is found whenever the experimentally observed fractional oxygen consumption from the perfusing medium, , is less than 0.25. Combination of the theoretical and experimental results indicate that intrinsic, per cell oxygen consumption in the hollow fiber system may decrease as hepatocyte cell density increases and that this decrease may be due to lower intrinsic oxygen requirements in denser suspensions and not due to diffusion lim
doi_str_mv 10.1111/j.1525-1594.2004.07150.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80090982</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>17752280</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4340-67a9942785ea13c901c79ecf6a5469bdeb2125415c62c957277969c346bd61963</originalsourceid><addsrcrecordid>eNqNkE1PwjAYgBujUfz4C2Ynb5tvu36sBw9KRE2ICNHIrelKMcWxYTsE_r2bED1qL23S53nf5EEowpDg5lzOEswIizGTNCEANAGBGSTrPdT5-dhHHcAcYsbp-AgdhzADAEGBH6IjTAUBItMOuhmsN2-2jLpVGZbzRe2qMnJlpKP7qiiqVdRzufXRjau0r93UGaeLqO8-rY9H9tMFV9vJKTqY6iLYs919gl56t8_d-7g_uHvoXvdjQ1MKMRdaSkpExqzGqZGAjZDWTLlmlMt8YnOCCaOYGU6MZIIIIbk0KeX5hGPJ0xN0sZ278NXH0oZazV0wtih0aatlUBmABJmRP0EsBCMkgwbMtqDxVQjeTtXCu7n2G4VBtaHVTLU9VdtTtaHVd2i1btTz3Y5lPreTX3FXtgGutsDKFXbz78HqejBqX40fb30Xarv-8bV_V1ykgqnXxzvVGw-H2dO4p57TLy7vmXo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17752280</pqid></control><display><type>article</type><title>Oxygen Consumption in a Hollow Fiber Bioartificial Liver-Revisited</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Patzer II, John F.</creator><creatorcontrib>Patzer II, John F.</creatorcontrib><description>:  Oxygen consumption dynamics in a hollow fiber, hepatocyte‐loaded bioartificial liver are investigated both theoretically and experimentally. The theoretical model is based upon the Krogh cylinder, which approximates the bioreactor as a collection of cylindrical elements comprised of an inner fiber lumen for media perfusion, the fiber wall through which oxygen can diffuse, and an annular region of hepatocytes surrounding the fiber. The primary non‐dimensional parameters that describe the system are: (i) the Peclet number, Pe, which is the ratio of convective oxygen transport through the lumen to diffusive oxygen transport to the fiber walls; (ii) the hepatocyte saturation parameter, θ, which is the ratio of the inlet oxygen partial pressure to the Michaelis‐Menten half‐rate oxygen partial pressure; (iii) the Thiele modulus, φ2, which is the ratio of oxygen consumption rate to oxygen diffusion rate in the hepatocyte annulus; (iv) the hepatocyte permeability ratio, β31, which is the ratio of oxygen permeability in the hepatocyte cell mass to oxygen permeability in the perfusing lumen medium; and (v) the hepatocyte annular thickness, ρ3, which is the ratio of the exterior hepatocyte annular radius to the fiber lumen radius. Only Pe and θ are easily manipulated operating variables. φ2, β31, and ρ3 are engineering design parameters that are set when a bioreactor is fabricated. The model results are expressed as the effective hepatocyte utilization ratio, Vratio, which is the ratio of the observed oxygen consumption rate to the intrinsic hepatocyte oxygen consumption rate. Large regions of Vratio &gt; 0.9, which is deemed an acceptable effective hepatocyte utilization are found for parameter values consistent with standard hollow fiber cartridges used in bioartificial liver fabrication. The extent of the Vratio &gt; 0.9 region increases to a plateau with increasing Pe, increases with increasing θ, decreases with increasing φ2, increases with increasing β31, and decreases with increasing ρ3. The theoretical results indicate that Vratio &gt; 0.9 is found whenever the experimentally observed fractional oxygen consumption from the perfusing medium, , is less than 0.25. Combination of the theoretical and experimental results indicate that intrinsic, per cell oxygen consumption in the hollow fiber system may decrease as hepatocyte cell density increases and that this decrease may be due to lower intrinsic oxygen requirements in denser suspensions and not due to diffusion limitations in oxygen transport in the hollow fiber system as might be expected from two‐dimensional, monolayer culture oxygen consumption measurements.</description><identifier>ISSN: 0160-564X</identifier><identifier>EISSN: 1525-1594</identifier><identifier>DOI: 10.1111/j.1525-1594.2004.07150.x</identifier><identifier>PMID: 14720293</identifier><language>eng</language><publisher>Oxford, UK and Malden, USA: Blackwell Science Inc</publisher><subject>Animals ; Bioartificial liver ; Bioreactors ; Hepatocytes ; Hepatocytes - metabolism ; Liver, Artificial ; Mathematical model ; Models, Biological ; Oxygen Consumption - physiology ; Oxygen metabolism ; Swine</subject><ispartof>Artificial organs, 2004-01, Vol.28 (1), p.83-98</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4340-67a9942785ea13c901c79ecf6a5469bdeb2125415c62c957277969c346bd61963</citedby><cites>FETCH-LOGICAL-c4340-67a9942785ea13c901c79ecf6a5469bdeb2125415c62c957277969c346bd61963</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1525-1594.2004.07150.