Fit the patient to the prosthesis: an argument against the routine use of custom hip implants

There are selected circumstances in which customizing an implant is a solution to a unique problem. However, there are significant reservations as to the need for the routine use of custom hip implants. In fact, it is possible for a customized implant not to function clinically up to the standards t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical orthopaedics and related research 1989-12, Vol.249 (249), p.56-59
1. Verfasser: CAPELLO, W. N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 59
container_issue 249
container_start_page 56
container_title Clinical orthopaedics and related research
container_volume 249
creator CAPELLO, W. N
description There are selected circumstances in which customizing an implant is a solution to a unique problem. However, there are significant reservations as to the need for the routine use of custom hip implants. In fact, it is possible for a customized implant not to function clinically up to the standards that have already been established by the modern, currently available, off-the-shelf implants.
doi_str_mv 10.1097/00003086-198912000-00008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79335795</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79335795</sourcerecordid><originalsourceid>FETCH-LOGICAL-c315t-4cbf7d63da1f08c32926d4afe96f114699336fdb48a9d75436346c27dead1e9b3</originalsourceid><addsrcrecordid>eNqFUctOwzAQtBColMInIPmAuAXiRxybG6ooIFXiAhIXFDl-tEZ5ETsH_h6HhF7xZb07M7urHQAgSm9QKvLbND6ScpYgwQXCMUvGEj8CS5RhniBE8DFYxpJIBEbvp-DM-89RRDO8AAvMOKUsX4KPjQsw7A3sZHCmif92SvvWx-idv4OygbLfDfUIy510jZ8kfTsE1xg4eANbC9XgQ1vDveugq7tKNsGfgxMrK28u5rgCb5uH1_VTsn15fF7fbxNFUBYSqkqba0a0RDblimCBmabSGsEsQpQJQQizuqRcCp1nlDBCmcK5NlIjI0qyAtdT37j212B8KGrnlaniEqYdfJHHBlkusn-JiI2HISQS-URU8RC-N7boelfL_rtAaTFaUPxZUBws-C3xKL2cZwxlbfRBON884lczLr2Sle1lo5w_0JigVGBKfgB_tI6S</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>16684433</pqid></control><display><type>article</type><title>Fit the patient to the prosthesis: an argument against the routine use of custom hip implants</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>CAPELLO, W. N</creator><creatorcontrib>CAPELLO, W. N</creatorcontrib><description>There are selected circumstances in which customizing an implant is a solution to a unique problem. However, there are significant reservations as to the need for the routine use of custom hip implants. In fact, it is possible for a customized implant not to function clinically up to the standards that have already been established by the modern, currently available, off-the-shelf implants.</description><identifier>ISSN: 0009-921X</identifier><identifier>EISSN: 1528-1132</identifier><identifier>DOI: 10.1097/00003086-198912000-00008</identifier><identifier>PMID: 2684467</identifier><identifier>CODEN: CORTBR</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Biological and medical sciences ; Femur - anatomy &amp; histology ; Hip Prosthesis ; Humans ; Medical sciences ; Orthopedic surgery ; Prosthesis Design ; Surface Properties ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><ispartof>Clinical orthopaedics and related research, 1989-12, Vol.249 (249), p.56-59</ispartof><rights>1990 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=6944924$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2684467$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>CAPELLO, W. N</creatorcontrib><title>Fit the patient to the prosthesis: an argument against the routine use of custom hip implants</title><title>Clinical orthopaedics and related research</title><addtitle>Clin Orthop Relat Res</addtitle><description>There are selected circumstances in which customizing an implant is a solution to a unique problem. However, there are significant reservations as to the need for the routine use of custom hip implants. In fact, it is possible for a customized implant not to function clinically up to the standards that have already been established by the modern, currently available, off-the-shelf implants.