Reproducibility of studies of peritoneal dialysis adequacy

Reproducibility of studies of peritoneal dialysis adequacy. To assess the variability and reproducibility of dialysis adequacy clearance measurements (weekly Kt/V and weekly creatinine clearance/1.73m2 BSA) in a given patient, 42 patients underwent three clearance studies in a one week period. The d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Kidney international 1996-07, Vol.50 (1), p.267-271
Hauptverfasser: Rodby, Roger A., Firanek, Catherine A., Cheng, Yong-Gang, Korbet, Stephen M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 271
container_issue 1
container_start_page 267
container_title Kidney international
container_volume 50
creator Rodby, Roger A.
Firanek, Catherine A.
Cheng, Yong-Gang
Korbet, Stephen M.
description Reproducibility of studies of peritoneal dialysis adequacy. To assess the variability and reproducibility of dialysis adequacy clearance measurements (weekly Kt/V and weekly creatinine clearance/1.73m2 BSA) in a given patient, 42 patients underwent three clearance studies in a one week period. The dialysis prescription was kept constant. There were 21 males with a group mean age of 49 ± 15 years; 37 patients performed CAPD and 5 DAPD; the dialysis prescription was 6 to 12 liters/day; and 17 patients were anuric. To assess test variability within each patient, the coefficient of variation (CV) and the range were determined for each patient's three clearance values, and for the factors that determine those values. These were averaged to determine the mean patient variability (CV and range) of those measurements. The mean patient CV of the weekly Kt/V was 8.1%. The mean patient range of the weekly Kt/V was 0.30. Of the determinants of total Kt/V, the greatest variability (CV) existed in residual renal urea clearance at 35.4%, with moderate variability seen for peritoneal dialysis urea clearance at 7.0%, which was more a function of variability in D/P urea (CV = 6.3%) than variability in drain volume (CV = 4.1%). There was little variability in V (CV = 0.6%). Similar results were seen for the variability in weekly creatinine clearance measurements. We found that the day-to-day reproducibility of Kt/V measurements is limited, especially in patients with residual renal function, although day-to-day variability in D/P urea also affects Kt/V reproducibility in all patients. Values that fall into the borderline “adequate” range may need to be repeated when considering a patient's dialysis prescription. In addition, research that involves the measurement of Kt/V should utilize more than one collection to increase the reliability of those measurements.
doi_str_mv 10.1038/ki.1996.311
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_78326512</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0085253815596051</els_id><sourcerecordid>78326512</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-c6b794e3e34ddd5852da901bb5cdcedcf6dbefb04f0f00f97ef3fe5bf7e2371a3</originalsourceid><addsrcrecordid>eNptkE1LxDAQhoMo67p68izuQbxI16Rp-uFNFr9gQRA9hzSZwLjddk1aof_elJY9eZoM78PM5CHkktEVozy_3-KKFUW64owdkTkTMY9YJsQxmVOaiygWPD8lZ95_09AXnM7ILM9pJopsTh4-YO8a02ksscK2XzZ26dvOIPjhuQeHbVODqpYGVdV79Etl4KdTuj8nJ1ZVHi6muiBfz0-f69do8_7ytn7cRDqJaRvptMyKBDjwxBgjchEbVVBWlkIbDUbb1JRgS5pYaim1RQaWWxClzSDmGVN8QW7HueHQnw58K3foNVSVqqHpvMxyHqeCxQG8G0HtGu8dWLl3uFOul4zKwZTcohxMyWAq0FfT2K7cgTmwk5qQ30y58lpV1qlaoz9gnPFBbMCuR6xWbefgkG9x2DQuEiMBQdIvgpNeI9Th7-hAt9I0-O-Bf7odjqk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>78326512</pqid></control><display><type>article</type><title>Reproducibility of studies of peritoneal dialysis adequacy</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Rodby, Roger A. ; Firanek, Catherine A. ; Cheng, Yong-Gang ; Korbet, Stephen M.</creator><creatorcontrib>Rodby, Roger A. ; Firanek, Catherine A. ; Cheng, Yong-Gang ; Korbet, Stephen M.</creatorcontrib><description>Reproducibility of studies of peritoneal dialysis adequacy. To assess the variability and reproducibility of dialysis adequacy clearance measurements (weekly Kt/V and weekly creatinine clearance/1.73m2 BSA) in a given patient, 42 patients underwent three clearance studies in a one week period. The dialysis prescription was kept constant. There were 21 males with a group mean age of 49 ± 15 years; 37 patients performed CAPD and 5 DAPD; the dialysis prescription was 6 to 12 liters/day; and 17 patients were anuric. To assess test variability within each patient, the coefficient of variation (CV) and the range were determined for each patient's three clearance values, and for the factors that determine those values. These were averaged to determine the mean patient variability (CV and range) of those measurements. The mean patient CV of the weekly Kt/V was 8.1%. The mean patient range of the weekly Kt/V was 0.30. Of the determinants of total Kt/V, the greatest variability (CV) existed in residual renal urea clearance at 35.4%, with moderate variability seen for peritoneal dialysis urea clearance at 7.0%, which was more a function of variability in D/P urea (CV = 6.3%) than variability in drain volume (CV = 4.1%). There was little variability in V (CV = 0.6%). Similar results were seen for the variability in weekly creatinine clearance measurements. We found that the day-to-day reproducibility of Kt/V measurements is limited, especially in patients with residual renal function, although day-to-day variability in D/P urea also affects Kt/V reproducibility in all patients. Values that fall into the borderline “adequate” range may need to be repeated when considering a patient's dialysis prescription. In addition, research that involves the measurement of Kt/V should utilize more than one collection to increase the reliability of those measurements.