Colour penile Doppler ultrasonography with intraurethral prostaglandin-E2: preliminary results

Intraurethral instillation was used in place of intracavernosal injection of vasoactive agents for the colour Doppler investigation of patients with erectile dysfunction. A total of 19 patients were enrolled in this study. Colour penile Doppler ultrasonography was done with intracavernosal injection...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International urology and nephrology 1997, Vol.29 (6), p.667-671
Hauptverfasser: Başar, M, Başar, H, Aydoğanli, L, Alkan, K, Gümüş, O, Akalin, Z
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 671
container_issue 6
container_start_page 667
container_title International urology and nephrology
container_volume 29
creator Başar, M
Başar, H
Aydoğanli, L
Alkan, K
Gümüş, O
Akalin, Z
description Intraurethral instillation was used in place of intracavernosal injection of vasoactive agents for the colour Doppler investigation of patients with erectile dysfunction. A total of 19 patients were enrolled in this study. Colour penile Doppler ultrasonography was done with intracavernosal injection of papaverine-HCl 60 mg and intraurethral instillation of prostaglandin-E2 0.5 mg. Arterial diameter, peak systolic velocity and end diastolic velocity were measured before and after papaverine injection and prostaglandin-E2 instillation. Colour penile Doppler parameters increased statistically significantly after papaverine injection and prostaglandin-E2 instillation (p < 0.01). But we did not observe differences between the results after papaverine-HCl and prostaglandin-E2. We believe that prostaglandin-E2 may be used with colour Doppler ultrasonography in the evaluation of patients with erectile dysfunction.
doi_str_mv 10.1007/BF02552184
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79559939</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79559939</sourcerecordid><originalsourceid>FETCH-LOGICAL-c197t-aa11214bdab2dd1abde746fd503df836c882dd51f1e0173e0df1f4aecd908a703</originalsourceid><addsrcrecordid>eNpFkMFLwzAYxYMoc04v3oWePAjV72uapvWm06kw8KJXS9p83SJZW5MW2X9vZENPDx4_Hj8eY-cI1wggb-4XkAiRYJ4esCkKyeNE5OkhmwIHjDFL-DE78f4TAIocYMImRSolz8SUfcw7240u6qk1lqKHru8tuWi0g1O-a7uVU_16G32bYR2ZNpSjo2HtlI161_lBraxqtWnjx-Q2NGTNxrTKbSNHPmz4U3bUKOvpbJ8z9r54fJs_x8vXp5f53TKusZBDrBRigmmlVZVojarSJNOs0QK4bnKe1XkeeoENEqDkBLrBJlVU6wJyJYHP2OVuN1h9jeSHcmN8TTbYUTf6UhZCFAUvAni1A-ug7x01Ze_MJhiXCOXvmeX_mQG-2K-O1Yb0H7p_j_8AnZpxlQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79559939</pqid></control><display><type>article</type><title>Colour penile Doppler ultrasonography with intraurethral prostaglandin-E2: preliminary results</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Başar, M ; Başar, H ; Aydoğanli, L ; Alkan, K ; Gümüş, O ; Akalin, Z</creator><creatorcontrib>Başar, M ; Başar, H ; Aydoğanli, L ; Alkan, K ; Gümüş, O ; Akalin, Z</creatorcontrib><description>Intraurethral instillation was used in place of intracavernosal injection of vasoactive agents for the colour Doppler investigation of patients with erectile dysfunction. A total of 19 patients were enrolled in this study. Colour penile Doppler ultrasonography was done with intracavernosal injection of papaverine-HCl 60 mg and intraurethral instillation of prostaglandin-E2 0.5 mg. Arterial diameter, peak systolic velocity and end diastolic velocity were measured before and after papaverine injection and prostaglandin-E2 instillation. Colour penile Doppler parameters increased statistically significantly after papaverine injection and prostaglandin-E2 instillation (p &lt; 0.01). But we did not observe differences between the results after papaverine-HCl and prostaglandin-E2. We believe that prostaglandin-E2 may be used with colour Doppler ultrasonography in the evaluation of patients with erectile dysfunction.