In vivo PO2 imaging in the porcine model with perfluorocarbon F-19 NMR at low field

Quantitative pO2 imaging in vivo has been evaluated utilizing F-19 NMR in the porcine model at 0.14 T for the lungs, liver, and spleen following i.p. administration of the commercial perfluorotributylamine (FC-43)-based perfluorocarbon (PFC) emulsion, Oxypherol-ET. Calculated T1 maps obtained from a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance imaging 1996, Vol.14 (1), p.103-114
Hauptverfasser: THOMAS, S. R, PRATT, R. G, MILLARD, R. W, SAMARATUNGA, R. C, SHIFERAW, Y, MCGORON, A. J, KIM KIAT TAN
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 114
container_issue 1
container_start_page 103
container_title Magnetic resonance imaging
container_volume 14
creator THOMAS, S. R
PRATT, R. G
MILLARD, R. W
SAMARATUNGA, R. C
SHIFERAW, Y
MCGORON, A. J
KIM KIAT TAN
description Quantitative pO2 imaging in vivo has been evaluated utilizing F-19 NMR in the porcine model at 0.14 T for the lungs, liver, and spleen following i.p. administration of the commercial perfluorotributylamine (FC-43)-based perfluorocarbon (PFC) emulsion, Oxypherol-ET. Calculated T1 maps obtained from a two spin-echo saturation recovery/inversion recovery (SR/IR) pulse protocol are converted into quantitative pO2 images through a temperature-dependent calibration curve relating longitudinal relaxation rate (1/T1) to pO2. The uncertainty in pO2 for a T1 measurement error of +/- 5% as encountered in establishing the calibration curves ranges from +/- 10 torr (+/- 40%) at 25 torr to +/- 16 torr (+/- 11%) at 150 torr for FC-43 (37 degrees C). However, additional uncertainties in T1 dependent upon the signal-to-noise ratio may be introduced through the SR/IR calculated T1 pulse protocol, which might severely degrade the pO2 accuracy. Correlation of the organ image calculated pO2 with directly measured pO2 in airway or blood pools in six pigs indicate that the PFC resident in lung is in near equilibrium with arterialized blood and not with airway pO2, suggesting a location distal to the alveolar epithelium. For the liver, the strongest correlation implying equilibrium was evident for venous blood (hepatic vein). For the spleen, arterial blood pO2 (aorta) was an unreliable predictor of pO2 for PFC resident in splenic tissue. The results have demonstrated the utility and defined the limiting aspects quantitative pO2 imaging in vivo using F-19 MRI of sequestered PFC materials.
doi_str_mv 10.1016/0730-725X(95)02046-V
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_78062672</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>78062672</sourcerecordid><originalsourceid>FETCH-LOGICAL-c246t-b1011da4201c6493904e40e78abb4dce355bdab9fc1e65bd8c65771c76d53e093</originalsourceid><addsrcrecordid>eNo9kNlKxDAUhoMoOi5voJALEb2onuzNpQxu4IYb3oU0TTXSacako_j2dnSYq3PgX-D_ENolcEyAyBNQDApFxeuhFkdAgcviZQWNSKlYIUrNV9FoadlAmzl_AICgTKyj9VIKqUs6Qo9XHf4KXxHf31EcJvYtdG84dLh_93gakwudx5NY-xZ_h_4dT31q2llM0dlUxQ6fF0Tj25sHbHvcxm_cBN_W22itsW32O4u7hZ7Pz57Gl8X13cXV-PS6cJTLvqiGFaS2nAJxkmumgXsOXpW2qnjtPBOiqm2lG0e8HN7SSaEUcUrWgnnQbAsd_PdOU_yc-dybScjOt63tfJxlo0qQVCo6GPm_0aWYc_KNmaZha_oxBMycpZmDMnNQRgvzx9K8DLG9Rf-smvh6GVrAG_T9hW6zs22TbOdCXtoYEAAt2S9I-nq7</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>78062672</pqid></control><display><type>article</type><title>In vivo PO2 imaging in the porcine model with perfluorocarbon F-19 NMR at low field</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>THOMAS, S. R ; PRATT, R. G ; MILLARD, R. W ; SAMARATUNGA, R. C ; SHIFERAW, Y ; MCGORON, A. J ; KIM KIAT TAN</creator><creatorcontrib>THOMAS, S. R ; PRATT, R. G ; MILLARD, R. W ; SAMARATUNGA, R. C ; SHIFERAW, Y ; MCGORON, A. J ; KIM KIAT TAN</creatorcontrib><description>Quantitative pO2 imaging in vivo has been evaluated utilizing F-19 NMR in the porcine