Laser doppler blood flow measurements of common cutaneous donor sites for reconstructive surgery

The purpose of this study was to evaluate cutaneous blood flow in regions commonly used as donor sites in reconstructive surgery in order to better establish normal flow ranges. Flow was measured with the TSI Laserflo BPM 403 in 27 healthy volunteers and compared to the flow in uncomplicated postope...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Plastic and reconstructive surgery (1963) 1990-04, Vol.85 (4), p.581-586
Hauptverfasser: GOLDBERG, J, SEPKA, R. S, PERONA, B. P, PEDERSON, W. C, KLITZMAN, B
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 586
container_issue 4
container_start_page 581
container_title Plastic and reconstructive surgery (1963)
container_volume 85
creator GOLDBERG, J
SEPKA, R. S
PERONA, B. P
PEDERSON, W. C
KLITZMAN, B
description The purpose of this study was to evaluate cutaneous blood flow in regions commonly used as donor sites in reconstructive surgery in order to better establish normal flow ranges. Flow was measured with the TSI Laserflo BPM 403 in 27 healthy volunteers and compared to the flow in uncomplicated postoperative autologous tissue transplants. The forehead produced the highest flow, with an average value of 6.50 +/- 0.31 (mean +/- SE), and the dorsalis pedis had the lowest flow, with an average value of 0.60 +/- 0.04. Gender differences were noted in the latissimus dorsi, pectoralis major, and rectus abdominis areas. There were no significant differences between smokers and nonsmokers, hand dominance, musculocutaneous and fasciocutaneous tissues, or supine and sitting body positions. Flow levels in volunteers were similar to those in postoperative surviving autologous tissue transplants. The site-specific flow and flow changes over long time periods (hours) have helped clinical monitoring of 77 patients in the last 24 months. In every case identified by the flowmeter as decreased perfusion, a definite etiology for low reduction was documented. Complications occurred in 12 patients, and the rate of salvaging compromised tissue has increased from 50 percent using temperature monitoring and clinical observation to 83 percent with the computerized laser Doppler flowmeter.
doi_str_mv 10.1097/00006534-199004000-00013
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79683795</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79683795</sourcerecordid><originalsourceid>FETCH-LOGICAL-c406t-ef202214acfe0a5252090339192e69dfb23e2e6aa178aa1576938f7f0558514d3</originalsourceid><addsrcrecordid>eNpFkE1LxDAQhoMo67r6E4Rc9FbNZ9McZfELFrzoOWbTiVTaZk1aZf-90a1rIJkZ5n0nw4MQpuSKEq2uST6l5KKgWhMiclXkS_kBmlPJdCGYYIdoTghnBSWSHaOTlN6zQvFSztCMUaW1knP0urIJIq7DZtPmuG5DqLFvwxfuwKYxQgf9kHDw2IWuCz1242B7CGPKnj5EnJoBEvY5i-BCn4Y4uqH5BJzNbxC3p-jI2zbB2RQX6OXu9nn5UKye7h-XN6vCCVIOBXhGGKPCOg_ESiYZ0YRzTTWDUtd-zTjkzFqqqvxIVWpeeeWJlJWkouYLdLmbu4nhY4Q0mK5JDtp2t61Ruqy40jILq53QxZBSBG82sels3BpKzA9c8wfX7OGaX7jZej79Ma47qPfGiWbuX0x9m5xtfbS9a9L_fK2EZkTwb_yigq8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79683795</pqid></control><display><type>article</type><title>Laser doppler blood flow measurements of common cutaneous donor sites for reconstructive surgery</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>GOLDBERG, J ; SEPKA, R. S ; PERONA, B. P ; PEDERSON, W. C ; KLITZMAN, B</creator><creatorcontrib>GOLDBERG, J ; SEPKA, R. S ; PERONA, B. P ; PEDERSON, W. C ; KLITZMAN, B</creatorcontrib><description>The purpose of this study was to evaluate cutaneous blood flow in regions commonly used as donor sites in reconstructive surgery in order to better establish normal flow ranges. Flow was measured with the TSI Laserflo BPM 403 in 27 healthy volunteers and compared to the flow in uncomplicated postoperative autologous tissue transplants. The forehead produced the highest flow, with an average value of 6.50 +/- 0.31 (mean +/- SE), and the dorsalis pedis had the lowest flow, with an average value of 0.60 +/- 0.04. Gender differences were noted in the latissimus dorsi, pectoralis major, and rectus abdominis areas. There were no significant differences between smokers and nonsmokers, hand dominance, musculocutaneous and fasciocutaneous tissues, or supine and sitting body positions. Flow levels in volunteers were similar to those in postoperative surviving autologous tissue transplants. The site-specific flow and flow changes over long time periods (hours) have helped clinical monitoring of 77 patients in the last 24 months. In every case identified by the flowmeter as decreased perfusion, a definite etiology for low reduction was documented. Complications occurred in 12 patients, and the rate of salvaging compromised tissue has increased from 50 percent using temperature monitoring and clinical observation to 83 percent with the computerized laser Doppler flowmeter.