Wavelet analysis of embolic heart sound detected by precordial Doppler ultrasound during continuous venous air embolism in dogs
The spectrum of the embolic heart sounds (EHS) detected by precordial Doppler ultrasound has been previously characterized, but only on small volumes of venous air embolism (VAE). We sought to determine whether real-time wavelet analysis is useful in analyzing the signals of EHS and whether the embo...
Gespeichert in:
Veröffentlicht in: | Anesthesia and analgesia 1998-02, Vol.86 (2), p.325-331 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 331 |
---|---|
container_issue | 2 |
container_start_page | 325 |
container_title | Anesthesia and analgesia |
container_volume | 86 |
creator | LUI, P.-W CHAN, B. C. B CHAN, F. H. Y POON, P. W. F HSIN WANG LAM, F. K |
description | The spectrum of the embolic heart sounds (EHS) detected by precordial Doppler ultrasound has been previously characterized, but only on small volumes of venous air embolism (VAE). We sought to determine whether real-time wavelet analysis is useful in analyzing the signals of EHS and whether the embolic power of the EHS for larger volumes of air is proportionate to the volume of VAE that has been reported for small volumes of VAE. A series of small air boli (0.01, 0.02, 0.05, 0.07, 0.1, 0.15, 0.2, 0.3, 0.4, and 0.8 mL), followed by continuous infusion of larger volumes of air (0.8, 1.6, 2.4, 4.8, and 9.6 mL), was injected into the external jugular vein through a central catheter in seven pentobarbital-anesthetized dogs. We measured the spectrum of the Doppler heart sound (DHS) in a real-time manner by using wavelet analysis at different scales. Wavelet analysis at scale = 1 yielded satisfactory results in distinguishing abnormal EHS from normal DHS with high sensitivity (100%) and good positive predictive value (100%) compared with the conventional method, which requires an anesthesiologist to listen to the audio DHS signals in a real-time manner. There was a linear relationship (y = 1.08x + 7.89, r = 0.75, P < 0.001) between the cumulative embolic power of the EHS and the air volume introduced in the form of either bolus or continuous infusion. The 95% confidence intervals for slope and intercept were 0.89-1.27 and 7.65-8.13, respectively. Our results suggest that wavelet analysis is effective as a real-time monitor and that it is possible to distinguish larger volumes of air emboli based on previous injections of small volumes of air.
The real-time wavelet analysis of the heart sound detected by precordial Doppler ultrasound may be useful in estimating larger volumes of air emboli based on previous injections of small volumes of air in anesthetized dogs. |
doi_str_mv | 10.1097/00000539-199802000-00021 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79676319</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79676319</sourcerecordid><originalsourceid>FETCH-LOGICAL-c389t-9580e91db65cf1c100df5ed4d52704b81423d0c5137db06700983e4c8b2204403</originalsourceid><addsrcrecordid>eNo9kF1L5TAQhoMo7ln1Jwi5WLzrms82uVx0dRcEbxQvS5pMNZIm3aQVzpV_fXu0noFhmJl3PngQwpT8pEQ3l2RnkuuKaq0IW5JqcUYP0IZKVleN1OoQbZYar5jW-hv6XsrrklKi6mN0rIXUTPANen8ybxBgwiaasC2-4NRjGLoUvMUvYPKES5qjww4msBM43G3xmMGm7LwJ-DqNY4CM5zBlsyrn7OMztilOPs5pLvgN4i4Yn9fVZcA-Ypeeyyk66k0ocLbGE_R48_vh6k91d3_79-rXXWW50lOlpSKgqetqaXtqKSGul-CEk6wholNUMO6IlZQ3riN1Q4hWHIRVHWNECMJP0MXn3jGnfzOUqR18sRCCibD81ja6bmpO9SJUn0KbUykZ-nbMfjB521LS7ti3X-zbPfv2g_0yer7emLsB3H5whb30f6x9U6wJfTbR-rKXMSp4zTn_D4-LjY8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79676319</pqid></control><display><type>article</type><title>Wavelet analysis of embolic heart sound detected by precordial Doppler ultrasound during continuous venous air embolism in dogs</title><source>MEDLINE</source><source>Journals@Ovid LWW Legacy Archive</source><source>Journals@Ovid Complete</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>LUI, P.-W ; CHAN, B. C. B ; CHAN, F. H. Y ; POON, P. W. F ; HSIN WANG ; LAM, F. K</creator><creatorcontrib>LUI, P.