Long-term compliance of laryngectomized patients with a specialized pulmonary rehabilitation device : Provox Stomafilter

Previous studies have demonstrated the positive effect of a heat and moisture exchanger (HME) on the respiratory system in patients after laryngectomy. However, patient compliance with these devices was reduced by device-related problems and troublesome combination with a voice prosthesis. Recently...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Laryngoscope 1998-02, Vol.108 (2), p.257-260
Hauptverfasser: ACKERSTAFF, A. H, HILGERS, F. J. M, BALM, A. J. M, BING TAN, I
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 260
container_issue 2
container_start_page 257
container_title The Laryngoscope
container_volume 108
creator ACKERSTAFF, A. H
HILGERS, F. J. M
BALM, A. J. M
BING TAN, I
description Previous studies have demonstrated the positive effect of a heat and moisture exchanger (HME) on the respiratory system in patients after laryngectomy. However, patient compliance with these devices was reduced by device-related problems and troublesome combination with a voice prosthesis. Recently a more specialized device has become available. This is an HME combined with a valve for easy digital occlusion of the stoma (Provox Stomafilter; Hörby, Sweden). In the authors' initial study of this revised device, a clear improvement in short-term compliance was demonstrated. To investigate long-term compliance, 69 consecutive patients were interviewed by means of a structured questionnaire. The results show that all patients expressed their satisfaction with the valve used for digital occlusion of the stoma. Sixty-three percent of the patients reported that voicing was facilitated. Subjective intelligibility improved in 55% of the patients. Previous problems with other devices (e.g., plaster adherence, skin irritation, and handling) were clearly diminished, increasing the long-term compliance of the patients to 78%. This new HME can be considered as a beneficial pulmonary rehabilitation tool for laryngectomized patients.
doi_str_mv 10.1097/00005537-199802000-00018
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79689684</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79689684</sourcerecordid><originalsourceid>FETCH-LOGICAL-c284t-7e89933020dedcce8c814689de26a9d8ea929034c7b751be97cc56f8751a66e53</originalsourceid><addsrcrecordid>eNo9UF1LHDEUDUWx67Y_oZAH8W00mUwmiW9lsVVYUNBC34Zs5o6mZCbTZGbV_vredtcNXMLlfFzOIYRydsGZUZcMn5RCFdwYzUrcChyuP5AFl4IXlTHyiCwYK0WhZfnzIznN-RcylJDshJyYSgmm9IK8ruPwVEyQeupiPwZvBwc0djTY9DY8gZti7_9AS0c7eRimTF_89EwtzSM4b8MOm0MfBxTQBM9244OfkB0H2sLWo90VvU9xG1_pA7rZzge894kcdzZk-Lz_l-THt-vH1U2xvvt-u_q6Llypq6lQoI0RAiO20DoH2mle1dq0UNbWtBqsKQ0TlVMbJfkGjHJO1p3GxdY1SLEk5zvfMcXfM-Sp6X12EIIdIM65UQbdal0hUe-ILsWcE3TNmHyPoRrOmn-lN--lN4fSm_-lo_TL_sa86aE9CPctI362x212NnQJS_b5QCsxUV0J8RdNYoxY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79689684</pqid></control><display><type>article</type><title>Long-term compliance of laryngectomized patients with a specialized pulmonary rehabilitation device : Provox Stomafilter</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><source>Journals@Ovid Ovid Autoload</source><creator>ACKERSTAFF, A. H ; HILGERS, F. J. M ; BALM, A. J. M ; BING TAN, I</creator><creatorcontrib>ACKERSTAFF, A. H ; HILGERS, F. J. M ; BALM, A. J. M ; BING TAN, I</creatorcontrib><description>Previous studies have demonstrated the positive effect of a heat and moisture exchanger (HME) on the respiratory system in patients after laryngectomy. However, patient compliance with these devices was reduced by device-related problems and troublesome combination with a voice prosthesis. Recently a more specialized device has become available. This is an HME combined with a valve for easy digital occlusion of the stoma (Provox Stomafilter; Hörby, Sweden). In the authors' initial study of this revised device, a clear improvement in short-term compliance was demonstrated. To investigate long-term compliance, 69 consecutive patients were interviewed by means of a structured questionnaire. The results show that all patients expressed their satisfaction with the valve used for digital occlusion of the stoma. Sixty-three percent of the patients reported that voicing was facilitated. Subjective intelligibility improved in 55% of the patients. Previous problems with other devices (e.g., plaster adherence, skin irritation, and handling) were clearly diminished, increasing the long-term compliance of the patients to 78%. This new HME can be considered as a beneficial pulmonary rehabilitation tool for laryngectomized patients.