The Effects of Ventricular Pacing on Left Ventricular Geometry, Function, Myocardial Oxygen Consumption, and Efficiency of Contraction in Conscious Dogs

The effects of ventricular pacing on left ventricular (LV) dynamic geometry, function, and myocardial oxygen consumption (MVO2) were measured in 12 conscious dogs using sonomicrometry, micromanometry, ultrasonic flow probes, and oximetry catheters during right atrial (A‐) and right ventricular (V‐)...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pacing and clinical electrophysiology 1998-07, Vol.21 (7), p.1417-1429
Hauptverfasser: OWEN, CLARENCE H., ESPOSITO, DAVID J., DAVIS, JAMES W., GLOWER, DONALD D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1429
container_issue 7
container_start_page 1417
container_title Pacing and clinical electrophysiology
container_volume 21
creator OWEN, CLARENCE H.
ESPOSITO, DAVID J.
DAVIS, JAMES W.
GLOWER, DONALD D.
description The effects of ventricular pacing on left ventricular (LV) dynamic geometry, function, and myocardial oxygen consumption (MVO2) were measured in 12 conscious dogs using sonomicrometry, micromanometry, ultrasonic flow probes, and oximetry catheters during right atrial (A‐) and right ventricular (V‐) pacing at 150 beats/mm. Systolic function was quantified using slopes (Mw) and volume‐intercepts (Vw) of linear relationships between end‐di‐astolic volume (EDV) and stroke work (SW) for data obtained during vena caval occlusion. V‐pacing shifted SW‐EDV relationships downward (Mw decreased from 97 ± 21 to 81 ± 21 Kerg/mL) and to the right (Vw increased from 14 ± 11 to 20 ± 12 mL) in comparison with A‐pacing (P < 0.05). These functional changes correlated with altered contractile geometry manifest as early shortening in the septal free wall relative to anterior‐posterior dimension (increased minor axis mid‐wall eccentricity at end‐diastole and begin‐ejection). Steady‐state LV power output decreased from 802 ± 213 mW during A‐pacing to 514 ± 170 mW during V‐pacing (P < 0.05), while MVO2 remained relatively unchanged during V‐pacing (10 ± 3 mL O2/min vs 11 ± 3 mL O2/min during A‐pacing, P = NS). As a result, overall LV efficiency decreased from 0.24 ± 0.08 during A‐pacing to 0.16 ± 0.06 during V‐pacing (P < 0.05). These data illustrate the impact of V‐pacing on dynamic LV geometry and function, including impaired LV work output at all physiological levels of preload. Most importantly, the relationship between LV work output and MVO2 is depressed during V‐pacing, emphasizing the interaction between LV mechanics and pump efficiency in intact subjects. As a result, measures taken to restore normal contractile geometry might improve LV efficiency and performance when V‐pacing is necessary.
doi_str_mv 10.1111/j.1540-8159.1998.tb00213.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80019292</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80019292</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4097-1274cd443eaac0d9690564923269c7a27d98984b72eec35b54441bc885e213d93</originalsourceid><addsrcrecordid>eNqVkcGO0zAURS0EGkrhE5AsFqwmwU6c2GbFUDoFqcMUaQCJjeU6L8UliYudaJo_mc8lIVUllnjjxXn3vqd7EXpFSUyH92Yf04yRSNBMxlRKEbdbQhKaxsdHaHZGj9GMUMYjkQr5FD0LYU8IyQnLLtCFzDmhIp-hh7ufgJdlCaYN2JX4GzStt6artMcbbWyzw67Bayjbf9AKXA2t7y_xddeY1rrmEt_0zmhfWF3h22O_gwYvXBO6-jBh3RTjImssNKYfdw249fqvGttp2ljXBfzB7cJz9KTUVYAXp3-Ovl4v7xYfo_Xt6tPiah0ZRiSPaMKZKRhLQWtDCplLkuVMJmmSS8N1wgsppGBbngCYNNtmjDG6NUJkMARWyHSOXk--B-9-dxBaVdtgoKp0A8MtShBCZTIYztHbadB4F4KHUh28rbXvFSVqrEXt1Zi9GrNXYy3qVIs6DuKXpy3dtobiLD31MPB3E7-3FfT_4aw2V4slZZQPFtFkYUMLx7OF9r9UzlOeqe-fVypPfnx5v1nfqE36B-1Drhw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80019292</pqid></control><display><type>article</type><title>The Effects of Ventricular Pacing on Left Ventricular Geometry, Function, Myocardial Oxygen Consumption, and Efficiency of Contraction in Conscious Dogs</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>OWEN, CLARENCE H. ; ESPOSITO, DAVID J. ; DAVIS, JAMES W. ; GLOWER, DONALD D.