-W ; CHAN, B. C. B ; CHAN, F. H. Y ; POON, P. W. F ; HSIN WANG ; LAM, F. K</creatorcontrib><description>The spectrum of the embolic heart sounds (EHS) detected by precordial Doppler ultrasound has been previously characterized, but only on small volumes of venous air embolism (VAE). We sought to determine whether real-time wavelet analysis is useful in analyzing the signals of EHS and whether the embolic power of the EHS for larger volumes of air is proportionate to the volume of VAE that has been reported for small volumes of VAE. A series of small air boli (0.01, 0.02, 0.05, 0.07, 0.1, 0.15, 0.2, 0.3, 0.4, and 0.8 mL), followed by continuous infusion of larger volumes of air (0.8, 1.6, 2.4, 4.8, and 9.6 mL), was injected into the external jugular vein through a central catheter in seven pentobarbital-anesthetized dogs. We measured the spectrum of the Doppler heart sound (DHS) in a real-time manner by using wavelet analysis at different scales. Wavelet analysis at scale = 1 yielded satisfactory results in distinguishing abnormal EHS from normal DHS with high sensitivity (100%) and good positive predictive value (100%) compared with the conventional method, which requires an anesthesiologist to listen to the audio DHS signals in a real-time manner. There was a linear relationship (y = 1.08x + 7.89, r = 0.75, P < 0.001) between the cumulative embolic power of the EHS and the air volume introduced in the form of either bolus or continuous infusion. The 95% confidence intervals for slope and intercept were 0.89-1.27 and 7.65-8.13, respectively. Our results suggest that wavelet analysis is effective as a real-time monitor and that it is possible to distinguish larger volumes of air emboli based on previous injections of small volumes of air.
The real-time wavelet analysis of the heart sound detected by precordial Doppler ultrasound may be useful in estimating larger volumes of air emboli based on previous injections of small volumes of air in anesthetized dogs.</description><identifier>ISSN: 0003-2999</identifier><identifier>EISSN: 1526-7598</identifier><identifier>DOI: 10.1097/00000539-199802000-00021</identifier><identifier>PMID: 9459243</identifier><identifier>CODEN: AACRAT</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott</publisher><subject>Animals ; Biological and medical sciences ; Blood and lymphatic vessels ; Cardiology. Vascular system ; Dogs ; Echocardiography, Doppler ; Embolism, Air - diagnosis ; Jugular Veins ; Medical sciences ; Miscellaneous ; Regression Analysis</subject><ispartof>Anesthesia and analgesia, 1998-02, Vol.86 (2), p.325-331</ispartof><rights>1998 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c389t-9580e91db65cf1c100df5ed4d52704b81423d0c5137db06700983e4c8b2204403</citedby><cites>FETCH-LOGICAL-c389t-9580e91db65cf1c100df5ed4d52704b81423d0c5137db06700983e4c8b2204403</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27906,27907</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=2143633$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9459243$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>LUI, P.-W</creatorcontrib><creatorcontrib>CHAN, B. C. B</creatorcontrib><creatorcontrib>CHAN, F. H. Y</creatorcontrib><creatorcontrib>POON, P. W. F</creatorcontrib><creatorcontrib>HSIN WANG</creatorcontrib><creatorcontrib>LAM, F. K</creatorcontrib><title>Wavelet analysis of embolic heart sound detected by precordial Doppler ultrasound during continuous venous air embolism in dogs</title><title>Anesthesia and analgesia</title><addtitle>Anesth Analg</addtitle><description>The spectrum of the embolic heart sounds (EHS) detected by precordial Doppler ultrasound has been previously characterized, but only on small volumes of venous air embolism (VAE). We sought to determine whether real-time wavelet analysis is useful in analyzing the signals of EHS and whether the embolic power of the EHS for larger volumes of air is proportionate to the volume of VAE that has been reported for small volumes of VAE. A series of small air boli (0.01, 0.02, 0.05, 0.07, 0.1, 0.15, 0.2, 0.3, 0.4, and 0.8 mL), followed by continuous infusion of larger volumes of air (0.8, 1.6, 2.4, 4.8, and 9.6 mL), was injected into the external jugular vein through a central catheter in seven pentobarbital-anesthetized dogs. We measured the spectrum of the Doppler heart sound (DHS) in a real-time manner by using wavelet analysis at different scales. Wavelet analysis at scale = 1 yielded satisfactory results in distinguishing abnormal EHS from normal DHS with high sensitivity (100%) and good positive predictive value (100%) compared with the conventional method, which requires an anesthesiologist to listen to the audio DHS signals in a real-time manner. There was a linear relationship (y = 1.08x + 7.89, r = 0.75, P < 0.001) between the cumulative embolic power of the EHS and the air volume introduced in the form of either bolus or continuous infusion. The 95% confidence intervals for slope and intercept were 0.89-1.27 and 7.65-8.13, respectively. Our results suggest that wavelet analysis is effective as a real-time monitor and that it is possible to distinguish larger volumes of air emboli based on previous injections of small volumes of air.
