Patient comfort during cataract surgery with modified topical and peribulbar anesthesia

Purpose: To evaluate patient comfort during cataract surgery performed using modified topical and peribulbar anesthesia. Setting: Sunderland Eye Infirmary Cataract Treatment Centre, Sunderland, United Kingdom. Methods: In this prospective study, 50 consecutive patients scheduled for cataract surgery...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cataract and refractive surgery 1997-03, Vol.23 (2), p.277-283
Hauptverfasser: Maclean, Hunter, Burton, Ted, Murray, Aiden
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose: To evaluate patient comfort during cataract surgery performed using modified topical and peribulbar anesthesia. Setting: Sunderland Eye Infirmary Cataract Treatment Centre, Sunderland, United Kingdom. Methods: In this prospective study, 50 consecutive patients scheduled for cataract surgery with local anesthesia were randomly assigned to receive topical bupivacaine hydrochloride plus 0.1 mL subconjunctival fgnocaine or standard peribulbar anesthesia. All surgery was performed by one surgeon using a scleral pocket bimanual phacoemulsification technique. Patients were asked to grade the pain experienced during administration of the anesthetic and during cataract surgery using a visual analog scale. Results: No statistically significant difference in patient comfort was demonstrated between the two groups during cataract surgery (P < .4, Wilcoxon rank-sum test), and all patients were satisfied with the anesthesia. However, administration of topical bupivacaine was significantly less painful than peribulbar injections (P < .001, Wilcoxon rank-sum test). In eight patients in the topical anesthesia group, the cataract in the fellow eye was removed using peribulbar anesthesia; seven of these patients stated a preference for the modified topical method, while one patient thought there was no difference between the two methods. There was no difference between the groups in surgical complications, but 24% of the peribulbar group had a minor subconjunctival hemorrhage at the needle entry site. Conclusion: The modified topical technique provided satisfactory patient comfort during cataract surgery; it was comparable to the comfort achieved using peribulbar injections. The speed and ease of administering topical anesthesia coupled with the rapid visual recovery after surgery makes this method a suitable and safe choice for day-case phacoemulsification cataract surgery.
ISSN:0886-3350
1873-4502
DOI:10.1016/S0886-3350(97)80354-9