A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants

An apparatus was designed for mechanical compression of cultured articular cartilage explants with a cylindrical plain-ended loading head (diameter 2–5 mm) driven by a stepping motor. A load cell under the culture dish was applied for feedback regulation utilizing a microprocessor-based control unit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomechanics 1989, Vol.22 (11), p.1285-1291
Hauptverfasser: Parkkinen, Jyrki J., Lammi, Mikko J., Karjalainen, Seppo, Laakkonen, Jukka, Hyvärinen, Erkki, Tiihonen, Aimo, Helminen, Heikki J., Tammi, Markku
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1291
container_issue 11
container_start_page 1285
container_title Journal of biomechanics
container_volume 22
creator Parkkinen, Jyrki J.
Lammi, Mikko J.
Karjalainen, Seppo
Laakkonen, Jukka
Hyvärinen, Erkki
Tiihonen, Aimo
Helminen, Heikki J.
Tammi, Markku
description An apparatus was designed for mechanical compression of cultured articular cartilage explants with a cylindrical plain-ended loading head (diameter 2–5 mm) driven by a stepping motor. A load cell under the culture dish was applied for feedback regulation utilizing a microprocessor-based control unit. The operating programs allowed either continuous or cyclic loading, the latter with adjustable loading/resting ratio. The improvements in the present design compared with previously described apparatuses for similar purposes include: (1) the accurately controlled compression by a load cell and a rapid feedback circuit; (2) the wide range of selectable stresses (25 kPa–12.5 MPa) with both continuous and cyclic loading modes; (3) the ability to handle cycles as short as 1 s with 15 ms peak loading phase. Using a 4s cycle and 0.5 MPa load for 1.5 h resulted in a significantly enhanced incorporation of radiosulphate in cultured bovine articular cartilage explants, suggesting a stimulation of proteoglycan synthesis. Light and scanning electron microscopic examinations revealed a slight depression and superficial alterations in cartilage structure at the impact site following high pressures. We expect that this apparatus will help in revealing how articular cartilage tissue and chondrocytes respond to external mechanical stimuli.
doi_str_mv 10.1016/0021-9290(89)90232-7
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79475311</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0021929089902327</els_id><sourcerecordid>25272763</sourcerecordid><originalsourceid>FETCH-LOGICAL-c449t-cca2abd449d6f26f698599786dec9bf247e0303807be6e12a3befd897c2537dd3</originalsourceid><addsrcrecordid>eNqFkUuPFSEQhYnRjNfRf6AJC-Nj0cqrodlMMpn4SiZxo2vChcLB0A-BVmfvD5f23tzluKLgfHVS1EHoKSVvKKHyLSGMdppp8mrQrzVhnHXqHtrRQfGO8YHcR7sT8hA9KuU7IUQJpc_QGZOsF5zs0J9LPIK7sVN0NmG7LDbbuhb8K9YbPEaX5yXPDkqZM3bzVPOcEnhcam5vuGkhJsBhU29diq5B47JpcZ7wHLBbU11z67C5xnaxDdzKZL8Bht9LslMtj9GDYFOBJ8fzHH19_-7L1cfu-vOHT1eX150TQtfOOcvs3rfay8BkkHrotVaD9OD0PjChgHDSfq72IIEyy_cQ_KCVYz1X3vNz9OLg2-b-sUKpZozFQWpDwLwWo7RQPae0gS_vBoUkXNBh-K8l65liSvIGigPYVlpKhmCWHEebbw0lZsvTbGGZLSwzaPMvT6Na27Oj_7ofwZ-ajgE2_flRt6UlGLKdXCwnTA6iZ0w37OKAQVvvzwjZFBdhcuBjBleNn-Pdc_wF1DC_Jg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>25272763</pqid></control><display><type>article</type><title>A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Parkkinen, Jyrki J. ; Lammi, Mikko J. ; Karjalainen, Seppo ; Laakkonen, Jukka ; Hyvärinen, Erkki ; Tiihonen, Aimo ; Helminen, Heikki J. ; Tammi, Markku</creator><creatorcontrib>Parkkinen, Jyrki J. ; Lammi, Mikko J. ; Karjalainen, Seppo ; Laakkonen, Jukka ; Hyvärinen, Erkki ; Tiihonen, Aimo ; Helminen, Heikki J. ; Tammi, Markku</creatorcontrib><description>An apparatus