Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease

This study was undertaken to evaluate whether adenosine echocardiography is comparable to exercise echocardiography in the detection of ischemia in patients with suspected coronary artery disease and to assess whether the addition of handgrip exercise to adenosine enhances the induction of ischemia...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American Society of Echocardiography 1996, Vol.9 (1), p.33-43
Hauptverfasser: Tawa, Cyril B., Baker, William B., Kleiman, Neal S., Trakhtenbroit, Anatole, Desir, Ranley, Zoghbi, William A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 43
container_issue 1
container_start_page 33
container_title Journal of the American Society of Echocardiography
container_volume 9
creator Tawa, Cyril B.
Baker, William B.
Kleiman, Neal S.
Trakhtenbroit, Anatole
Desir, Ranley
Zoghbi, William A.
description This study was undertaken to evaluate whether adenosine echocardiography is comparable to exercise echocardiography in the detection of ischemia in patients with suspected coronary artery disease and to assess whether the addition of handgrip exercise to adenosine enhances the induction of ischemia in these patients. Accordingly, 67 patients with suspected or known coronary artery disease referred for exercise testing underwent adenosine, adenosine with handgrip, and post-treadmill exercise echocardiography. A maximal adenosine infusion dose of 170 μg/kg/min was used. Images at baseline and during each of the three stress modalities were digitized in a quad-screen format, randomized, and blinded as to the stage and mode of intervention for nonbiased interpretation. An ischemic response was defined as a new or worsening wall motion abnormality. Ischemia was detected by exercise echocardiography ( n = 20) more often than by adenosine echocardiography alone ( n = 11; p = 0.039) but similarly to adenosine plus handgrip ( n = 16; difference not significant). Exact agreement in individual response between exercise and adenosine echocardiography was seen in 51 (80%) of 64 patients and increased to 88% between exercise and adenosine plus handgrip. In the patients who underwent angiography ( n = 45), the sensitivity for coronary artery disease ( n = 33) was 87% for adenosine, 91% for adenosine plus handgrip, and 93% for exercise echocardiography. The respective sensitivities decreased to 64%, 81%, and 89% in patients without previous myocardial infarction. Specificity was 91% for adenosine with or without handgrip and 82% for exercise echocardiography. Image quality during adenosine with and without handgrip was superior to that during exercise ( p < 0.01). Thus in patients with coronary artery disease able to exercise, exercise echocardiography induces ischemia more frequently than does adenosine echocardiography alone. The addition of handgrip exercise to adenosine infusion enhances the detection of ischemia without reducing specificity or image quality and is recommended when adenosine echocardiography is used as a pharmacologic stress test.
doi_str_mv 10.1016/S0894-7317(96)90102-9
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_78127679</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0894731796901029</els_id><sourcerecordid>78127679</sourcerecordid><originalsourceid>FETCH-LOGICAL-e177t-a8443ede9bb2d5fbae2a8772cfc992ca28dcef64d6869917a7f28cf4f9c24fce3</originalsourceid><addsrcrecordid>eNplUV1vFCEUJUZTt9Wf0ISnRpOOBWZ2gCdjNtaaNPHB-kzuwqWD2RmmwFb7s_yHZT_iS58u4RzOPZxDyDlnnzjj_dVPpnTXyJbLD7r_qBlnotGvyIIzLZte6uVrsvhPeUtOc_7NGFsqxk7IiaoE0S4X5N8qjjOkkONEo6fgcIo5TEjRDtFCciHeJ5iHp0v6J5SBwuT2h7gttD4asaRg6VCv71OYL2mJFP9isiG_lKBhomVA6rCgLeGwMWQ74BhgB85QAk4lH1bZmOIE6YlCKliHq5qQ8R1542GT8f1xnpFf11_vVjfN7Y9v31dfbhvkUpYGVNe16FCv18It_RpQgJJSWG-1FhaEchZ937le9VpzCdILZX3ntRWdt9iekYuD7pziwxZzMWP1ipsNTBi32UjFhawxVuL5kbhdj-jMnMJYbZtjxhX_fMCxun0MmEy29ZsWXUg1B-NiMJyZXalmX6rZNWZ0b_alGt0-Ay7YmiE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>78127679</pqid></control><display><type>article</type><title>Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Tawa, Cyril B. ; Baker, William B. ; Kleiman, Neal S. ; Trakhtenbroit, Anatole ; Desir, Ranley ; Zoghbi, William A.</creator><creatorcontrib>Tawa, Cyril B. ; Baker, William B. ; Kleiman, Neal S. ; Trakhtenbroit, Anatole ; Desir, Ranley ; Zoghbi, William A.