New Technology in Wound Ballistics: The Doppler Radar

The feasibility of using Doppler radar to obtain more accurate measurements of velocity and yaw angle of bullets was investigated.Anesthetized pigs were shot at a range of 9-10 meters, and velocity measurements were obtained using Doppler radar and photocells. The data from the two types of equipmen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of Trauma: Injury, Infection, and Critical Care Infection, and Critical Care, 1996-03, Vol.40 (3S Suppl), p.42S-45S
Hauptverfasser: Knudsen, Peter J. T., Svender, Jorgen, Sorensen, Ole Heigaard
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 45S
container_issue 3S Suppl
container_start_page 42S
container_title The Journal of Trauma: Injury, Infection, and Critical Care
container_volume 40
creator Knudsen, Peter J. T.
Svender, Jorgen
Sorensen, Ole Heigaard
description The feasibility of using Doppler radar to obtain more accurate measurements of velocity and yaw angle of bullets was investigated.Anesthetized pigs were shot at a range of 9-10 meters, and velocity measurements were obtained using Doppler radar and photocells. The data from the two types of equipment was compared. Excellent correspondence was found between the measurements of entry velocities of low, medium, and high velocity bullets, i.e., an average deviation of less than 1% (range 0-2%). Measurements of exit velocities of low and medium velocity bullets corresponded just as well, but measurements of exit velocities of high velocity bullets was complicated in both methods by signal cluttering caused by fragments of tissue released from the exit wound and by the deflection of the bullet. A Doppler radar was used to follow the movements of the bullet, to determine the velocity, and, if possible, to determine when the bullet stabilizes and the exact yaw angles continuously. We were able to design a system in which even small caliber bullets could be followed for 15-20 meters. It was possible to detect yaw even with these small calibers, and the radar was not disturbed by additional equipment. Using Doppler radar to measure velocity offers important benefits--simple set up, minimal risk of damage to equipment by stray bullets, and very good accuracy. The results of measuring yaw angles of bullets are promising, as far as determining the point of stability is concerned, but further work is necessary to be able to measure the angle of yaw exactly.
doi_str_mv 10.1097/00005373-199603001-00008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77970580</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77970580</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3008-3282afae7f2057a5a34f6ba8f474702166bbe43fadd5ec406ad82f475e77a8453</originalsourceid><addsrcrecordid>eNp1UctOwzAQtBCoVKWfgJQTt8DGiWObG5SnVIGEijhaTrIhEW5c7ERV_x6Xlt7Yy0o7MzurWUKiBC4TkPwKQrGUp3EiZQ4pQBJvR-KIjBNGZSwEyGMyBqA0ZlTQUzL1vi0ChTIuqRiRkcghzxI5JuwF19ECy6azxn5uoraLPuzQVdGtNqb1fVv662jRYHRnVyuDLnrTlXZn5KTWxuN03yfk_eF-MXuK56-Pz7ObeVyGq0ScBnNda-Q1BcY102lW54UWdcYzDjTJ86LALK11VTEsM8h1JWgAGXKuRcbSCbnY7V05-z2g79Wy9SUaozu0g1ecSw5MQCCKHbF01nuHtVq5dqndRiWgtqGpv9DUIbTfkQjS873HUCyxOgj3EQU82-Fra3p0_ssMa3SqQW36Rv33i_QHu-B1BA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77970580</pqid></control><display><type>article</type><title>New Technology in Wound Ballistics: The Doppler Radar</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Knudsen, Peter J. T. ; Svender, Jorgen ; Sorensen, Ole Heigaard</creator><creatorcontrib>Knudsen, Peter J. T. ; Svender, Jorgen ; Sorensen, Ole Heigaard</creatorcontrib><description>The feasibility of using Doppler radar to obtain more accurate measurements of velocity and yaw angle of bullets was investigated.Anesthetized pigs were shot at a range of 9-10 meters, and velocity measurements were obtained using Doppler radar and photocells. The data from the two types of equipment was compared. Excellent correspondence was found between the measurements of entry velocities of low, medium, and high velocity bullets, i.e., an average deviation of less than 1% (range 0-2%). Measurements of exit velocities of low and medium velocity bullets corresponded just as well, but measurements of exit velocities of high velocity bullets was complicated in both methods by signal