I-123 Uptake in the Chest Wall After Needle Biopsy of a Pulmonary Nodule: A Cause for False—Positive I-123 Uptake

McDougall listed 42 cases of physiologic and pathologic causes of abnormal distribution of radioiodine that can be misinterpreted for metastatic cancer in whole-body I-131 scans. The authors previously presented infected sebaceous cyst in the scalp as a cause of false-positive I-123 uptake. The auth...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical nuclear medicine 1997-08, Vol.22 (8), p.572-573
Hauptverfasser: NADDAF, SLEIMAN Y, AKISIK, MUSTAFA F, OMAR, WALID S, YOUNG, IVEN, ABDEL-DAYEM, HUSSEIN M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 573
container_issue 8
container_start_page 572
container_title Clinical nuclear medicine
container_volume 22
creator NADDAF, SLEIMAN Y
AKISIK, MUSTAFA F
OMAR, WALID S
YOUNG, IVEN
ABDEL-DAYEM, HUSSEIN M
description McDougall listed 42 cases of physiologic and pathologic causes of abnormal distribution of radioiodine that can be misinterpreted for metastatic cancer in whole-body I-131 scans. The authors previously presented infected sebaceous cyst in the scalp as a cause of false-positive I-123 uptake. The authors use I-123 for routine thyroid scanning and for total-body search for metastatic thyroid cancer. The authors report one more false-positive result caused by oozing in the chest wall from the biopsy site for a pulmonary nodule.
doi_str_mv 10.1097/00003072-199708000-00021
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79220689</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79220689</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3291-64f42f2cea88065df459782344bb1a8ec49e3621bf2642a39acfd4b07e6185383</originalsourceid><addsrcrecordid>eNp1kc1uEzEQxy0EKqHwCEhzQNwW_LX-4BYiCpWq0gMVR8u7O1aWOnGwd1v1xkPwhDwJLgkRFyyNLOv_nxnPbwgBRt8wavVbWo-gmjfMWk1NfTU1OHtEFqwVqqGc28dkQYUSjdWKPyXPSvlGKVNMyRNyYrnilrULUs4bxgVc7yZ_gzBuYVojrNZYJvjqY4RlmDDDJeIQEd6PaVfuIQXwcDXHTdr6fA-XaZgjvoMlrPxcEELKcOZjwV8_fl6lMk7jLcK_bZ6TJ-FBf3G4T8n12Ycvq0_NxeeP56vlRdOL-rlGySB54D16Y6hqhyBbqw0XUnYd8wZ7aVEozrrAleReWN-HQXZUo2KmFUacktf7urucvs91JLcZS48x-i2muThtOafK2Go0e2OfUykZg9vlcVNnc4y6B97uL2935O3-8K6pLw895m6DwzHxALjqrw66L72PIfttP5ajjWvTMqOrTe5tdylW4OUmzneY3Rp9nNbuf9sWvwEcDpUC</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79220689</pqid></control><display><type>article</type><title>I-123 Uptake in the Chest Wall After Needle Biopsy of a Pulmonary Nodule: A Cause for False—Positive I-123 Uptake</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>NADDAF, SLEIMAN Y ; AKISIK, MUSTAFA F ; OMAR, WALID S ; YOUNG, IVEN ; ABDEL-DAYEM, HUSSEIN M</creator><creatorcontrib>NADDAF, SLEIMAN Y ; AKISIK, MUSTAFA F ; OMAR, WALID S ; YOUNG, IVEN ; ABDEL-DAYEM, HUSSEIN M</creatorcontrib><description>McDougall listed 42 cases of physiologic and pathologic causes of abnormal distribution of radioiodine that can be misinterpreted for metastatic cancer in whole-body I-131 scans. The authors previously presented infected sebaceous cyst in the scalp as a cause of false-positive I-123 uptake. The authors use I-123 for routine thyroid scanning and for total-body search for metastatic thyroid cancer. The authors report one more false-positive result caused by oozing in the chest wall from the biopsy site for a pulmonary nodule.