</description><identifier>ISSN: 0023-852X</identifier><identifier>EISSN: 1531-4995</identifier><identifier>DOI: 10.1097/00005537-199802000-00018</identifier><identifier>PMID: 9473078</identifier><identifier>CODEN: LARYA8</identifier><language>eng</language><publisher>Honboken, NJ: Wiley-Blackwell</publisher><subject>Adult ; Aged ; Aged, 80 and over ; Biological and medical sciences ; Female ; Filtration - instrumentation ; Follow-Up Studies ; Head and neck surgery. Maxillofacial surgery. Dental surgery. Orthodontics ; Hot Temperature ; Humans ; Humidity ; Laryngectomy - rehabilitation ; Larynx, Artificial ; Male ; Medical sciences ; Middle Aged ; Patient Compliance ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Surgery of the upper aerodigestive tract ; Surgical Stomas ; Time Factors</subject><ispartof>The Laryngoscope, 1998-02, Vol.108 (2), p.257-260</ispartof><rights>1998 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c284t-7e89933020dedcce8c814689de26a9d8ea929034c7b751be97cc56f8751a66e53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2146643$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9473078$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ACKERSTAFF, A. H</creatorcontrib><creatorcontrib>HILGERS, F. J. M</creatorcontrib><creatorcontrib>BALM, A. J. M</creatorcontrib><creatorcontrib>BING TAN, I</creatorcontrib><title>Long-term compliance of laryngectomized patients with a specialized pulmonary rehabilitation device : Provox Stomafilter</title><title>The Laryngoscope</title><addtitle>Laryngoscope</addtitle><description>Previous studies have demonstrated the positive effect of a heat and moisture exchanger (HME) on the respiratory system in patients after laryngectomy. However, patient compliance with these devices was reduced by device-related problems and troublesome combination with a voice prosthesis. Recently a more specialized device has become available. This is an HME combined with a valve for easy digital occlusion of the stoma (Provox Stomafilter; Hörby, Sweden). In the authors' initial study of this revised device, a clear improvement in short-term compliance was demonstrated. To investigate long-term compliance, 69 consecutive patients were interviewed by means of a structured questionnaire. The results show that all patients expressed their satisfaction with the valve used for digital occlusion of the stoma. Sixty-three percent of the patients reported that voicing was facilitated. Subjective intelligibility improved in 55% of the patients. Previous problems with other devices (e.g., plaster adherence, skin irritation, and handling) were clearly diminished, increasing the long-term compliance of the patients to 78%. This new HME can be considered as a beneficial pulmonary rehabilitation tool for laryngectomized patients.</description><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Biological and medical sciences</subject><subject>Female</subject><subject>Filtration - instrumentation</subject><subject>Follow-Up Studies</subject><subject>Head and neck surgery. Maxillofacial surgery. Dental surgery. Orthodontics</subject><subject>Hot Temperature</subject><subject>Humans</subject><subject>Humidity</subject><subject>Laryngectomy - rehabilitation</subject><subject>Larynx, Artificial</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Patient Compliance</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Surgery of the upper aerodigestive tract</subject><subject>Surgical Stomas</subject><subject>Time Factors</subject><issn>0023-852X</issn><issn>1531-4995</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9UF1LHDEUDUWx67Y_oZAH8W00mUwmiW9lsVVYUNBC34Zs5o6mZCbTZGbV_vredtcNXMLlfFzOIYRydsGZUZcMn5RCFdwYzUrcChyuP5AFl4IXlTHyiCwYK0WhZfnzIznN-RcylJDshJyYSgmm9IK8ruPwVEyQeupiPwZvBwc0djTY9DY8gZti7_9AS0c7eRimTF_89EwtzSM4b8MOm0MfBxTQBM9244OfkB0H2sLWo90VvU9xG1_pA7rZzge894kcdzZk-Lz_l-THt-vH1U2xvvt-u_q6Llypq6lQoI0RAiO20DoH2mle1dq0UNbWtBqsKQ0TlVMbJfkGjHJO1p3GxdY1SLEk5zvfMcXfM-Sp6X12EIIdIM65UQbdal0hUe-ILsWcE3TNmHyPoRrOmn-lN--lN4fSm_-lo_TL_sa86aE9CPctI362x212NnQJS_b5QCsxUV0J8RdNYoxY</recordid><startdate>19980201</startdate><enddate>19980201</enddate><creator>ACKERSTAFF, A. H</creator><creator>HILGERS, F. J. M</creator><creator>BALM, A. J. M</creator><creator>BING TAN, I</creator><general>Wiley-Blackwell</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>8BM</scope></search><sort><creationdate>19980201</creationdate><title>Long-term compliance of laryngectomized patients with a specialized pulmonary rehabilitation device : Provox Stomafilter</title><author>ACKERSTAFF, A. H ; HILGERS, F. J. M ; BALM, A. J. M ; BING TAN, I</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c284t-7e89933020dedcce8c814689de26a9d8ea929034c7b751be97cc56f8751a66e53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Biological and medical sciences</topic><topic>Female</topic><topic>Filtration - instrumentation</topic><topic>Follow-Up Studies</topic><topic>Head and neck surgery. Maxillofacial surgery. Dental surgery. Orthodontics</topic><topic>Hot Temperature</topic><topic>Humans</topic><topic>Humidity</topic><topic>Laryngectomy - rehabilitation</topic><topic>Larynx, Artificial</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Patient Compliance</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Surgery of the upper aerodigestive tract</topic><topic>Surgical Stomas</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ACKERSTAFF, A. H</creatorcontrib><creatorcontrib>HILGERS, F. J. M</creatorcontrib><creatorcontrib>BALM, A. J. M</creatorcontrib><creatorcontrib>BING TAN, I</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>ComDisDome</collection><jtitle>The Laryngoscope</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ACKERSTAFF, A. H</au><au>HILGERS, F. J. M</au><au>BALM, A. J. M</au><au>BING TAN, I</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Long-term compliance of laryngectomized patients with a specialized pulmonary rehabilitation device : Provox Stomafilter</atitle><jtitle>The Laryngoscope</jtitle><addtitle>Laryngoscope</addtitle><date>1998-02-01</date><risdate>1998</risdate><volume>108</volume><issue>2</issue><spage>257</spage><epage>260</epage><pages>257-260</pages><issn>0023-852X</issn><eissn>1531-4995</eissn><coden>LARYA8</coden><abstract>Previous studies have demonstrated the positive effect of a heat and moisture exchanger (HME) on the respiratory system in patients after laryngectomy. However, patient compliance with these devices was reduced by device-related problems and troublesome combination with a voice prosthesis. Recently a more specialized device has become available. This is an HME combined with a valve for easy digital occlusion of the stoma (Provox Stomafilter; Hörby, Sweden). In the authors' initial study of this revised device, a clear improvement in short-term compliance was demonstrated. To investigate long-term compliance, 69 consecutive patients were interviewed by means of a structured questionnaire. The results show that all patients expressed their satisfaction with the valve used for digital occlusion of the stoma. Sixty-three percent of the patients reported that voicing was facilitated. Subjective intelligibility improved in 55% of the patients. Previous problems with other devices (e.g., plaster adherence, skin irritation, and handling) were clearly diminished, increasing the long-term compliance of the patients to 78%. This new HME can be considered as a beneficial pulmonary rehabilitation tool for laryngectomized patients.</abstract><cop>Honboken, NJ</cop><pub>Wiley-Blackwell</pub><pmid>9473078</pmid><doi>10.1097/00005537-199802000-00018</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0023-852X
ispartof The Laryngoscope, 1998-02, Vol.108 (2), p.257-260
issn 0023-852X
1531-4995
language eng
recordid cdi_proquest_miscellaneous_79689684
source MEDLINE; Wiley Online Library Journals Frontfile Complete; Journals@Ovid Ovid Autoload
subjects Adult
Aged
Aged, 80 and over
Biological and medical sciences
Female
Filtration - instrumentation
Follow-Up Studies
Head and neck surgery. Maxillofacial surgery. Dental surgery. Orthodontics
Hot Temperature
Humans
Humidity
Laryngectomy - rehabilitation
Larynx, Artificial
Male
Medical sciences
Middle Aged
Patient Compliance
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Surgery of the upper aerodigestive tract
Surgical Stomas
Time Factors
title Long-term compliance of laryngectomized patients with a specialized pulmonary rehabilitation device : Provox Stomafilter
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T17%3A53%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Long-term%20compliance%20of%20laryngectomized%20patients%20with%20a%20specialized%20pulmonary%20rehabilitation%20device%20:%20Provox%20Stomafilter&rft.jtitle=The%20Laryngoscope&rft.au=ACKERSTAFF,%20A.%20H&rft.date=1998-02-01&rft.volume=108&rft.issue=2&rft.spage=257&rft.epage=260&rft.pages=257-260&rft.issn=0023-852X&rft.eissn=1531-4995&rft.coden=LARYA8&rft_id=info:doi/10.1097/00005537-199802000-00018&rft_dat=%3Cproquest_cross%3E79689684%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79689684&rft_id=info:pmid/9473078&rfr_iscdi=true