</description><identifier>ISSN: 0032-1052</identifier><identifier>EISSN: 1529-4242</identifier><identifier>DOI: 10.1097/00006534-199004000-00013</identifier><identifier>PMID: 2179975</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott Williams &amp; Wilkins</publisher><subject>Biological and medical sciences ; Blood Flow Velocity ; Blood Volume ; Dermatology ; Female ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Lasers ; Male ; Medical sciences ; Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques ; Regional Blood Flow ; Skin - blood supply ; Skin Transplantation</subject><ispartof>Plastic and reconstructive surgery (1963), 1990-04, Vol.85 (4), p.581-586</ispartof><rights>1991 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c406t-ef202214acfe0a5252090339192e69dfb23e2e6aa178aa1576938f7f0558514d3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=19749204$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2179975$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>GOLDBERG, J</creatorcontrib><creatorcontrib>SEPKA, R. S</creatorcontrib><creatorcontrib>PERONA, B. P</creatorcontrib><creatorcontrib>PEDERSON, W. C</creatorcontrib><creatorcontrib>KLITZMAN, B</creatorcontrib><title>Laser doppler blood flow measurements of common cutaneous donor sites for reconstructive surgery</title><title>Plastic and reconstructive surgery (1963)</title><addtitle>Plast Reconstr Surg</addtitle><description>The purpose of this study was to evaluate cutaneous blood flow in regions commonly used as donor sites in reconstructive surgery in order to better establish normal flow ranges. Flow was measured with the TSI Laserflo BPM 403 in 27 healthy volunteers and compared to the flow in uncomplicated postoperative autologous tissue transplants. The forehead produced the highest flow, with an average value of 6.50 +/- 0.31 (mean +/- SE), and the dorsalis pedis had the lowest flow, with an average value of 0.60 +/- 0.04. Gender differences were noted in the latissimus dorsi, pectoralis major, and rectus abdominis areas. There were no significant differences between smokers and nonsmokers, hand dominance, musculocutaneous and fasciocutaneous tissues, or supine and sitting body positions. Flow levels in volunteers were similar to those in postoperative surviving autologous tissue transplants. The site-specific flow and flow changes over long time periods (hours) have helped clinical monitoring of 77 patients in the last 24 months. In every case identified by the flowmeter as decreased perfusion, a definite etiology for low reduction was documented. Complications occurred in 12 patients, and the rate of salvaging compromised tissue has increased from 50 percent using temperature monitoring and clinical observation to 83 percent with the computerized laser Doppler flowmeter.</description><subject>Biological and medical sciences</subject><subject>Blood Flow Velocity</subject><subject>Blood Volume</subject><subject>Dermatology</subject><subject>Female</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Lasers</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques</subject><subject>Regional Blood Flow</subject><subject>Skin - blood supply</subject><subject>Skin Transplantation</subject><issn>0032-1052</issn><issn>1529-4242</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkE1LxDAQhoMo67r6E4Rc9FbNZ9McZfELFrzoOWbTiVTaZk1aZf-90a1rIJkZ5n0nw4MQpuSKEq2uST6l5KKgWhMiclXkS_kBmlPJdCGYYIdoTghnBSWSHaOTlN6zQvFSztCMUaW1knP0urIJIq7DZtPmuG5DqLFvwxfuwKYxQgf9kHDw2IWuCz1242B7CGPKnj5EnJoBEvY5i-BCn4Y4uqH5BJzNbxC3p-jI2zbB2RQX6OXu9nn5UKye7h-XN6vCCVIOBXhGGKPCOg_ESiYZ0YRzTTWDUtd-zTjkzFqqqvxIVWpeeeWJlJWkouYLdLmbu4nhY4Q0mK5JDtp2t61Ruqy40jILq53QxZBSBG82sels3BpKzA9c8wfX7OGaX7jZej79Ma47qPfGiWbuX0x9m5xtfbS9a9L_fK2EZkTwb_yigq8</recordid><startdate>19900401</startdate><enddate>19900401</enddate><creator>GOLDBERG, J</creator><creator>SEPKA, R. S</creator><creator>PERONA, B. P</creator><creator>PEDERSON, W. C</creator><creator>KLITZMAN, B</creator><general>Lippincott Williams &amp; Wilkins</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19900401</creationdate><title>Laser doppler blood