Automatic Internal Cardioverter-Defibrillator Patch Erosion Into the Upper Airway Presenting as a Cavitary Lesion
Erosion of an automatic internal cardioverter-defibrillator (AICD) patch into the lingular bronchus occurred 4 years after implantation; the erosion presented as a cavitary mass associated with hemoptysis and weight loss. On bronchoscopy to evaluate for suspected carcinoma, a cavity was entered thro...
Gespeichert in:
Veröffentlicht in: | Chest 1997-10, Vol.112 (4), p.1144-1146 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Erosion of an automatic internal cardioverter-defibrillator (AICD) patch into the lingular bronchus occurred 4 years after implantation; the erosion presented as a cavitary mass associated with hemoptysis and weight loss. On bronchoscopy to evaluate for suspected carcinoma, a cavity was entered through a bronchial defect and the AICD patch clearly identified. The complication was successfully treated with patch removal and fistula closure. |
---|---|