Sphincter of Oddi manometry in healthy volunteers
In this study we describe in detail the characteristics of sphincter of Oddi motor function in a large group of healthy subjects. Studies were obtained in 50 healthy volunteers. The findings showed a sphincter of Oddi segment that had a basal pressure of 14.8 +/- 6.3 mm Hg (X +/- SD). Phasic contrac...
Gespeichert in:
Veröffentlicht in: | Digestive diseases and sciences 1990, Vol.35 (1), p.38-46 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 46 |
---|---|
container_issue | 1 |
container_start_page | 38 |
container_title | Digestive diseases and sciences |
container_volume | 35 |
creator | GUELRUD, M MENDOZA, S ROSSITER, G VILLEGAS, M. I |
description | In this study we describe in detail the characteristics of sphincter of Oddi motor function in a large group of healthy subjects. Studies were obtained in 50 healthy volunteers. The findings showed a sphincter of Oddi segment that had a basal pressure of 14.8 +/- 6.3 mm Hg (X +/- SD). Phasic contractions were superimposed on the basal pressure. They had an amplitude of 119.7 +/- 32 mm Hg, a duration of 4.7 +/- 1 sec, and a frequency of 5.7 +/- 1.2 contractions/min. In 40 subjects the propagation sequence of phasic contractions could be evaluated and were simultaneous in 53%, antegrade in 35%, and retrograde in 11% of the waves. In 20 subjects, pressure measurements done at the common bile duct sphincter waves. In 20 subjects, pressure measurements done at the common bile duct sphincter were similar to those obtained at the pancreatic duct sphincter. In 10 subjects, pressure values obtained at the common bile duct sphincter within a week were similar. Our study should help to establish standards for normal manometric values of the sphincter of Oddi and emphasizes the importance of having a healthy volunteer group from which to obtain the normal values of sphincter of Oddi motor function. |
doi_str_mv | 10.1007/bf01537220 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79531138</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79531138</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-9ab017f9deceed22de05585e7ac46ca217680acf19fdd4a25e0ceb9d298ae1d83</originalsourceid><addsrcrecordid>eNo9kM9LwzAYhoMoc04v3oUexINQzZcsSXPU4VQY7KCeS5p8YZX-mEkr7L-3Y3Wn94X34T08hFwDfQBK1WPhKQiuGKMnZApC8ZQJmZ2SKQU5dAB5Ti5i_KaUagVyQiaMacE0mxL42G7KxnYYktYna-fKpDZNW2MXdknZJBs0VbfZJb9t1TcdYoiX5MybKuLVmDPytXz5XLylq_Xr--JplVquVJdqU1BQXju0iI4xh1SITKAydi6tYaBkRo31oL1zc8MEUouFdkxnBsFlfEbuDr_b0P70GLu8LqPFqjINtn3MlRYcgO_B-wNoQxtjQJ9vQ1mbsMuB5ns_-fPy388A34yvfVGjO6KjkGG_HXcTral8MI0t4xGTmvJBIv8D6OFshQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79531138</pqid></control><display><type>article</type><title>Sphincter of Oddi manometry in healthy volunteers</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>GUELRUD, M ; MENDOZA, S ; ROSSITER, G ; VILLEGAS, M. I</creator><creatorcontrib>GUELRUD, M ; MENDOZA, S ; ROSSITER, G ; VILLEGAS, M. I</creatorcontrib><description>In this study we describe in detail the characteristics of sphincter of Oddi motor function in a large group of healthy subjects. Studies were obtained in 50 healthy volunteers. The findings showed a sphincter of Oddi segment that had a basal pressure of 14.8 +/- 6.3 mm Hg (X +/- SD). Phasic contractions were superimposed on the basal pressure. They had an amplitude of 119.7 +/- 32 mm Hg, a duration of 4.7 +/- 1 sec, and a frequency of 5.7 +/- 1.2 contractions/min. In 40 subjects the propagation sequence of phasic contractions could be evaluated and were simultaneous in 53%, antegrade in 35%, and retrograde in 11% of the waves. In 20 subjects, pressure measurements done at the common bile duct sphincter waves. In 20 subjects, pressure measurements done at the common bile duct sphincter were similar to those obtained at the pancreatic duct sphincter. In 10 subjects, pressure values obtained at the common bile duct sphincter within a week were similar. Our study should help to establish standards for normal manometric values of the sphincter of Oddi and emphasizes the importance of having a healthy volunteer group from which to obtain the normal values of sphincter of Oddi motor function.