Iopentol Compared with Iohexol in Carotid Angiography: A Double Blind Crossover Test of a New Non-Ionic Contrast Medium

A randomized double blind crossover test with iohexol and the new non-ionic contrast medium iopentol in 12 patients undergoing carotid angiography showed no difference in tolerability, EEG, ECG, neurologic status or image quality. Iopentol seems to be well suited for cerebral angiography.

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta radiologica (1987) 1990-03, Vol.31 (2), p.221-222
Hauptverfasser: Nakstad, P. H., Skalpe, I. O., Bakke, S. J., Aanonsen, N. O., Ganes, T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 222
container_issue 2
container_start_page 221
container_title Acta radiologica (1987)
container_volume 31
creator Nakstad, P. H.
Skalpe, I. O.
Bakke, S. J.
Aanonsen, N. O.
Ganes, T.
description A randomized double blind crossover test with iohexol and the new non-ionic contrast medium iopentol in 12 patients undergoing carotid angiography showed no difference in tolerability, EEG, ECG, neurologic status or image quality. Iopentol seems to be well suited for cerebral angiography.
doi_str_mv 10.1177/028418519003100222
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79887357</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_028418519003100222</sage_id><sourcerecordid>79887357</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1652-5ee133308f3b2392c5c46cd77ab7a57bb781f96f1256ba146a77e1dc6b115cff3</originalsourceid><addsrcrecordid>eNp9kEFLwzAUx4Moc06_gCD0IN7q8pImaY-jTB0MvOi5pGmydbRNTVp0396WlV0ETw_e-_3_D34I3QN-BhBiiUkcQcwgwZgCxoSQCzQHjnGII8Yu0XwEwpG4RjfeHzAGIhjM0IxQQSKezBHb2FY3na2C1NatdLoIvstuH2zsXv8M27IJUulsVxbBqtmVdudkuz_eoisjK6_vprlAny_rj_Qt3L6_btLVNlTAGQmZ1kApxbGhOaEJUUxFXBVCyFxIJvJcxGASboAwnkuIuBRCQ6F4DsCUMXSBnk69rbNfvfZdVpde6aqSjba9z0QSx4IyMYDkBCpnvXfaZK0ra-mOGeBsdJX9dTWEHqb2Pq91cY5Mcob743SXXsnKONmo0p-xiGGKxVizPGFe7nR2sL1rBif_Pf4Fm2Z8Vg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79887357</pqid></control><display><type>article</type><title>Iopentol Compared with Iohexol in Carotid Angiography: A Double Blind Crossover Test of a New Non-Ionic Contrast Medium</title><source>MEDLINE</source><source>Taylor &amp; Francis Journals Complete</source><creator>Nakstad, P. H. ; Skalpe, I. O. ; Bakke, S. J. ; Aanonsen, N. O. ; Ganes, T.</creator><creatorcontrib>Nakstad, P. H. ; Skalpe, I. O. ; Bakke, S. J. ; Aanonsen, N. O. ; Ganes, T.</creatorcontrib><description>A randomized double blind crossover test with iohexol and the new non-ionic contrast medium iopentol in 12 patients undergoing carotid angiography showed no difference in tolerability, EEG, ECG, neurologic status or image quality. Iopentol seems to be well suited for cerebral angiography.</description><identifier>ISSN: 0284-1851</identifier><identifier>EISSN: 1600-0455</identifier><identifier>DOI: 10.1177/028418519003100222</identifier><identifier>PMID: 2372469</identifier><identifier>CODEN: ACRAE3</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Adult ; Aged ; Biological and medical sciences ; Cerebral Angiography ; Contrast Media ; Double-Blind Method ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Iodobenzoates ; Iohexol ; Medical sciences ; Middle Aged ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Random Allocation ; Triiodobenzoic Acids</subject><ispartof>Acta radiologica (1987), 1990-03, Vol.31 (2), p.221-222</ispartof><rights>1990 The Foundation Acta Radiologica</rights><rights>1993 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1652-5ee133308f3b2392c5c46cd77ab7a57bb781f96f1256ba146a77e1dc6b115cff3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4503072$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2372469$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nakstad, P. H.</creatorcontrib><creatorcontrib>Skalpe, I. O.</creatorcontrib><creatorcontrib>Bakke, S. J.</creatorcontrib><creatorcontrib>Aanonsen, N. O.</creatorcontrib><creatorcontrib>Ganes, T.</creatorcontrib><title>Iopentol Compared with Iohexol in Carotid Angiography: A Double Blind Crossover Test of a New Non-Ionic Contrast Medium</title><title>Acta radiologica (1987)</title><addtitle>Acta Radiol</addtitle><description>A randomized double blind crossover test with iohexol and the new non-ionic contrast medium iopentol in 12 patients undergoing carotid angiography showed no difference in tolerability, EEG, ECG, neurologic status or image quality. Iopentol seems to be well suited for cerebral angiography.