Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people

Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory v...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of clinical nutrition 1990-08, Vol.52 (2), p.397-400
Hauptverfasser: Cockram, DB, Baumgartner, RN
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 400
container_issue 2
container_start_page 397
container_title The American journal of clinical nutrition
container_volume 52
creator Cockram, DB
Baumgartner, RN
description Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory volunteers with each caliper. Knee height was measured on the left leg from the heel to a point 5 cm proximal to the patella. Intracaliper reliability was similar. Mean absolute differences between repeated measurements ranged from 0.17 to 0.25 cm, technical errors of the estimate ranged from 0.16 to 0.26 cm, and coefficients of reliability exceeded 0.99 for each model. Equations based on knee height predicted subjects’ stature to ± 2.3 cm, an amount unlikely to substantially impair height-based nutrition indices. This comparatively inexpensive caliper was as accurate and reliable as more expensive commercially available models and may be recommended as an alternative to the other calipers.
doi_str_mv 10.1093/ajcn/52.2.397
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79898656</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S000291652316895X</els_id><sourcerecordid>79898656</sourcerecordid><originalsourceid>FETCH-LOGICAL-c460t-67d01e991cbebeeb58a7157a825c7f25a20f35a70dd618aec95c6443a0788a7d3</originalsourceid><addsrcrecordid>eNp1kTFr3DAUgEVpSS9pxyyFgqZuvkiyZVljCWlSCHRoM4tn-flOiSy5kh24f18dd2Tr9Ibv44n3iZBrzrac6foGnm24kWIrtrVW78iG67qrasHUe7JhjIlK81Z-JJc5PzPGRdO1F-RC8FrIRm_I_u4V_AqLi4HGkYK1awJ7oBAGmtA76J13y-HILHg3Y8p0jIlOCHlNLuyKZdepx7DQl4BI9-h2-4W6QNEPmPyBzhhnj5_IhxF8xs_neUWeftz9uX2oHn_d_7z9_ljZpmVL1aqBcdSa2x57xF52oLhU0Alp1SgkCDbWEhQbhpZ3gFZL2zZNDUx1RR3qK_LttHdO8e-KeTGTyxa9h4BxzUbpTnetbItYnUSbYs4JRzMnN0E6GM7Msaw5ljVSGGFK2eJ_PS9e-wmHN_ucsvAvJz5CNLBLLpun35qXL5CyQHWCWE5_dZhMtg6DxcGVfosZovvPs_8AbnyRfg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79898656</pqid></control><display><type>article</type><title>Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Cockram, DB ; Baumgartner, RN</creator><creatorcontrib>Cockram, DB ; Baumgartner, RN</creatorcontrib><description>Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory volunteers with each caliper. Knee height was measured on the left leg from the heel to a point 5 cm proximal to the patella. Intracaliper reliability was similar. Mean absolute differences between repeated measurements ranged from 0.17 to 0.25 cm, technical errors of the estimate ranged from 0.16 to 0.26 cm, and coefficients of reliability exceeded 0.99 for each model. Equations based on knee height predicted subjects’ stature to ± 2.3 cm, an amount unlikely to substantially impair height-based nutrition indices. This comparatively inexpensive caliper was as accurate and reliable as more expensive commercially available models and may be recommended as an alternative to the other calipers.</description><identifier>ISSN: 0002-9165</identifier><identifier>EISSN: 1938-3207</identifier><identifier>DOI: 10.1093/ajcn/52.2.397</identifier><identifier>PMID: 2132549</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Age Factors ; Aged ; Aged, 80 and over ; ALTURA ; Analysis of Variance ; Anthropometry - methods ; ARTICULACIONES ; ARTICULATION ; Body Height ; Calibration ; ERGONOMIA ; ERGONOMIE ; EVALUACION ; EVALUATION ; Female ; FEMME ; HAUTEUR ; HOMBRES ; HOMME ; Humans ; Leg - anatomy &amp; histology ; Male ; MEDICION ; MESURE ; MUJERES ; NUTRICION HUMANA ; NUTRITION HUMAINE ; Nutritional Status ; PERSONNE AGEE ; Reproducibility of Results ; Sex Characteristics ; TERCERA EDAD</subject><ispartof>The American journal of clinical nutrition, 1990-08, Vol.52 (2), p.397-400</ispartof><rights>1990 American Society for Nutrition.