Fluorophotometry in contact lens research : The next step
Fluorophotometry can be used to quantify changes in epithelial permeability (Pdc), corneal pH, and tear exchange (T95; time to deplete 95% of a fluorescent dye from beneath a contact lens) associated with contact lens wear. Using fluorometric procedures, we present previously reported data in order...
Gespeichert in:
Veröffentlicht in: | Optometry and vision science 1998-05, Vol.75 (5), p.316-322 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 322 |
---|---|
container_issue | 5 |
container_start_page | 316 |
container_title | Optometry and vision science |
container_volume | 75 |
creator | MCNAMARA, N. A POLSE, K. A BONANNO, J. A |
description | Fluorophotometry can be used to quantify changes in epithelial permeability (Pdc), corneal pH, and tear exchange (T95; time to deplete 95% of a fluorescent dye from beneath a contact lens) associated with contact lens wear. Using fluorometric procedures, we present previously reported data in order to review the effects of contact lens wear on Pdc and pH. We also introduce a new method for measuring tear exchange beneath a soft contact lens and present preliminary data.
Pdc was assessed on 32 subjects after 1 h of closed-eye soft contact lens wear. Stromal pH was assessed on 21 subjects wearing lenses with a range of different oxygen transmissibilities (Dk/L). T95 was assessed on 7 subjects who wore disposable lenses. Pdc estimates were derived by measuring the rate at which topically applied fluorescein crossed the epithelial barrier from the tears; corneal pH was quantified by alternately exciting a fluorescein-loaded cornea with two wavelengths of blue light and calculating the fluorescence intensity ratio (490/450 nm), which is pH-sensitive; and the T95 was estimated by applying 2 microliters of FITC-Dextran to the posterior surface of a soft contact lens and the monitoring the exponential decay of dye under the lens.
On average, 1 h of closed-eye contact lens wear caused a 41% increase in Pdc compared to the control eye. Corneal pH varied directly with a decrease in Dk/L. On average the T95 under contact lenses (mean = 29 min) was slow compared to normal rates with no lens (approximately 5 min).
Fluorophotometry can be used to quantify some interesting effects associated with contact lens wear, and the use of these techniques may provide new information about the impact of contact lens wear on corneal structure and function. |
doi_str_mv | 10.1097/00006324-199805000-00020 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79941260</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>339367</sourcerecordid><originalsourceid>FETCH-LOGICAL-c465t-3242081bc3e91a04bc44b14aa617f9c48c9fb81abce9c852a303439fc7e3180f3</originalsourceid><addsrcrecordid>eNqFkE1LxDAQhoMoq67-BCEH8VbNdxNvsrgqLHhZzyWNU7bSNjVJwf33RnfdqwPDzDDvfPAghCm5pcSUdySb4kwU1BhNZK6K7IwcoTMquS4M4_I450SQQgqtT9F5jB-E0JJLNUMzo5hQRp4hs-wmH_y48cn3kMIWtwN2fkjWJdzBEHGACDa4Db7H6w3gAb4SjgnGC3TS2C7C5T7O0dvycb14LlavTy-Lh1XhhJKpyE8yomntOBhqiaidEDUV1ipaNsYJ7UxTa2prB8ZpySwnXHDTuBI41aThc3Sz2zsG_zlBTFXfRgddZwfwU6xKYwRlivwrZJQLwZjIQr0TuuBjDNBUY2h7G7YVJdUP3uoPb3XAW_3izaNX-xtT3cP7YXDPM_ev930bne2aYAfXxoOMMam50vwbi3KArQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21344224</pqid></control><display><type>article</type><title>Fluorophotometry in contact lens research : The next step</title><source>MEDLINE</source><source>Journals@Ovid LWW Legacy Archive</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Journals@Ovid Complete</source><creator>MCNAMARA, N. A ; POLSE, K. A ; BONANNO, J. A</creator><creatorcontrib>MCNAMARA, N. A ; POLSE, K. A ; BONANNO, J. A</creatorcontrib><description>Fluorophotometry can be used to quantify changes in epithelial permeability (Pdc), corneal pH, and tear exchange (T95; time to deplete 95% of a fluorescent dye from beneath a contact lens) associated with contact lens wear. Using fluorometric procedures, we present previously reported data in order to review the effects of contact lens wear on Pdc and pH. We also introduce a new method for measuring tear exchange beneath a soft contact lens and present preliminary data.
