Microleakage of a new cavity varnish with a high-copper spherical amalgam alloy
In a study in vitro Copalite and Barrier cavity varnishes were applied to the walls of class 1 prepared cavities before placing Tytin, a high-copper amalgam. Tests with 45Ca and autoradiographs showed that at six months only Copalite was effective in preventing microleakage. At one year neither Barr...
Gespeichert in:
Veröffentlicht in: | Operative dentistry 1990-07, Vol.15 (4), p.136-140 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 140 |
---|---|
container_issue | 4 |
container_start_page | 136 |
container_title | Operative dentistry |
container_volume | 15 |
creator | Fitchie, J G Reeves, G W Scarbrough, A R Hembree, J H |
description | In a study in vitro Copalite and Barrier cavity varnishes were applied to the walls of class 1 prepared cavities before placing Tytin, a high-copper amalgam. Tests with 45Ca and autoradiographs showed that at six months only Copalite was effective in preventing microleakage. At one year neither Barrier nor Copalite was preventing leakage. |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_80050311</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80050311</sourcerecordid><originalsourceid>FETCH-LOGICAL-p206t-fc17e5c7d47d88de57dc2c59f6093c7afd0ad4a0478d23fc31bbf5ac883e55353</originalsourceid><addsrcrecordid>eNotkL1OwzAYRT2ASik8ApIntkh2HMfJiCr-pKIuMEdf7M-JwfnBTlrl7alEpjPcozucK7JlIueJUiK7IbcxfjOWyUzKDdmkKc9Llm_J8cPpMHiEH2iQDpYC7fFMNZzctNAThN7Flp7d1F6W1jVtoodxxEDj2GJwGjyFDnwDHQXvh-WOXFvwEe9X7sjXy_Pn_i05HF_f90-HZExZPiVWc4VSK5MpUxQGpTI61bK0OSuFVmANA5MBy1RhUmG14HVtJeiiECilkGJHHv9_xzD8zhinqnNRo_fQ4zDHqmBMMsH5RXxYxbnu0FRjcB2EpVoLiD_1UFcm</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80050311</pqid></control><display><type>article</type><title>Microleakage of a new cavity varnish with a high-copper spherical amalgam alloy</title><source>MEDLINE</source><source>Allen Press Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Fitchie, J G ; Reeves, G W ; Scarbrough, A R ; Hembree, J H</creator><creatorcontrib>Fitchie, J G ; Reeves, G W ; Scarbrough, A R ; Hembree, J H</creatorcontrib><description>In a study in vitro Copalite and Barrier cavity varnishes were applied to the walls of class 1 prepared cavities before placing Tytin, a high-copper amalgam. Tests with 45Ca and autoradiographs showed that at six months only Copalite was effective in preventing microleakage. At one year neither Barrier nor Copalite was preventing leakage.</description><identifier>ISSN: 0361-7734</identifier><identifier>PMID: 2216906</identifier><language>eng</language><publisher>United States</publisher><subject>Copper ; Dental Alloys ; Dental Amalgam ; Dental Cavity Lining ; Dental Leakage - prevention & control ; Dentistry ; Humans ; Molar</subject><ispartof>Operative dentistry, 1990-07, Vol.15 (4), p.136-140</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2216906$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fitchie, J G</creatorcontrib><creatorcontrib>Reeves, G W</creatorcontrib><creatorcontrib>Scarbrough, A R</creatorcontrib><creatorcontrib>Hembree, J H</creatorcontrib><title>Microleakage of a new cavity varnish with a high-copper spherical amalgam alloy</title><title>Operative dentistry</title><addtitle>Oper Dent</addtitle><description>In a study in vitro Copalite and Barrier cavity varnishes were applied to the walls of class 1 prepared cavities before placing Tytin, a high-copper amalgam. Tests with 45Ca and autoradiographs showed that at six months only Copalite was effective in preventing microleakage. At one year neither Barrier nor Copalite was preventing leakage.