Brain tissue response to Holmium:YAG laser irradiation

To evaluate the usefulness of pulsed infrared solid-state Holmium:Yttrium-Aluminum-Garnet (Ho:YAG) laser in neurosurgery, acute responses of brain tissue to Ho:YAG irradiation and to investigate the healing processes in rats and rabbits. Animals were divided into groups according to different surviv...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chinese medical journal 1998-11, Vol.111 (11), p.982-987
Hauptverfasser: Guo, J, Freidberg, S R, Thomas, C B, Pankratov, M M, Even, M, Shapshay, S M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 987
container_issue 11
container_start_page 982
container_title Chinese medical journal
container_volume 111
creator Guo, J
Freidberg, S R
Thomas, C B
Pankratov, M M
Even, M
Shapshay, S M
description To evaluate the usefulness of pulsed infrared solid-state Holmium:Yttrium-Aluminum-Garnet (Ho:YAG) laser in neurosurgery, acute responses of brain tissue to Ho:YAG irradiation and to investigate the healing processes in rats and rabbits. Animals were divided into groups according to different survival time and laser irradiation mode. Craniotomy was made and laser energy was delivered to the brain surface by two irradiation modes: 1) contact mode with the fiber in contact with the brain surface; and 2) non-contact mode with the fiber tip 5 mm above the brain surface. Gross observations were made and histological changes were studied. Acute responses were studied on rats' brain. The contact mode produced a crater lined with less than 1 mm thick thermally coagulated layer of brain tissue. The non-contact mode effectively vaporized the brain tissue even with water irrigation. Good homeostatic effect was achieved. The shock waves generated by the pulsed delivery of laser energy, however, impacted on the brain resulting in debris spreading and brain vibration. The healing processes were studied on rabbits' brain one day to six weeks after irradiation. The lesions produced by the contact mode were narrow and sharply defined. With the non-contact mode, the thickness of the coagulated layer at the bottom of the crater varied between 0.8 and 1.1 mm. Ho:YAG laser should be a clinically useful tool in neurosurgery because of its good ablation effect, shallow penetration and convenient optic fiber transmission system. Meanwhile, a continuously waved Ho:YAG laser is desired to reduce the shock wave impact.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_79629526</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79629526</sourcerecordid><originalsourceid>FETCH-LOGICAL-p207t-8fc21b0d1c7046e5289e1c26d3cd7f77cc7306fd07e22782cab9ca0a239b0203</originalsourceid><addsrcrecordid>eNo1j7FOwzAUAD2AaCn8AvLEFsl-JnbMVipoK1Vi6cIUOfaLZBTHwS8Z-HuQKNMtp5Puiq2F0rrS1toVuyX6FALq2ugbtpJSNhZArZl-KS6OfI5EC_KCNOWRkM-ZH_KQ4pKeP7Z7PjjCwmMpLkQ3xzzeseveDYT3F27Y-e31vDtUp_f9cbc9VRMIM1dN70F2IkhvxJPGGhqL0oMOygfTG-O9UUL3QRgEMA1411nvhANlOwFCbdjjX3Yq-WtBmtsUyeMwuBHzQq2xGmwN-ld8uIhLlzC0U4nJle_2f1T9AIfiTXk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79629526</pqid></control><display><type>article</type><title>Brain tissue response to Holmium:YAG laser irradiation</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Guo, J ; Freidberg, S R ; Thomas, C B ; Pankratov, M M ; Even, M ; Shapshay, S M</creator><creatorcontrib>Guo, J ; Freidberg, S R ; Thomas, C B ; Pankratov, M M ; Even, M ; Shapshay, S M</creatorcontrib><description>To evaluate the usefulness of pulsed infrared solid-state Holmium:Yttrium-Aluminum-Garnet (Ho:YAG) laser in neurosurgery, acute responses of brain tissue to Ho:YAG irradiation and to investigate the healing processes in rats and rabbits. Animals were divided into groups according to different survival time and laser irradiation mode. Craniotomy was made and laser energy was delivered to the brain surface by two irradiation modes: 1) contact mode with the fiber in contact with the brain surface; and 2) non-contact mode with the fiber tip 5 mm above the brain surface. Gross observations were made and histological changes were studied. Acute responses were studied on rats' brain. The contact mode produced a crater lined with less than 1 mm thick thermally coagulated layer of brain tissue. The non-contact mode effectively