FTIR/ATR for protein adsorption to biomaterial surfaces

It is now well accepted that the initial rapid adsorption of blood proteins to biomaterial surfaces is important in the long-term performance of the implant. Cells that interact with the implant will be reacting to a layer (single or multiple) of adsorbed protein. The parameters of importance in a s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomaterials 1998-03, Vol.19 (4), p.357-369
1. Verfasser: Chittur, Krishnan K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 369
container_issue 4
container_start_page 357
container_title Biomaterials
container_volume 19
creator Chittur, Krishnan K.
description It is now well accepted that the initial rapid adsorption of blood proteins to biomaterial surfaces is important in the long-term performance of the implant. Cells that interact with the implant will be reacting to a layer (single or multiple) of adsorbed protein. The parameters of importance in a study of protein adsorption to surfaces of biomaterial interest include total amounts of different adsorbed proteins and the conformation and orientation of these adsorbed proteins. Researchers have developed a number of techniques with which we can now address all these questions. In this paper, we have discussed how Fourier transform infrared (FTIR) attenuated total internal reflection (ATR) techniques can be used for the study of biomaterial surfaces and events at biomaterial surfaces such as protein adsorption. FTIR spectroscopy offers higher signal-to-noise and speeds than spectrometers that use gratings and hence offers the capability of observing the critical early events when proteins interact with surfaces. Perhaps the biggest advantage of the FTIR technique over dispersive spectrometers is wavelength precision. This allows the subtraction of water, a strong infrared absorber, from the spectra of proteins in aqueous solutions. This review starts with an introduction of how ATR can be used to provide information about proteins on surfaces. Equations to calculate the amount of proteins adsorbed to surfaces from analysis of ATR spectra are presented. A discussion of the kinds of surfaces that can be analyzed by FTIR/ATR and difficulties with the subtraction of H 2O is given. The rest of the review deals with how information of interest to biomaterials researchers such as kinetics of protein adsorption, changes in protein secondary structure and orientation upon adsorption to surfaces can be obtained by FTIR/ATR.
doi_str_mv 10.1016/S0142-9612(97)00223-8
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80028003</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0142961297002238</els_id><sourcerecordid>80028003</sourcerecordid><originalsourceid>FETCH-LOGICAL-c457t-b3852bceb2c4ad0daa774f5bb3dc81a4b879feefd75f4c1c66549e64c31ba5cf3</originalsourceid><addsrcrecordid>eNqFkN9LwzAQx4Moc07_hEGfRB_qkjRp2icZw-lgIMz5HJL0ApG2mUkr-N_b_WCvPhzHcd-7790HoSnBTwSTfPaBCaNpmRP6UIpHjCnN0uICjUkhipSXmF-i8VlyjW5i_MJDjRkdoVGZC0E4HiOx3K42s_l2k1gfkl3wHbg2UVX0Ydc53yadT7TzjeogOFUnsQ9WGYi36MqqOsLdKU_Q5_Jlu3hL1--vq8V8nRrGRZfqrOBUG9DUMFXhSikhmOVaZ5UpiGK6EKUFsJXglhli8pyzEnJmMqIVNzaboPvj3uG07x5iJxsXDdS1asH3URbD40Nk_wopyXJR5nQQ8qPQBB9jACt3wTUq_EqC5Z6sPJCVe2yyFPJAVhbD3PRk0OsGqvPUCeXQfz72YcDx4yDIaBy0BioXwHSy8u4fhz8gNogL</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21367962</pqid></control><display><type>article</type><title>FTIR/ATR for protein adsorption to biomaterial surfaces</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Chittur, Krishnan K.</creator><creatorcontrib>Chittur, Krishnan K.</creatorcontrib><description>It is now well accepted that the initial rapid adsorption of blood proteins to biomaterial surfaces is important in the long-term performance of the implant. Cells that interact with the implant will be reacting to a layer (single or multiple) of adsorbed protein. The parameters of importance in a study of protein adsorption to surfaces of biomaterial interest include total amounts of different adsorbed proteins and the conformation and orientation of these adsorbed proteins. Researchers have developed a number of techniques with which we can now address all these questions. In this paper, we have discussed how Fourier transform infrared (FTIR) attenuated total internal reflection (ATR) techniques can be used for the study of biomaterial surfaces and events at biomaterial surfaces such as protein adsorption. FTIR spectroscopy offers higher signal-to-noise and speeds than spectrometers that use gratings and hence offers the capability of observing the critical early events when proteins interact with surfaces. Perhaps the biggest advantage of the FTIR technique over dispersive spectrometers is wavelength precision. This allows the subtraction of water, a strong infrared absorber, from the spectra of proteins in aqueous solutions. This review starts with an introduction of how ATR can be used to provide information about proteins on surfaces. Equations to calculate the amount of proteins adsorbed to surfaces from analysis of ATR spectra are presented. A discussion of the kinds of surfaces that can be analyzed by FTIR/ATR and difficulties with the subtraction of H 2O is given. The rest of the review deals with how information of interest to biomaterials researchers such as kinetics of protein adsorption, changes in protein secondary structure and orientation upon adsorption to surfaces can be obtained by FTIR/ATR.