</description><identifier>ISSN: 0085-2538</identifier><identifier>EISSN: 1523-1755</identifier><identifier>DOI: 10.1038/ki.1996.311</identifier><identifier>PMID: 8807597</identifier><identifier>CODEN: KDYIA5</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Adult ; Aged ; Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Biological and medical sciences ; Creatinine - pharmacokinetics ; Emergency and intensive care: renal failure. Dialysis management ; Female ; Humans ; Intensive care medicine ; Male ; Medical sciences ; Middle Aged ; Peritoneal Dialysis ; Reproducibility of Results</subject><ispartof>Kidney international, 1996-07, Vol.50 (1), p.267-271</ispartof><rights>1996 International Society of Nephrology</rights><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c420t-c6b794e3e34ddd5852da901bb5cdcedcf6dbefb04f0f00f97ef3fe5bf7e2371a3</citedby><cites>FETCH-LOGICAL-c420t-c6b794e3e34ddd5852da901bb5cdcedcf6dbefb04f0f00f97ef3fe5bf7e2371a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3132538$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8807597$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rodby, Roger A.</creatorcontrib><creatorcontrib>Firanek, Catherine A.</creatorcontrib><creatorcontrib>Cheng, Yong-Gang</creatorcontrib><creatorcontrib>Korbet, Stephen M.</creatorcontrib><title>Reproducibility of studies of peritoneal dialysis adequacy</title><title>Kidney international</title><addtitle>Kidney Int</addtitle><description>Reproducibility of studies of peritoneal dialysis adequacy. To assess the variability and reproducibility of dialysis adequacy clearance measurements (weekly Kt/V and weekly creatinine clearance/1.73m2 BSA) in a given patient, 42 patients underwent three clearance studies in a one week period. The dialysis prescription was kept constant. There were 21 males with a group mean age of 49 ± 15 years; 37 patients performed CAPD and 5 DAPD; the dialysis prescription was 6 to 12 liters/day; and 17 patients were anuric. To assess test variability within each patient, the coefficient of variation (CV) and the range were determined for each patient's three clearance values, and for the factors that determine those values. These were averaged to determine the mean patient variability (CV and range) of those measurements. The mean patient CV of the weekly Kt/V was 8.1%. The mean patient range of the weekly Kt/V was 0.30. Of the determinants of total Kt/V, the greatest variability (CV) existed in residual renal urea clearance at 35.4%, with moderate variability seen for peritoneal dialysis urea clearance at 7.0%, which was more a function of variability in D/P urea (CV = 6.3%) than variability in drain volume (CV = 4.1%). There was little variability in V (CV = 0.6%). Similar results were seen for the variability in weekly creatinine clearance measurements. We found that the day-to-day reproducibility of Kt/V measurements is limited, especially in patients with residual renal function, although day-to-day variability in D/P urea also affects Kt/V reproducibility in all patients. Values that fall into the borderline “adequate” range may need to be repeated when considering a patient's dialysis prescription. In addition, research that involves the measurement of Kt/V should utilize more than one collection to increase the reliability of those measurements.</description><subject>Adult</subject><subject>Aged</subject><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Biological and medical sciences</subject><subject>Creatinine - pharmacokinetics</subject><subject>Emergency and intensive care: renal failure. Dialysis management</subject><subject>Female</subject><subject>Humans</subject><subject>Intensive care medicine</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Peritoneal Dialysis</subject><subject>Reproducibility of Results</subject><issn>0085-2538</issn><issn>1523-1755</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNptkE1LxDAQhoMo67p68izuQbxI16Rp-uFNFr9gQRA9hzSZwLjddk1aof_elJY9eZoM78PM5CHkktEVozy_3-KKFUW64owdkTkTMY9YJsQxmVOaiygWPD8lZ95_09AXnM7ILM9pJopsTh4-YO8a02ksscK2XzZ26dvOIPjhuQeHbVODqpYGVdV79Etl4KdTuj8nJ1ZVHi6muiBfz0-f69do8_7ytn7cRDqJaRvptMyKBDjwxBgjchEbVVBWlkIbDUbb1JRgS5pYaim1RQaWWxClzSDmGVN8QW7HueHQnw58K3foNVSVqqHpvMxyHqeCxQG8G0HtGu8dWLl3uFOul4zKwZTcohxMyWAq0FfT2K7cgTmwk5qQ30y58lpV1qlaoz9gnPFBbMCuR6xWbefgkG9x2DQuEiMBQdIvgpNeI9Th7-hAt9I0-O-Bf7odjqk</recordid><startdate>19960701</startdate><enddate>19960701</enddate><creator>Rodby, Roger A.