The apical long-axis rather than the two-chamber view should be used in combination with the four-chamber view for accurate assessment of left ventricular volumes and function
Background Most biplane methods for the echocardiographic calculation of left ventricular volumes assume orthogonality between paired views from the apical window. Our aim was to study the accuracy of biplane left ventricular volume calculations when either the apical two-chamber or long-axis views...
Gespeichert in:
Veröffentlicht in: | European heart journal 1997-07, Vol.18 (7), p.1175-1185 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background Most biplane methods for the echocardiographic calculation of left ventricular volumes assume orthogonality between paired views from the apical window. Our aim was to study the accuracy of biplane left ventricular volume calculations when either the apical two-chamber or long-axis views are combined with the four-chamber view. The left ventricular volumes calculated from three-dimensional echocardiographic data sets were used as a reference. Twenty-seven patients underwent precordial three-dimensional echocardiography using rotational acquisition of planes at 2-degree intervals, with ECG and respiratory gating. End-diastolic and end-systolic left ventricular volumes and ejection fraction on three-dimensional echocardiography were calculated by (1) Simpson's methods (3DS) at 3 mm short-axis slice thickness (reference method) and by (2) biplane ellipse from paired views using either apical four- and two-chamber views (BE-A) or apical four- and long-axis views (BE-B). Observer variabilities were studied by the standard error of the estimate % (SEE) in 19 patients for all methods. Results The spatial angles (mean±SD) between the apical two-chamber, long-axis and four-chamber views were 63·3°±19·7 and 99·1°±25·6 respectively. The mean±SD of end-diastolic and end-systolic left ventricular volumes (ml) and ejection fraction (%) by 3DS were 14·2±60·9, 91·8±59·6 and 39·6±17·5, while that by BE-A were 126·7±60·4, 84·0±57·9 and 39±17 and by BE-B were 134·3±62·4, 88·6±59·7 and 39·1±16·7, respectively. BE-B intra-observer (8·4, 6·7 and 3·5) and inter-observer (9·8, 11·5 and 5·) SEE for end-diastolic and end-systolic left ventricular volumes (ml) and ejection fraction (%), respectively, were smaller than that for BE-A (10·8, 8·8 and 4·1 and 11·4, 14·7 and 6·1, respectively). There was excellent correlation between 3DS and BE-A (r=0·99, 0·98 and 0·98) and BE-B (0·98, 0·98 and 0·98) for calculating end-diastolic and end-systolic left ventricular volume and ejection fractions, respectively. There were no significant differences between BE-A and BE-B with 3DS for end-diastolic and end-systolic left ventricular volume and ejection fraction calculations (P=0·2, 0·3 and 0·4 and P=0·5, 0·5 and 0·4, respectively). There were closer limits of agreement (mean±2 SD) between 3DS and BE-B 7·9±18·8, 3·2±14·2 and 0·8±5·8 than that between 3DS and BE-A 15·5±19·6, 7·8±16·2 and 1·1±7·4 for calculating end-diastolic and end-systolic left ventricular volume and ejection fraction |
---|---|
ISSN: | 0195-668X 1522-9645 |
DOI: | 10.1093/oxfordjournals.eurheartj.a015414 |