Pdc was assessed on 32 subjects after 1 h of closed-eye soft contact lens wear. Stromal pH was assessed on 21 subjects wearing lenses with a range of different oxygen transmissibilities (Dk/L). T95 was assessed on 7 subjects who wore disposable lenses. Pdc estimates were derived by measuring the rate at which topically applied fluorescein crossed the epithelial barrier from the tears; corneal pH was quantified by alternately exciting a fluorescein-loaded cornea with two wavelengths of blue light and calculating the fluorescence intensity ratio (490/450 nm), which is pH-sensitive; and the T95 was estimated by applying 2 microliters of FITC-Dextran to the posterior surface of a soft contact lens and the monitoring the exponential decay of dye under the lens.
On average, 1 h of closed-eye contact lens wear caused a 41% increase in Pdc compared to the control eye. Corneal pH varied directly with a decrease in Dk/L. On average the T95 under contact lenses (mean = 29 min) was slow compared to normal rates with no lens (approximately 5 min).
Fluorophotometry can be used to quantify some interesting effects associated with contact lens wear, and the use of these techniques may provide new information about the impact of contact lens wear on corneal structure and function.</description><identifier>ISSN: 1040-5488</identifier><identifier>EISSN: 1538-9235</identifier><identifier>DOI: 10.1097/00006324-199805000-00020</identifier><identifier>PMID: 9624695</identifier><identifier>CODEN: OVSCET</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott Williams & Wilkins</publisher><subject>Biological and medical sciences ; Biological materials ; Cell Membrane Permeability ; Contact Lenses, Hydrophilic ; Dextrans - pharmacokinetics ; Diseases of the eye ; Disposable Equipment ; Epithelium, Corneal - metabolism ; Fluorescein-5-isothiocyanate - analogs & derivatives ; Fluorescein-5-isothiocyanate - pharmacokinetics ; Fluorescent Dyes - pharmacokinetics ; Fluorophotometry ; Humans ; Hydrogen-Ion Concentration ; Mechanical permeability ; Medical sciences ; Photometry ; Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects) ; Tears - metabolism</subject><ispartof>Optometry and vision science, 1998-05, Vol.75 (5), p.316-322</ispartof><rights>1998 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c465t-3242081bc3e91a04bc44b14aa617f9c48c9fb81abce9c852a303439fc7e3180f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=2258368$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9624695$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>MCNAMARA, N. A</creatorcontrib><creatorcontrib>POLSE, K. A</creatorcontrib><creatorcontrib>BONANNO, J. A</creatorcontrib><title>Fluorophotometry in contact lens research : The next step</title><title>Optometry and vision science</title><addtitle>Optom Vis Sci</addtitle><description>Fluorophotometry can be used to quantify changes in epithelial permeability (Pdc), corneal pH, and tear exchange (T95; time to deplete 95% of a fluorescent dye from beneath a contact lens) associated with contact lens wear. Using fluorometric procedures, we present previously reported data in order to review the effects of contact lens wear on Pdc and pH. We also introduce a new method for measuring tear exchange beneath a soft contact lens and present preliminary data.
Pdc was assessed on 32 subjects after 1 h of closed-eye soft contact lens wear. Stromal pH was assessed on 21 subjects wearing lenses with a range of different oxygen transmissibilities (Dk/L). T95 was assessed on 7 subjects who wore disposable lenses. Pdc estimates were derived by measuring the rate at which topically applied fluorescein crossed the epithelial barrier from the tears; corneal pH was quantified by alternately exciting a fluorescein-loaded cornea with two wavelengths of blue light and calculating the fluorescence intensity ratio (490/450 nm), which is pH-sensitive; and the T95 was estimated by applying 2 microliters of FITC-Dextran to the posterior surface of a soft contact lens and the monitoring the exponential decay of dye under the lens.