was designed for mechanical compression of cultured articular cartilage explants with a cylindrical plain-ended loading head (diameter 2–5 mm) driven by a stepping motor. A load cell under the culture dish was applied for feedback regulation utilizing a microprocessor-based control unit. The operating programs allowed either continuous or cyclic loading, the latter with adjustable loading/resting ratio. The improvements in the present design compared with previously described apparatuses for similar purposes include: (1) the accurately controlled compression by a load cell and a rapid feedback circuit; (2) the wide range of selectable stresses (25 kPa–12.5 MPa) with both continuous and cyclic loading modes; (3) the ability to handle cycles as short as 1 s with 15 ms peak loading phase. Using a 4s cycle and 0.5 MPa load for 1.5 h resulted in a significantly enhanced incorporation of radiosulphate in cultured bovine articular cartilage explants, suggesting a stimulation of proteoglycan synthesis. Light and scanning electron microscopic examinations revealed a slight depression and superficial alterations in cartilage structure at the impact site following high pressures. We expect that this apparatus will help in revealing how articular cartilage tissue and chondrocytes respond to external mechanical stimuli.</description><identifier>ISSN: 0021-9290</identifier><identifier>EISSN: 1873-2380</identifier><identifier>DOI: 10.1016/0021-9290(89)90232-7</identifier><identifier>PMID: 2625430</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Animals ; Biological and medical sciences ; Cartilage, Articular - metabolism ; Cartilage, Articular - physiology ; compression testing ; computer aided analysis ; Culture Techniques ; Equipment and Supplies ; Fundamental and applied biological sciences. Psychology ; Microcomputers ; Skeleton and joints ; Space life sciences ; stress ; Stress, Mechanical ; Vertebrates: osteoarticular system, musculoskeletal system</subject><ispartof>Journal of biomechanics, 1989, Vol.22 (11), p.1285-1291</ispartof><rights>1989</rights><rights>1990 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c449t-cca2abd449d6f26f698599786dec9bf247e0303807be6e12a3befd897c2537dd3</citedby><cites>FETCH-LOGICAL-c449t-cca2abd449d6f26f698599786dec9bf247e0303807be6e12a3befd897c2537dd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0021929089902327$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,4009,27902,27903,27904,65309</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=6845229$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2625430$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Parkkinen, Jyrki J.</creatorcontrib><creatorcontrib>Lammi, Mikko J.</creatorcontrib><creatorcontrib>Karjalainen, Seppo</creatorcontrib><creatorcontrib>Laakkonen, Jukka</creatorcontrib><creatorcontrib>Hyvärinen, Erkki</creatorcontrib><creatorcontrib>Tiihonen, Aimo</creatorcontrib><creatorcontrib>Helminen, Heikki J.</creatorcontrib><creatorcontrib>Tammi, Markku</creatorcontrib><title>A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants</title><title>Journal of biomechanics</title><addtitle>J Biomech</addtitle><description>An apparatus was designed for mechanical compression of cultured articular cartilage explants with a cylindrical plain-ended loading head (diameter 2–5 mm) driven by a stepping motor. A load cell under the culture dish was applied for feedback regulation utilizing a microprocessor-based control unit. The operating programs allowed either continuous or cyclic loading, the latter with adjustable loading/resting ratio. The improvements in the present design compared with previously described apparatuses for similar purposes