Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people
Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory v...
Gespeichert in:
Veröffentlicht in: | The American journal of clinical nutrition 1990-08, Vol.52 (2), p.397-400 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 400 |
---|---|
container_issue | 2 |
container_start_page | 397 |
container_title | The American journal of clinical nutrition |
container_volume | 52 |
creator | Cockram, DB Baumgartner, RN |
description | Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory volunteers with each caliper. Knee height was measured on the left leg from the heel to a point 5 cm proximal to the patella. Intracaliper reliability was similar. Mean absolute differences between repeated measurements ranged from 0.17 to 0.25 cm, technical errors of the estimate ranged from 0.16 to 0.26 cm, and coefficients of reliability exceeded 0.99 for each model. Equations based on knee height predicted subjects’ stature to ± 2.3 cm, an amount unlikely to substantially impair height-based nutrition indices. This comparatively inexpensive caliper was as accurate and reliable as more expensive commercially available models and may be recommended as an alternative to the other calipers. |
doi_str_mv | 10.1093/ajcn/52.2.397 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79898656</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S000291652316895X</els_id><sourcerecordid>79898656</sourcerecordid><originalsourceid>FETCH-LOGICAL-c460t-67d01e991cbebeeb58a7157a825c7f25a20f35a70dd618aec95c6443a0788a7d3</originalsourceid><addsrcrecordid>eNp1kTFr3DAUgEVpSS9pxyyFgqZuvkiyZVljCWlSCHRoM4tn-flOiSy5kh24f18dd2Tr9Ibv44n3iZBrzrac6foGnm24kWIrtrVW78iG67qrasHUe7JhjIlK81Z-JJc5PzPGRdO1F-RC8FrIRm_I_u4V_AqLi4HGkYK1awJ7oBAGmtA76J13y-HILHg3Y8p0jIlOCHlNLuyKZdepx7DQl4BI9-h2-4W6QNEPmPyBzhhnj5_IhxF8xs_neUWeftz9uX2oHn_d_7z9_ljZpmVL1aqBcdSa2x57xF52oLhU0Alp1SgkCDbWEhQbhpZ3gFZL2zZNDUx1RR3qK_LttHdO8e-KeTGTyxa9h4BxzUbpTnetbItYnUSbYs4JRzMnN0E6GM7Msaw5ljVSGGFK2eJ_PS9e-wmHN_ucsvAvJz5CNLBLLpun35qXL5CyQHWCWE5_dZhMtg6DxcGVfosZovvPs_8AbnyRfg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79898656</pqid></control><display><type>article</type><title>Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Cockram, DB ; Baumgartner, RN</creator><creatorcontrib>Cockram, DB ; Baumgartner, RN</creatorcontrib><description>Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory volunteers with each caliper. Knee height was measured on the left leg from the heel to a point 5 cm proximal to the patella. Intracaliper reliability was similar. Mean absolute differences between repeated measurements ranged from 0.17 to 0.25 cm, technical errors of the estimate ranged from 0.16 to 0.26 cm, and coefficients of reliability exceeded 0.99 for each model. Equations based on knee height predicted subjects’ stature to ± 2.3 cm, an amount unlikely to substantially impair height-based nutrition indices. This comparatively inexpensive caliper was as accurate and reliable as more expensive commercially available models and may be recommended as an alternative to the other calipers.</description><identifier>ISSN: 0002-9165</identifier><identifier>EISSN: 1938-3207</identifier><identifier>DOI: 10.1093/ajcn/52.2.397</identifier><identifier>PMID: 2132549</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Age Factors ; Aged ; Aged, 80 and over ; ALTURA ; Analysis of Variance ; Anthropometry - methods ; ARTICULACIONES ; ARTICULATION ; Body Height ; Calibration ; ERGONOMIA ; ERGONOMIE ; EVALUACION ; EVALUATION ; Female ; FEMME ; HAUTEUR ; HOMBRES ; HOMME ; Humans ; Leg - anatomy & histology ; Male ; MEDICION ; MESURE ; MUJERES ; NUTRICION HUMANA ; NUTRITION HUMAINE ; Nutritional Status ; PERSONNE AGEE ; Reproducibility of Results ; Sex Characteristics ; TERCERA EDAD</subject><ispartof>The American journal of clinical nutrition, 1990-08, Vol.52 (2), p.397-400</ispartof><rights>1990 American Society for Nutrition.