The real-time wavelet analysis of the heart sound detected by precordial Doppler ultrasound may be useful in estimating larger volumes of air emboli based on previous injections of small volumes of air in anesthetized dogs.</description><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Blood and lymphatic vessels</subject><subject>Cardiology. Vascular system</subject><subject>Dogs</subject><subject>Echocardiography, Doppler</subject><subject>Embolism, Air - diagnosis</subject><subject>Jugular Veins</subject><subject>Medical sciences</subject><subject>Miscellaneous</subject><subject>Regression Analysis</subject><issn>0003-2999</issn><issn>1526-7598</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kF1L5TAQhoMo7ln1Jwi5WLzrms82uVx0dRcEbxQvS5pMNZIm3aQVzpV_fXu0noFhmJl3PngQwpT8pEQ3l2RnkuuKaq0IW5JqcUYP0IZKVleN1OoQbZYar5jW-hv6XsrrklKi6mN0rIXUTPANen8ybxBgwiaasC2-4NRjGLoUvMUvYPKES5qjww4msBM43G3xmMGm7LwJ-DqNY4CM5zBlsyrn7OMztilOPs5pLvgN4i4Yn9fVZcA-Ypeeyyk66k0ocLbGE_R48_vh6k91d3_79-rXXWW50lOlpSKgqetqaXtqKSGul-CEk6wholNUMO6IlZQ3riN1Q4hWHIRVHWNECMJP0MXn3jGnfzOUqR18sRCCibD81ja6bmpO9SJUn0KbUykZ-nbMfjB521LS7ti3X-zbPfv2g_0yer7emLsB3H5whb30f6x9U6wJfTbR-rKXMSp4zTn_D4-LjY8</recordid><startdate>19980201</startdate><enddate>19980201</enddate><creator>LUI, P.-W</creator><creator>CHAN, B. C. B</creator><creator>CHAN, F. H. Y</creator><creator>POON, P. W. F</creator><creator>HSIN WANG</creator><creator>LAM, F. K</creator><general>Lippincott</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19980201</creationdate><title>Wavelet analysis of embolic heart sound detected by precordial Doppler ultrasound during continuous venous air embolism in dogs</title><author>LUI, P.-W ; CHAN, B. C. B ; CHAN, F. H. Y ; POON, P. W. F ; HSIN WANG ; LAM, F. K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c389t-9580e91db65cf1c100df5ed4d52704b81423d0c5137db06700983e4c8b2204403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Blood and lymphatic vessels</topic><topic>Cardiology. Vascular system</topic><topic>Dogs</topic><topic>Echocardiography, Doppler</topic><topic>Embolism, Air - diagnosis</topic><topic>Jugular Veins</topic><topic>Medical sciences</topic><topic>Miscellaneous</topic><topic>Regression Analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>LUI, P.-W</creatorcontrib><creatorcontrib>CHAN, B. C. B</creatorcontrib><creatorcontrib>CHAN, F. H. Y</creatorcontrib><creatorcontrib>POON, P. W. F</creatorcontrib><creatorcontrib>HSIN WANG</creatorcontrib><creatorcontrib>LAM, F. K</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Anesthesia and analgesia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>LUI, P.-W</au><au>CHAN, B. C. B</au><au>CHAN, F. H. Y</au><au>POON, P. W. F</au><au>HSIN WANG</au><au>LAM, F. K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Wavelet analysis of embolic heart sound detected by precordial Doppler ultrasound during continuous venous air embolism in dogs</atitle><jtitle>Anesthesia and analgesia</jtitle><addtitle>Anesth Analg</addtitle><date>1998-02-01</date><risdate>1998</risdate><volume>86</volume><issue>2</issue><spage>325</spage><epage>331</epage><pages>325-331</pages><issn>0003-2999</issn><eissn>1526-7598</eissn><coden>AACRAT</coden><abstract>The spectrum of the embolic heart sounds (EHS) detected by precordial Doppler ultrasound