Yield and complications in percutaneous renal biopsy: A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys
Purpose: to compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy. Material and Methods: A total of 448 biopies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies...
Gespeichert in:
Veröffentlicht in: | Acta radiologica (1987) 1997-05, Vol.38 (3), p.431-436 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 436 |
---|---|
container_issue | 3 |
container_start_page | 431 |
container_title | Acta radiologica (1987) |
container_volume | 38 |
creator | Nyman, R. S. Cappelen-Smith, J. Al Suhaibani, H. Alfurayh, O. Shakweer, W. Akhtar, M. |
description | Purpose: to compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy.
Material and Methods: A total of 448 biopies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. the gun-biopsies were performed under real-time ultrasound (US) guidance. the manual technique used US mainly for marking the position of the kidney.
Results: There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group.
Conclusion: Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications. |
doi_str_mv | 10.1080/02841859709172096 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79063485</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1080_02841859709172096</sage_id><sourcerecordid>79063485</sourcerecordid><originalsourceid>FETCH-LOGICAL-c316t-82fc814f73d7e9530ca2d02e7dd33de4aee97a7abee3912af59c493e597432143</originalsourceid><addsrcrecordid>eNp9kDtPxDAQhC0EOo6DH0CBlALR5fArcVwixEs6iQYKqmjP3iCf8sJOivv3-JToGiSqLeab2d0h5JrRNaMFvae8kKzItKKaKU51fkKWLKc0pTLLTsnyoKcRYOfkIoQdpYyrjC3IQjPNpMiXRH45rG0CrU1M1_S1MzC4rg2Ja5MevRkHaLEbQ-KxhTrZuq4P-0tyVkEd8GqeK_L5_PTx-Jpu3l_eHh82qREsH9KCV6ZgslLCKtSZoAa4pRyVtUJYlICoFSjYIgrNOFSZNlILjP9IweN9K3I35fa--xkxDGXjgsG6nm4qlaa5kEUWQTaBxncheKzK3rsG_L5ktDw0Vf5pKnpu5vBx26A9OuZqon476xAM1JWH1rhwxHiuIlhEbD1hAb6x3HWjjz2Ff_b-Av3NfHY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79063485</pqid></control><display><type>article</type><title>Yield and complications in percutaneous renal biopsy: A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys</title><source>MEDLINE</source><source>Taylor & Francis Journals Complete</source><creator>Nyman, R. S. ; Cappelen-Smith, J. ; Al Suhaibani, H. ; Alfurayh, O. ; Shakweer, W. ; Akhtar, M.</creator><creatorcontrib>Nyman, R. S. ; Cappelen-Smith, J. ; Al Suhaibani, H. ; Alfurayh, O. ; Shakweer, W. ; Akhtar, M.</creatorcontrib><description>Purpose: to compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy.
Material and Methods: A total of 448 biopies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. the gun-biopsies were performed under real-time ultrasound (US) guidance. the manual technique used US mainly for marking the position of the kidney.
Results: There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group.
Conclusion: Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.</description><identifier>ISSN: 0284-1851</identifier><identifier>EISSN: 1600-0455</identifier><identifier>DOI: 10.1080/02841859709172096</identifier><identifier>PMID: 9191436</identifier><identifier>CODEN: ACRAE3</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Adolescent ; Adult ; Aged ; Aged, 80 and over ; Arteriovenous Fistula - etiology ; Biological and medical sciences ; Biopsy, Needle - adverse effects ; Biopsy, Needle - methods ; Blood Transfusion ; Child ; Child, Preschool ; Female ; Hematoma - etiology ; Hematuria - etiology ; Humans ; Infant ; Kidney - diagnostic imaging ; Kidney - pathology ; Kidney - surgery ; Kidney Glomerulus - pathology ; Kidney Transplantation - diagnostic imaging ; Kidney Transplantation - pathology ; Male ; Medical sciences ; Middle Aged ; Nephrostomy, Percutaneous ; Risk Factors ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Surgery of the urinary system ; Therapeutic Irrigation ; Ultrasonography, Interventional - adverse effects ; Urinary Bladder - injuries</subject><ispartof>Acta radiologica (1987), 1997-05, Vol.38 (3), p.431-436</ispartof><rights>Acta Radiologica</rights><rights>1997 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=2671918$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9191436$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nyman, R. S.</creatorcontrib><creatorcontrib>Cappelen-Smith, J.</creatorcontrib><creatorcontrib>Al Suhaibani, H.</creatorcontrib><creatorcontrib>Alfurayh, O.</creatorcontrib><creatorcontrib>Shakweer, W.</creatorcontrib><creatorcontrib>Akhtar, M.</creatorcontrib><title>Yield and complications in percutaneous renal biopsy: A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys</title><title>Acta radiologica (1987)</title><addtitle>Acta Radiol</addtitle><description>Purpose: to compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy.
