Proximal tibial osteotomy: a new fixation device
A new internal fixation device was applied to 41 proximal tibial osteotomies to ensure against loss of postoperative correction. An oblique osteotomy was stabilized by two screws and a five-hole one-half tubular plate. Thirty-six patients with 41 proximal tibial osteotomies were reviewed for an aver...
Gespeichert in:
Veröffentlicht in: | Clinical orthopaedics and related research 1989-09, Vol.246 (246), p.250-259 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 259 |
---|---|
container_issue | 246 |
container_start_page | 250 |
container_title | Clinical orthopaedics and related research |
container_volume | 246 |
creator | MINIACI, A BALLMER, F. T BALLMER, P. M JAKOB, R. P |
description | A new internal fixation device was applied to 41 proximal tibial osteotomies to ensure against loss of postoperative correction. An oblique osteotomy was stabilized by two screws and a five-hole one-half tubular plate. Thirty-six patients with 41 proximal tibial osteotomies were reviewed for an average roentgenographic follow-up time of 22.6 months (range, six to 48 months) with no loss of correction. In addition, 16 patients with 19 osteotomies and a minimum clinical follow-up time of two years were reviewed using the Hospital for Special Surgery knee scoring system; these early results demonstrated a similar outcome to previously published series. The new fixation device is simple to use, permits early postoperative motion, and maintains the exact correction obtained at the time of surgery. |
doi_str_mv | 10.1097/00003086-198909000-00035 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79168377</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>79168377</sourcerecordid><originalsourceid>FETCH-LOGICAL-c284t-e99dab015006813fd1d27d51504353dd9e659f307d95fb6069882551c85aa9983</originalsourceid><addsrcrecordid>eNo9kE1PwzAMhiMEGmPwE5B6QNwK-Wg-zA1N40OaBAeQuEVpk0pBbTOaDrZ_T8bKfLH8-rUtPwhlBN8QDPIWp2BYiZyAAgypyncKP0JTwqnKCWH0GE2TBjlQ8nGKzmL83FkKTidoQqUQgrApwq992PjWNNngS59SiIMLQ2i3d5nJOveT1X5jBh-6zLpvX7lzdFKbJrqLMc_Q-8Pibf6UL18en-f3y7yiqhhyB2BNiQnHWCjCaksslZanumCcWQtOcKgZlhZ4XQosQCnKOakUNwZAsRm63u9d9eFr7eKgWx8r1zSmc2EdtQQiFJMyGdXeWPUhxt7VetWnh_qtJljvYOl_WPoAS__BSqOX44112Tp7GBzppP7V2DexMk3dm67y8WATggtZMPYL-FJvRA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79168377</pqid></control><display><type>article</type><title>Proximal tibial osteotomy: a new fixation device</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>MINIACI, A ; BALLMER, F. T ; BALLMER, P. M ; JAKOB, R. P</creator><creatorcontrib>MINIACI, A ; BALLMER, F. T ; BALLMER, P. M ; JAKOB, R. P</creatorcontrib><description>A new internal fixation device was applied to 41 proximal tibial osteotomies to ensure against loss of postoperative correction. An oblique osteotomy was stabilized by two screws and a five-hole one-half tubular plate. Thirty-six patients with 41 proximal tibial osteotomies were reviewed for an average roentgenographic follow-up time of 22.6 months (range, six to 48 months) with no loss of correction. In addition, 16 patients with 19 osteotomies and a minimum clinical follow-up time of two years were reviewed using the Hospital for Special Surgery knee scoring system; these early results demonstrated a similar outcome to previously published series. The new fixation device is simple to use, permits early postoperative motion, and maintains the exact correction obtained at the time of surgery.</description><identifier>ISSN: 0009-921X</identifier><identifier>EISSN: 1528-1132</identifier><identifier>DOI: 10.1097/00003086-198909000-00035</identifier><identifier>PMID: 2766613</identifier><identifier>CODEN: CORTBR</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Arthritis - surgery ; Biological and medical sciences ; Bone Plates ; Bone Screws ; Female ; Follow-Up Studies ; Humans ; Knee Joint ; Male ; Medical sciences ; Middle Aged ; Orthopedic Fixation Devices ; Orthopedic surgery ; Osteotomy - instrumentation ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Tibia - surgery ; Time Factors</subject><ispartof>Clinical orthopaedics and related research, 1989-09, Vol.246 (246), p.250-259</ispartof><rights>1990 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=6656743$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2766613$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>MINIACI, A</creatorcontrib><creatorcontrib>BALLMER, F. T</creatorcontrib><creatorcontrib>BALLMER, P. M</creatorcontrib><creatorcontrib>JAKOB, R. P</creatorcontrib><title>Proximal tibial osteotomy: a new fixation device</title><title>Clinical orthopaedics and related research</title><addtitle>Clin Orthop Relat Res</addtitle><description>A new internal fixation device was applied to 41 proximal tibial osteotomies to ensure against loss of postoperative correction. An oblique osteotomy was stabilized by two screws and a five-hole one-half tubular plate. Thirty-six patients with 41 proximal tibial osteotomies were reviewed for an average roentgenographic follow-up time of 22.6 months (range, six to 48 months) with no loss of correction. In addition, 16 patients with 19 osteotomies and a minimum clinical follow-up time of two years were reviewed using the Hospital for Special Surgery knee scoring system; these early results demonstrated a similar outcome to previously published series. The new fixation device is simple to use, permits early postoperative motion, and maintains the exact correction obtained at the time of surgery.