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c460t-67d01e991cbebeeb58a7157a825c7f25a20f35a70dd618aec95c6443a0788a7d3</citedby><cites>FETCH-LOGICAL-c460t-67d01e991cbebeeb58a7157a825c7f25a20f35a70dd618aec95c6443a0788a7d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2132549$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cockram, DB</creatorcontrib><creatorcontrib>Baumgartner, RN</creatorcontrib><title>Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people</title><title>The American journal of clinical nutrition</title><addtitle>Am J Clin Nutr</addtitle><description>Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory volunteers with each caliper. Knee height was measured on the left leg from the heel to a point 5 cm proximal to the patella. Intracaliper reliability was similar. Mean absolute differences between repeated measurements ranged from 0.17 to 0.25 cm, technical errors of the estimate ranged from 0.16 to 0.26 cm, and coefficients of reliability exceeded 0.99 for each model. Equations based on knee height predicted subjects’ stature to ± 2.3 cm, an amount unlikely to substantially impair height-based nutrition indices. This comparatively inexpensive caliper was as accurate and reliable as more expensive commercially available models and may be recommended as an alternative to the other calipers.</description><subject>Age Factors</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>ALTURA</subject><subject>Analysis of Variance</subject><subject>Anthropometry - methods</subject><subject>ARTICULACIONES</subject><subject>ARTICULATION</subject><subject>Body Height</subject><subject>Calibration</subject><subject>ERGONOMIA</subject><subject>ERGONOMIE</subject><subject>EVALUACION</subject><subject>EVALUATION</subject><subject>Female</subject><subject>FEMME</subject><subject>HAUTEUR</subject><subject>HOMBRES</subject><subject>HOMME</subject><subject>Humans</subject><subject>Leg - anatomy & histology</subject><subject>Male</subject><subject>MEDICION</subject><subject>MESURE</subject><subject>MUJERES</subject><subject>NUTRICION HUMANA</subject><subject>NUTRITION HUMAINE</subject><subject>Nutritional Status</subject><subject>PERSONNE AGEE</subject><subject>Reproducibility of Results</subject><subject>Sex Characteristics</subject><subject>TERCERA EDAD</subject><issn>0002-9165</issn><issn>1938-3207</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kTFr3DAUgEVpSS9pxyyFgqZuvkiyZVljCWlSCHRoM4tn-flOiSy5kh24f18dd2Tr9Ibv44n3iZBrzrac6foGnm24kWIrtrVW78iG67qrasHUe7JhjIlK81Z-JJc5PzPGRdO1F-RC8FrIRm_I_u4V_AqLi4HGkYK1awJ7oBAGmtA76J13y-HILHg3Y8p0jIlOCHlNLuyKZdepx7DQl4BI9-h2-4W6QNEPmPyBzhhnj5_IhxF8xs_neUWeftz9uX2oHn_d_7z9_ljZpmVL1aqBcdSa2x57xF52oLhU0Alp1SgkCDbWEhQbhpZ3gFZL2zZNDUx1RR3qK_LttHdO8e-KeTGTyxa9h4BxzUbpTnetbItYnUSbYs4JRzMnN0E6GM7Msaw5ljVSGGFK2eJ_PS9e-wmHN_ucsvAvJz5CNLBLLpun35qXL5CyQHWCWE5_dZhMtg6DxcGVfosZovvPs_8AbnyRfg</recordid><startdate>19900801</startdate><enddate>19900801</enddate><creator>Cockram, DB</creator><creator>Baumgartner, RN</creator><general>Elsevier Inc</general><scope>FBQ</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19900801</creationdate><title>Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people</title><author>Cockram, DB ; Baumgartner, RN</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c460t-67d01e991cbebeeb58a7157a825c7f25a20f35a70dd618aec95c6443a0788a7d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Age