include: (1) the accurately controlled compression by a load cell and a rapid feedback circuit; (2) the wide range of selectable stresses (25 kPa–12.5 MPa) with both continuous and cyclic loading modes; (3) the ability to handle cycles as short as 1 s with 15 ms peak loading phase. Using a 4s cycle and 0.5 MPa load for 1.5 h resulted in a significantly enhanced incorporation of radiosulphate in cultured bovine articular cartilage explants, suggesting a stimulation of proteoglycan synthesis. Light and scanning electron microscopic examinations revealed a slight depression and superficial alterations in cartilage structure at the impact site following high pressures. We expect that this apparatus will help in revealing how articular cartilage tissue and chondrocytes respond to external mechanical stimuli.</description><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Cartilage, Articular - metabolism</subject><subject>Cartilage, Articular - physiology</subject><subject>compression testing</subject><subject>computer aided analysis</subject><subject>Culture Techniques</subject><subject>Equipment and Supplies</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Microcomputers</subject><subject>Skeleton and joints</subject><subject>Space life sciences</subject><subject>stress</subject><subject>Stress, Mechanical</subject><subject>Vertebrates: osteoarticular system, musculoskeletal system</subject><issn>0021-9290</issn><issn>1873-2380</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkUuPFSEQhYnRjNfRf6AJC-Nj0cqrodlMMpn4SiZxo2vChcLB0A-BVmfvD5f23tzluKLgfHVS1EHoKSVvKKHyLSGMdppp8mrQrzVhnHXqHtrRQfGO8YHcR7sT8hA9KuU7IUQJpc_QGZOsF5zs0J9LPIK7sVN0NmG7LDbbuhb8K9YbPEaX5yXPDkqZM3bzVPOcEnhcam5vuGkhJsBhU29diq5B47JpcZ7wHLBbU11z67C5xnaxDdzKZL8Bht9LslMtj9GDYFOBJ8fzHH19_-7L1cfu-vOHT1eX150TQtfOOcvs3rfay8BkkHrotVaD9OD0PjChgHDSfq72IIEyy_cQ_KCVYz1X3vNz9OLg2-b-sUKpZozFQWpDwLwWo7RQPae0gS_vBoUkXNBh-K8l65liSvIGigPYVlpKhmCWHEebbw0lZsvTbGGZLSwzaPMvT6Na27Oj_7ofwZ-ajgE2_flRt6UlGLKdXCwnTA6iZ0w37OKAQVvvzwjZFBdhcuBjBleNn-Pdc_wF1DC_Jg</recordid><startdate>1989</startdate><enddate>1989</enddate><creator>Parkkinen, Jyrki J.</creator><creator>Lammi, Mikko J.</creator><creator>Karjalainen, Seppo</creator><creator>Laakkonen, Jukka</creator><creator>Hyvärinen, Erkki</creator><creator>Tiihonen, Aimo</creator><creator>Helminen, Heikki J.</creator><creator>Tammi, Markku</creator><general>Elsevier Ltd</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>8FD</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>7TC</scope><scope>7X8</scope></search><sort><creationdate>1989</creationdate><title>A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants</title><author>Parkkinen, Jyrki J. ; Lammi, Mikko J. ; Karjalainen, Seppo ; Laakkonen, Jukka ; Hyvärinen, Erkki ; Tiihonen, Aimo ; Helminen, Heikki J. ; Tammi, Markku</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c449t-cca2abd449d6f26f698599786dec9bf247e0303807be6e12a3befd897c2537dd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Cartilage, Articular - metabolism</topic><topic>Cartilage, Articular - physiology</topic><topic>compression testing</topic><topic>computer aided analysis</topic><topic>Culture Techniques</topic><topic>Equipment and Supplies</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Microcomputers</topic><topic>Skeleton and joints</topic><topic>Space life sciences</topic><topic>stress</topic><topic>Stress, Mechanical</topic><topic>Vertebrates: osteoarticular system, musculoskeletal system</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Parkkinen, Jyrki J.</creatorcontrib><creatorcontrib>Lammi, Mikko J.