vaporized the brain tissue even with water irrigation. Good homeostatic effect was achieved. The shock waves generated by the pulsed delivery of laser energy, however, impacted on the brain resulting in debris spreading and brain vibration. The healing processes were studied on rabbits' brain one day to six weeks after irradiation. The lesions produced by the contact mode were narrow and sharply defined. With the non-contact mode, the thickness of the coagulated layer at the bottom of the crater varied between 0.8 and 1.1 mm. Ho:YAG laser should be a clinically useful tool in neurosurgery because of its good ablation effect, shallow penetration and convenient optic fiber transmission system. Meanwhile, a continuously waved Ho:YAG laser is desired to reduce the shock wave impact.</description><identifier>ISSN: 0366-6999</identifier><identifier>PMID: 11189223</identifier><language>eng</language><publisher>China</publisher><subject>Animals ; Brain - pathology ; Brain - radiation effects ; Brain - surgery ; Female ; Holmium ; Laser Therapy ; Neurosurgical Procedures ; Rabbits ; Rats ; Rats, Sprague-Dawley</subject><ispartof>Chinese medical journal, 1998-11, Vol.111 (11), p.982-987</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11189223$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Guo, J</creatorcontrib><creatorcontrib>Freidberg, S R</creatorcontrib><creatorcontrib>Thomas, C B</creatorcontrib><creatorcontrib>Pankratov, M M</creatorcontrib><creatorcontrib>Even, M</creatorcontrib><creatorcontrib>Shapshay, S M</creatorcontrib><title>Brain tissue response to Holmium:YAG laser irradiation</title><title>Chinese medical journal</title><addtitle>Chin Med J (Engl)</addtitle><description>To evaluate the usefulness of pulsed infrared solid-state Holmium:Yttrium-Aluminum-Garnet (Ho:YAG) laser in neurosurgery, acute responses of brain tissue to Ho:YAG irradiation and to investigate the healing processes in rats and rabbits. Animals were divided into groups according to different survival time and laser irradiation mode. Craniotomy was made and laser energy was delivered to the brain surface by two irradiation modes: 1) contact mode with the fiber in contact with the brain surface; and 2) non-contact mode with the fiber tip 5 mm above the brain surface. Gross observations were made and histological changes were studied. Acute responses were studied on rats' brain. The contact mode produced a crater lined with less than 1 mm thick thermally coagulated layer of brain tissue. The non-contact mode effectively vaporized the brain tissue even with water irrigation. Good homeostatic effect was achieved. The shock waves generated by the pulsed delivery of laser energy, however, impacted on the brain resulting in debris spreading and brain vibration. The healing processes were studied on rabbits' brain one day to six weeks after irradiation. The lesions produced by the contact mode were narrow and sharply defined. With the non-contact mode, the thickness of the coagulated layer at the bottom of the crater varied between 0.8 and 1.1 mm. Ho:YAG laser should be a clinically useful tool in neurosurgery because of its good ablation effect, shallow penetration and convenient optic fiber transmission system. Meanwhile, a continuously waved Ho:YAG laser is desired to reduce the shock wave impact.</description><subject>Animals</subject><subject>Brain - pathology</subject><subject>Brain - radiation effects</subject><subject>Brain - surgery</subject><subject>Female</subject><subject>Holmium</subject><subject>Laser Therapy</subject><subject>Neurosurgical Procedures</subject><subject>Rabbits</subject><subject>Rats</subject><subject>Rats, Sprague-Dawley</subject><issn>0366-6999</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1j7FOwzAUAD2AaCn8AvLEFsl-JnbMVipoK1Vi6cIUOfaLZBTHwS8Z-HuQKNMtp5Puiq2F0rrS1toVuyX6FALq2ugbtpJSNhZArZl-KS6OfI5EC_KCNOWRkM-ZH_KQ4pKeP7Z7PjjCwmMpLkQ3xzzeseveDYT3F27Y-e31vDtUp_f9cbc9VRMIM1dN70F2IkhvxJPGGhqL0oMOygfTG-O9UUL3QRgEMA1411nvhANlOwFCbdjjX3Yq-WtBmtsUyeMwuBHzQq2xGmwN-ld8uIhLlzC0U4nJle_2f1T9AIfiTXk</recordid><startdate>19981101</startdate><enddate>19981101</enddate><creator>Guo, J</creator><creator>Freidberg, S R</creator><creator>Thomas, C B</creator><creator>Pankratov, M