Factors</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>ALTURA</topic><topic>Analysis of Variance</topic><topic>Anthropometry - methods</topic><topic>ARTICULACIONES</topic><topic>ARTICULATION</topic><topic>Body Height</topic><topic>Calibration</topic><topic>ERGONOMIA</topic><topic>ERGONOMIE</topic><topic>EVALUACION</topic><topic>EVALUATION</topic><topic>Female</topic><topic>FEMME</topic><topic>HAUTEUR</topic><topic>HOMBRES</topic><topic>HOMME</topic><topic>Humans</topic><topic>Leg - anatomy & histology</topic><topic>Male</topic><topic>MEDICION</topic><topic>MESURE</topic><topic>MUJERES</topic><topic>NUTRICION HUMANA</topic><topic>NUTRITION HUMAINE</topic><topic>Nutritional Status</topic><topic>PERSONNE AGEE</topic><topic>Reproducibility of Results</topic><topic>Sex Characteristics</topic><topic>TERCERA EDAD</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cockram, DB</creatorcontrib><creatorcontrib>Baumgartner, RN</creatorcontrib><collection>AGRIS</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The American journal of clinical nutrition</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cockram, DB</au><au>Baumgartner, RN</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people</atitle><jtitle>The American journal of clinical nutrition</jtitle><addtitle>Am J Clin Nutr</addtitle><date>1990-08-01</date><risdate>1990</risdate><volume>52</volume><issue>2</issue><spage>397</spage><epage>400</epage><pages>397-400</pages><issn>0002-9165</issn><eissn>1938-3207</eissn><abstract>Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory volunteers with each caliper. Knee height was measured on the left leg from the heel to a point 5 cm proximal to the patella. Intracaliper reliability was similar. Mean absolute differences between repeated measurements ranged from 0.17 to 0.25 cm, technical errors of the estimate ranged from 0.16 to 0.26 cm, and coefficients of reliability exceeded 0.99 for each model. Equations based on knee height predicted subjects’ stature to ± 2.3 cm, an amount unlikely to substantially impair height-based nutrition indices. This comparatively inexpensive caliper was as accurate and reliable as more expensive commercially available models and may be recommended as an alternative to the other calipers.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>2132549</pmid><doi>10.1093/ajcn/52.2.397</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0002-9165 |
ispartof | The American journal of clinical nutrition, 1990-08, Vol.52 (2), p.397-400 |
issn | 0002-9165 1938-3207 |
language | eng |
recordid | cdi_proquest_miscellaneous_79898656 |
source | MEDLINE; Alma/SFX Local Collection |
subjects | Age Factors Aged Aged, 80 and over ALTURA Analysis of Variance Anthropometry - methods ARTICULACIONES ARTICULATION Body Height Calibration ERGONOMIA ERGONOMIE EVALUACION EVALUATION Female FEMME HAUTEUR HOMBRES HOMME Humans Leg - anatomy & histology Male MEDICION MESURE MUJERES NUTRICION HUMANA NUTRITION HUMAINE Nutritional Status PERSONNE AGEE Reproducibility of Results Sex Characteristics TERCERA EDAD |
title | Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T15%3A12%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20accuracy%20and%20reliability%20of%20calipers%20for%20measuring%20recumbent%20knee%20height%20in%20elderly%20people&rft.jtitle=The%20American%20journal%20of%20clinical%20nutrition&rft.au=Cockram,%20DB&rft.date=1990-08-01&rft.volume=52&rft.issue=2&rft.spage=397&rft.epage=400&rft.pages=397-400&rft.issn=0002-9165&rft.eissn=1938-3207&rft_id=info:doi/10.1093/ajcn/52.2.397&rft_dat=%3Cproquest_cross%3E79898656%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79898656&rft_id=info:pmid/2132549&rft_els_id=S000291652316895X&rfr_iscdi=true |