cluttering caused by fragments of tissue released from the exit wound and by the deflection of the bullet. A Doppler radar was used to follow the movements of the bullet, to determine the velocity, and, if possible, to determine when the bullet stabilizes and the exact yaw angles continuously. We were able to design a system in which even small caliber bullets could be followed for 15-20 meters. It was possible to detect yaw even with these small calibers, and the radar was not disturbed by additional equipment. Using Doppler radar to measure velocity offers important benefits--simple set up, minimal risk of damage to equipment by stray bullets, and very good accuracy. The results of measuring yaw angles of bullets are promising, as far as determining the point of stability is concerned, but further work is necessary to be able to measure the angle of yaw exactly.</description><identifier>ISSN: 0022-5282</identifier><identifier>EISSN: 1529-8809</identifier><identifier>DOI: 10.1097/00005373-199603001-00008</identifier><identifier>PMID: 8606419</identifier><language>eng</language><publisher>United States: Williams &amp; Wilkins</publisher><subject>Animals ; Physical Phenomena ; Physics ; Swine ; Ultrasonics ; Wounds, Gunshot</subject><ispartof>The Journal of Trauma: Injury, Infection, and Critical Care, 1996-03, Vol.40 (3S Suppl), p.42S-45S</ispartof><rights>Williams &amp; Wilkins 1996. All Rights Reserved.</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3008-3282afae7f2057a5a34f6ba8f474702166bbe43fadd5ec406ad82f475e77a8453</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8606419$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Knudsen, Peter J. T.</creatorcontrib><creatorcontrib>Svender, Jorgen</creatorcontrib><creatorcontrib>Sorensen, Ole Heigaard</creatorcontrib><title>New Technology in Wound Ballistics: The Doppler Radar</title><title>The Journal of Trauma: Injury, Infection, and Critical Care</title><addtitle>J Trauma</addtitle><description>The feasibility of using Doppler radar to obtain more accurate measurements of velocity and yaw angle of bullets was investigated.Anesthetized pigs were shot at a range of 9-10 meters, and velocity measurements were obtained using Doppler radar and photocells. The data from the two types of equipment was compared. Excellent correspondence was found between the measurements of entry velocities of low, medium, and high velocity bullets, i.e., an average deviation of less than 1% (range 0-2%). Measurements of exit velocities of low and medium velocity bullets corresponded just as well, but measurements of exit velocities of high velocity bullets was complicated in both methods by signal cluttering caused by fragments of tissue released from the exit wound and by the deflection of the bullet. A Doppler radar was used to follow the movements of the bullet, to determine the velocity, and, if possible, to determine when the bullet stabilizes and the exact yaw angles continuously. We were able to design a system in which even small caliber bullets could be followed for 15-20 meters. It was possible to detect yaw even with these small calibers, and the radar was not disturbed by additional equipment. Using Doppler radar to measure velocity offers important benefits--simple set up, minimal risk of damage to equipment by stray bullets, and very good accuracy. The results of measuring yaw angles of bullets are promising, as far as determining the point of stability is concerned, but further work is necessary to be able to measure the angle of yaw exactly.</description><subject>Animals</subject><subject>Physical Phenomena</subject><subject>Physics</subject><subject>Swine</subject><subject>Ultrasonics</subject><subject>Wounds, Gunshot</subject><issn>0022-5282</issn><issn>1529-8809</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1UctOwzAQtBCoVKWfgJQTt8DGiWObG5SnVIGEijhaTrIhEW5c7ERV_x6Xlt7Yy0o7MzurWUKiBC4TkPwKQrGUp3EiZQ4pQBJvR-KIjBNGZSwEyGMyBqA0ZlTQUzL1vi0ChTIuqRiRkcghzxI5JuwF19ECy6azxn5uoraLPuzQVdGtNqb1fVv662jRYHRnVyuDLnrTlXZn5KTWxuN03yfk_eF-MXuK56-Pz7ObeVyGq0ScBnNda-Q1BcY102lW54UWdcYzDjTJ86LALK11VTEsM8h1JWgAGXKuRcbSCbnY7V05-z2g79Wy9SUaozu0g1ecSw5MQCCKHbF01nuHtVq5dqndRiWgtqGpv9DUIbTfkQjS873HUCyxOgj3EQU82-Fra3p0_ssMa3SqQW36Rv33i_QHu-B1BA</recordid><startdate>199603</startdate><enddate>199603</enddate><creator>Knudsen, Peter J. T.