</description><subject>Biological and medical sciences</subject><subject>Femur - anatomy &amp; histology</subject><subject>Hip Prosthesis</subject><subject>Humans</subject><subject>Medical sciences</subject><subject>Orthopedic surgery</subject><subject>Prosthesis Design</subject><subject>Surface Properties</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><issn>0009-921X</issn><issn>1528-1132</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFUctOwzAQtBColMInIPmAuAXiRxybG6ooIFXiAhIXFDl-tEZ5ETsH_h6HhF7xZb07M7urHQAgSm9QKvLbND6ScpYgwQXCMUvGEj8CS5RhniBE8DFYxpJIBEbvp-DM-89RRDO8AAvMOKUsX4KPjQsw7A3sZHCmif92SvvWx-idv4OygbLfDfUIy510jZ8kfTsE1xg4eANbC9XgQ1vDveugq7tKNsGfgxMrK28u5rgCb5uH1_VTsn15fF7fbxNFUBYSqkqba0a0RDblimCBmabSGsEsQpQJQQizuqRcCp1nlDBCmcK5NlIjI0qyAtdT37j212B8KGrnlaniEqYdfJHHBlkusn-JiI2HISQS-URU8RC-N7boelfL_rtAaTFaUPxZUBws-C3xKL2cZwxlbfRBON884lczLr2Sle1lo5w_0JigVGBKfgB_tI6S</recordid><startdate>19891201</startdate><enddate>19891201</enddate><creator>CAPELLO, W. N</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QP</scope><scope>7X8</scope></search><sort><creationdate>19891201</creationdate><title>Fit the patient to the prosthesis: an argument against the routine use of custom hip implants</title><author>CAPELLO, W. N</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c315t-4cbf7d63da1f08c32926d4afe96f114699336fdb48a9d75436346c27dead1e9b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>Biological and medical sciences</topic><topic>Femur - anatomy &amp; histology</topic><topic>Hip Prosthesis</topic><topic>Humans</topic><topic>Medical sciences</topic><topic>Orthopedic surgery</topic><topic>Prosthesis Design</topic><topic>Surface Properties</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>CAPELLO, W. N</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Calcium &amp; Calcified Tissue Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical orthopaedics and related research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>CAPELLO, W. N</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fit the patient to the prosthesis: an argument against the routine use of custom hip implants</atitle><jtitle>Clinical orthopaedics and related research</jtitle><addtitle>Clin Orthop Relat Res</addtitle><date>1989-12-01</date><risdate>1989</risdate><volume>249</volume><issue>249</issue><spage>56</spage><epage>59</epage><pages>56-59</pages><issn>0009-921X</issn><eissn>1528-1132</eissn><coden>CORTBR</coden><abstract>There are selected circumstances in which customizing an implant is a solution to a unique problem. However, there are significant reservations as to the need for the routine use of custom hip implants. In fact, it is possible for a customized implant not to function clinically up to the standards that have already been established by the modern, currently available, off-the-shelf implants.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>2684467</pmid><doi>10.1097/00003086-198912000-00008</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0009-921X
ispartof Clinical orthopaedics and related research, 1989-12, Vol.249 (249), p.56-59
issn 0009-921X
1528-1132
language eng
recordid cdi_proquest_miscellaneous_79335795
source MEDLINE; Journals@Ovid Complete
subjects Biological and medical sciences
Femur - anatomy & histology
Hip Prosthesis
Humans
Medical sciences
Orthopedic surgery
Prosthesis Design
Surface Properties
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
title Fit the patient to the prosthesis: an argument against the routine use of custom hip implants
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T08%3A45%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fit%20the%20patient%20to%20the%20prosthesis:%20an%20argument%20against%20the%20routine%20use%20of%20custom%20hip%20implants&rft.jtitle=Clinical%20orthopaedics%20and%20related%20research&rft.au=CAPELLO,%20W.%20N&rft.date=1989-12-01&rft.volume=249&rft.issue=249&rft.spage=56&rft.epage=59&rft.pages=56-59&rft.issn=0009-921X&rft.eissn=1528-1132&rft.coden=CORTBR&rft_id=info:doi/10.1097/00003086-198912000-00008&rft_dat=%3Cproquest_cross%3E79335795%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=16684433&rft_id=info:pmid/2684467&rfr_iscdi=true