model at 0.14 T for the lungs, liver, and spleen following i.p. administration of the commercial perfluorotributylamine (FC-43)-based perfluorocarbon (PFC) emulsion, Oxypherol-ET. Calculated T1 maps obtained from a two spin-echo saturation recovery/inversion recovery (SR/IR) pulse protocol are converted into quantitative pO2 images through a temperature-dependent calibration curve relating longitudinal relaxation rate (1/T1) to pO2. The uncertainty in pO2 for a T1 measurement error of +/- 5% as encountered in establishing the calibration curves ranges from +/- 10 torr (+/- 40%) at 25 torr to +/- 16 torr (+/- 11%) at 150 torr for FC-43 (37 degrees C). However, additional uncertainties in T1 dependent upon the signal-to-noise ratio may be introduced through the SR/IR calculated T1 pulse protocol, which might severely degrade the pO2 accuracy. Correlation of the organ image calculated pO2 with directly measured pO2 in airway or blood pools in six pigs indicate that the PFC resident in lung is in near equilibrium with arterialized blood and not with airway pO2, suggesting a location distal to the alveolar epithelium. For the liver, the strongest correlation implying equilibrium was evident for venous blood (hepatic vein). For the spleen, arterial blood pO2 (aorta) was an unreliable predictor of pO2 for PFC resident in splenic tissue. The results have demonstrated the utility and defined the limiting aspects quantitative pO2 imaging in vivo using F-19 MRI of sequestered PFC materials.</description><identifier>ISSN: 0730-725X</identifier><identifier>EISSN: 1873-5894</identifier><identifier>DOI: 10.1016/0730-725X(95)02046-V</identifier><identifier>PMID: 8656982</identifier><identifier>CODEN: MRIMDQ</identifier><language>eng</language><publisher>New York, NY: Elsevier Science</publisher><subject>Animals ; Biological and medical sciences ; Blood Substitutes - administration &amp; dosage ; Female ; Fluorocarbons - administration &amp; dosage ; Investigative techniques, diagnostic techniques (general aspects) ; Liver - chemistry ; Lung - chemistry ; Magnetic Resonance Spectroscopy - methods ; Medical sciences ; Miscellaneous. Technology ; Oxygen - analysis ; Oxygen - blood ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Respiration ; Spleen - chemistry ; Swine</subject><ispartof>Magnetic resonance imaging, 1996, Vol.14 (1), p.103-114</ispartof><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c246t-b1011da4201c6493904e40e78abb4dce355bdab9fc1e65bd8c65771c76d53e093</citedby><cites>FETCH-LOGICAL-c246t-b1011da4201c6493904e40e78abb4dce355bdab9fc1e65bd8c65771c76d53e093</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3010096$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8656982$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>THOMAS, S. R</creatorcontrib><creatorcontrib>PRATT, R. G</creatorcontrib><creatorcontrib>MILLARD, R. W</creatorcontrib><creatorcontrib>SAMARATUNGA, R. C</creatorcontrib><creatorcontrib>SHIFERAW, Y</creatorcontrib><creatorcontrib>MCGORON, A. J</creatorcontrib><creatorcontrib>KIM KIAT TAN</creatorcontrib><title>In vivo PO2 imaging in the porcine model with perfluorocarbon F-19 NMR at low field</title><title>Magnetic resonance imaging</title><addtitle>Magn Reson Imaging</addtitle><description>Quantitative pO2 imaging in vivo has been evaluated utilizing F-19 NMR in the porcine model at 0.14 T for the lungs, liver, and spleen following i.p. administration of the commercial perfluorotributylamine (FC-43)-based perfluorocarbon (PFC) emulsion, Oxypherol-ET. Calculated T1 maps obtained from a two spin-echo saturation recovery/inversion recovery (SR/IR) pulse protocol are converted into quantitative pO2 images through a temperature-dependent calibration curve relating longitudinal relaxation rate (1/T1) to pO2. The uncertainty in pO2 for