</creator><creatorcontrib>OWEN, CLARENCE H. ; ESPOSITO, DAVID J. ; DAVIS, JAMES W. ; GLOWER, DONALD D.</creatorcontrib><description>The effects of ventricular pacing on left ventricular (LV) dynamic geometry, function, and myocardial oxygen consumption (MVO2) were measured in 12 conscious dogs using sonomicrometry, micromanometry, ultrasonic flow probes, and oximetry catheters during right atrial (A‐) and right ventricular (V‐) pacing at 150 beats/mm. Systolic function was quantified using slopes (Mw) and volume‐intercepts (Vw) of linear relationships between end‐di‐astolic volume (EDV) and stroke work (SW) for data obtained during vena caval occlusion. V‐pacing shifted SW‐EDV relationships downward (Mw decreased from 97 ± 21 to 81 ± 21 Kerg/mL) and to the right (Vw increased from 14 ± 11 to 20 ± 12 mL) in comparison with A‐pacing (P &lt; 0.05). These functional changes correlated with altered contractile geometry manifest as early shortening in the septal free wall relative to anterior‐posterior dimension (increased minor axis mid‐wall eccentricity at end‐diastole and begin‐ejection). Steady‐state LV power output decreased from 802 ± 213 mW during A‐pacing to 514 ± 170 mW during V‐pacing (P &lt; 0.05), while MVO2 remained relatively unchanged during V‐pacing (10 ± 3 mL O2/min vs 11 ± 3 mL O2/min during A‐pacing, P = NS). As a result, overall LV efficiency decreased from 0.24 ± 0.08 during A‐pacing to 0.16 ± 0.06 during V‐pacing (P &lt; 0.05). These data illustrate the impact of V‐pacing on dynamic LV geometry and function, including impaired LV work output at all physiological levels of preload. Most importantly, the relationship between LV work output and MVO2 is depressed during V‐pacing, emphasizing the interaction between LV mechanics and pump efficiency in intact subjects. As a result, measures taken to restore normal contractile geometry might improve LV efficiency and performance when V‐pacing is necessary.</description><identifier>ISSN: 0147-8389</identifier><identifier>EISSN: 1540-8159</identifier><identifier>DOI: 10.1111/j.1540-8159.1998.tb00213.x</identifier><identifier>PMID: 9670186</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>Animals ; artificial pacing ; Cardiac Pacing, Artificial ; Consciousness ; Dogs ; Myocardial Contraction - physiology ; myocardial oxygen consumption ; Myocardium - metabolism ; Oxygen Consumption - physiology ; Pacemaker, Artificial ; Ventricular Function, Left - physiology ; ventricular performance</subject><ispartof>Pacing and clinical electrophysiology, 1998-07, Vol.21 (7), p.1417-1429</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4097-1274cd443eaac0d9690564923269c7a27d98984b72eec35b54441bc885e213d93</citedby><cites>FETCH-LOGICAL-c4097-1274cd443eaac0d9690564923269c7a27d98984b72eec35b54441bc885e213d93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1540-8159.1998.tb00213.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1540-8159.1998.tb00213.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9670186$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>OWEN, CLARENCE H.</creatorcontrib><creatorcontrib>ESPOSITO, DAVID J.</creatorcontrib><creatorcontrib>DAVIS, JAMES W.</creatorcontrib><creatorcontrib>GLOWER, DONALD D.</creatorcontrib><title>The Effects of Ventricular Pacing on Left Ventricular Geometry, Function, Myocardial Oxygen Consumption, and Efficiency of Contraction in Conscious Dogs</title><title>Pacing and clinical electrophysiology</title><addtitle>Pacing Clin Electrophysiol</addtitle><description>The effects of ventricular pacing on left ventricular (LV) dynamic geometry, function, and myocardial oxygen consumption (MVO2) were measured in 12 conscious dogs using sonomicrometry, micromanometry, ultrasonic flow probes, and oximetry catheters during right atrial (A‐) and right ventricular (V‐) pacing at 150 beats/mm. Systolic function was quantified using slopes (Mw) and volume‐intercepts (Vw) of linear relationships