Computerised evaluation of fetal heart rate in post‐term fetuses: long term variation

Computerised fetal heart rate records were obtained between 1987 and 1993 using the Sonicaid System 8000 for a cross‐sectional study of postdates fetal heart rate variation; 567 singleton pregnancies at 41 and 43 weeks provided 1502 records. In all cases gestational age had been verified by ultrasou...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BJOG : an international journal of obstetrics and gynaecology 1998-03, Vol.105 (3), p.356-359
Hauptverfasser: Mandruzzato, Giampaolo, Meir, Yoram J., D'Ottavio, Giuseppina, Conoscenti, Giancarlo, Dawes, Geoffrey S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 359
container_issue 3
container_start_page 356
container_title BJOG : an international journal of obstetrics and gynaecology
container_volume 105
creator Mandruzzato, Giampaolo
Meir, Yoram J.
D'Ottavio, Giuseppina
Conoscenti, Giancarlo
Dawes, Geoffrey S.
description Computerised fetal heart rate records were obtained between 1987 and 1993 using the Sonicaid System 8000 for a cross‐sectional study of postdates fetal heart rate variation; 567 singleton pregnancies at 41 and 43 weeks provided 1502 records. In all cases gestational age had been verified by ultrasound examination in early pregnancy. The mean minute range of the long term pulse interval variation, which is known to be correlated with fetal oxygenation was found to decrease progressively from an average value of 48.5 ms at 41 weeks to 46.4 ms and 42.4 ms at 42 and 43 or more weeks, respectively. When conservative management of postdate pregnancies is chosen, accurate measurements are needed to follow the evolution of fetal condition. Reference values for calculated pulse interval variation at later gestational ages are now provided.
doi_str_mv 10.1111/j.1471-0528.1998.tb10100.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79770407</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79770407</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3986-dccbe50f707be22be703e739fd59a7a9566a1ec181dbe8b15c2a2b19870c94c43</originalsourceid><addsrcrecordid>eNqVkM1KxDAUhYMo4-8jCEHEXetNM22aWQg6-IvgRnEZ0vRWO_RnTNpx3PkIPqNPYjtTZm82CTnn3Hv4CDlh4LPunM98NhbMgzCIfSZl7DcJAwbgL7fI3kbaXr3BAx7Eu2TfuRkAiwLgIzKSIecAsEdep3U5bxu0ucOU4kIXrW7yuqJ1RjNsdEHfUduGWt0gzSs6r13z-_3TBcpebx26CS3q6o2uvhba5qv8IdnJdOHwaLgPyMvN9fP0znt8ur2fXj56hss48lJjEgwhEyASDIIEBXAUXGZpKLXQMowizdCwmKUJxgkLTaCDhMlYgJFjM-YH5Gw9d27rjxZdo8rcGSwKXWHdOiWkEDAG0Rkna6OxtXMWMzW3eantl2Kgeqpqpnp0qkeneqpqoKqWXfh42NImJaab6ICx008HXTuji8zqyuRuYwtYBJL1HS7Wts-8wK9_FFBXD088jPgfkZKWBQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79770407</pqid></control><display><type>article</type><title>Computerised evaluation of fetal heart rate in post‐term fetuses: long term variation</title><source>MEDLINE</source><source>Access via Wiley Online Library</source><source>Alma/SFX Local Collection</source><creator>Mandruzzato, Giampaolo ; Meir, Yoram J. ; D'Ottavio, Giuseppina ; Conoscenti, Giancarlo ; Dawes, Geoffrey S.</creator><creatorcontrib>Mandruzzato, Giampaolo ; Meir, Yoram J. ; D'Ottavio, Giuseppina ; Conoscenti, Giancarlo ; Dawes, Geoffrey S.</creatorcontrib><description>Computerised fetal heart rate records were obtained between 1987 and 1993 using the Sonicaid System 8000 for a cross‐sectional study of postdates fetal heart rate variation; 567 singleton pregnancies at 41 and 43 weeks provided 1502 records. In all cases gestational age had been verified by ultrasound examination in early pregnancy. The mean minute range of the long term pulse interval variation, which is known to be correlated with fetal oxygenation was found to decrease progressively from an average value of 48.5 ms at 41 weeks to 46.4 ms and 42.4 ms at 42 and 43 or more weeks, respectively. When conservative management of postdate pregnancies is chosen, accurate measurements are needed to follow the evolution of fetal condition. Reference values for calculated pulse interval variation at later gestational ages are now provided.