</creatorcontrib><description>This study was undertaken to evaluate whether adenosine echocardiography is comparable to exercise echocardiography in the detection of ischemia in patients with suspected coronary artery disease and to assess whether the addition of handgrip exercise to adenosine enhances the induction of ischemia in these patients. Accordingly, 67 patients with suspected or known coronary artery disease referred for exercise testing underwent adenosine, adenosine with handgrip, and post-treadmill exercise echocardiography. A maximal adenosine infusion dose of 170 μg/kg/min was used. Images at baseline and during each of the three stress modalities were digitized in a quad-screen format, randomized, and blinded as to the stage and mode of intervention for nonbiased interpretation. An ischemic response was defined as a new or worsening wall motion abnormality. Ischemia was detected by exercise echocardiography ( n = 20) more often than by adenosine echocardiography alone ( n = 11; p = 0.039) but similarly to adenosine plus handgrip ( n = 16; difference not significant). Exact agreement in individual response between exercise and adenosine echocardiography was seen in 51 (80%) of 64 patients and increased to 88% between exercise and adenosine plus handgrip. In the patients who underwent angiography ( n = 45), the sensitivity for coronary artery disease ( n = 33) was 87% for adenosine, 91% for adenosine plus handgrip, and 93% for exercise echocardiography. The respective sensitivities decreased to 64%, 81%, and 89% in patients without previous myocardial infarction. Specificity was 91% for adenosine with or without handgrip and 82% for exercise echocardiography. Image quality during adenosine with and without handgrip was superior to that during exercise ( p &lt; 0.01). Thus in patients with coronary artery disease able to exercise, exercise echocardiography induces ischemia more frequently than does adenosine echocardiography alone. The addition of handgrip exercise to adenosine infusion enhances the detection of ischemia without reducing specificity or image quality and is recommended when adenosine echocardiography is used as a pharmacologic stress test.</description><identifier>ISSN: 0894-7317</identifier><identifier>EISSN: 1097-6795</identifier><identifier>DOI: 10.1016/S0894-7317(96)90102-9</identifier><identifier>PMID: 8679235</identifier><language>eng</language><publisher>United States: Mosby, Inc</publisher><subject>Adenosine ; Cardiovascular Agents ; Coronary Angiography ; Coronary Disease - diagnostic imaging ; Echocardiography ; Exercise Test ; Female ; Hand - physiology ; Humans ; Image Enhancement ; Image Processing, Computer-Assisted ; Infusions, Intravenous ; Isometric Contraction ; Male ; Middle Aged ; Myocardial Ischemia - diagnostic imaging ; Physical Exertion ; Prospective Studies ; Sensitivity and Specificity ; Single-Blind Method ; Space life sciences</subject><ispartof>Journal of the American Society of Echocardiography, 1996, Vol.9 (1), p.33-43</ispartof><rights>1996</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0894-7317(96)90102-9$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,4024,27923,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8679235$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tawa, Cyril B.</creatorcontrib><creatorcontrib>Baker, William B.</creatorcontrib><creatorcontrib>Kleiman, Neal S.</creatorcontrib><creatorcontrib>Trakhtenbroit, Anatole</creatorcontrib><creatorcontrib>Desir, Ranley</creatorcontrib><creatorcontrib>Zoghbi, William A.</creatorcontrib><title>Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease</title><title>Journal of the American Society of Echocardiography</title><addtitle>J Am Soc Echocardiogr</addtitle><description>This study was undertaken to evaluate whether adenosine echocardiography is comparable to exercise echocardiography in the detection of ischemia in patients with suspected coronary artery disease and to assess whether the addition of handgrip exercise to adenosine enhances the induction of ischemia in these patients. Accordingly, 67 patients with suspected or known coronary artery disease referred for exercise testing underwent adenosine, adenosine with handgrip, and post-treadmill exercise echocardiography. A maximal adenosine infusion dose of 170 μg/kg/min was used. Images at baseline and during each of the three stress modalities were digitized in a quad-screen format, randomized, and blinded as to the stage and mode of intervention for nonbiased