</description><identifier>ISSN: 0363-9762</identifier><identifier>EISSN: 1536-0229</identifier><identifier>DOI: 10.1097/00003072-199708000-00021</identifier><identifier>PMID: 9262915</identifier><identifier>CODEN: CNMEDK</identifier><language>eng</language><publisher>Philadelphia, PA: Lippincott-Raven Publishers</publisher><subject>Aged ; Aged, 80 and over ; Biological and medical sciences ; False Positive Reactions ; Female ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Iodine Radioisotopes ; Lung Neoplasms - diagnostic imaging ; Medical sciences ; Radionuclide Imaging ; Radionuclide investigations ; Radiopharmaceuticals ; Respiratory system ; Thorax - diagnostic imaging ; Whole-Body Counting</subject><ispartof>Clinical nuclear medicine, 1997-08, Vol.22 (8), p.572-573</ispartof><rights>Lippincott-Raven Publishers</rights><rights>1997 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3291-64f42f2cea88065df459782344bb1a8ec49e3621bf2642a39acfd4b07e6185383</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,776,780,785,786,23909,23910,25118,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2785187$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9262915$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>NADDAF, SLEIMAN Y</creatorcontrib><creatorcontrib>AKISIK, MUSTAFA F</creatorcontrib><creatorcontrib>OMAR, WALID S</creatorcontrib><creatorcontrib>YOUNG, IVEN</creatorcontrib><creatorcontrib>ABDEL-DAYEM, HUSSEIN M</creatorcontrib><title>I-123 Uptake in the Chest Wall After Needle Biopsy of a Pulmonary Nodule: A Cause for False—Positive I-123 Uptake</title><title>Clinical nuclear medicine</title><addtitle>Clin Nucl Med</addtitle><description>McDougall listed 42 cases of physiologic and pathologic causes of abnormal distribution of radioiodine that can be misinterpreted for metastatic cancer in whole-body I-131 scans. The authors previously presented infected sebaceous cyst in the scalp as a cause of false-positive I-123 uptake. The authors use I-123 for routine thyroid scanning and for total-body search for metastatic thyroid cancer. The authors report one more false-positive result caused by oozing in the chest wall from the biopsy site for a pulmonary nodule.</description><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Biological and medical sciences</subject><subject>False Positive Reactions</subject><subject>Female</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Iodine Radioisotopes</subject><subject>Lung Neoplasms - diagnostic imaging</subject><subject>Medical sciences</subject><subject>Radionuclide Imaging</subject><subject>Radionuclide investigations</subject><subject>Radiopharmaceuticals</subject><subject>Respiratory system</subject><subject>Thorax - diagnostic imaging</subject><subject>Whole-Body Counting</subject><issn>0363-9762</issn><issn>1536-0229</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kc1uEzEQxy0EKqHwCEhzQNwW_LX-4BYiCpWq0gMVR8u7O1aWOnGwd1v1xkPwhDwJLgkRFyyNLOv_nxnPbwgBRt8wavVbWo-gmjfMWk1NfTU1OHtEFqwVqqGc28dkQYUSjdWKPyXPSvlGKVNMyRNyYrnilrULUs4bxgVc7yZ_gzBuYVojrNZYJvjqY4RlmDDDJeIQEd6PaVfuIQXwcDXHTdr6fA-XaZgjvoMlrPxcEELKcOZjwV8_fl6lMk7jLcK_bZ6TJ-FBf3G4T8n12Ycvq0_NxeeP56vlRdOL-rlGySB54D16Y6hqhyBbqw0XUnYd8wZ7aVEozrrAleReWN-HQXZUo2KmFUacktf7urucvs91JLcZS48x-i2muThtOafK2Go0e2OfUykZg9vlcVNnc4y6B97uL2935O3-8K6pLw895m6DwzHxALjqrw66L72PIfttP5ajjWvTMqOrTe5tdylW4OUmzneY3Rp9nNbuf9sWvwEcDpUC</recordid><startdate>199708</startdate><enddate>199708</enddate><creator>NADDAF, SLEIMAN Y</creator><creator>AKISIK, MUSTAFA F</creator><creator>OMAR, WALID S</creator><creator>YOUNG, IVEN</creator><creator>ABDEL-DAYEM, HUSSEIN M</creator><general>Lippincott-Raven Publishers</general><general>Lippincott</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199708</creationdate><title>I-123 Uptake in the Chest Wall After Needle Biopsy of a Pulmonary Nodule: A Cause for False—Positive I-123 Uptake</title><author>NADDAF, SLEIMAN Y ; AKISIK, MUSTAFA F ; OMAR, WALID S ; YOUNG, IVEN ; ABDEL-DAYEM, HUSSEIN