</description><identifier>ISSN: 0163-2116</identifier><identifier>EISSN: 1573-2568</identifier><identifier>DOI: 10.1007/bf01537220</identifier><identifier>PMID: 2295292</identifier><identifier>CODEN: DDSCDJ</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Adult ; Ampulla of Vater - physiology ; Biological and medical sciences ; Cholangiopancreatography, Endoscopic Retrograde ; Female ; Fundamental and applied biological sciences. Psychology ; General aspects ; Humans ; Male ; Manometry ; Middle Aged ; Muscle Contraction - physiology ; Peristalsis ; Pressure ; Reference Values ; Sphincter of Oddi - physiology ; Vertebrates: digestive system</subject><ispartof>Digestive diseases and sciences, 1990, Vol.35 (1), p.38-46</ispartof><rights>1990 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-9ab017f9deceed22de05585e7ac46ca217680acf19fdd4a25e0ceb9d298ae1d83</citedby><cites>FETCH-LOGICAL-c377t-9ab017f9deceed22de05585e7ac46ca217680acf19fdd4a25e0ceb9d298ae1d83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4010,27900,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=6903009$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2295292$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>GUELRUD, M</creatorcontrib><creatorcontrib>MENDOZA, S</creatorcontrib><creatorcontrib>ROSSITER, G</creatorcontrib><creatorcontrib>VILLEGAS, M. I</creatorcontrib><title>Sphincter of Oddi manometry in healthy volunteers</title><title>Digestive diseases and sciences</title><addtitle>Dig Dis Sci</addtitle><description>In this study we describe in detail the characteristics of sphincter of Oddi motor function in a large group of healthy subjects. Studies were obtained in 50 healthy volunteers. The findings showed a sphincter of Oddi segment that had a basal pressure of 14.8 +/- 6.3 mm Hg (X +/- SD). Phasic contractions were superimposed on the basal pressure. They had an amplitude of 119.7 +/- 32 mm Hg, a duration of 4.7 +/- 1 sec, and a frequency of 5.7 +/- 1.2 contractions/min. In 40 subjects the propagation sequence of phasic contractions could be evaluated and were simultaneous in 53%, antegrade in 35%, and retrograde in 11% of the waves. In 20 subjects, pressure measurements done at the common bile duct sphincter waves. In 20 subjects, pressure measurements done at the common bile duct sphincter were similar to those obtained at the pancreatic duct sphincter. In 10 subjects, pressure values obtained at the common bile duct sphincter within a week were similar. Our study should help to establish standards for normal manometric values of the sphincter of Oddi and emphasizes the importance of having a healthy volunteer group from which to obtain the normal values of sphincter of Oddi motor function.</description><subject>Adult</subject><subject>Ampulla of Vater - physiology</subject><subject>Biological and medical sciences</subject><subject>Cholangiopancreatography, Endoscopic Retrograde</subject><subject>Female</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General aspects</subject><subject>Humans</subject><subject>Male</subject><subject>Manometry</subject><subject>Middle Aged</subject><subject>Muscle Contraction - physiology</subject><subject>Peristalsis</subject><subject>Pressure</subject><subject>Reference Values</subject><subject>Sphincter of Oddi - physiology</subject><subject>Vertebrates: digestive system</subject><issn>0163-2116</issn><issn>1573-2568</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kM9LwzAYhoMoc04v3oUexINQzZcsSXPU4VQY7KCeS5p8YZX-mEkr7L-3Y3Wn94X34T08hFwDfQBK1WPhKQiuGKMnZApC8ZQJmZ2SKQU5dAB5Ti5i_KaUagVyQiaMacE0mxL42G7KxnYYktYna-fKpDZNW2MXdknZJBs0VbfZJb9t1TcdYoiX5MybKuLVmDPytXz5XLylq_Xr--JplVquVJdqU1BQXju0iI4xh1SITKAydi6tYaBkRo31oL1zc8MEUouFdkxnBsFlfEbuDr_b0P70GLu8LqPFqjINtn3MlRYcgO_B-wNoQxtjQJ9vQ1mbsMuB5ns_-fPy388A34yvfVGjO6KjkGG_HXcTral8MI0t4xGTmvJBIv8D6OFshQ</recordid><startdate>1990</startdate><enddate>1990</enddate><creator>GUELRUD, M</creator><creator>MENDOZA, S</creator><creator>ROSSITER, G</creator><creator>VILLEGAS, M. I</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1990</creationdate><title>Sphincter of Oddi manometry in healthy