flow measurements of common cutaneous donor sites for reconstructive surgery</title><author>GOLDBERG, J ; SEPKA, R. S ; PERONA, B. P ; PEDERSON, W. C ; KLITZMAN, B</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c406t-ef202214acfe0a5252090339192e69dfb23e2e6aa178aa1576938f7f0558514d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Biological and medical sciences</topic><topic>Blood Flow Velocity</topic><topic>Blood Volume</topic><topic>Dermatology</topic><topic>Female</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Lasers</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques</topic><topic>Regional Blood Flow</topic><topic>Skin - blood supply</topic><topic>Skin Transplantation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>GOLDBERG, J</creatorcontrib><creatorcontrib>SEPKA, R. S</creatorcontrib><creatorcontrib>PERONA, B. P</creatorcontrib><creatorcontrib>PEDERSON, W. C</creatorcontrib><creatorcontrib>KLITZMAN, B</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Plastic and reconstructive surgery (1963)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>GOLDBERG, J</au><au>SEPKA, R. S</au><au>PERONA, B. P</au><au>PEDERSON, W. C</au><au>KLITZMAN, B</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Laser doppler blood flow measurements of common cutaneous donor sites for reconstructive surgery</atitle><jtitle>Plastic and reconstructive surgery (1963)</jtitle><addtitle>Plast Reconstr Surg</addtitle><date>1990-04-01</date><risdate>1990</risdate><volume>85</volume><issue>4</issue><spage>581</spage><epage>586</epage><pages>581-586</pages><issn>0032-1052</issn><eissn>1529-4242</eissn><abstract>The purpose of this study was to evaluate cutaneous blood flow in regions commonly used as donor sites in reconstructive surgery in order to better establish normal flow ranges. Flow was measured with the TSI Laserflo BPM 403 in 27 healthy volunteers and compared to the flow in uncomplicated postoperative autologous tissue transplants. The forehead produced the highest flow, with an average value of 6.50 +/- 0.31 (mean +/- SE), and the dorsalis pedis had the lowest flow, with an average value of 0.60 +/- 0.04. Gender differences were noted in the latissimus dorsi, pectoralis major, and rectus abdominis areas. There were no significant differences between smokers and nonsmokers, hand dominance, musculocutaneous and fasciocutaneous tissues, or supine and sitting body positions. Flow levels in volunteers were similar to those in postoperative surviving autologous tissue transplants. The site-specific flow and flow changes over long time periods (hours) have helped clinical monitoring of 77 patients in the last 24 months. In every case identified by the flowmeter as decreased perfusion, a definite etiology for low reduction was documented. Complications occurred in 12 patients, and the rate of salvaging compromised tissue has increased from 50 percent using temperature monitoring and clinical observation to 83 percent with the computerized laser Doppler flowmeter.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott Williams &amp; Wilkins</pub><pmid>2179975</pmid><doi>10.1097/00006534-199004000-00013</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0032-1052
ispartof Plastic and reconstructive surgery (1963), 1990-04, Vol.85 (4), p.581-586
issn 0032-1052
1529-4242
language eng
recordid cdi_proquest_miscellaneous_79683795
source MEDLINE; Journals@Ovid Complete
subjects Biological and medical sciences
Blood Flow Velocity
Blood Volume
Dermatology
Female
Humans
Investigative techniques, diagnostic techniques (general aspects)
Lasers
Male
Medical sciences
Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques
Regional Blood Flow
Skin - blood supply
Skin Transplantation
title Laser doppler blood flow measurements of common cutaneous donor sites for reconstructive surgery
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T21%3A07%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Laser%20doppler%20blood%20flow%20measurements%20of%20common%20cutaneous%20donor%20sites%20for%20reconstructive%20surgery&rft.jtitle=Plastic%20and%20reconstructive%20surgery%20(1963)&rft.au=GOLDBERG,%20J&rft.date=1990-04-01&rft.volume=85&rft.issue=4&rft.spage=581&rft.epage=586&rft.pages=581-586&rft.issn=0032-1052&rft.eissn=1529-4242&rft_id=info:doi/10.1097/00006534-199004000-00013&rft_dat=%3Cproquest_cross%3E79683795%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79683795&rft_id=info:pmid/2179975&rfr_iscdi=true