Material and Methods: A total of 448 biopies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. the gun-biopsies were performed under real-time ultrasound (US) guidance. the manual technique used US mainly for marking the position of the kidney.
Results: There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group.
Conclusion: Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Arteriovenous Fistula - etiology</subject><subject>Biological and medical sciences</subject><subject>Biopsy, Needle - adverse effects</subject><subject>Biopsy, Needle - methods</subject><subject>Blood Transfusion</subject><subject>Child</subject><subject>Child, Preschool</subject><subject>Female</subject><subject>Hematoma - etiology</subject><subject>Hematuria - etiology</subject><subject>Humans</subject><subject>Infant</subject><subject>Kidney - diagnostic imaging</subject><subject>Kidney - pathology</subject><subject>Kidney - surgery</subject><subject>Kidney Glomerulus - pathology</subject><subject>Kidney Transplantation - diagnostic imaging</subject><subject>Kidney Transplantation - pathology</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Nephrostomy, Percutaneous</subject><subject>Risk Factors</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Surgery of the urinary system</subject><subject>Therapeutic Irrigation</subject><subject>Ultrasonography, Interventional - adverse effects</subject><subject>Urinary Bladder - injuries</subject><issn>0284-1851</issn><issn>1600-0455</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kDtPxDAQhC0EOo6DH0CBlALR5fArcVwixEs6iQYKqmjP3iCf8sJOivv3-JToGiSqLeab2d0h5JrRNaMFvae8kKzItKKaKU51fkKWLKc0pTLLTsnyoKcRYOfkIoQdpYyrjC3IQjPNpMiXRH45rG0CrU1M1_S1MzC4rg2Ja5MevRkHaLEbQ-KxhTrZuq4P-0tyVkEd8GqeK_L5_PTx-Jpu3l_eHh82qREsH9KCV6ZgslLCKtSZoAa4pRyVtUJYlICoFSjYIgrNOFSZNlILjP9IweN9K3I35fa--xkxDGXjgsG6nm4qlaa5kEUWQTaBxncheKzK3rsG_L5ktDw0Vf5pKnpu5vBx26A9OuZqon476xAM1JWH1rhwxHiuIlhEbD1hAb6x3HWjjz2Ff_b-Av3NfHY</recordid><startdate>19970501</startdate><enddate>19970501</enddate><creator>Nyman, R. S.</creator><creator>Cappelen-Smith, J.</creator><creator>Al Suhaibani, H.</creator><creator>Alfurayh, O.</creator><creator>Shakweer, W.</creator><creator>Akhtar, M.</creator><general>SAGE Publications</general><general>Taylor & Francis</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19970501</creationdate><title>Yield and complications in percutaneous renal biopsy</title><author>Nyman, R. S. ; Cappelen-Smith, J. ; Al Suhaibani, H. ; Alfurayh, O. ; Shakweer, W. ; Akhtar, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c316t-82fc814f73d7e9530ca2d02e7dd33de4aee97a7abee3912af59c493e597432143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Arteriovenous Fistula - etiology</topic><topic>Biological and medical sciences</topic><topic>Biopsy, Needle - adverse effects</topic><topic>Biopsy, Needle - methods</topic><topic>Blood Transfusion</topic><topic>Child</topic><topic>Child, Preschool</topic><topic>Female</topic><topic>Hematoma - etiology</topic><topic>Hematuria - etiology</topic><topic>Humans</topic><topic>Infant</topic><topic>Kidney - diagnostic imaging</topic><topic>Kidney - pathology</topic><topic>Kidney - surgery</topic><topic>Kidney Glomerulus - pathology</topic><topic>Kidney Transplantation - diagnostic imaging</topic><topic>Kidney Transplantation - pathology</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Nephrostomy, Percutaneous</topic><topic>Risk Factors</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Surgery of the urinary system</topic><topic>Therapeutic Irrigation</topic><topic>Ultrasonography, Interventional - adverse effects</topic><topic>Urinary Bladder - injuries</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nyman, R. S.