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c460t-67d01e991cbebeeb58a7157a825c7f25a20f35a70dd618aec95c6443a0788a7d3</citedby><cites>FETCH-LOGICAL-c460t-67d01e991cbebeeb58a7157a825c7f25a20f35a70dd618aec95c6443a0788a7d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2132549$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cockram, DB</creatorcontrib><creatorcontrib>Baumgartner, RN</creatorcontrib><title>Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people</title><title>The American journal of clinical nutrition</title><addtitle>Am J Clin Nutr</addtitle><description>Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory volunteers with each caliper. Knee height was measured on the left leg from the heel to a point 5 cm proximal to the patella. Intracaliper reliability was similar. Mean absolute differences between repeated measurements ranged from 0.17 to 0.25 cm, technical errors of the estimate ranged from 0.16 to 0.26 cm, and coefficients of reliability exceeded 0.99 for each model. Equations based on knee height predicted subjects’ stature to ± 2.3 cm, an amount unlikely to substantially impair height-based nutrition indices. This comparatively inexpensive caliper was as accurate and reliable as more expensive commercially available models and may be recommended as an alternative to the other calipers.</description><subject>Age Factors</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>ALTURA</subject><subject>Analysis of Variance</subject><subject>Anthropometry - methods</subject><subject>ARTICULACIONES</subject><subject>ARTICULATION</subject><subject>Body Height</subject><subject>Calibration</subject><subject>ERGONOMIA</subject><subject>ERGONOMIE</subject><subject>EVALUACION</subject><subject>EVALUATION</subject><subject>Female</subject><subject>FEMME</subject><subject>HAUTEUR</subject><subject>HOMBRES</subject><subject>HOMME</subject><subject>Humans</subject><subject>Leg - anatomy &amp; histology</subject><subject>Male</subject><subject>MEDICION</subject><subject>MESURE</subject><subject>MUJERES</subject><subject>NUTRICION HUMANA</subject><subject>NUTRITION HUMAINE</subject><subject>Nutritional Status</subject><subject>PERSONNE AGEE</subject><subject>Reproducibility of Results</subject><subject>Sex Characteristics</subject><subject>TERCERA EDAD</subject><issn>0002-9165</issn><issn>1938-3207</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kTFr3DAUgEVpSS9pxyyFgqZuvkiyZVljCWlSCHRoM4tn-flOiSy5kh24f18dd2Tr9Ibv44n3iZBrzrac6foGnm24kWIrtrVW78iG67qrasHUe7JhjIlK81Z-JJc5PzPGRdO1F-RC8FrIRm_I_u4V_AqLi4HGkYK1awJ7oBAGmtA76J13y-HILHg3Y8p0jIlOCHlNLuyKZdepx7DQl4BI9-h2-4W6QNEPmPyBzhhnj5_IhxF8xs_neUWeftz9uX2oHn_d_7z9_ljZpmVL1aqBcdSa2x57xF52oLhU0Alp1SgkCDbWEhQbhpZ3gFZL2zZNDUx1RR3qK_LttHdO8e-KeTGTyxa9h4BxzUbpTnetbItYnUSbYs4JRzMnN0E6GM7Msaw5ljVSGGFK2eJ_PS9e-wmHN_ucsvAvJz5CNLBLLpun35qXL5CyQHWCWE5_dZhMtg6DxcGVfosZovvPs_8AbnyRfg</recordid><startdate>19900801</startdate><enddate>19900801</enddate><creator>Cockram, DB</creator><creator>Baumgartner, RN</creator><general>Elsevier Inc</general><scope>FBQ</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19900801</creationdate><title>Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people</title><author>Cockram, DB ; Baumgartner, RN</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c460t-67d01e991cbebeeb58a7157a825c7f25a20f35a70dd618aec95c6443a0788a7d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Age Factors</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>ALTURA</topic><topic>Analysis of Variance</topic><topic>Anthropometry - methods</topic><topic>ARTICULACIONES</topic><topic>ARTICULATION</topic><topic>Body