On average, 1 h of closed-eye contact lens wear caused a 41% increase in Pdc compared to the control eye. Corneal pH varied directly with a decrease in Dk/L. On average the T95 under contact lenses (mean = 29 min) was slow compared to normal rates with no lens (approximately 5 min).
Fluorophotometry can be used to quantify some interesting effects associated with contact lens wear, and the use of these techniques may provide new information about the impact of contact lens wear on corneal structure and function.</description><subject>Biological and medical sciences</subject><subject>Biological materials</subject><subject>Cell Membrane Permeability</subject><subject>Contact Lenses, Hydrophilic</subject><subject>Dextrans - pharmacokinetics</subject><subject>Diseases of the eye</subject><subject>Disposable Equipment</subject><subject>Epithelium, Corneal - metabolism</subject><subject>Fluorescein-5-isothiocyanate - analogs & derivatives</subject><subject>Fluorescein-5-isothiocyanate - pharmacokinetics</subject><subject>Fluorescent Dyes - pharmacokinetics</subject><subject>Fluorophotometry</subject><subject>Humans</subject><subject>Hydrogen-Ion Concentration</subject><subject>Mechanical permeability</subject><subject>Medical sciences</subject><subject>Photometry</subject><subject>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</subject><subject>Tears - metabolism</subject><issn>1040-5488</issn><issn>1538-9235</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1LxDAQhoMoq67-BCEH8VbNdxNvsrgqLHhZzyWNU7bSNjVJwf33RnfdqwPDzDDvfPAghCm5pcSUdySb4kwU1BhNZK6K7IwcoTMquS4M4_I450SQQgqtT9F5jB-E0JJLNUMzo5hQRp4hs-wmH_y48cn3kMIWtwN2fkjWJdzBEHGACDa4Db7H6w3gAb4SjgnGC3TS2C7C5T7O0dvycb14LlavTy-Lh1XhhJKpyE8yomntOBhqiaidEDUV1ipaNsYJ7UxTa2prB8ZpySwnXHDTuBI41aThc3Sz2zsG_zlBTFXfRgddZwfwU6xKYwRlivwrZJQLwZjIQr0TuuBjDNBUY2h7G7YVJdUP3uoPb3XAW_3izaNX-xtT3cP7YXDPM_ev930bne2aYAfXxoOMMam50vwbi3KArQ</recordid><startdate>19980501</startdate><enddate>19980501</enddate><creator>MCNAMARA, N. A</creator><creator>POLSE, K. A</creator><creator>BONANNO, J. A</creator><general>Lippincott Williams & Wilkins</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19980501</creationdate><title>Fluorophotometry in contact lens research : The next step</title><author>MCNAMARA, N. A ; POLSE, K. A ; BONANNO, J. A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c465t-3242081bc3e91a04bc44b14aa617f9c48c9fb81abce9c852a303439fc7e3180f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Biological and medical sciences</topic><topic>Biological materials</topic><topic>Cell Membrane Permeability</topic><topic>Contact Lenses, Hydrophilic</topic><topic>Dextrans - pharmacokinetics</topic><topic>Diseases of the eye</topic><topic>Disposable Equipment</topic><topic>Epithelium, Corneal - metabolism</topic><topic>Fluorescein-5-isothiocyanate - analogs & derivatives</topic><topic>Fluorescein-5-isothiocyanate - pharmacokinetics</topic><topic>Fluorescent Dyes - pharmacokinetics</topic><topic>Fluorophotometry</topic><topic>Humans</topic><topic>Hydrogen-Ion Concentration</topic><topic>Mechanical permeability</topic><topic>Medical sciences</topic><topic>Photometry</topic><topic>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</topic><topic>Tears - metabolism</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>MCNAMARA, N. A</creatorcontrib><creatorcontrib>POLSE, K. A</creatorcontrib><creatorcontrib>BONANNO, J. A</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optometry and vision science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MCNAMARA, N. A</au><au>POLSE, K. A</au><au>BONANNO, J. A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fluorophotometry in contact lens research : The next step</atitle><jtitle>Optometry and vision science</jtitle><addtitle>Optom Vis Sci</addtitle><date>1998-05-01</date><risdate>1998</risdate><volume>75</volume><issue>5</issue><spage>316</spage><epage>322</epage><pages>316-322</pages><issn>1040-5488</issn><eissn>1538-9235</eissn><coden>OVSCET</coden><abstract>Fluorophotometry can be used to quantify changes in epithelial permeability (Pdc), corneal pH, and tear exchange (T95; time to deplete 95% of a fluorescent dye from beneath a contact lens) associated with contact lens wear. Using fluorometric procedures, we present previously reported data in order to review the effects of contact lens wear on Pdc and pH. We also introduce a new method for measuring tear exchange beneath a soft contact lens and present preliminary data.