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1525-1594.2004.07150.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/14720293$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Patzer II, John F.</creatorcontrib><title>Oxygen Consumption in a Hollow Fiber Bioartificial Liver-Revisited</title><title>Artificial organs</title><addtitle>Artif Organs</addtitle><description>:  Oxygen consumption dynamics in a hollow fiber, hepatocyte‐loaded bioartificial liver are investigated both theoretically and experimentally. The theoretical model is based upon the Krogh cylinder, which approximates the bioreactor as a collection of cylindrical elements comprised of an inner fiber lumen for media perfusion, the fiber wall through which oxygen can diffuse, and an annular region of hepatocytes surrounding the fiber. The primary non‐dimensional parameters that describe the system are: (i) the Peclet number, Pe, which is the ratio of convective oxygen transport through the lumen to diffusive oxygen transport to the fiber walls; (ii) the hepatocyte saturation parameter, θ, which is the ratio of the inlet oxygen partial pressure to the Michaelis‐Menten half‐rate oxygen partial pressure; (iii) the Thiele modulus, φ2, which is the ratio of oxygen consumption rate to oxygen diffusion rate in the hepatocyte annulus; (iv) the hepatocyte permeability ratio, β31, which is the ratio of oxygen permeability in the hepatocyte cell mass to oxygen permeability in the perfusing lumen medium; and (v) the hepatocyte annular thickness, ρ3, which is the ratio of the exterior hepatocyte annular radius to the fiber lumen radius. Only Pe and θ are easily manipulated operating variables. φ2, β31, and ρ3 are engineering design parameters that are set when a bioreactor is fabricated. The model results are expressed as the effective hepatocyte utilization ratio, Vratio, which is the ratio of the observed oxygen consumption rate to the intrinsic hepatocyte oxygen consumption rate. Large regions of Vratio &gt; 0.9, which is deemed an acceptable effective hepatocyte utilization are found for parameter values consistent with standard hollow fiber cartridges used in bioartificial liver fabrication. The extent of the Vratio &gt; 0.9 region increases to a plateau with increasing Pe, increases with increasing θ, decreases with increasing φ2, increases with increasing β31, and decreases with increasing ρ3. The theoretical results indicate that Vratio &gt; 0.9 is found whenever the experimentally observed fractional oxygen consumption from the perfusing medium, , is less than 0.25. Combination of the theoretical and experimental results indicate that intrinsic, per cell oxygen consumption in the hollow fiber system may decrease as hepatocyte cell density increases and that this decrease may be due to lower intrinsic oxygen requirements in denser suspensions and not due to diffusion limitations in oxygen transport in the hollow fiber system as might be expected from two‐dimensional, monolayer culture oxygen consumption measurements.</description><subject>Animals</subject><subject>Bioartificial liver</subject><subject>Bioreactors</subject><subject>Hepatocytes</subject><subject>Hepatocytes - metabolism</subject><subject>Liver, Artificial</subject><subject>Mathematical model</subject><subject>Models, Biological</subject><subject>Oxygen Consumption - physiology</subject><subject>Oxygen metabolism</subject><subject>Swine</subject><issn>0160-564X</issn><issn>1525-1594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkE1PwjAYgBujUfz4C2Ynb5tvu36sBw9KRE2ICNHIrelKMcWxYTsE_r2bED1qL23S53nf5EEowpDg5lzOEswIizGTNCEANAGBGSTrPdT5-dhHHcAcYsbp-AgdhzADAEGBH6IjTAUBItMOuhmsN2-2jLpVGZbzRe2qMnJlpKP7qiiqVdRzufXRjau0r93UGaeLqO8-rY9H9tMFV9vJKTqY6iLYs919gl56t8_d-7g_uHvoXvdjQ1MKMRdaSkpExqzGqZGAjZDWTLlmlMt8YnOCCaOYGU6MZIIIIbk0KeX5hGPJ0xN0sZ278NXH0oZazV0wtih0aatlUBmABJmRP0EsBCMkgwbMtqDxVQjeTtXCu7n2G4VBtaHVTLU9VdtTtaHVd2i1btTz3Y5lPreTX3FXtgGutsDKFXbz78HqejBqX40fb30Xarv-8bV_V1ykgqnXxzvVGw-H2dO4p57TLy7vmXo</recordid><startdate>200401</startdate><enddate>200401</enddate><creator>Patzer II, John F.</creator><general>Blackwell Science Inc</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>200401</creationdate><title>Oxygen Consumption in a Hollow Fiber Bioartificial Liver-Revisited</title><author>Patzer II, John F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4340-67a9942785ea13c901c79ecf6a5469bdeb2125415c62c957277969c346bd61963</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Animals</topic><topic>Bioartificial liver</topic><topic>Bioreactors</topic><topic>Hepatocytes</topic><topic>Hepatocytes - metabolism</topic><topic>Liver, Artificial</topic><topic>Mathematical model</topic><topic>Models, Biological</topic><topic>Oxygen Consumption - physiology</topic><topic>Oxygen metabolism</topic><topic>Swine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Patzer II, John F.