between end‐di‐astolic volume (EDV) and stroke work (SW) for data obtained during vena caval occlusion. V‐pacing shifted SW‐EDV relationships downward (Mw decreased from 97 ± 21 to 81 ± 21 Kerg/mL) and to the right (Vw increased from 14 ± 11 to 20 ± 12 mL) in comparison with A‐pacing (P &lt; 0.05). These functional changes correlated with altered contractile geometry manifest as early shortening in the septal free wall relative to anterior‐posterior dimension (increased minor axis mid‐wall eccentricity at end‐diastole and begin‐ejection). Steady‐state LV power output decreased from 802 ± 213 mW during A‐pacing to 514 ± 170 mW during V‐pacing (P &lt; 0.05), while MVO2 remained relatively unchanged during V‐pacing (10 ± 3 mL O2/min vs 11 ± 3 mL O2/min during A‐pacing, P = NS). As a result, overall LV efficiency decreased from 0.24 ± 0.08 during A‐pacing to 0.16 ± 0.06 during V‐pacing (P &lt; 0.05). These data illustrate the impact of V‐pacing on dynamic LV geometry and function, including impaired LV work output at all physiological levels of preload. Most importantly, the relationship between LV work output and MVO2 is depressed during V‐pacing, emphasizing the interaction between LV mechanics and pump efficiency in intact subjects. As a result, measures taken to restore normal contractile geometry might improve LV efficiency and performance when V‐pacing is necessary.</description><subject>Animals</subject><subject>artificial pacing</subject><subject>Cardiac Pacing, Artificial</subject><subject>Consciousness</subject><subject>Dogs</subject><subject>Myocardial Contraction - physiology</subject><subject>myocardial oxygen consumption</subject><subject>Myocardium - metabolism</subject><subject>Oxygen Consumption - physiology</subject><subject>Pacemaker, Artificial</subject><subject>Ventricular Function, Left - physiology</subject><subject>ventricular performance</subject><issn>0147-8389</issn><issn>1540-8159</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqVkcGO0zAURS0EGkrhE5AsFqwmwU6c2GbFUDoFqcMUaQCJjeU6L8UliYudaJo_mc8lIVUllnjjxXn3vqd7EXpFSUyH92Yf04yRSNBMxlRKEbdbQhKaxsdHaHZGj9GMUMYjkQr5FD0LYU8IyQnLLtCFzDmhIp-hh7ufgJdlCaYN2JX4GzStt6artMcbbWyzw67Bayjbf9AKXA2t7y_xddeY1rrmEt_0zmhfWF3h22O_gwYvXBO6-jBh3RTjImssNKYfdw249fqvGttp2ljXBfzB7cJz9KTUVYAXp3-Ovl4v7xYfo_Xt6tPiah0ZRiSPaMKZKRhLQWtDCplLkuVMJmmSS8N1wgsppGBbngCYNNtmjDG6NUJkMARWyHSOXk--B-9-dxBaVdtgoKp0A8MtShBCZTIYztHbadB4F4KHUh28rbXvFSVqrEXt1Zi9GrNXYy3qVIs6DuKXpy3dtobiLD31MPB3E7-3FfT_4aw2V4slZZQPFtFkYUMLx7OF9r9UzlOeqe-fVypPfnx5v1nfqE36B-1Drhw</recordid><startdate>199807</startdate><enddate>199807</enddate><creator>OWEN, CLARENCE H.</creator><creator>ESPOSITO, DAVID J.</creator><creator>DAVIS, JAMES W.</creator><creator>GLOWER, DONALD D.</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199807</creationdate><title>The Effects of Ventricular Pacing on Left Ventricular Geometry, Function, Myocardial Oxygen Consumption, and Efficiency of Contraction in Conscious Dogs</title><author>OWEN, CLARENCE H. ; ESPOSITO, DAVID J. ; DAVIS, JAMES W. ; GLOWER, DONALD D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4097-1274cd443eaac0d9690564923269c7a27d98984b72eec35b54441bc885e213d93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Animals</topic><topic>artificial pacing</topic><topic>Cardiac Pacing, Artificial</topic><topic>Consciousness</topic><topic>Dogs</topic><topic>Myocardial Contraction - physiology</topic><topic>myocardial oxygen consumption</topic><topic>Myocardium - metabolism</topic><topic>Oxygen Consumption - physiology</topic><topic>Pacemaker, Artificial</topic><topic>Ventricular Function, Left - physiology</topic><topic>ventricular performance</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>OWEN, CLARENCE H.</creatorcontrib><creatorcontrib>ESPOSITO, DAVID J.</creatorcontrib><creatorcontrib>DAVIS, JAMES W.</creatorcontrib><creatorcontrib>GLOWER, DONALD D.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Pacing and clinical electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>OWEN, CLARENCE H.