M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3291-64f42f2cea88065df459782344bb1a8ec49e3621bf2642a39acfd4b07e6185383</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Biological and medical sciences</topic><topic>False Positive Reactions</topic><topic>Female</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Iodine Radioisotopes</topic><topic>Lung Neoplasms - diagnostic imaging</topic><topic>Medical sciences</topic><topic>Radionuclide Imaging</topic><topic>Radionuclide investigations</topic><topic>Radiopharmaceuticals</topic><topic>Respiratory system</topic><topic>Thorax - diagnostic imaging</topic><topic>Whole-Body Counting</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>NADDAF, SLEIMAN Y</creatorcontrib><creatorcontrib>AKISIK, MUSTAFA F</creatorcontrib><creatorcontrib>OMAR, WALID S</creatorcontrib><creatorcontrib>YOUNG, IVEN</creatorcontrib><creatorcontrib>ABDEL-DAYEM, HUSSEIN M</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical nuclear medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>NADDAF, SLEIMAN Y</au><au>AKISIK, MUSTAFA F</au><au>OMAR, WALID S</au><au>YOUNG, IVEN</au><au>ABDEL-DAYEM, HUSSEIN M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>I-123 Uptake in the Chest Wall After Needle Biopsy of a Pulmonary Nodule: A Cause for False—Positive I-123 Uptake</atitle><jtitle>Clinical nuclear medicine</jtitle><addtitle>Clin Nucl Med</addtitle><date>1997-08</date><risdate>1997</risdate><volume>22</volume><issue>8</issue><spage>572</spage><epage>573</epage><pages>572-573</pages><issn>0363-9762</issn><eissn>1536-0229</eissn><coden>CNMEDK</coden><abstract>McDougall listed 42 cases of physiologic and pathologic causes of abnormal distribution of radioiodine that can be misinterpreted for metastatic cancer in whole-body I-131 scans. The authors previously presented infected sebaceous cyst in the scalp as a cause of false-positive I-123 uptake. The authors use I-123 for routine thyroid scanning and for total-body search for metastatic thyroid cancer. The authors report one more false-positive result caused by oozing in the chest wall from the biopsy site for a pulmonary nodule.</abstract><cop>Philadelphia, PA</cop><cop>Hagerstown, MD</cop><pub>Lippincott-Raven Publishers</pub><pmid>9262915</pmid><doi>10.1097/00003072-199708000-00021</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0363-9762
ispartof Clinical nuclear medicine, 1997-08, Vol.22 (8), p.572-573
issn 0363-9762
1536-0229
language eng
recordid cdi_proquest_miscellaneous_79220689
source MEDLINE; Journals@Ovid Complete
subjects Aged
Aged, 80 and over
Biological and medical sciences
False Positive Reactions
Female
Humans
Investigative techniques, diagnostic techniques (general aspects)
Iodine Radioisotopes
Lung Neoplasms - diagnostic imaging
Medical sciences
Radionuclide Imaging
Radionuclide investigations
Radiopharmaceuticals
Respiratory system
Thorax - diagnostic imaging
Whole-Body Counting
title I-123 Uptake in the Chest Wall After Needle Biopsy of a Pulmonary Nodule: A Cause for False—Positive I-123 Uptake
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T03%3A15%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=I-123%20Uptake%20in%20the%20Chest%20Wall%20After%20Needle%20Biopsy%20of%20a%20Pulmonary%20Nodule:%20A%20Cause%20for%20False%E2%80%94Positive%20I-123%20Uptake&rft.jtitle=Clinical%20nuclear%20medicine&rft.au=NADDAF,%20SLEIMAN%20Y&rft.date=1997-08&rft.volume=22&rft.issue=8&rft.spage=572&rft.epage=573&rft.pages=572-573&rft.issn=0363-9762&rft.eissn=1536-0229&rft.coden=CNMEDK&rft_id=info:doi/10.1097/00003072-199708000-00021&rft_dat=%3Cproquest_cross%3E79220689%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79220689&rft_id=info:pmid/9262915&rfr_iscdi=true