</description><identifier>ISSN: 0142-9612</identifier><identifier>EISSN: 1878-5905</identifier><identifier>DOI: 10.1016/S0142-9612(97)00223-8</identifier><identifier>PMID: 9677150</identifier><language>eng</language><publisher>Netherlands: Elsevier Ltd</publisher><subject>Adsorption ; Biocompatible Materials - chemistry ; Cells ; Electrochemistry - methods ; Fourier transform infrared spectroscopy ; Interferometry - methods ; Light ; Models, Molecular ; Models, Theoretical ; Protein Conformation ; Protein Structure, Secondary ; Proteins ; Proteins - chemistry ; Signal to noise ratio ; Spectroscopy, Fourier Transform Infrared - methods ; Surface properties</subject><ispartof>Biomaterials, 1998-03, Vol.19 (4), p.357-369</ispartof><rights>1998</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c457t-b3852bceb2c4ad0daa774f5bb3dc81a4b879feefd75f4c1c66549e64c31ba5cf3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0142-9612(97)00223-8$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9677150$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chittur, Krishnan K.</creatorcontrib><title>FTIR/ATR for protein adsorption to biomaterial surfaces</title><title>Biomaterials</title><addtitle>Biomaterials</addtitle><description>It is now well accepted that the initial rapid adsorption of blood proteins to biomaterial surfaces is important in the long-term performance of the implant. Cells that interact with the implant will be reacting to a layer (single or multiple) of adsorbed protein. The parameters of importance in a study of protein adsorption to surfaces of biomaterial interest include total amounts of different adsorbed proteins and the conformation and orientation of these adsorbed proteins. Researchers have developed a number of techniques with which we can now address all these questions. In this paper, we have discussed how Fourier transform infrared (FTIR) attenuated total internal reflection (ATR) techniques can be used for the study of biomaterial surfaces and events at biomaterial surfaces such as protein adsorption. FTIR spectroscopy offers higher signal-to-noise and speeds than spectrometers that use gratings and hence offers the capability of observing the critical early events when proteins interact with surfaces. Perhaps the biggest advantage of the FTIR technique over dispersive spectrometers is wavelength precision. This allows the subtraction of water, a strong infrared absorber, from the spectra of proteins in aqueous solutions. This review starts with an introduction of how ATR can be used to provide information about proteins on surfaces. Equations to calculate the amount of proteins adsorbed to surfaces from analysis of ATR spectra are presented. A discussion of the kinds of surfaces that can be analyzed by FTIR/ATR and difficulties with the subtraction of H 2O is given. The rest of the review deals with how information of interest to biomaterials researchers such as kinetics of protein adsorption, changes in protein secondary structure and orientation upon adsorption to surfaces can be obtained by FTIR/ATR.</description><subject>Adsorption</subject><subject>Biocompatible Materials - chemistry</subject><subject>Cells</subject><subject>Electrochemistry - methods</subject><subject>Fourier transform infrared spectroscopy</subject><subject>Interferometry - methods</subject><subject>Light</subject><subject>Models, Molecular</subject><subject>Models, Theoretical</subject><subject>Protein Conformation</subject><subject>Protein Structure, Secondary</subject><subject>Proteins</subject><subject>Proteins - chemistry</subject><subject>Signal to noise ratio</subject><subject>Spectroscopy, Fourier Transform Infrared - methods</subject><subject>Surface properties</subject><issn>0142-9612</issn><issn>1878-5905</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkN9LwzAQx4Moc07_hEGfRB_qkjRp2icZw-lgIMz5HJL0ApG2mUkr-N_b_WCvPhzHcd-7790HoSnBTwSTfPaBCaNpmRP6UIpHjCnN0uICjUkhipSXmF-i8VlyjW5i_MJDjRkdoVGZC0E4HiOx3K42s_l2k1gfkl3wHbg2UVX0Ydc53yadT7TzjeogOFUnsQ9WGYi36MqqOsLdKU_Q5_Jlu3hL1--vq8V8nRrGRZfqrOBUG9DUMFXhSikhmOVaZ5UpiGK6EKUFsJXglhli8pyzEnJmMqIVNzaboPvj3uG07x5iJxsXDdS1asH3URbD40Nk_wopyXJR5nQQ8qPQBB9jACt3wTUq_EqC5Z6sPJCVe2yyFPJAVhbD3PRk0OsGqvPUCeXQfz72YcDx4yDIaBy0BioXwHSy8u4fhz8gNogL</recordid><startdate>19980301</startdate><enddate>19980301</enddate><creator>Chittur, Krishnan K.