</creatorcontrib><creatorcontrib>Cappelen-Smith, J.</creatorcontrib><creatorcontrib>Al Suhaibani, H.</creatorcontrib><creatorcontrib>Alfurayh, O.</creatorcontrib><creatorcontrib>Shakweer, W.</creatorcontrib><creatorcontrib>Akhtar, M.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Acta radiologica (1987)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nyman, R. S.</au><au>Cappelen-Smith, J.</au><au>Al Suhaibani, H.</au><au>Alfurayh, O.</au><au>Shakweer, W.</au><au>Akhtar, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Yield and complications in percutaneous renal biopsy: A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys</atitle><jtitle>Acta radiologica (1987)</jtitle><addtitle>Acta Radiol</addtitle><date>1997-05-01</date><risdate>1997</risdate><volume>38</volume><issue>3</issue><spage>431</spage><epage>436</epage><pages>431-436</pages><issn>0284-1851</issn><eissn>1600-0455</eissn><coden>ACRAE3</coden><abstract>Purpose: to compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy.
Material and Methods: A total of 448 biopies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. the gun-biopsies were performed under real-time ultrasound (US) guidance. the manual technique used US mainly for marking the position of the kidney.
Results: There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group.
Conclusion: Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>9191436</pmid><doi>10.1080/02841859709172096</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0284-1851 |
ispartof | Acta radiologica (1987), 1997-05, Vol.38 (3), p.431-436 |
issn | 0284-1851 1600-0455 |
language | eng |
recordid | cdi_proquest_miscellaneous_79063485 |
source | MEDLINE; Taylor & Francis Journals Complete |
subjects | Adolescent Adult Aged Aged, 80 and over Arteriovenous Fistula - etiology Biological and medical sciences Biopsy, Needle - adverse effects Biopsy, Needle - methods Blood Transfusion Child Child, Preschool Female Hematoma - etiology Hematuria - etiology Humans Infant Kidney - diagnostic imaging Kidney - pathology Kidney - surgery Kidney Glomerulus - pathology Kidney Transplantation - diagnostic imaging Kidney Transplantation - pathology Male Medical sciences Middle Aged Nephrostomy, Percutaneous Risk Factors Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Surgery of the urinary system Therapeutic Irrigation Ultrasonography, Interventional - adverse effects Urinary Bladder - injuries |
title | Yield and complications in percutaneous renal biopsy: A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T04%3A06%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Yield%20and%20complications%20in%20percutaneous%20renal%20biopsy:%20A%20comparison%20between%20ultrasound-guided%20gun-biopsy%20and%20manual%20techniques%20in%20native%20and%20transplant%20kidneys&rft.jtitle=Acta%20radiologica%20(1987)&rft.au=Nyman,%20R.%20S.&rft.date=1997-05-01&rft.volume=38&rft.issue=3&rft.spage=431&rft.epage=436&rft.pages=431-436&rft.issn=0284-1851&rft.eissn=1600-0455&rft.coden=ACRAE3&rft_id=info:doi/10.1080/02841859709172096&rft_dat=%3Cproquest_cross%3E79063485%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=79063485&rft_id=info:pmid/9191436&rft_sage_id=10.1080_02841859709172096&rfr_iscdi=true |