</description><identifier>ISSN: 1470-0328</identifier><identifier>ISSN: 0306-5456</identifier><identifier>EISSN: 1471-0528</identifier><identifier>EISSN: 1365-215X</identifier><identifier>DOI: 10.1111/j.1471-0528.1998.tb10100.x</identifier><identifier>PMID: 9533000</identifier><identifier>CODEN: BJOGAS</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>Biological and medical sciences ; Cardiotocography - methods ; Cardiotocography - standards ; Cross-Sectional Studies ; Decision Making, Computer-Assisted ; Female ; Gestational Age ; Gynecology. Andrology. Obstetrics ; Heart Rate, Fetal - physiology ; Humans ; Infant, Postmature - physiology ; Management. Prenatal diagnosis ; Medical sciences ; Pregnancy ; Pregnancy Outcome ; Pregnancy. Fetus. Placenta ; Reference Values</subject><ispartof>BJOG : an international journal of obstetrics and gynaecology, 1998-03, Vol.105 (3), p.356-359</ispartof><rights>1998 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3986-dccbe50f707be22be703e739fd59a7a9566a1ec181dbe8b15c2a2b19870c94c43</citedby><cites>FETCH-LOGICAL-c3986-dccbe50f707be22be703e739fd59a7a9566a1ec181dbe8b15c2a2b19870c94c43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1471-0528.1998.tb10100.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1471-0528.1998.tb10100.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2160917$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9533000$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mandruzzato, Giampaolo</creatorcontrib><creatorcontrib>Meir, Yoram J.</creatorcontrib><creatorcontrib>D'Ottavio, Giuseppina</creatorcontrib><creatorcontrib>Conoscenti, Giancarlo</creatorcontrib><creatorcontrib>Dawes, Geoffrey S.</creatorcontrib><title>Computerised evaluation of fetal heart rate in post‐term fetuses: long term variation</title><title>BJOG : an international journal of obstetrics and gynaecology</title><addtitle>Br J Obstet Gynaecol</addtitle><description>Computerised fetal heart rate records were obtained between 1987 and 1993 using the Sonicaid System 8000 for a cross‐sectional study of postdates fetal heart rate variation; 567 singleton pregnancies at 41 and 43 weeks provided 1502 records. In all cases gestational age had been verified by ultrasound examination in early pregnancy. The mean minute range of the long term pulse interval variation, which is known to be correlated with fetal oxygenation was found to decrease progressively from an average value of 48.5 ms at 41 weeks to 46.4 ms and 42.4 ms at 42 and 43 or more weeks, respectively. When conservative management of postdate pregnancies is chosen, accurate measurements are needed to follow the evolution of fetal condition. Reference values for calculated pulse interval variation at later gestational ages are now provided.</description><subject>Biological and medical sciences</subject><subject>Cardiotocography - methods</subject><subject>Cardiotocography - standards</subject><subject>Cross-Sectional Studies</subject><subject>Decision Making, Computer-Assisted</subject><subject>Female</subject><subject>Gestational Age</subject><subject>Gynecology. Andrology. Obstetrics</subject><subject>Heart Rate, Fetal - physiology</subject><subject>Humans</subject><subject>Infant, Postmature - physiology</subject><subject>Management. Prenatal diagnosis</subject><subject>Medical sciences</subject><subject>Pregnancy</subject><subject>Pregnancy Outcome</subject><subject>Pregnancy. Fetus. Placenta</subject><subject>Reference Values</subject><issn>1470-0328</issn><issn>0306-5456</issn><issn>1471-0528</issn><issn>1365-215X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqVkM1KxDAUhYMo4-8jCEHEXetNM22aWQg6-IvgRnEZ0vRWO_RnTNpx3PkIPqNPYjtTZm82CTnn3Hv4CDlh4LPunM98NhbMgzCIfSZl7DcJAwbgL7fI3kbaXr3BAx7Eu2TfuRkAiwLgIzKSIecAsEdep3U5bxu0ucOU4kIXrW7yuqJ1RjNsdEHfUduGWt0gzSs6r13z-_3TBcpebx26CS3q6o2uvhba5qv8IdnJdOHwaLgPyMvN9fP0znt8ur2fXj56hss48lJjEgwhEyASDIIEBXAUXGZpKLXQMowizdCwmKUJxgkLTaCDhMlYgJFjM-YH5Gw9d27rjxZdo8rcGSwKXWHdOiWkEDAG0Rkna6OxtXMWMzW3eantl2Kgeqpqpnp0qkeneqpqoKqWXfh42NImJaab6ICx008HXTuji8zqyuRuYwtYBJL1HS7Wts-8wK9_FFBXD088jPgfkZKWBQ</recordid><startdate>199803</startdate><enddate>199803</enddate><creator>Mandruzzato, Giampaolo</creator><creator>Meir, Yoram J.</creator><creator>D'Ottavio, Giuseppina</creator><creator>Conoscenti, Giancarlo</creator><creator>Dawes, Geoffrey S.