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19980301</creationdate><title>FTIR/ATR for protein adsorption to biomaterial surfaces</title><author>Chittur, Krishnan K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c457t-b3852bceb2c4ad0daa774f5bb3dc81a4b879feefd75f4c1c66549e64c31ba5cf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Adsorption</topic><topic>Biocompatible Materials - chemistry</topic><topic>Cells</topic><topic>Electrochemistry - methods</topic><topic>Fourier transform infrared spectroscopy</topic><topic>Interferometry - methods</topic><topic>Light</topic><topic>Models, Molecular</topic><topic>Models, Theoretical</topic><topic>Protein Conformation</topic><topic>Protein Structure, Secondary</topic><topic>Proteins</topic><topic>Proteins - chemistry</topic><topic>Signal to noise ratio</topic><topic>Spectroscopy, Fourier Transform Infrared - methods</topic><topic>Surface properties</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chittur, Krishnan K.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Biomaterials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chittur, Krishnan K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>FTIR/ATR for protein adsorption to biomaterial surfaces</atitle><jtitle>Biomaterials</jtitle><addtitle>Biomaterials</addtitle><date>1998-03-01</date><risdate>1998</risdate><volume>19</volume><issue>4</issue><spage>357</spage><epage>369</epage><pages>357-369</pages><issn>0142-9612</issn><eissn>1878-5905</eissn><abstract>It is now well accepted that the initial rapid adsorption of blood proteins to biomaterial surfaces is important in the long-term performance of the implant. Cells that interact with the implant will be reacting to a layer (single or multiple) of adsorbed protein. The parameters of importance in a study of protein adsorption to surfaces of biomaterial interest include total amounts of different adsorbed proteins and the conformation and orientation of these adsorbed proteins. Researchers have developed a number of techniques with which we can now address all these questions. In this paper, we have discussed how Fourier transform infrared (FTIR) attenuated total internal reflection (ATR) techniques can be used for the study of biomaterial surfaces and events at biomaterial surfaces such as protein adsorption. FTIR spectroscopy offers higher signal-to-noise and speeds than spectrometers that use gratings and hence offers the capability of observing the critical early events when proteins interact with surfaces. Perhaps the biggest advantage of the FTIR technique over dispersive spectrometers is wavelength precision. This allows the subtraction of water, a strong infrared absorber, from the spectra of proteins in aqueous solutions. This review starts with an introduction of how ATR can be used to provide information about proteins on surfaces. Equations to calculate the amount of proteins adsorbed to surfaces from analysis of ATR spectra are presented. A discussion of the kinds of surfaces that can be analyzed by FTIR/ATR and difficulties with the subtraction of H 2O is given. The rest of the review deals with how information of interest to biomaterials researchers such as kinetics of protein adsorption, changes in protein secondary structure and orientation upon adsorption to surfaces can be obtained by FTIR/ATR.</abstract><cop>Netherlands</cop><pub>Elsevier Ltd</pub><pmid>9677150</pmid><doi>10.1016/S0142-9612(97)00223-8</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0142-9612
ispartof Biomaterials, 1998-03, Vol.19 (4), p.357-369
issn 0142-9612
1878-5905
language eng
recordid cdi_proquest_miscellaneous_80028003
source MEDLINE; Elsevier ScienceDirect Journals
subjects Adsorption
Biocompatible Materials - chemistry
Cells
Electrochemistry - methods
Fourier transform infrared spectroscopy
Interferometry - methods
Light
Models, Molecular
Models, Theoretical
Protein Conformation
Protein Structure, Secondary
Proteins
Proteins - chemistry
Signal to noise ratio
Spectroscopy, Fourier Transform Infrared - methods
Surface properties
title FTIR/ATR for protein adsorption to biomaterial surfaces
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T22%3A36%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=FTIR/ATR%20for%20protein%20adsorption%20to%20biomaterial%20surfaces&rft.jtitle=Biomaterials&rft.au=Chittur,%20Krishnan%20K.&rft.date=1998-03-01&rft.volume=19&rft.issue=4&rft.spage=357&rft.epage=369&rft.pages=357-369&rft.issn=0142-9612&rft.eissn=1878-5905&rft_id=info:doi/10.1016/S0142-9612(97)00223-8&rft_dat=%3Cproquest_cross%3E80028003%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=21367962&rft_id=info:pmid/9677150&rft_els_id=S0142961297002238&rfr_iscdi=true