a T1 measurement error of +/- 5% as encountered in establishing the calibration curves ranges from +/- 10 torr (+/- 40%) at 25 torr to +/- 16 torr (+/- 11%) at 150 torr for FC-43 (37 degrees C). However, additional uncertainties in T1 dependent upon the signal-to-noise ratio may be introduced through the SR/IR calculated T1 pulse protocol, which might severely degrade the pO2 accuracy. Correlation of the organ image calculated pO2 with directly measured pO2 in airway or blood pools in six pigs indicate that the PFC resident in lung is in near equilibrium with arterialized blood and not with airway pO2, suggesting a location distal to the alveolar epithelium. For the liver, the strongest correlation implying equilibrium was evident for venous blood (hepatic vein). For the spleen, arterial blood pO2 (aorta) was an unreliable predictor of pO2 for PFC resident in splenic tissue. The results have demonstrated the utility and defined the limiting aspects quantitative pO2 imaging in vivo using F-19 MRI of sequestered PFC materials.</description><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Blood Substitutes - administration &amp; dosage</subject><subject>Female</subject><subject>Fluorocarbons - administration &amp; dosage</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Liver - chemistry</subject><subject>Lung - chemistry</subject><subject>Magnetic Resonance Spectroscopy - methods</subject><subject>Medical sciences</subject><subject>Miscellaneous. Technology</subject><subject>Oxygen - analysis</subject><subject>Oxygen - blood</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Respiration</subject><subject>Spleen - chemistry</subject><subject>Swine</subject><issn>0730-725X</issn><issn>1873-5894</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kNlKxDAUhoMoOi5voJALEb2onuzNpQxu4IYb3oU0TTXSacako_j2dnSYq3PgX-D_ENolcEyAyBNQDApFxeuhFkdAgcviZQWNSKlYIUrNV9FoadlAmzl_AICgTKyj9VIKqUs6Qo9XHf4KXxHf31EcJvYtdG84dLh_93gakwudx5NY-xZ_h_4dT31q2llM0dlUxQ6fF0Tj25sHbHvcxm_cBN_W22itsW32O4u7hZ7Pz57Gl8X13cXV-PS6cJTLvqiGFaS2nAJxkmumgXsOXpW2qnjtPBOiqm2lG0e8HN7SSaEUcUrWgnnQbAsd_PdOU_yc-dybScjOt63tfJxlo0qQVCo6GPm_0aWYc_KNmaZha_oxBMycpZmDMnNQRgvzx9K8DLG9Rf-smvh6GVrAG_T9hW6zs22TbOdCXtoYEAAt2S9I-nq7</recordid><startdate>1996</startdate><enddate>1996</enddate><creator>THOMAS, S. R</creator><creator>PRATT, R. G</creator><creator>MILLARD, R. W</creator><creator>SAMARATUNGA, R. C</creator><creator>SHIFERAW, Y</creator><creator>MCGORON, A. J</creator><creator>KIM KIAT TAN</creator><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1996</creationdate><title>In vivo PO2 imaging in the porcine model with perfluorocarbon F-19 NMR at low field</title><author>THOMAS, S. R ; PRATT, R. G ; MILLARD, R. W ; SAMARATUNGA, R. C ; SHIFERAW, Y ; MCGORON, A. J ; KIM KIAT TAN</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c246t-b1011da4201c6493904e40e78abb4dce355bdab9fc1e65bd8c65771c76d53e093</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Blood Substitutes - administration &amp; dosage</topic><topic>Female</topic><topic>Fluorocarbons - administration &amp; dosage</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Liver - chemistry</topic><topic>Lung - chemistry</topic><topic>Magnetic Resonance Spectroscopy - methods</topic><topic>Medical sciences</topic><topic>Miscellaneous. Technology</topic><topic>Oxygen - analysis</topic><topic>Oxygen - blood</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Respiration</topic><topic>Spleen - chemistry</topic><topic>Swine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>THOMAS, S. R</creatorcontrib><creatorcontrib>PRATT, R. G</creatorcontrib><creatorcontrib>MILLARD, R. W</creatorcontrib><creatorcontrib>SAMARATUNGA, R. C</creatorcontrib><creatorcontrib>SHIFERAW, Y</creatorcontrib><creatorcontrib>MCGORON, A. J</creatorcontrib><creatorcontrib>KIM