volunteers</title><author>GUELRUD, M ; MENDOZA, S ; ROSSITER, G ; VILLEGAS, M. I</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-9ab017f9deceed22de05585e7ac46ca217680acf19fdd4a25e0ceb9d298ae1d83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Adult</topic><topic>Ampulla of Vater - physiology</topic><topic>Biological and medical sciences</topic><topic>Cholangiopancreatography, Endoscopic Retrograde</topic><topic>Female</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General aspects</topic><topic>Humans</topic><topic>Male</topic><topic>Manometry</topic><topic>Middle Aged</topic><topic>Muscle Contraction - physiology</topic><topic>Peristalsis</topic><topic>Pressure</topic><topic>Reference Values</topic><topic>Sphincter of Oddi - physiology</topic><topic>Vertebrates: digestive system</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>GUELRUD, M</creatorcontrib><creatorcontrib>MENDOZA, S</creatorcontrib><creatorcontrib>ROSSITER, G</creatorcontrib><creatorcontrib>VILLEGAS, M. I</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Digestive diseases and sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>GUELRUD, M</au><au>MENDOZA, S</au><au>ROSSITER, G</au><au>VILLEGAS, M. I</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sphincter of Oddi manometry in healthy volunteers</atitle><jtitle>Digestive diseases and sciences</jtitle><addtitle>Dig Dis Sci</addtitle><date>1990</date><risdate>1990</risdate><volume>35</volume><issue>1</issue><spage>38</spage><epage>46</epage><pages>38-46</pages><issn>0163-2116</issn><eissn>1573-2568</eissn><coden>DDSCDJ</coden><abstract>In this study we describe in detail the characteristics of sphincter of Oddi motor function in a large group of healthy subjects. Studies were obtained in 50 healthy volunteers. The findings showed a sphincter of Oddi segment that had a basal pressure of 14.8 +/- 6.3 mm Hg (X +/- SD). Phasic contractions were superimposed on the basal pressure. They had an amplitude of 119.7 +/- 32 mm Hg, a duration of 4.7 +/- 1 sec, and a frequency of 5.7 +/- 1.2 contractions/min. In 40 subjects the propagation sequence of phasic contractions could be evaluated and were simultaneous in 53%, antegrade in 35%, and retrograde in 11% of the waves. In 20 subjects, pressure measurements done at the common bile duct sphincter waves. In 20 subjects, pressure measurements done at the common bile duct sphincter were similar to those obtained at the pancreatic duct sphincter. In 10 subjects, pressure values obtained at the common bile duct sphincter within a week were similar. Our study should help to establish standards for normal manometric values of the sphincter of Oddi and emphasizes the importance of having a healthy volunteer group from which to obtain the normal values of sphincter of Oddi motor function.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>2295292</pmid><doi>10.1007/bf01537220</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0163-2116 |
ispartof | Digestive diseases and sciences, 1990, Vol.35 (1), p.38-46 |
issn | 0163-2116 1573-2568 |
language | eng |
recordid | cdi_proquest_miscellaneous_79531138 |
source | MEDLINE; SpringerLink Journals - AutoHoldings |
subjects | Adult Ampulla of Vater - physiology Biological and medical sciences Cholangiopancreatography, Endoscopic Retrograde Female Fundamental and applied biological sciences. Psychology General aspects Humans Male Manometry Middle Aged Muscle Contraction - physiology Peristalsis Pressure Reference Values Sphincter of Oddi - physiology Vertebrates: digestive system |
title | Sphincter of Oddi manometry in healthy volunteers |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T20%3A15%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sphincter%20of%20Oddi%20manometry%20in%20healthy%20volunteers&rft.jtitle=Digestive%20diseases%20and%20sciences&rft.au=GUELRUD,%20M&rft.date=1990&rft.volume=35&rft.issue=1&rft.spage=38&rft.epage=46&rft.pages=38-46&rft.issn=0163-2116&rft.eissn=1573-2568&rft.coden=DDSCDJ&rft_id=info:doi/10.1007/bf01537220&rft_dat=%3Cproquest_cross%3E79531138%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79531138&rft_id=info:pmid/2295292&rfr_iscdi=true |