</description><subject>Copper</subject><subject>Dental Alloys</subject><subject>Dental Amalgam</subject><subject>Dental Cavity Lining</subject><subject>Dental Leakage - prevention & control</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Molar</subject><issn>0361-7734</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNotkL1OwzAYRT2ASik8ApIntkh2HMfJiCr-pKIuMEdf7M-JwfnBTlrl7alEpjPcozucK7JlIueJUiK7IbcxfjOWyUzKDdmkKc9Llm_J8cPpMHiEH2iQDpYC7fFMNZzctNAThN7Flp7d1F6W1jVtoodxxEDj2GJwGjyFDnwDHQXvh-WOXFvwEe9X7sjXy_Pn_i05HF_f90-HZExZPiVWc4VSK5MpUxQGpTI61bK0OSuFVmANA5MBy1RhUmG14HVtJeiiECilkGJHHv9_xzD8zhinqnNRo_fQ4zDHqmBMMsH5RXxYxbnu0FRjcB2EpVoLiD_1UFcm</recordid><startdate>199007</startdate><enddate>199007</enddate><creator>Fitchie, J G</creator><creator>Reeves, G W</creator><creator>Scarbrough, A R</creator><creator>Hembree, J H</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>199007</creationdate><title>Microleakage of a new cavity varnish with a high-copper spherical amalgam alloy</title><author>Fitchie, J G ; Reeves, G W ; Scarbrough, A R ; Hembree, J H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p206t-fc17e5c7d47d88de57dc2c59f6093c7afd0ad4a0478d23fc31bbf5ac883e55353</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Copper</topic><topic>Dental Alloys</topic><topic>Dental Amalgam</topic><topic>Dental Cavity Lining</topic><topic>Dental Leakage - prevention & control</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Molar</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fitchie, J G</creatorcontrib><creatorcontrib>Reeves, G W</creatorcontrib><creatorcontrib>Scarbrough, A R</creatorcontrib><creatorcontrib>Hembree, J H</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Operative dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fitchie, J G</au><au>Reeves, G W</au><au>Scarbrough, A R</au><au>Hembree, J H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microleakage of a new cavity varnish with a high-copper spherical amalgam alloy</atitle><jtitle>Operative dentistry</jtitle><addtitle>Oper Dent</addtitle><date>1990-07</date><risdate>1990</risdate><volume>15</volume><issue>4</issue><spage>136</spage><epage>140</epage><pages>136-140</pages><issn>0361-7734</issn><abstract>In a study in vitro Copalite and Barrier cavity varnishes were applied to the walls of class 1 prepared cavities before placing Tytin, a high-copper amalgam. Tests with 45Ca and autoradiographs showed that at six months only Copalite was effective in preventing microleakage. At one year neither Barrier nor Copalite was preventing leakage.</abstract><cop>United States</cop><pmid>2216906</pmid><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0361-7734 |
ispartof | Operative dentistry, 1990-07, Vol.15 (4), p.136-140 |
issn | 0361-7734 |
language | eng |
recordid | cdi_proquest_miscellaneous_80050311 |
source | MEDLINE; Allen Press Journals; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection |
subjects | Copper Dental Alloys Dental Amalgam Dental Cavity Lining Dental Leakage - prevention & control Dentistry Humans Molar |
title | Microleakage of a new cavity varnish with a high-copper spherical amalgam alloy |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T05%3A13%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microleakage%20of%20a%20new%20cavity%20varnish%20with%20a%20high-copper%20spherical%20amalgam%20alloy&rft.jtitle=Operative%20dentistry&rft.au=Fitchie,%20J%20G&rft.date=1990-07&rft.volume=15&rft.issue=4&rft.spage=136&rft.epage=140&rft.pages=136-140&rft.issn=0361-7734&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E80050311%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80050311&rft_id=info:pmid/2216906&rfr_iscdi=true |