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Artificial organs</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Patzer II, John F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Oxygen Consumption in a Hollow Fiber Bioartificial Liver-Revisited</atitle><jtitle>Artificial organs</jtitle><addtitle>Artif Organs</addtitle><date>2004-01</date><risdate>2004</risdate><volume>28</volume><issue>1</issue><spage>83</spage><epage>98</epage><pages>83-98</pages><issn>0160-564X</issn><eissn>1525-1594</eissn><abstract>:  Oxygen consumption dynamics in a hollow fiber, hepatocyte‐loaded bioartificial liver are investigated both theoretically and experimentally. The theoretical model is based upon the Krogh cylinder, which approximates the bioreactor as a collection of cylindrical elements comprised of an inner fiber lumen for media perfusion, the fiber wall through which oxygen can diffuse, and an annular region of hepatocytes surrounding the fiber. The primary non‐dimensional parameters that describe the system are: (i) the Peclet number, Pe, which is the ratio of convective oxygen transport through the lumen to diffusive oxygen transport to the fiber walls; (ii) the hepatocyte saturation parameter, θ, which is the ratio of the inlet oxygen partial pressure to the Michaelis‐Menten half‐rate oxygen partial pressure; (iii) the Thiele modulus, φ2, which is the ratio of oxygen consumption rate to oxygen diffusion rate in the hepatocyte annulus; (iv) the hepatocyte permeability ratio, β31, which is the ratio of oxygen permeability in the hepatocyte cell mass to oxygen permeability in the perfusing lumen medium; and (v) the hepatocyte annular thickness, ρ3, which is the ratio of the exterior hepatocyte annular radius to the fiber lumen radius. Only Pe and θ are easily manipulated operating variables. φ2, β31, and ρ3 are engineering design parameters that are set when a bioreactor is fabricated. The model results are expressed as the effective hepatocyte utilization ratio, Vratio, which is the ratio of the observed oxygen consumption rate to the intrinsic hepatocyte oxygen consumption rate. Large regions of Vratio &gt; 0.9, which is deemed an acceptable effective hepatocyte utilization are found for parameter values consistent with standard hollow fiber cartridges used in bioartificial liver fabrication. The extent of the Vratio &gt; 0.9 region increases to a plateau with increasing Pe, increases with increasing θ, decreases with increasing φ2, increases with increasing β31, and decreases with increasing ρ3. The theoretical results indicate that Vratio &gt; 0.9 is found whenever the experimentally observed fractional oxygen consumption from the perfusing medium, , is less than 0.25. Combination of the theoretical and experimental results indicate that intrinsic, per cell oxygen consumption in the hollow fiber system may decrease as hepatocyte cell density increases and that this decrease may be due to lower intrinsic oxygen requirements in denser suspensions and not due to diffusion limitations in oxygen transport in the hollow fiber system as might be expected from two‐dimensional, monolayer culture oxygen consumption measurements.</abstract><cop>Oxford, UK and Malden, USA</cop><pub>Blackwell Science Inc</pub><pmid>14720293</pmid><doi>10.1111/j.1525-1594.2004.07150.x</doi><tpages>16</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0160-564X
ispartof Artificial organs, 2004-01, Vol.28 (1), p.83-98
issn 0160-564X
1525-1594
language eng
recordid cdi_proquest_miscellaneous_80090982
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects Animals
Bioartificial liver
Bioreactors
Hepatocytes
Hepatocytes - metabolism
Liver, Artificial
Mathematical model
Models, Biological
Oxygen Consumption - physiology
Oxygen metabolism
Swine
title Oxygen Consumption in a Hollow Fiber Bioartificial Liver-Revisited
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T13%3A54%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Oxygen%20Consumption%20in%20a%20Hollow%20Fiber%20Bioartificial%20Liver-Revisited&rft.jtitle=Artificial%20organs&rft.au=Patzer%20II,%20John%20F.&rft.date=2004-01&rft.volume=28&rft.issue=1&rft.spage=83&rft.epage=98&rft.pages=83-98&rft.issn=0160-564X&rft.eissn=1525-1594&rft_id=info:doi/10.1111/j.1525-1594.2004.07150.x&rft_dat=%3Cproquest_cross%3E17752280%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=17752280&rft_id=info:pmid/14720293&rfr_iscdi=true