Pdc was assessed on 32 subjects after 1 h of closed-eye soft contact lens wear. Stromal pH was assessed on 21 subjects wearing lenses with a range of different oxygen transmissibilities (Dk/L). T95 was assessed on 7 subjects who wore disposable lenses. Pdc estimates were derived by measuring the rate at which topically applied fluorescein crossed the epithelial barrier from the tears; corneal pH was quantified by alternately exciting a fluorescein-loaded cornea with two wavelengths of blue light and calculating the fluorescence intensity ratio (490/450 nm), which is pH-sensitive; and the T95 was estimated by applying 2 microliters of FITC-Dextran to the posterior surface of a soft contact lens and the monitoring the exponential decay of dye under the lens.
On average, 1 h of closed-eye contact lens wear caused a 41% increase in Pdc compared to the control eye. Corneal pH varied directly with a decrease in Dk/L. On average the T95 under contact lenses (mean = 29 min) was slow compared to normal rates with no lens (approximately 5 min).
Fluorophotometry can be used to quantify some interesting effects associated with contact lens wear, and the use of these techniques may provide new information about the impact of contact lens wear on corneal structure and function.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott Williams & Wilkins</pub><pmid>9624695</pmid><doi>10.1097/00006324-199805000-00020</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1040-5488 |
ispartof | Optometry and vision science, 1998-05, Vol.75 (5), p.316-322 |
issn | 1040-5488 1538-9235 |
language | eng |
recordid | cdi_proquest_miscellaneous_79941260 |
source | MEDLINE; Journals@Ovid LWW Legacy Archive; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Journals@Ovid Complete |
subjects | Biological and medical sciences Biological materials Cell Membrane Permeability Contact Lenses, Hydrophilic Dextrans - pharmacokinetics Diseases of the eye Disposable Equipment Epithelium, Corneal - metabolism Fluorescein-5-isothiocyanate - analogs & derivatives Fluorescein-5-isothiocyanate - pharmacokinetics Fluorescent Dyes - pharmacokinetics Fluorophotometry Humans Hydrogen-Ion Concentration Mechanical permeability Medical sciences Photometry Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects) Tears - metabolism |
title | Fluorophotometry in contact lens research : The next step |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T19%3A22%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fluorophotometry%20in%20contact%20lens%20research%20:%20The%20next%20step&rft.jtitle=Optometry%20and%20vision%20science&rft.au=MCNAMARA,%20N.%20A&rft.date=1998-05-01&rft.volume=75&rft.issue=5&rft.spage=316&rft.epage=322&rft.pages=316-322&rft.issn=1040-5488&rft.eissn=1538-9235&rft.coden=OVSCET&rft_id=info:doi/10.1097/00006324-199805000-00020&rft_dat=%3Cproquest_cross%3E339367%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=21344224&rft_id=info:pmid/9624695&rfr_iscdi=true |