has been previously characterized, but only on small volumes of venous air embolism (VAE). We sought to determine whether real-time wavelet analysis is useful in analyzing the signals of EHS and whether the embolic power of the EHS for larger volumes of air is proportionate to the volume of VAE that has been reported for small volumes of VAE. A series of small air boli (0.01, 0.02, 0.05, 0.07, 0.1, 0.15, 0.2, 0.3, 0.4, and 0.8 mL), followed by continuous infusion of larger volumes of air (0.8, 1.6, 2.4, 4.8, and 9.6 mL), was injected into the external jugular vein through a central catheter in seven pentobarbital-anesthetized dogs. We measured the spectrum of the Doppler heart sound (DHS) in a real-time manner by using wavelet analysis at different scales. Wavelet analysis at scale = 1 yielded satisfactory results in distinguishing abnormal EHS from normal DHS with high sensitivity (100%) and good positive predictive value (100%) compared with the conventional method, which requires an anesthesiologist to listen to the audio DHS signals in a real-time manner. There was a linear relationship (y = 1.08x + 7.89, r = 0.75, P < 0.001) between the cumulative embolic power of the EHS and the air volume introduced in the form of either bolus or continuous infusion. The 95% confidence intervals for slope and intercept were 0.89-1.27 and 7.65-8.13, respectively. Our results suggest that wavelet analysis is effective as a real-time monitor and that it is possible to distinguish larger volumes of air emboli based on previous injections of small volumes of air.
The real-time wavelet analysis of the heart sound detected by precordial Doppler ultrasound may be useful in estimating larger volumes of air emboli based on previous injections of small volumes of air in anesthetized dogs.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott</pub><pmid>9459243</pmid><doi>10.1097/00000539-199802000-00021</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2999 |
ispartof | Anesthesia and analgesia, 1998-02, Vol.86 (2), p.325-331 |
issn | 0003-2999 1526-7598 |
language | eng |
recordid | cdi_proquest_miscellaneous_79676319 |
source | MEDLINE; Journals@Ovid LWW Legacy Archive; Journals@Ovid Complete; EZB-FREE-00999 freely available EZB journals |
subjects | Animals Biological and medical sciences Blood and lymphatic vessels Cardiology. Vascular system Dogs Echocardiography, Doppler Embolism, Air - diagnosis Jugular Veins Medical sciences Miscellaneous Regression Analysis |
title | Wavelet analysis of embolic heart sound detected by precordial Doppler ultrasound during continuous venous air embolism in dogs |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T10%3A30%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Wavelet%20analysis%20of%20embolic%20heart%20sound%20detected%20by%20precordial%20Doppler%20ultrasound%20during%20continuous%20venous%20air%20embolism%20in%20dogs&rft.jtitle=Anesthesia%20and%20analgesia&rft.au=LUI,%20P.-W&rft.date=1998-02-01&rft.volume=86&rft.issue=2&rft.spage=325&rft.epage=331&rft.pages=325-331&rft.issn=0003-2999&rft.eissn=1526-7598&rft.coden=AACRAT&rft_id=info:doi/10.1097/00000539-199802000-00021&rft_dat=%3Cproquest_cross%3E79676319%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79676319&rft_id=info:pmid/9459243&rfr_iscdi=true |