</creator><creator>Firanek, Catherine A.</creator><creator>Cheng, Yong-Gang</creator><creator>Korbet, Stephen M.</creator><general>Elsevier Inc</general><general>Nature Publishing</general><scope>6I.</scope><scope>AAFTH</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19960701</creationdate><title>Reproducibility of studies of peritoneal dialysis adequacy</title><author>Rodby, Roger A. ; Firanek, Catherine A. ; Cheng, Yong-Gang ; Korbet, Stephen M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-c6b794e3e34ddd5852da901bb5cdcedcf6dbefb04f0f00f97ef3fe5bf7e2371a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Biological and medical sciences</topic><topic>Creatinine - pharmacokinetics</topic><topic>Emergency and intensive care: renal failure. Dialysis management</topic><topic>Female</topic><topic>Humans</topic><topic>Intensive care medicine</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Peritoneal Dialysis</topic><topic>Reproducibility of Results</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rodby, Roger A.</creatorcontrib><creatorcontrib>Firanek, Catherine A.</creatorcontrib><creatorcontrib>Cheng, Yong-Gang</creatorcontrib><creatorcontrib>Korbet, Stephen M.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Kidney international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rodby, Roger A.</au><au>Firanek, Catherine A.</au><au>Cheng, Yong-Gang</au><au>Korbet, Stephen M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reproducibility of studies of peritoneal dialysis adequacy</atitle><jtitle>Kidney international</jtitle><addtitle>Kidney Int</addtitle><date>1996-07-01</date><risdate>1996</risdate><volume>50</volume><issue>1</issue><spage>267</spage><epage>271</epage><pages>267-271</pages><issn>0085-2538</issn><eissn>1523-1755</eissn><coden>KDYIA5</coden><abstract>Reproducibility of studies of peritoneal dialysis adequacy. To assess the variability and reproducibility of dialysis adequacy clearance measurements (weekly Kt/V and weekly creatinine clearance/1.73m2 BSA) in a given patient, 42 patients underwent three clearance studies in a one week period. The dialysis prescription was kept constant. There were 21 males with a group mean age of 49 ± 15 years; 37 patients performed CAPD and 5 DAPD; the dialysis prescription was 6 to 12 liters/day; and 17 patients were anuric. To assess test variability within each patient, the coefficient of variation (CV) and the range were determined for each patient's three clearance values, and for the factors that determine those values. These were averaged to determine the mean patient variability (CV and range) of those measurements. The mean patient CV of the weekly Kt/V was 8.1%. The mean patient range of the weekly Kt/V was 0.30. Of the determinants of total Kt/V, the greatest variability (CV) existed in residual renal urea clearance at 35.4%, with moderate variability seen for peritoneal dialysis urea clearance at 7.0%, which was more a function of variability in D/P urea (CV = 6.3%) than variability in drain volume (CV = 4.1%). There was little variability in V (CV = 0.6%). Similar results were seen for the variability in weekly creatinine clearance measurements. We found that the day-to-day reproducibility of Kt/V measurements is limited, especially in patients with residual renal function, although day-to-day variability in D/P urea also affects Kt/V reproducibility in all patients. Values that fall into the borderline “adequate” range may need to be repeated when considering a patient's dialysis prescription. In addition, research that involves the measurement of Kt/V should utilize more than one collection to increase the reliability of those measurements.</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>8807597</pmid><doi>10.1038/ki.1996.311</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0085-2538
ispartof Kidney international, 1996-07, Vol.50 (1), p.267-271
issn 0085-2538
1523-1755
language eng
recordid cdi_proquest_miscellaneous_78326512
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
subjects Adult
Aged
Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
Biological and medical sciences
Creatinine - pharmacokinetics
Emergency and intensive care: renal failure. Dialysis management
Female
Humans
Intensive care medicine
Male
Medical sciences
Middle Aged
Peritoneal Dialysis
Reproducibility of Results
title Reproducibility of studies of peritoneal dialysis adequacy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T18%3A41%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reproducibility%20of%20studies%20of%20peritoneal%20dialysis%20adequacy&rft.jtitle=Kidney%20international&rft.au=Rodby,%20Roger%20A.&rft.date=1996-07-01&rft.volume=50&rft.issue=1&rft.spage=267&rft.epage=271&rft.pages=267-271&rft.issn=0085-2538&rft.eissn=1523-1755&rft.coden=KDYIA5&rft_id=info:doi/10.1038/ki.1996.311&rft_dat=%3Cproquest_cross%3E78326512%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=78326512&rft_id=info:pmid/8807597&rft_els_id=S0085253815596051&rfr_iscdi=true