New method for spectrofluorometer monochromator wavelength calibration

A method is presented for wavelength calibration of spectrofluorometer monochromators. It is based on the distortion that the characteristic absorption bands of glass filters (holmium or didymium oxide), commonly used for calibration of spectrophotometers, introduce in the emitted fluorescence of fl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biochemical and biophysical methods 1988-09, Vol.17 (1), p.61-66
Hauptverfasser: Paladini, A A, Erijman, L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 66
container_issue 1
container_start_page 61
container_title Journal of biochemical and biophysical methods
container_volume 17
creator Paladini, A A
Erijman, L
description A method is presented for wavelength calibration of spectrofluorometer monochromators. It is based on the distortion that the characteristic absorption bands of glass filters (holmium or didymium oxide), commonly used for calibration of spectrophotometers, introduce in the emitted fluorescence of fluorophores like indole, diphenyl hexatriene, xylene or rhodamine 6G. Those filters or a well characterized absorber with sharp bands like benzene vapor can be used for the same purpose. The wavelength calibration accuracy obtained with this method is better than 0.1 nm, and requires no modification in the geometry of the spectrofluorometer sample compartment.
doi_str_mv 10.1016/0165-022X(88)90079-6
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_78699055</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>15100252</sourcerecordid><originalsourceid>FETCH-LOGICAL-p169t-13c2e746a1b914e97400ee725bf2ae6fad07ea00f28777c25bdeda298bc07363</originalsourceid><addsrcrecordid>eNqFkD1PwzAURT2ASin8A5AyIRgCz3bijxFVFJAqWDqwRY7zQoKSONgOFf-eSFSsDE9X9-joDo-QCwq3FKi4my9PgbG3a6VuNIDUqTgiyz98Qk5D-AAArli2IAvOeC6FWpLNC-6THmPjqqR2Pgkj2uhd3U3Ou5mjT3o3ONvMzcRZ2Jsv7HB4j01iTdeW3sTWDWfkuDZdwPNDrshu87BbP6Xb18fn9f02HanQMaXcMpSZMLTUNEMtMwBEyfKyZgZFbSqQaABqpqSUduYVVoZpVVqQXPAVufqdHb37nDDEom-Dxa4zA7opFFIJrSHP_xVpTgFYzmbx8iBOZY9VMfq2N_67ODyI_wCvCWfa</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>15100252</pqid></control><display><type>article</type><title>New method for spectrofluorometer monochromator wavelength calibration</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Paladini, A A ; Erijman, L</creator><creatorcontrib>Paladini, A A ; Erijman, L</creatorcontrib><description>A method is presented for wavelength calibration of spectrofluorometer monochromators. It is based on the distortion that the characteristic absorption bands of glass filters (holmium or didymium oxide), commonly used for calibration of spectrophotometers, introduce in the emitted fluorescence of fluorophores like indole, diphenyl hexatriene, xylene or rhodamine 6G. Those filters or a well characterized absorber with sharp bands like benzene vapor can be used for the same purpose. The wavelength calibration accuracy obtained with this method is better than 0.1 nm, and requires no modification in the geometry of the spectrofluorometer sample compartment.</description><identifier>ISSN: 0165-022X</identifier><identifier>DOI: 10.1016/0165-022X(88)90079-6</identifier><identifier>PMID: 3235768</identifier><language>eng</language><publisher>Netherlands</publisher><subject>Calibration ; fluorescence ; spectrofluorometry ; Spectrometry, Fluorescence - instrumentation ; spectroscopy ; wavelength ; Weights and Measures</subject><ispartof>Journal of biochemical and biophysical methods, 1988-09, Vol.17 (1), p.61-66</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/3235768$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Paladini, A A</creatorcontrib><creatorcontrib>Erijman, L</creatorcontrib><title>New method for spectrofluorometer monochromator wavelength calibration</title><title>Journal of biochemical and biophysical methods</title><addtitle>J Biochem Biophys Methods</addtitle><description>A method is presented for wavelength calibration of spectrofluorometer monochromators. It is based on the distortion that the characteristic absorption bands of glass filters (holmium or didymium oxide), commonly used for calibration of spectrophotometers, introduce in the emitted fluorescence of fluorophores like indole, diphenyl hexatriene, xylene or rhodamine 6G. Those filters or a well characterized absorber with sharp bands like benzene vapor can be used for the same purpose. The wavelength calibration accuracy obtained with this method is better than 0.1 nm, and requires no modification in the geometry of the spectrofluorometer sample compartment.