KIAT TAN</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Magnetic resonance imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>THOMAS, S. R</au><au>PRATT, R. G</au><au>MILLARD, R. W</au><au>SAMARATUNGA, R. C</au><au>SHIFERAW, Y</au><au>MCGORON, A. J</au><au>KIM KIAT TAN</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In vivo PO2 imaging in the porcine model with perfluorocarbon F-19 NMR at low field</atitle><jtitle>Magnetic resonance imaging</jtitle><addtitle>Magn Reson Imaging</addtitle><date>1996</date><risdate>1996</risdate><volume>14</volume><issue>1</issue><spage>103</spage><epage>114</epage><pages>103-114</pages><issn>0730-725X</issn><eissn>1873-5894</eissn><coden>MRIMDQ</coden><abstract>Quantitative pO2 imaging in vivo has been evaluated utilizing F-19 NMR in the porcine model at 0.14 T for the lungs, liver, and spleen following i.p. administration of the commercial perfluorotributylamine (FC-43)-based perfluorocarbon (PFC) emulsion, Oxypherol-ET. Calculated T1 maps obtained from a two spin-echo saturation recovery/inversion recovery (SR/IR) pulse protocol are converted into quantitative pO2 images through a temperature-dependent calibration curve relating longitudinal relaxation rate (1/T1) to pO2. The uncertainty in pO2 for a T1 measurement error of +/- 5% as encountered in establishing the calibration curves ranges from +/- 10 torr (+/- 40%) at 25 torr to +/- 16 torr (+/- 11%) at 150 torr for FC-43 (37 degrees C). However, additional uncertainties in T1 dependent upon the signal-to-noise ratio may be introduced through the SR/IR calculated T1 pulse protocol, which might severely degrade the pO2 accuracy. Correlation of the organ image calculated pO2 with directly measured pO2 in airway or blood pools in six pigs indicate that the PFC resident in lung is in near equilibrium with arterialized blood and not with airway pO2, suggesting a location distal to the alveolar epithelium. For the liver, the strongest correlation implying equilibrium was evident for venous blood (hepatic vein). For the spleen, arterial blood pO2 (aorta) was an unreliable predictor of pO2 for PFC resident in splenic tissue. The results have demonstrated the utility and defined the limiting aspects quantitative pO2 imaging in vivo using F-19 MRI of sequestered PFC materials.</abstract><cop>New York, NY</cop><pub>Elsevier Science</pub><pmid>8656982</pmid><doi>10.1016/0730-725X(95)02046-V</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0730-725X
ispartof Magnetic resonance imaging, 1996, Vol.14 (1), p.103-114
issn 0730-725X
1873-5894
language eng
recordid cdi_proquest_miscellaneous_78062672
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Animals
Biological and medical sciences
Blood Substitutes - administration & dosage
Female
Fluorocarbons - administration & dosage
Investigative techniques, diagnostic techniques (general aspects)
Liver - chemistry
Lung - chemistry
Magnetic Resonance Spectroscopy - methods
Medical sciences
Miscellaneous. Technology
Oxygen - analysis
Oxygen - blood
Radiodiagnosis. Nmr imagery. Nmr spectrometry
Respiration
Spleen - chemistry
Swine
title In vivo PO2 imaging in the porcine model with perfluorocarbon F-19 NMR at low field
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T19%3A43%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20vivo%20PO2%20imaging%20in%20the%20porcine%20model%20with%20perfluorocarbon%20F-19%20NMR%20at%20low%20field&rft.jtitle=Magnetic%20resonance%20imaging&rft.au=THOMAS,%20S.%20R&rft.date=1996&rft.volume=14&rft.issue=1&rft.spage=103&rft.epage=114&rft.pages=103-114&rft.issn=0730-725X&rft.eissn=1873-5894&rft.coden=MRIMDQ&rft_id=info:doi/10.1016/0730-725X(95)02046-V&rft_dat=%3Cproquest_cross%3E78062672%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=78062672&rft_id=info:pmid/8656982&rfr_iscdi=true