interpretation. An ischemic response was defined as a new or worsening wall motion abnormality. Ischemia was detected by exercise echocardiography ( n = 20) more often than by adenosine echocardiography alone ( n = 11; p = 0.039) but similarly to adenosine plus handgrip ( n = 16; difference not significant). Exact agreement in individual response between exercise and adenosine echocardiography was seen in 51 (80%) of 64 patients and increased to 88% between exercise and adenosine plus handgrip. In the patients who underwent angiography ( n = 45), the sensitivity for coronary artery disease ( n = 33) was 87% for adenosine, 91% for adenosine plus handgrip, and 93% for exercise echocardiography. The respective sensitivities decreased to 64%, 81%, and 89% in patients without previous myocardial infarction. Specificity was 91% for adenosine with or without handgrip and 82% for exercise echocardiography. Image quality during adenosine with and without handgrip was superior to that during exercise ( p &lt; 0.01). Thus in patients with coronary artery disease able to exercise, exercise echocardiography induces ischemia more frequently than does adenosine echocardiography alone. The addition of handgrip exercise to adenosine infusion enhances the detection of ischemia without reducing specificity or image quality and is recommended when adenosine echocardiography is used as a pharmacologic stress test.</description><subject>Adenosine</subject><subject>Cardiovascular Agents</subject><subject>Coronary Angiography</subject><subject>Coronary Disease - diagnostic imaging</subject><subject>Echocardiography</subject><subject>Exercise Test</subject><subject>Female</subject><subject>Hand - physiology</subject><subject>Humans</subject><subject>Image Enhancement</subject><subject>Image Processing, Computer-Assisted</subject><subject>Infusions, Intravenous</subject><subject>Isometric Contraction</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Myocardial Ischemia - diagnostic imaging</subject><subject>Physical Exertion</subject><subject>Prospective Studies</subject><subject>Sensitivity and Specificity</subject><subject>Single-Blind Method</subject><subject>Space life sciences</subject><issn>0894-7317</issn><issn>1097-6795</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNplUV1vFCEUJUZTt9Wf0ISnRpOOBWZ2gCdjNtaaNPHB-kzuwqWD2RmmwFb7s_yHZT_iS58u4RzOPZxDyDlnnzjj_dVPpnTXyJbLD7r_qBlnotGvyIIzLZte6uVrsvhPeUtOc_7NGFsqxk7IiaoE0S4X5N8qjjOkkONEo6fgcIo5TEjRDtFCciHeJ5iHp0v6J5SBwuT2h7gttD4asaRg6VCv71OYL2mJFP9isiG_lKBhomVA6rCgLeGwMWQ74BhgB85QAk4lH1bZmOIE6YlCKliHq5qQ8R1542GT8f1xnpFf11_vVjfN7Y9v31dfbhvkUpYGVNe16FCv18It_RpQgJJSWG-1FhaEchZ937le9VpzCdILZX3ntRWdt9iekYuD7pziwxZzMWP1ipsNTBi32UjFhawxVuL5kbhdj-jMnMJYbZtjxhX_fMCxun0MmEy29ZsWXUg1B-NiMJyZXalmX6rZNWZ0b_alGt0-Ay7YmiE</recordid><startdate>1996</startdate><enddate>1996</enddate><creator>Tawa, Cyril B.</creator><creator>Baker, William B.</creator><creator>Kleiman, Neal S.</creator><creator>Trakhtenbroit, Anatole</creator><creator>Desir, Ranley</creator><creator>Zoghbi, William A.</creator><general>Mosby, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>1996</creationdate><title>Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease</title><author>Tawa, Cyril B. ; Baker, William B. ; Kleiman, Neal S. ; Trakhtenbroit, Anatole ; Desir, Ranley ; Zoghbi, William A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-e177t-a8443ede9bb2d5fbae2a8772cfc992ca28dcef64d6869917a7f28cf4f9c24fce3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Adenosine</topic><topic>Cardiovascular Agents</topic><topic>Coronary Angiography</topic><topic>Coronary Disease - diagnostic imaging</topic><topic>Echocardiography</topic><topic>Exercise Test</topic><topic>Female</topic><topic>Hand - physiology</topic><topic>Humans</topic><topic>Image Enhancement</topic><topic>Image Processing, Computer-Assisted</topic><topic>Infusions, Intravenous</topic><topic>Isometric Contraction</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Myocardial Ischemia - diagnostic imaging</topic><topic>Physical Exertion</topic><topic>Prospective Studies</topic><topic>Sensitivity and Specificity</topic><topic>Single-Blind Method</topic><topic>Space life sciences</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tawa, Cyril B.</creatorcontrib><creatorcontrib>Baker, William B.</creatorcontrib><creatorcontrib>Kleiman, Neal S.</creatorcontrib><creatorcontrib>Trakhtenbroit, Anatole</creatorcontrib><creatorcontrib>Desir, Ranley</creatorcontrib><creatorcontrib>Zoghbi, William A.