</creator><creator>Svender, Jorgen</creator><creator>Sorensen, Ole Heigaard</creator><general>Williams &amp; Wilkins</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199603</creationdate><title>New Technology in Wound Ballistics: The Doppler Radar</title><author>Knudsen, Peter J. T. ; Svender, Jorgen ; Sorensen, Ole Heigaard</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3008-3282afae7f2057a5a34f6ba8f474702166bbe43fadd5ec406ad82f475e77a8453</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Animals</topic><topic>Physical Phenomena</topic><topic>Physics</topic><topic>Swine</topic><topic>Ultrasonics</topic><topic>Wounds, Gunshot</topic><toplevel>online_resources</toplevel><creatorcontrib>Knudsen, Peter J. T.</creatorcontrib><creatorcontrib>Svender, Jorgen</creatorcontrib><creatorcontrib>Sorensen, Ole Heigaard</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of Trauma: Injury, Infection, and Critical Care</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Knudsen, Peter J. T.</au><au>Svender, Jorgen</au><au>Sorensen, Ole Heigaard</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>New Technology in Wound Ballistics: The Doppler Radar</atitle><jtitle>The Journal of Trauma: Injury, Infection, and Critical Care</jtitle><addtitle>J Trauma</addtitle><date>1996-03</date><risdate>1996</risdate><volume>40</volume><issue>3S Suppl</issue><spage>42S</spage><epage>45S</epage><pages>42S-45S</pages><issn>0022-5282</issn><eissn>1529-8809</eissn><abstract>The feasibility of using Doppler radar to obtain more accurate measurements of velocity and yaw angle of bullets was investigated.Anesthetized pigs were shot at a range of 9-10 meters, and velocity measurements were obtained using Doppler radar and photocells. The data from the two types of equipment was compared. Excellent correspondence was found between the measurements of entry velocities of low, medium, and high velocity bullets, i.e., an average deviation of less than 1% (range 0-2%). Measurements of exit velocities of low and medium velocity bullets corresponded just as well, but measurements of exit velocities of high velocity bullets was complicated in both methods by signal cluttering caused by fragments of tissue released from the exit wound and by the deflection of the bullet. A Doppler radar was used to follow the movements of the bullet, to determine the velocity, and, if possible, to determine when the bullet stabilizes and the exact yaw angles continuously. We were able to design a system in which even small caliber bullets could be followed for 15-20 meters. It was possible to detect yaw even with these small calibers, and the radar was not disturbed by additional equipment. Using Doppler radar to measure velocity offers important benefits--simple set up, minimal risk of damage to equipment by stray bullets, and very good accuracy. The results of measuring yaw angles of bullets are promising, as far as determining the point of stability is concerned, but further work is necessary to be able to measure the angle of yaw exactly.</abstract><cop>United States</cop><pub>Williams &amp; Wilkins</pub><pmid>8606419</pmid><doi>10.1097/00005373-199603001-00008</doi></addata></record>
fulltext fulltext
identifier ISSN: 0022-5282
ispartof The Journal of Trauma: Injury, Infection, and Critical Care, 1996-03, Vol.40 (3S Suppl), p.42S-45S
issn 0022-5282
1529-8809
language eng
recordid cdi_proquest_miscellaneous_77970580
source MEDLINE; Journals@Ovid Complete
subjects Animals
Physical Phenomena
Physics
Swine
Ultrasonics
Wounds, Gunshot
title New Technology in Wound Ballistics: The Doppler Radar
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T13%3A02%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=New%20Technology%20in%20Wound%20Ballistics:%20The%20Doppler%20Radar&rft.jtitle=The%20Journal%20of%20Trauma:%20Injury,%20Infection,%20and%20Critical%20Care&rft.au=Knudsen,%20Peter%20J.%20T.&rft.date=1996-03&rft.volume=40&rft.issue=3S%20Suppl&rft.spage=42S&rft.epage=45S&rft.pages=42S-45S&rft.issn=0022-5282&rft.eissn=1529-8809&rft_id=info:doi/10.1097/00005373-199603001-00008&rft_dat=%3Cproquest_cross%3E77970580%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77970580&rft_id=info:pmid/8606419&rfr_iscdi=true