</description><subject>Calibration</subject><subject>fluorescence</subject><subject>spectrofluorometry</subject><subject>Spectrometry, Fluorescence - instrumentation</subject><subject>spectroscopy</subject><subject>wavelength</subject><subject>Weights and Measures</subject><issn>0165-022X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1988</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkD1PwzAURT2ASin8A5AyIRgCz3bijxFVFJAqWDqwRY7zQoKSONgOFf-eSFSsDE9X9-joDo-QCwq3FKi4my9PgbG3a6VuNIDUqTgiyz98Qk5D-AAArli2IAvOeC6FWpLNC-6THmPjqqR2Pgkj2uhd3U3Ou5mjT3o3ONvMzcRZ2Jsv7HB4j01iTdeW3sTWDWfkuDZdwPNDrshu87BbP6Xb18fn9f02HanQMaXcMpSZMLTUNEMtMwBEyfKyZgZFbSqQaABqpqSUduYVVoZpVVqQXPAVufqdHb37nDDEom-Dxa4zA7opFFIJrSHP_xVpTgFYzmbx8iBOZY9VMfq2N_67ODyI_wCvCWfa</recordid><startdate>19880901</startdate><enddate>19880901</enddate><creator>Paladini, A A</creator><creator>Erijman, L</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7QL</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>M81</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>19880901</creationdate><title>New method for spectrofluorometer monochromator wavelength calibration</title><author>Paladini, A A ; Erijman, L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p169t-13c2e746a1b914e97400ee725bf2ae6fad07ea00f28777c25bdeda298bc07363</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1988</creationdate><topic>Calibration</topic><topic>fluorescence</topic><topic>spectrofluorometry</topic><topic>Spectrometry, Fluorescence - instrumentation</topic><topic>spectroscopy</topic><topic>wavelength</topic><topic>Weights and Measures</topic><toplevel>online_resources</toplevel><creatorcontrib>Paladini, A A</creatorcontrib><creatorcontrib>Erijman, L</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biochemistry Abstracts 3</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of biochemical and biophysical methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Paladini, A A</au><au>Erijman, L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>New method for spectrofluorometer monochromator wavelength calibration</atitle><jtitle>Journal of biochemical and biophysical methods</jtitle><addtitle>J Biochem Biophys Methods</addtitle><date>1988-09-01</date><risdate>1988</risdate><volume>17</volume><issue>1</issue><spage>61</spage><epage>66</epage><pages>61-66</pages><issn>0165-022X</issn><abstract>A method is presented for wavelength calibration of spectrofluorometer monochromators. It is based on the distortion that the characteristic absorption bands of glass filters (holmium or didymium oxide), commonly used for calibration of spectrophotometers, introduce in the emitted fluorescence of fluorophores like indole, diphenyl hexatriene, xylene or rhodamine 6G. Those filters or a well characterized absorber with sharp bands like benzene vapor can be used for the same purpose. The wavelength calibration accuracy obtained with this method is better than 0.1 nm, and requires no modification in the geometry of the spectrofluorometer sample compartment.</abstract><cop>Netherlands</cop><pmid>3235768</pmid><doi>10.1016/0165-022X(88)90079-6</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0165-022X
ispartof Journal of biochemical and biophysical methods, 1988-09, Vol.17 (1), p.61-66
issn 0165-022X
language eng
recordid cdi_proquest_miscellaneous_78699055
source MEDLINE; Alma/SFX Local Collection
subjects Calibration
fluorescence
spectrofluorometry
Spectrometry, Fluorescence - instrumentation
spectroscopy
wavelength
Weights and Measures
title New method for spectrofluorometer monochromator wavelength calibration
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T17%3A27%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=New%20method%20for%20spectrofluorometer%20monochromator%20wavelength%20calibration&rft.jtitle=Journal%20of%20biochemical%20and%20biophysical%20methods&rft.au=Paladini,%20A%20A&rft.date=1988-09-01&rft.volume=17&rft.issue=1&rft.spage=61&rft.epage=66&rft.pages=61-66&rft.issn=0165-022X&rft_id=info:doi/10.1016/0165-022X(88)90079-6&rft_dat=%3Cproquest_pubme%3E15100252%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=15100252&rft_id=info:pmid/3235768&rfr_iscdi=true