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Society of Echocardiography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tawa, Cyril B.</au><au>Baker, William B.</au><au>Kleiman, Neal S.</au><au>Trakhtenbroit, Anatole</au><au>Desir, Ranley</au><au>Zoghbi, William A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease</atitle><jtitle>Journal of the American Society of Echocardiography</jtitle><addtitle>J Am Soc Echocardiogr</addtitle><date>1996</date><risdate>1996</risdate><volume>9</volume><issue>1</issue><spage>33</spage><epage>43</epage><pages>33-43</pages><issn>0894-7317</issn><eissn>1097-6795</eissn><abstract>This study was undertaken to evaluate whether adenosine echocardiography is comparable to exercise echocardiography in the detection of ischemia in patients with suspected coronary artery disease and to assess whether the addition of handgrip exercise to adenosine enhances the induction of ischemia in these patients. Accordingly, 67 patients with suspected or known coronary artery disease referred for exercise testing underwent adenosine, adenosine with handgrip, and post-treadmill exercise echocardiography. A maximal adenosine infusion dose of 170 μg/kg/min was used. Images at baseline and during each of the three stress modalities were digitized in a quad-screen format, randomized, and blinded as to the stage and mode of intervention for nonbiased interpretation. An ischemic response was defined as a new or worsening wall motion abnormality. Ischemia was detected by exercise echocardiography ( n = 20) more often than by adenosine echocardiography alone ( n = 11; p = 0.039) but similarly to adenosine plus handgrip ( n = 16; difference not significant). Exact agreement in individual response between exercise and adenosine echocardiography was seen in 51 (80%) of 64 patients and increased to 88% between exercise and adenosine plus handgrip. In the patients who underwent angiography ( n = 45), the sensitivity for coronary artery disease ( n = 33) was 87% for adenosine, 91% for adenosine plus handgrip, and 93% for exercise echocardiography. The respective sensitivities decreased to 64%, 81%, and 89% in patients without previous myocardial infarction. Specificity was 91% for adenosine with or without handgrip and 82% for exercise echocardiography. Image quality during adenosine with and without handgrip was superior to that during exercise ( p &lt; 0.01). Thus in patients with coronary artery disease able to exercise, exercise echocardiography induces ischemia more frequently than does adenosine echocardiography alone. The addition of handgrip exercise to adenosine infusion enhances the detection of ischemia without reducing specificity or image quality and is recommended when adenosine echocardiography is used as a pharmacologic stress test.</abstract><cop>United States</cop><pub>Mosby, Inc</pub><pmid>8679235</pmid><doi>10.1016/S0894-7317(96)90102-9</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0894-7317
ispartof Journal of the American Society of Echocardiography, 1996, Vol.9 (1), p.33-43
issn 0894-7317
1097-6795
language eng
recordid cdi_proquest_miscellaneous_78127679
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Adenosine
Cardiovascular Agents
Coronary Angiography
Coronary Disease - diagnostic imaging
Echocardiography
Exercise Test
Female
Hand - physiology
Humans
Image Enhancement
Image Processing, Computer-Assisted
Infusions, Intravenous
Isometric Contraction
Male
Middle Aged
Myocardial Ischemia - diagnostic imaging
Physical Exertion
Prospective Studies
Sensitivity and Specificity
Single-Blind Method
Space life sciences
title Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T03%3A45%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20adenosine%20echocardiography,%20with%20and%20without%20isometric%20handgrip,%20to%20exercise%20echocardiography%20in%20the%20detection%20of%20ischemia%20in%20patients%20with%20coronary%20artery%20disease&rft.jtitle=Journal%20of%20the%20American%20Society%20of%20Echocardiography&rft.au=Tawa,%20Cyril%20B.&rft.date=1996&rft.volume=9&rft.issue=1&rft.spage=33&rft.epage=43&rft.pages=33-43&rft.issn=0894-7317&rft.eissn=1097-6795&rft_id=info:doi/10.1016/S0894-7317(96)90102-9&rft_dat=%3Cproquest_pubme%3E78127679%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=78127679&rft_id=info:pmid/8679235&rft_els_id=S0894731796901029&rfr_iscdi=true