Magnum Wire for Percutaneous Coronary Balloon Angioplasty in 800 Total Chronic Occlusions

The experience in consecutive procedures with 800 recanalization attempts of chronic total coronary occlusions using the Magnum wire was analyzed from a prospectively constituted computerized database. The data confirm that the Magnum wire, generally used as a primary intervention for occlusive angi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of cardiology 1997-09, Vol.80 (5), p.634-637
Hauptverfasser: Allemann, Yves, Kaufmann, Urs P, Meyer, Beat J, Gunnes, Paul, Urban, Philip, Muülhauser, Bruno, Dorsaz, Pierre-André, Meier, Bernhard
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 637
container_issue 5
container_start_page 634
container_title The American journal of cardiology
container_volume 80
creator Allemann, Yves
Kaufmann, Urs P
Meyer, Beat J
Gunnes, Paul
Urban, Philip
Muülhauser, Bruno
Dorsaz, Pierre-André
Meier, Bernhard
description The experience in consecutive procedures with 800 recanalization attempts of chronic total coronary occlusions using the Magnum wire was analyzed from a prospectively constituted computerized database. The data confirm that the Magnum wire, generally used as a primary intervention for occlusive angioplasty at our centers, is competitive with conventional systems in this setting.
doi_str_mv 10.1016/S0002-9149(97)00438-4
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79274347</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0002914997004384</els_id><sourcerecordid>14527547</sourcerecordid><originalsourceid>FETCH-LOGICAL-c416t-6938d53ef00a1c210ec869f45f7026353c59ef7205757970c2483834d7f761683</originalsourceid><addsrcrecordid>eNqFkU1rVDEUhoModaz-hEIQEV1cPfm6SVZSB7-gUsGKuAoxN6kpmWRM7hX67810hlm4cRXCec6bc54gdEbgFQEyvv4KAHTQhOsXWr4E4EwN_B5aESX1QDRh99HqiDxEj1q76VdCxHiCTjTVXGu1Qj8-2-u8bPD3WD0OpeIvvrplttmXpeF1qSXbeovf2pRKyfg8X8eyTbbNtzhmrADwVZltwutfnYwOXzqXlhZLbo_Rg2BT808O5yn69v7d1frjcHH54dP6_GJwnIzzMGqmJsF8ALDEUQLeqVEHLoIEOjLBnNA-SApCCqklOMoVU4xPMsiRjIqdouf73G0tvxffZrOJzfmU9jsYqankjMsOPv0HvClLzX02Qxn0l4TapYk95GpprfpgtjVuugJDwOy8mzvvZifVaGnuvBve-84O4cvPjZ-OXQfRvf7sULfN2RSqzS62I0YVcDWSjr3ZY74b-xN9Nc1Fn52f-v-42Uwl_meQv2gpnD0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>230353588</pqid></control><display><type>article</type><title>Magnum Wire for Percutaneous Coronary Balloon Angioplasty in 800 Total Chronic Occlusions</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Allemann, Yves ; Kaufmann, Urs P ; Meyer, Beat J ; Gunnes, Paul ; Urban, Philip ; Muülhauser, Bruno ; Dorsaz, Pierre-André ; Meier, Bernhard</creator><creatorcontrib>Allemann, Yves ; Kaufmann, Urs P ; Meyer, Beat J ; Gunnes, Paul ; Urban, Philip ; Muülhauser, Bruno ; Dorsaz, Pierre-André ; Meier, Bernhard</creatorcontrib><description>The experience in consecutive procedures with 800 recanalization attempts of chronic total coronary occlusions using the Magnum wire was analyzed from a prospectively constituted computerized database. The data confirm that the Magnum wire, generally used as a primary intervention for occlusive angioplasty at our centers, is competitive with conventional systems in this setting.</description><identifier>ISSN: 0002-9149</identifier><identifier>EISSN: 1879-1913</identifier><identifier>DOI: 10.1016/S0002-9149(97)00438-4</identifier><identifier>PMID: 9294998</identifier><identifier>CODEN: AJCDAG</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Angioplasty ; Angioplasty, Balloon, Coronary - instrumentation ; Biological and medical sciences ; Cardiology. Vascular system ; Cardiovascular disease ; Coronary Angiography ; Coronary Disease - therapy ; Coronary heart disease ; Female ; Heart ; Humans ; Male ; Medical research ; Medical sciences ; Middle Aged ; Retrospective Studies ; Treatment Outcome</subject><ispartof>The American journal of cardiology, 1997-09, Vol.80 (5), p.634-637</ispartof><rights>1997 Elsevier Science Inc.