</description><subject>Arthritis - surgery</subject><subject>Biological and medical sciences</subject><subject>Bone Plates</subject><subject>Bone Screws</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Humans</subject><subject>Knee Joint</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Orthopedic Fixation Devices</subject><subject>Orthopedic surgery</subject><subject>Osteotomy - instrumentation</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Tibia - surgery</subject><subject>Time Factors</subject><issn>0009-921X</issn><issn>1528-1132</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kE1PwzAMhiMEGmPwE5B6QNwK-Wg-zA1N40OaBAeQuEVpk0pBbTOaDrZ_T8bKfLH8-rUtPwhlBN8QDPIWp2BYiZyAAgypyncKP0JTwqnKCWH0GE2TBjlQ8nGKzmL83FkKTidoQqUQgrApwq992PjWNNngS59SiIMLQ2i3d5nJOveT1X5jBh-6zLpvX7lzdFKbJrqLMc_Q-8Pibf6UL18en-f3y7yiqhhyB2BNiQnHWCjCaksslZanumCcWQtOcKgZlhZ4XQosQCnKOakUNwZAsRm63u9d9eFr7eKgWx8r1zSmc2EdtQQiFJMyGdXeWPUhxt7VetWnh_qtJljvYOl_WPoAS__BSqOX44112Tp7GBzppP7V2DexMk3dm67y8WATggtZMPYL-FJvRA</recordid><startdate>19890901</startdate><enddate>19890901</enddate><creator>MINIACI, A</creator><creator>BALLMER, F. T</creator><creator>BALLMER, P. M</creator><creator>JAKOB, R. P</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19890901</creationdate><title>Proximal tibial osteotomy: a new fixation device</title><author>MINIACI, A ; BALLMER, F. T ; BALLMER, P. M ; JAKOB, R. P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c284t-e99dab015006813fd1d27d51504353dd9e659f307d95fb6069882551c85aa9983</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>Arthritis - surgery</topic><topic>Biological and medical sciences</topic><topic>Bone Plates</topic><topic>Bone Screws</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Humans</topic><topic>Knee Joint</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Orthopedic Fixation Devices</topic><topic>Orthopedic surgery</topic><topic>Osteotomy - instrumentation</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Tibia - surgery</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>MINIACI, A</creatorcontrib><creatorcontrib>BALLMER, F. T</creatorcontrib><creatorcontrib>BALLMER, P. M</creatorcontrib><creatorcontrib>JAKOB, R. P</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical orthopaedics and related research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MINIACI, A</au><au>BALLMER, F. T</au><au>BALLMER, P. M</au><au>JAKOB, R. P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Proximal tibial osteotomy: a new fixation device</atitle><jtitle>Clinical orthopaedics and related research</jtitle><addtitle>Clin Orthop Relat Res</addtitle><date>1989-09-01</date><risdate>1989</risdate><volume>246</volume><issue>246</issue><spage>250</spage><epage>259</epage><pages>250-259</pages><issn>0009-921X</issn><eissn>1528-1132</eissn><coden>CORTBR</coden><abstract>A new internal fixation device was applied to 41 proximal tibial osteotomies to ensure against loss of postoperative correction. An oblique osteotomy was stabilized by two screws and a five-hole one-half tubular plate. Thirty-six patients with 41 proximal tibial osteotomies were reviewed for an average roentgenographic follow-up time of 22.6 months (range, six to 48 months) with no loss of correction. In addition, 16 patients with 19 osteotomies and a minimum clinical follow-up time of two years were reviewed using the Hospital for Special Surgery knee scoring system; these early results demonstrated a similar outcome to previously published series. The new fixation device is simple to use, permits early postoperative motion, and maintains the exact correction obtained at the time of surgery.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>2766613</pmid><doi>10.1097/00003086-198909000-00035</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0009-921X |
ispartof | Clinical orthopaedics and related research, 1989-09, Vol.246 (246), p.250-259 |
issn | 0009-921X 1528-1132 |
language | eng |
recordid | cdi_proquest_miscellaneous_79168377 |
source | MEDLINE; Journals@Ovid Complete |
subjects | Arthritis - surgery Biological and medical sciences Bone Plates Bone Screws Female Follow-Up Studies Humans Knee Joint Male Medical sciences Middle Aged Orthopedic Fixation Devices Orthopedic surgery Osteotomy - instrumentation Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Tibia - surgery Time Factors |
title | Proximal tibial osteotomy: a new fixation device |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T20%3A20%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Proximal%20tibial%20osteotomy:%20a%20new%20fixation%20device&rft.jtitle=Clinical%20orthopaedics%20and%20related%20research&rft.au=MINIACI,%20A&rft.date=1989-09-01&rft.volume=246&rft.issue=246&rft.spage=250&rft.epage=259&rft.pages=250-259&rft.issn=0009-921X&rft.eissn=1528-1132&rft.coden=CORTBR&rft_id=info:doi/10.1097/00003086-198909000-00035&rft_dat=%3Cproquest_cross%3E79168377%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79168377&rft_id=info:pmid/2766613&rfr_iscdi=true |