Height</topic><topic>Calibration</topic><topic>ERGONOMIA</topic><topic>ERGONOMIE</topic><topic>EVALUACION</topic><topic>EVALUATION</topic><topic>Female</topic><topic>FEMME</topic><topic>HAUTEUR</topic><topic>HOMBRES</topic><topic>HOMME</topic><topic>Humans</topic><topic>Leg - anatomy &amp; histology</topic><topic>Male</topic><topic>MEDICION</topic><topic>MESURE</topic><topic>MUJERES</topic><topic>NUTRICION HUMANA</topic><topic>NUTRITION HUMAINE</topic><topic>Nutritional Status</topic><topic>PERSONNE AGEE</topic><topic>Reproducibility of Results</topic><topic>Sex Characteristics</topic><topic>TERCERA EDAD</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cockram, DB</creatorcontrib><creatorcontrib>Baumgartner, RN</creatorcontrib><collection>AGRIS</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The American journal of clinical nutrition</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cockram, DB</au><au>Baumgartner, RN</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people</atitle><jtitle>The American journal of clinical nutrition</jtitle><addtitle>Am J Clin Nutr</addtitle><date>1990-08-01</date><risdate>1990</risdate><volume>52</volume><issue>2</issue><spage>397</spage><epage>400</epage><pages>397-400</pages><issn>0002-9165</issn><eissn>1938-3207</eissn><abstract>Height measurements in elderly individuals are frequently not feasible and stature must be estimated from knee height. This study compared the accuracy and reliability of a knee-height caliper developed by Ross Laboratories with Mediform and GPN models. Two observers measured 40 elderly ambulatory volunteers with each caliper. Knee height was measured on the left leg from the heel to a point 5 cm proximal to the patella. Intracaliper reliability was similar. Mean absolute differences between repeated measurements ranged from 0.17 to 0.25 cm, technical errors of the estimate ranged from 0.16 to 0.26 cm, and coefficients of reliability exceeded 0.99 for each model. Equations based on knee height predicted subjects’ stature to ± 2.3 cm, an amount unlikely to substantially impair height-based nutrition indices. This comparatively inexpensive caliper was as accurate and reliable as more expensive commercially available models and may be recommended as an alternative to the other calipers.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>2132549</pmid><doi>10.1093/ajcn/52.2.397</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0002-9165
ispartof The American journal of clinical nutrition, 1990-08, Vol.52 (2), p.397-400
issn 0002-9165
1938-3207
language eng
recordid cdi_proquest_miscellaneous_79898656
source MEDLINE; Alma/SFX Local Collection
subjects Age Factors
Aged
Aged, 80 and over
ALTURA
Analysis of Variance
Anthropometry - methods
ARTICULACIONES
ARTICULATION
Body Height
Calibration
ERGONOMIA
ERGONOMIE
EVALUACION
EVALUATION
Female
FEMME
HAUTEUR
HOMBRES
HOMME
Humans
Leg - anatomy & histology
Male
MEDICION
MESURE
MUJERES
NUTRICION HUMANA
NUTRITION HUMAINE
Nutritional Status
PERSONNE AGEE
Reproducibility of Results
Sex Characteristics
TERCERA EDAD
title Evaluation of accuracy and reliability of calipers for measuring recumbent knee height in elderly people
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T15%3A12%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20accuracy%20and%20reliability%20of%20calipers%20for%20measuring%20recumbent%20knee%20height%20in%20elderly%20people&rft.jtitle=The%20American%20journal%20of%20clinical%20nutrition&rft.au=Cockram,%20DB&rft.date=1990-08-01&rft.volume=52&rft.issue=2&rft.spage=397&rft.epage=400&rft.pages=397-400&rft.issn=0002-9165&rft.eissn=1938-3207&rft_id=info:doi/10.1093/ajcn/52.2.397&rft_dat=%3Cproquest_cross%3E79898656%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79898656&rft_id=info:pmid/2132549&rft_els_id=S000291652316895X&rfr_iscdi=true