</rights><rights>1997 INIST-CNRS</rights><rights>Copyright Elsevier Sequoia S.A. Sep 1, 1997</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c416t-6938d53ef00a1c210ec869f45f7026353c59ef7205757970c2483834d7f761683</citedby><cites>FETCH-LOGICAL-c416t-6938d53ef00a1c210ec869f45f7026353c59ef7205757970c2483834d7f761683</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0002-9149(97)00438-4$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2804861$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9294998$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Allemann, Yves</creatorcontrib><creatorcontrib>Kaufmann, Urs P</creatorcontrib><creatorcontrib>Meyer, Beat J</creatorcontrib><creatorcontrib>Gunnes, Paul</creatorcontrib><creatorcontrib>Urban, Philip</creatorcontrib><creatorcontrib>Muülhauser, Bruno</creatorcontrib><creatorcontrib>Dorsaz, Pierre-André</creatorcontrib><creatorcontrib>Meier, Bernhard</creatorcontrib><title>Magnum Wire for Percutaneous Coronary Balloon Angioplasty in 800 Total Chronic Occlusions</title><title>The American journal of cardiology</title><addtitle>Am J Cardiol</addtitle><description>The experience in consecutive procedures with 800 recanalization attempts of chronic total coronary occlusions using the Magnum wire was analyzed from a prospectively constituted computerized database. The data confirm that the Magnum wire, generally used as a primary intervention for occlusive angioplasty at our centers, is competitive with conventional systems in this setting.</description><subject>Angioplasty</subject><subject>Angioplasty, Balloon, Coronary - instrumentation</subject><subject>Biological and medical sciences</subject><subject>Cardiology. Vascular system</subject><subject>Cardiovascular disease</subject><subject>Coronary Angiography</subject><subject>Coronary Disease - therapy</subject><subject>Coronary heart disease</subject><subject>Female</subject><subject>Heart</subject><subject>Humans</subject><subject>Male</subject><subject>Medical research</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Retrospective Studies</subject><subject>Treatment Outcome</subject><issn>0002-9149</issn><issn>1879-1913</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkU1rVDEUhoModaz-hEIQEV1cPfm6SVZSB7-gUsGKuAoxN6kpmWRM7hX67810hlm4cRXCec6bc54gdEbgFQEyvv4KAHTQhOsXWr4E4EwN_B5aESX1QDRh99HqiDxEj1q76VdCxHiCTjTVXGu1Qj8-2-u8bPD3WD0OpeIvvrplttmXpeF1qSXbeovf2pRKyfg8X8eyTbbNtzhmrADwVZltwutfnYwOXzqXlhZLbo_Rg2BT808O5yn69v7d1frjcHH54dP6_GJwnIzzMGqmJsF8ALDEUQLeqVEHLoIEOjLBnNA-SApCCqklOMoVU4xPMsiRjIqdouf73G0tvxffZrOJzfmU9jsYqankjMsOPv0HvClLzX02Qxn0l4TapYk95GpprfpgtjVuugJDwOy8mzvvZifVaGnuvBve-84O4cvPjZ-OXQfRvf7sULfN2RSqzS62I0YVcDWSjr3ZY74b-xN9Nc1Fn52f-v-42Uwl_meQv2gpnD0</recordid><startdate>19970901</startdate><enddate>19970901</enddate><creator>Allemann, Yves</creator><creator>Kaufmann, Urs P</creator><creator>Meyer, Beat J</creator><creator>Gunnes, Paul</creator><creator>Urban, Philip</creator><creator>Muülhauser, Bruno</creator><creator>Dorsaz, Pierre-André</creator><creator>Meier, Bernhard</creator><general>Elsevier Inc</general><general>Elsevier</general><general>Elsevier Limited</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TS</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>NAPCQ</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>19970901</creationdate><title>Magnum Wire for Percutaneous Coronary Balloon Angioplasty in 800 Total Chronic Occlusions</title><author>Allemann, Yves ; Kaufmann, Urs P ; Meyer, Beat J ; Gunnes, Paul ; Urban, Philip ; Muülhauser, Bruno ; Dorsaz, Pierre-André ; Meier, Bernhard</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c416t-6938d53ef00a1c210ec869f45f7026353c59ef7205757970c2483834d7f761683</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Angioplasty</topic><topic>Angioplasty, Balloon, Coronary - instrumentation</topic><topic>Biological and medical sciences</topic><topic>Cardiology. Vascular system</topic><topic>Cardiovascular disease</topic><topic>Coronary Angiography</topic><topic>Coronary Disease - therapy</topic><topic>Coronary heart disease</topic><topic>Female</topic><topic>Heart</topic><topic>Humans</topic><topic>Male</topic><topic>Medical research</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Retrospective Studies</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Allemann, Yves</creatorcontrib><creatorcontrib>Kaufmann, Urs P</creatorcontrib><creatorcontrib>Meyer, Beat J</creatorcontrib><creatorcontrib>Gunnes, Paul</creatorcontrib><creatorcontrib>Urban, Philip</creatorcontrib><creatorcontrib>Muülhauser, Bruno</creatorcontrib><creatorcontrib>Dorsaz, Pierre-André</creatorcontrib><creatorcontrib>Meier, Bernhard</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Physical Education Index</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>The American journal of cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Allemann, Yves</au><au>Kaufmann, Urs P</au><au>Meyer, Beat J</au><au>Gunnes, Paul</au><au>Urban, Philip</au><au>Muülhauser, Bruno</au><au>Dorsaz, Pierre-André</au><au>Meier, Bernhard</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Magnum Wire for Percutaneous Coronary Balloon Angioplasty in 800 Total Chronic Occlusions</atitle><jtitle>The American journal of cardiology</jtitle><addtitle>Am J Cardiol</addtitle><date>1997-09-01</date><risdate>1997</risdate><volume>80</volume><issue>5</issue><spage>634</spage><epage>637</epage><pages>634-637</pages><issn>0002-9149</issn><eissn>1879-1913</eissn><coden>AJCDAG</coden><abstract>The experience in consecutive procedures with 800 recanalization attempts of chronic total coronary occlusions using the Magnum wire was analyzed from a prospectively constituted computerized database. The data confirm that the Magnum wire, generally used as a primary intervention for occlusive angioplasty at our centers, is competitive with conventional systems in this setting.</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>9294998</pmid><doi>10.1016/S0002-9149(97)00438-4</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0002-9149
ispartof The American journal of cardiology, 1997-09, Vol.80 (5), p.634-637
issn 0002-9149
1879-1913
language eng
recordid cdi_proquest_miscellaneous_79274347
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Angioplasty
Angioplasty, Balloon, Coronary - instrumentation
Biological and medical sciences
Cardiology. Vascular system
Cardiovascular disease
Coronary Angiography
Coronary Disease - therapy
Coronary heart disease
Female
Heart
Humans
Male
Medical research
Medical sciences
Middle Aged
Retrospective Studies
Treatment Outcome
title Magnum Wire for Percutaneous Coronary Balloon Angioplasty in 800 Total Chronic Occlusions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-31T16%3A13%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Magnum%20Wire%20for%20Percutaneous%20Coronary%20Balloon%20Angioplasty%20in%20800%20Total%20Chronic%20Occlusions&rft.jtitle=The%20American%20journal%20of%20cardiology&rft.au=Allemann,%20Yves&rft.date=1997-09-01&rft.volume=80&rft.issue=5&rft.spage=634&rft.epage=637&rft.pages=634-637&rft.issn=0002-9149&rft.eissn=1879-1913&rft.coden=AJCDAG&rft_id=info:doi/10.1016/S0002-9149(97)00438-4&rft_dat=%3Cproquest_cross%3E14527547%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=230353588&rft_id=info:pmid/9294998&rft_els_id=S0002914997004384&rfr_iscdi=true