</creator><general>Blackwell Publishing Ltd</general><general>Blackwell</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199803</creationdate><title>Computerised evaluation of fetal heart rate in post‐term fetuses: long term variation</title><author>Mandruzzato, Giampaolo ; Meir, Yoram J. ; D'Ottavio, Giuseppina ; Conoscenti, Giancarlo ; Dawes, Geoffrey S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3986-dccbe50f707be22be703e739fd59a7a9566a1ec181dbe8b15c2a2b19870c94c43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Biological and medical sciences</topic><topic>Cardiotocography - methods</topic><topic>Cardiotocography - standards</topic><topic>Cross-Sectional Studies</topic><topic>Decision Making, Computer-Assisted</topic><topic>Female</topic><topic>Gestational Age</topic><topic>Gynecology. Andrology. Obstetrics</topic><topic>Heart Rate, Fetal - physiology</topic><topic>Humans</topic><topic>Infant, Postmature - physiology</topic><topic>Management. Prenatal diagnosis</topic><topic>Medical sciences</topic><topic>Pregnancy</topic><topic>Pregnancy Outcome</topic><topic>Pregnancy. Fetus. Placenta</topic><topic>Reference Values</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mandruzzato, Giampaolo</creatorcontrib><creatorcontrib>Meir, Yoram J.</creatorcontrib><creatorcontrib>D'Ottavio, Giuseppina</creatorcontrib><creatorcontrib>Conoscenti, Giancarlo</creatorcontrib><creatorcontrib>Dawes, Geoffrey S.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>BJOG : an international journal of obstetrics and gynaecology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mandruzzato, Giampaolo</au><au>Meir, Yoram J.</au><au>D'Ottavio, Giuseppina</au><au>Conoscenti, Giancarlo</au><au>Dawes, Geoffrey S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computerised evaluation of fetal heart rate in post‐term fetuses: long term variation</atitle><jtitle>BJOG : an international journal of obstetrics and gynaecology</jtitle><addtitle>Br J Obstet Gynaecol</addtitle><date>1998-03</date><risdate>1998</risdate><volume>105</volume><issue>3</issue><spage>356</spage><epage>359</epage><pages>356-359</pages><issn>1470-0328</issn><issn>0306-5456</issn><eissn>1471-0528</eissn><eissn>1365-215X</eissn><coden>BJOGAS</coden><abstract>Computerised fetal heart rate records were obtained between 1987 and 1993 using the Sonicaid System 8000 for a cross‐sectional study of postdates fetal heart rate variation; 567 singleton pregnancies at 41 and 43 weeks provided 1502 records. In all cases gestational age had been verified by ultrasound examination in early pregnancy. The mean minute range of the long term pulse interval variation, which is known to be correlated with fetal oxygenation was found to decrease progressively from an average value of 48.5 ms at 41 weeks to 46.4 ms and 42.4 ms at 42 and 43 or more weeks, respectively. When conservative management of postdate pregnancies is chosen, accurate measurements are needed to follow the evolution of fetal condition. Reference values for calculated pulse interval variation at later gestational ages are now provided.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>9533000</pmid><doi>10.1111/j.1471-0528.1998.tb10100.x</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1470-0328
ispartof BJOG : an international journal of obstetrics and gynaecology, 1998-03, Vol.105 (3), p.356-359
issn 1470-0328
0306-5456
1471-0528
1365-215X
language eng
recordid cdi_proquest_miscellaneous_79770407
source MEDLINE; Access via Wiley Online Library; Alma/SFX Local Collection
subjects Biological and medical sciences
Cardiotocography - methods
Cardiotocography - standards
Cross-Sectional Studies
Decision Making, Computer-Assisted
Female
Gestational Age
Gynecology. Andrology. Obstetrics
Heart Rate, Fetal - physiology
Humans
Infant, Postmature - physiology
Management. Prenatal diagnosis
Medical sciences
Pregnancy
Pregnancy Outcome
Pregnancy. Fetus. Placenta
Reference Values
title Computerised evaluation of fetal heart rate in post‐term fetuses: long term variation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T00%3A33%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computerised%20evaluation%20of%20fetal%20heart%20rate%20in%20post%E2%80%90term%20fetuses:%20long%20term%20variation&rft.jtitle=BJOG%20:%20an%20international%20journal%20of%20obstetrics%20and%20gynaecology&rft.au=Mandruzzato,%20Giampaolo&rft.date=1998-03&rft.volume=105&rft.issue=3&rft.spage=356&rft.epage=359&rft.pages=356-359&rft.issn=1470-0328&rft.eissn=1471-0528&rft.coden=BJOGAS&rft_id=info:doi/10.1111/j.1471-0528.1998.tb10100.x&rft_dat=%3Cproquest_cross%3E79770407%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79770407&rft_id=info:pmid/9533000&rfr_iscdi=true