</au><au>ESPOSITO, DAVID J.</au><au>DAVIS, JAMES W.</au><au>GLOWER, DONALD D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Effects of Ventricular Pacing on Left Ventricular Geometry, Function, Myocardial Oxygen Consumption, and Efficiency of Contraction in Conscious Dogs</atitle><jtitle>Pacing and clinical electrophysiology</jtitle><addtitle>Pacing Clin Electrophysiol</addtitle><date>1998-07</date><risdate>1998</risdate><volume>21</volume><issue>7</issue><spage>1417</spage><epage>1429</epage><pages>1417-1429</pages><issn>0147-8389</issn><eissn>1540-8159</eissn><abstract>The effects of ventricular pacing on left ventricular (LV) dynamic geometry, function, and myocardial oxygen consumption (MVO2) were measured in 12 conscious dogs using sonomicrometry, micromanometry, ultrasonic flow probes, and oximetry catheters during right atrial (A‐) and right ventricular (V‐) pacing at 150 beats/mm. Systolic function was quantified using slopes (Mw) and volume‐intercepts (Vw) of linear relationships between end‐di‐astolic volume (EDV) and stroke work (SW) for data obtained during vena caval occlusion. V‐pacing shifted SW‐EDV relationships downward (Mw decreased from 97 ± 21 to 81 ± 21 Kerg/mL) and to the right (Vw increased from 14 ± 11 to 20 ± 12 mL) in comparison with A‐pacing (P &lt; 0.05). These functional changes correlated with altered contractile geometry manifest as early shortening in the septal free wall relative to anterior‐posterior dimension (increased minor axis mid‐wall eccentricity at end‐diastole and begin‐ejection). Steady‐state LV power output decreased from 802 ± 213 mW during A‐pacing to 514 ± 170 mW during V‐pacing (P &lt; 0.05), while MVO2 remained relatively unchanged during V‐pacing (10 ± 3 mL O2/min vs 11 ± 3 mL O2/min during A‐pacing, P = NS). As a result, overall LV efficiency decreased from 0.24 ± 0.08 during A‐pacing to 0.16 ± 0.06 during V‐pacing (P &lt; 0.05). These data illustrate the impact of V‐pacing on dynamic LV geometry and function, including impaired LV work output at all physiological levels of preload. Most importantly, the relationship between LV work output and MVO2 is depressed during V‐pacing, emphasizing the interaction between LV mechanics and pump efficiency in intact subjects. As a result, measures taken to restore normal contractile geometry might improve LV efficiency and performance when V‐pacing is necessary.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>9670186</pmid><doi>10.1111/j.1540-8159.1998.tb00213.x</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0147-8389
ispartof Pacing and clinical electrophysiology, 1998-07, Vol.21 (7), p.1417-1429
issn 0147-8389
1540-8159
language eng
recordid cdi_proquest_miscellaneous_80019292
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects Animals
artificial pacing
Cardiac Pacing, Artificial
Consciousness
Dogs
Myocardial Contraction - physiology
myocardial oxygen consumption
Myocardium - metabolism
Oxygen Consumption - physiology
Pacemaker, Artificial
Ventricular Function, Left - physiology
ventricular performance
title The Effects of Ventricular Pacing on Left Ventricular Geometry, Function, Myocardial Oxygen Consumption, and Efficiency of Contraction in Conscious Dogs
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T05%3A59%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Effects%20of%20Ventricular%20Pacing%20on%20Left%20Ventricular%20Geometry,%20Function,%20Myocardial%20Oxygen%20Consumption,%20and%20Efficiency%20of%20Contraction%20in%20Conscious%20Dogs&rft.jtitle=Pacing%20and%20clinical%20electrophysiology&rft.au=OWEN,%20CLARENCE%20H.&rft.date=1998-07&rft.volume=21&rft.issue=7&rft.spage=1417&rft.epage=1429&rft.pages=1417-1429&rft.issn=0147-8389&rft.eissn=1540-8159&rft_id=info:doi/10.1111/j.1540-8159.1998.tb00213.x&rft_dat=%3Cproquest_cross%3E80019292%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80019292&rft_id=info:pmid/9670186&rfr_iscdi=true