M</creator><creator>Even, M</creator><creator>Shapshay, S M</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>19981101</creationdate><title>Brain tissue response to Holmium:YAG laser irradiation</title><author>Guo, J ; Freidberg, S R ; Thomas, C B ; Pankratov, M M ; Even, M ; Shapshay, S M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p207t-8fc21b0d1c7046e5289e1c26d3cd7f77cc7306fd07e22782cab9ca0a239b0203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Animals</topic><topic>Brain - pathology</topic><topic>Brain - radiation effects</topic><topic>Brain - surgery</topic><topic>Female</topic><topic>Holmium</topic><topic>Laser Therapy</topic><topic>Neurosurgical Procedures</topic><topic>Rabbits</topic><topic>Rats</topic><topic>Rats, Sprague-Dawley</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Guo, J</creatorcontrib><creatorcontrib>Freidberg, S R</creatorcontrib><creatorcontrib>Thomas, C B</creatorcontrib><creatorcontrib>Pankratov, M M</creatorcontrib><creatorcontrib>Even, M</creatorcontrib><creatorcontrib>Shapshay, S M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Chinese medical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Guo, J</au><au>Freidberg, S R</au><au>Thomas, C B</au><au>Pankratov, M M</au><au>Even, M</au><au>Shapshay, S M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Brain tissue response to Holmium:YAG laser irradiation</atitle><jtitle>Chinese medical journal</jtitle><addtitle>Chin Med J (Engl)</addtitle><date>1998-11-01</date><risdate>1998</risdate><volume>111</volume><issue>11</issue><spage>982</spage><epage>987</epage><pages>982-987</pages><issn>0366-6999</issn><abstract>To evaluate the usefulness of pulsed infrared solid-state Holmium:Yttrium-Aluminum-Garnet (Ho:YAG) laser in neurosurgery, acute responses of brain tissue to Ho:YAG irradiation and to investigate the healing processes in rats and rabbits. Animals were divided into groups according to different survival time and laser irradiation mode. Craniotomy was made and laser energy was delivered to the brain surface by two irradiation modes: 1) contact mode with the fiber in contact with the brain surface; and 2) non-contact mode with the fiber tip 5 mm above the brain surface. Gross observations were made and histological changes were studied. Acute responses were studied on rats' brain. The contact mode produced a crater lined with less than 1 mm thick thermally coagulated layer of brain tissue. The non-contact mode effectively vaporized the brain tissue even with water irrigation. Good homeostatic effect was achieved. The shock waves generated by the pulsed delivery of laser energy, however, impacted on the brain resulting in debris spreading and brain vibration. The healing processes were studied on rabbits' brain one day to six weeks after irradiation. The lesions produced by the contact mode were narrow and sharply defined. With the non-contact mode, the thickness of the coagulated layer at the bottom of the crater varied between 0.8 and 1.1 mm. Ho:YAG laser should be a clinically useful tool in neurosurgery because of its good ablation effect, shallow penetration and convenient optic fiber transmission system. Meanwhile, a continuously waved Ho:YAG laser is desired to reduce the shock wave impact.</abstract><cop>China</cop><pmid>11189223</pmid><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0366-6999
ispartof Chinese medical journal, 1998-11, Vol.111 (11), p.982-987
issn 0366-6999
language eng
recordid cdi_proquest_miscellaneous_79629526
source MEDLINE; Alma/SFX Local Collection
subjects Animals
Brain - pathology
Brain - radiation effects
Brain - surgery
Female
Holmium
Laser Therapy
Neurosurgical Procedures
Rabbits
Rats
Rats, Sprague-Dawley
title Brain tissue response to Holmium:YAG laser irradiation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T21%3A26%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Brain%20tissue%20response%20to%20Holmium:YAG%20laser%20irradiation&rft.jtitle=Chinese%20medical%20journal&rft.au=Guo,%20J&rft.date=1998-11-01&rft.volume=111&rft.issue=11&rft.spage=982&rft.epage=987&rft.pages=982-987&rft.issn=0366-6999&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E79629526%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79629526&rft_id=info:pmid/11189223&rfr_iscdi=true