</description><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Cerebral Angiography</subject><subject>Contrast Media</subject><subject>Double-Blind Method</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Iodobenzoates</subject><subject>Iohexol</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Random Allocation</subject><subject>Triiodobenzoic Acids</subject><issn>0284-1851</issn><issn>1600-0455</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kEFLwzAUx4Moc06_gCD0IN7q8pImaY-jTB0MvOi5pGmydbRNTVp0396WlV0ETw_e-_3_D34I3QN-BhBiiUkcQcwgwZgCxoSQCzQHjnGII8Yu0XwEwpG4RjfeHzAGIhjM0IxQQSKezBHb2FY3na2C1NatdLoIvstuH2zsXv8M27IJUulsVxbBqtmVdudkuz_eoisjK6_vprlAny_rj_Qt3L6_btLVNlTAGQmZ1kApxbGhOaEJUUxFXBVCyFxIJvJcxGASboAwnkuIuBRCQ6F4DsCUMXSBnk69rbNfvfZdVpde6aqSjba9z0QSx4IyMYDkBCpnvXfaZK0ra-mOGeBsdJX9dTWEHqb2Pq91cY5Mcob743SXXsnKONmo0p-xiGGKxVizPGFe7nR2sL1rBif_Pf4Fm2Z8Vg</recordid><startdate>199003</startdate><enddate>199003</enddate><creator>Nakstad, P. H.</creator><creator>Skalpe, I. O.</creator><creator>Bakke, S. J.</creator><creator>Aanonsen, N. O.</creator><creator>Ganes, T.</creator><general>SAGE Publications</general><general>Taylor &amp; Francis</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199003</creationdate><title>Iopentol Compared with Iohexol in Carotid Angiography</title><author>Nakstad, P. H. ; Skalpe, I. O. ; Bakke, S. J. ; Aanonsen, N. O. ; Ganes, T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1652-5ee133308f3b2392c5c46cd77ab7a57bb781f96f1256ba146a77e1dc6b115cff3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Cerebral Angiography</topic><topic>Contrast Media</topic><topic>Double-Blind Method</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Iodobenzoates</topic><topic>Iohexol</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Random Allocation</topic><topic>Triiodobenzoic Acids</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nakstad, P. H.</creatorcontrib><creatorcontrib>Skalpe, I. O.</creatorcontrib><creatorcontrib>Bakke, S. J.</creatorcontrib><creatorcontrib>Aanonsen, N. O.</creatorcontrib><creatorcontrib>Ganes, T.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Acta radiologica (1987)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nakstad, P. H.</au><au>Skalpe, I. O.</au><au>Bakke, S. J.</au><au>Aanonsen, N. O.</au><au>Ganes, T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Iopentol Compared with Iohexol in Carotid Angiography: A Double Blind Crossover Test of a New Non-Ionic Contrast Medium</atitle><jtitle>Acta radiologica (1987)</jtitle><addtitle>Acta Radiol</addtitle><date>1990-03</date><risdate>1990</risdate><volume>31</volume><issue>2</issue><spage>221</spage><epage>222</epage><pages>221-222</pages><issn>0284-1851</issn><eissn>1600-0455</eissn><coden>ACRAE3</coden><abstract>A randomized double blind crossover test with iohexol and the new non-ionic contrast medium iopentol in 12 patients undergoing carotid angiography showed no difference in tolerability, EEG, ECG, neurologic status or image quality. Iopentol seems to be well suited for cerebral angiography.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>2372469</pmid><doi>10.1177/028418519003100222</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0284-1851
ispartof Acta radiologica (1987), 1990-03, Vol.31 (2), p.221-222
issn 0284-1851
1600-0455
language eng
recordid cdi_proquest_miscellaneous_79887357
source MEDLINE; Taylor & Francis Journals Complete
subjects Adult
Aged
Biological and medical sciences
Cerebral Angiography
Contrast Media
Double-Blind Method
Humans
Investigative techniques, diagnostic techniques (general aspects)
Iodobenzoates
Iohexol
Medical sciences
Middle Aged
Radiodiagnosis. Nmr imagery. Nmr spectrometry
Random Allocation
Triiodobenzoic Acids
title Iopentol Compared with Iohexol in Carotid Angiography: A Double Blind Crossover Test of a New Non-Ionic Contrast Medium
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T07%3A01%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Iopentol%20Compared%20with%20Iohexol%20in%20Carotid%20Angiography:%20A%20Double%20Blind%20Crossover%20Test%20of%20a%20New%20Non-Ionic%20Contrast%20Medium&rft.jtitle=Acta%20radiologica%20(1987)&rft.au=Nakstad,%20P.%20H.&rft.date=1990-03&rft.volume=31&rft.issue=2&rft.spage=221&rft.epage=222&rft.pages=221-222&rft.issn=0284-1851&rft.eissn=1600-0455&rft.coden=ACRAE3&rft_id=info:doi/10.1177/028418519003100222&rft_dat=%3Cproquest_cross%3E79887357%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79887357&rft_id=info:pmid/2372469&rft_sage_id=10.1177_028418519003100222&rfr_iscdi=true