</creatorcontrib><creatorcontrib>Karjalainen, Seppo</creatorcontrib><creatorcontrib>Laakkonen, Jukka</creatorcontrib><creatorcontrib>Hyvärinen, Erkki</creatorcontrib><creatorcontrib>Tiihonen, Aimo</creatorcontrib><creatorcontrib>Helminen, Heikki J.</creatorcontrib><creatorcontrib>Tammi, Markku</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Mechanical Engineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of biomechanics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Parkkinen, Jyrki J.</au><au>Lammi, Mikko J.</au><au>Karjalainen, Seppo</au><au>Laakkonen, Jukka</au><au>Hyvärinen, Erkki</au><au>Tiihonen, Aimo</au><au>Helminen, Heikki J.</au><au>Tammi, Markku</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants</atitle><jtitle>Journal of biomechanics</jtitle><addtitle>J Biomech</addtitle><date>1989</date><risdate>1989</risdate><volume>22</volume><issue>11</issue><spage>1285</spage><epage>1291</epage><pages>1285-1291</pages><issn>0021-9290</issn><eissn>1873-2380</eissn><abstract>An apparatus was designed for mechanical compression of cultured articular cartilage explants with a cylindrical plain-ended loading head (diameter 2–5 mm) driven by a stepping motor. A load cell under the culture dish was applied for feedback regulation utilizing a microprocessor-based control unit. The operating programs allowed either continuous or cyclic loading, the latter with adjustable loading/resting ratio. The improvements in the present design compared with previously described apparatuses for similar purposes include: (1) the accurately controlled compression by a load cell and a rapid feedback circuit; (2) the wide range of selectable stresses (25 kPa–12.5 MPa) with both continuous and cyclic loading modes; (3) the ability to handle cycles as short as 1 s with 15 ms peak loading phase. Using a 4s cycle and 0.5 MPa load for 1.5 h resulted in a significantly enhanced incorporation of radiosulphate in cultured bovine articular cartilage explants, suggesting a stimulation of proteoglycan synthesis. Light and scanning electron microscopic examinations revealed a slight depression and superficial alterations in cartilage structure at the impact site following high pressures. We expect that this apparatus will help in revealing how articular cartilage tissue and chondrocytes respond to external mechanical stimuli.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><pmid>2625430</pmid><doi>10.1016/0021-9290(89)90232-7</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9290
ispartof Journal of biomechanics, 1989, Vol.22 (11), p.1285-1291
issn 0021-9290
1873-2380
language eng
recordid cdi_proquest_miscellaneous_79475311
source MEDLINE; Elsevier ScienceDirect Journals
subjects Animals
Biological and medical sciences
Cartilage, Articular - metabolism
Cartilage, Articular - physiology
compression testing
computer aided analysis
Culture Techniques
Equipment and Supplies
Fundamental and applied biological sciences. Psychology
Microcomputers
Skeleton and joints
Space life sciences
stress
Stress, Mechanical
Vertebrates: osteoarticular system, musculoskeletal system
title A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T19%3A14%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20mechanical%20apparatus%20with%20microprocessor%20controlled%20stress%20profile%20for%20cyclic%20compression%20of%20cultured%20articular%20cartilage%20explants&rft.jtitle=Journal%20of%20biomechanics&rft.au=Parkkinen,%20Jyrki%20J.&rft.date=1989&rft.volume=22&rft.issue=11&rft.spage=1285&rft.epage=1291&rft.pages=1285-1291&rft.issn=0021-9290&rft.eissn=1873-2380&rft_id=info:doi/10.1016/0021-9290(89)90232-7&rft_dat=%3Cproquest_cross%3E25272763%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=25272763&rft_id=info:pmid/2625430&rft_els_id=0021929089902327&rfr_iscdi=true