</description><identifier>ISSN: 0301-1623</identifier><identifier>EISSN: 1573-2584</identifier><identifier>DOI: 10.1007/BF02552184</identifier><identifier>PMID: 9477365</identifier><language>eng</language><publisher>Netherlands</publisher><subject>Adult ; Dinoprostone ; Erectile Dysfunction - diagnostic imaging ; Erectile Dysfunction - physiopathology ; Hemodynamics ; Humans ; Instillation, Drug ; Male ; Middle Aged ; Oxytocics ; Papaverine ; Penis - diagnostic imaging ; Ultrasonography, Doppler, Color ; Vasodilator Agents</subject><ispartof>International urology and nephrology, 1997, Vol.29 (6), p.667-671</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c197t-aa11214bdab2dd1abde746fd503df836c882dd51f1e0173e0df1f4aecd908a703</citedby><cites>FETCH-LOGICAL-c197t-aa11214bdab2dd1abde746fd503df836c882dd51f1e0173e0df1f4aecd908a703</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9477365$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Başar, M</creatorcontrib><creatorcontrib>Başar, H</creatorcontrib><creatorcontrib>Aydoğanli, L</creatorcontrib><creatorcontrib>Alkan, K</creatorcontrib><creatorcontrib>Gümüş, O</creatorcontrib><creatorcontrib>Akalin, Z</creatorcontrib><title>Colour penile Doppler ultrasonography with intraurethral prostaglandin-E2: preliminary results</title><title>International urology and nephrology</title><addtitle>Int Urol Nephrol</addtitle><description>Intraurethral instillation was used in place of intracavernosal injection of vasoactive agents for the colour Doppler investigation of patients with erectile dysfunction. A total of 19 patients were enrolled in this study. Colour penile Doppler ultrasonography was done with intracavernosal injection of papaverine-HCl 60 mg and intraurethral instillation of prostaglandin-E2 0.5 mg. Arterial diameter, peak systolic velocity and end diastolic velocity were measured before and after papaverine injection and prostaglandin-E2 instillation. Colour penile Doppler parameters increased statistically significantly after papaverine injection and prostaglandin-E2 instillation (p &lt; 0.01). But we did not observe differences between the results after papaverine-HCl and prostaglandin-E2. We believe that prostaglandin-E2 may be used with colour Doppler ultrasonography in the evaluation of patients with erectile dysfunction.</description><subject>Adult</subject><subject>Dinoprostone</subject><subject>Erectile Dysfunction - diagnostic imaging</subject><subject>Erectile Dysfunction - physiopathology</subject><subject>Hemodynamics</subject><subject>Humans</subject><subject>Instillation, Drug</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Oxytocics</subject><subject>Papaverine</subject><subject>Penis - diagnostic imaging</subject><subject>Ultrasonography, Doppler, Color</subject><subject>Vasodilator Agents</subject><issn>0301-1623</issn><issn>1573-2584</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkMFLwzAYxYMoc04v3oWePAjV72uapvWm06kw8KJXS9p83SJZW5MW2X9vZENPDx4_Hj8eY-cI1wggb-4XkAiRYJ4esCkKyeNE5OkhmwIHjDFL-DE78f4TAIocYMImRSolz8SUfcw7240u6qk1lqKHru8tuWi0g1O-a7uVU_16G32bYR2ZNpSjo2HtlI161_lBraxqtWnjx-Q2NGTNxrTKbSNHPmz4U3bUKOvpbJ8z9r54fJs_x8vXp5f53TKusZBDrBRigmmlVZVojarSJNOs0QK4bnKe1XkeeoENEqDkBLrBJlVU6wJyJYHP2OVuN1h9jeSHcmN8TTbYUTf6UhZCFAUvAni1A-ug7x01Ze_MJhiXCOXvmeX_mQG-2K-O1Yb0H7p_j_8AnZpxlQ</recordid><startdate>1997</startdate><enddate>1997</enddate><creator>Başar, M</creator><creator>Başar, H</creator><creator>Aydoğanli, L</creator><creator>Alkan, K</creator><creator>Gümüş, O</creator><creator>Akalin, Z</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1997</creationdate><title>Colour penile Doppler ultrasonography with intraurethral prostaglandin-E2: preliminary results</title><author>Başar, M ; Başar, H ; Aydoğanli, L ; Alkan, K ; Gümüş, O ; Akalin, Z</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c197t-aa11214bdab2dd1abde746fd503df836c882dd51f1e0173e0df1f4aecd908a703</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Adult</topic><topic>Dinoprostone</topic><topic>Erectile Dysfunction - diagnostic imaging</topic><topic>Erectile Dysfunction - physiopathology</topic><topic>Hemodynamics</topic><topic>Humans</topic><topic>Instillation, Drug</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Oxytocics</topic><topic>Papaverine</topic><topic>Penis - diagnostic imaging</topic><topic>Ultrasonography, Doppler, Color</topic><topic>Vasodilator Agents</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Başar, M</creatorcontrib><creatorcontrib>Başar, H</creatorcontrib><creatorcontrib>Aydoğanli, L</creatorcontrib><creatorcontrib>Alkan, K</creatorcontrib><creatorcontrib>Gümüş, O</creatorcontrib><creatorcontrib>Akalin, Z</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International urology and nephrology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Başar, M</au><au>Başar, H</au><au>Aydoğanli, L</au><au>Alkan, K</au><au>Gümüş, O</au><au>Akalin, Z</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Colour penile Doppler ultrasonography with intraurethral prostaglandin-E2: preliminary results</atitle><jtitle>International urology and nephrology</jtitle><addtitle>Int Urol Nephrol</addtitle><date>1997</date><risdate>1997</risdate><volume>29</volume><issue>6</issue><spage>667</spage><epage>671</epage><pages>667-671</pages><issn>0301-1623</issn><eissn>1573-2584</eissn><abstract>Intraurethral instillation was used in place of intracavernosal injection of vasoactive agents for the colour Doppler investigation of patients with erectile dysfunction. A total of 19 patients were enrolled in this study. Colour penile Doppler ultrasonography was done with intracavernosal injection of papaverine-HCl 60 mg and intraurethral instillation of prostaglandin-E2 0.5 mg. Arterial diameter, peak systolic velocity and end diastolic velocity were measured before and after papaverine injection and prostaglandin-E2 instillation. Colour penile Doppler parameters increased statistically significantly after papaverine injection and prostaglandin-E2 instillation (p &lt; 0.01). But we did not observe differences between the results after papaverine-HCl and prostaglandin-E2. We believe that prostaglandin-E2 may be used with colour Doppler ultrasonography in the evaluation of patients with erectile dysfunction.</abstract><cop>Netherlands</cop><pmid>9477365</pmid><doi>10.1007/BF02552184</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0301-1623
ispartof International urology and nephrology, 1997, Vol.29 (6), p.667-671
issn 0301-1623
1573-2584
language eng
recordid cdi_proquest_miscellaneous_79559939
source MEDLINE; SpringerLink Journals - AutoHoldings
subjects Adult
Dinoprostone
Erectile Dysfunction - diagnostic imaging
Erectile Dysfunction - physiopathology
Hemodynamics
Humans
Instillation, Drug
Male
Middle Aged
Oxytocics
Papaverine
Penis - diagnostic imaging
Ultrasonography, Doppler, Color
Vasodilator Agents
title Colour penile Doppler ultrasonography with intraurethral prostaglandin-E2: preliminary results
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T06%3A46%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Colour%20penile%20Doppler%20ultrasonography%20with%20intraurethral%20prostaglandin-E2:%20preliminary%20results&rft.jtitle=International%20urology%20and%20nephrology&rft.au=Ba%C5%9Far,%20M&rft.date=1997&rft.volume=29&rft.issue=6&rft.spage=667&rft.epage=671&rft.pages=667-671&rft.issn=0301-1623&rft.eissn=1573-2584&rft_id=info:doi/10.1007/BF02552184&rft_dat=%3Cproquest_cross%3E79559939%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79559939&rft_id=info:pmid/9477365&rfr_iscdi=true