Degeneration and aging affect the tensile behavior of human lumbar anulus fibrosus

Samples of human lumbar (L3-L4) anulus fibrosus from four different anatomic sites (anterior outer, posterolateral inner), ranging from normal to severely degenerate, were studied in uniaxial tension and measured for water content. To evaluate the effects of aging and degeneration on the tensile pro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spine (Philadelphia, Pa. 1976) Pa. 1976), 1995-12, Vol.20 (24), p.2690-2701
Hauptverfasser: ACAROGLU, E. R, LATRIDIS, J. C, SETTON, L. A, FOSTER, R. J, MOW, V. C, WEIDENBAUM, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2701
container_issue 24
container_start_page 2690
container_title Spine (Philadelphia, Pa. 1976)
container_volume 20
creator ACAROGLU, E. R
LATRIDIS, J. C
SETTON, L. A
FOSTER, R. J
MOW, V. C
WEIDENBAUM, M
description Samples of human lumbar (L3-L4) anulus fibrosus from four different anatomic sites (anterior outer, posterolateral inner), ranging from normal to severely degenerate, were studied in uniaxial tension and measured for water content. To evaluate the effects of aging and degeneration on the tensile properties and hydration of the anulus fibrosus in a site-specific manner. The relationship between hydration and parameters of the tensile behavior were investigated. Degeneration and aging have been shown to be related to dramatic changes in the composition and structure of the anulus fibrosus. The associated changes in the tensile, compressive, and shear properties of the anulus fibrosus have not been documented. Numerical studies using finite element models have attempted to simulate the degenerative process by incorporating estimated mechanical properties meant to represent the degenerate anulus fibrosus. Their results present findings that suggest that altered material properties of the anulus fibrosus affect the mechanics of the entire intervertebral disc. Samples of human lumbar anulus fibrosus were classified by grade of degeneration based on a morphologic grading scheme. Multiple layer anulus specimens from four sites in the disc were tested in uniaxial tension under quasistatic conditions in a physiologic saline bath. The tensile modules, Poisson's ratio, failure stress and strain, the strain energy density to failure, and the corresponding hydration were determined for each sample. The Poisson's ratio, failure stress, and strain energy density of the anulus fibrosus were found to be affected significantly by degeneration, with some evidence of a sensitivity of the tensile modulus to grade of degeneration. All material properties were found to exhibit a significant and greater dependence on site within the disc than on degenerative grade. Weak correlations between aging and the Poisson's ratio and strain energy density were observed. Water content of anulus fibrosus tissue was not affected by degeneration or aging, although correlations with tensile properties were observed. The dramatic changes in morphology, composition, and structure that occur in anulus fibrosus with aging and degeneration are accompanied by specific variations in the tensile properties, which were generally small in magnitude. Position of the anulus fibrosus within the intervertebral disc, particularly in the radial direction, appeared to be the most important variable affecting anu
doi_str_mv 10.1097/00007632-199512150-00010
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77884781</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77884781</sourcerecordid><originalsourceid>FETCH-LOGICAL-c405t-26553fe2fe3af2c722ad1668757629bf796d30043e02f75b32fa3dd82d941d8e3</originalsourceid><addsrcrecordid>eNo9kElLA0EQhfugxBj9CUIfxNto78tR4goBQfQ89ExXJy2zxO4ZwX_vaGLqUlDvvariQwhTck2J1TdkKq04K6i1kjIqSTFNKDlCc8IVK5jg6gSd5vwxjRWndoZmRgvNhJ6j1ztYQwfJDbHvsOs8duvYrbELAeoBDxvAA3Q5NoAr2Liv2CfcB7wZW9fhZmwrl6bU2IwZh1ilPo_5DB0H12Q43_cFen-4f1s-FauXx-fl7aqoBZFDwZSUPAALwF1gtWbMeaqU0VIrZqugrfKcEMGBsKBlxVlw3HvDvBXUG-ALdLXbu0395wh5KNuYa2ga10E_5lJrY4Q2dDKanbGe_ssJQrlNsXXpu6Sk_EVY_iMsDwjLP4RT9GJ_Y6xa8Ifgnt-kX-51l2vXhOS6OuaDjVmhCZf8Bw8tesY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77884781</pqid></control><display><type>article</type><title>Degeneration and aging affect the tensile behavior of human lumbar anulus fibrosus</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>ACAROGLU, E. R ; LATRIDIS, J. C ; SETTON, L. A ; FOSTER, R. J ; MOW, V. C ; WEIDENBAUM, M</creator><creatorcontrib>ACAROGLU, E. R ; LATRIDIS, J. C ; SETTON, L. A ; FOSTER, R. J ; MOW, V. C ; WEIDENBAUM, M</creatorcontrib><description>Samples of human lumbar (L3-L4) anulus fibrosus from four different anatomic sites (anterior outer, posterolateral inner), ranging from normal to severely degenerate, were studied in uniaxial tension and measured for water content. To evaluate the effects of aging and degeneration on the tensile properties and hydration of the anulus fibrosus in a site-specific manner. The relationship between hydration and parameters of the tensile behavior were investigated. Degeneration and aging have been shown to be related to dramatic changes in the composition and structure of the anulus fibrosus. The associated changes in the tensile, compressive, and shear properties of the anulus fibrosus have not been documented. Numerical studies using finite element models have attempted to simulate the degenerative process by incorporating estimated mechanical properties meant to represent the degenerate anulus fibrosus. Their results present findings that suggest that altered material properties of the anulus fibrosus affect the mechanics of the entire intervertebral disc. Samples of human lumbar anulus fibrosus were classified by grade of degeneration based on a morphologic grading scheme. Multiple layer anulus specimens from four sites in the disc were tested in uniaxial tension under quasistatic conditions in a physiologic saline bath. The tensile modules, Poisson's ratio, failure stress and strain, the strain energy density to failure, and the corresponding hydration were determined for each sample. The Poisson's ratio, failure stress, and strain energy density of the anulus fibrosus were found to be affected significantly by degeneration, with some evidence of a sensitivity of the tensile modulus to grade of degeneration. All material properties were found to exhibit a significant and greater dependence on site within the disc than on degenerative grade. Weak correlations between aging and the Poisson's ratio and strain energy density were observed. Water content of anulus fibrosus tissue was not affected by degeneration or aging, although correlations with tensile properties were observed. The dramatic changes in morphology, composition, and structure that occur in anulus fibrosus with aging and degeneration are accompanied by specific variations in the tensile properties, which were generally small in magnitude. Position of the anulus fibrosus within the intervertebral disc, particularly in the radial direction, appeared to be the most important variable affecting anulus fibrosus tensile properties. This dependence on position did not change with either aging or degeneration. Results from the present study may be useful in future finite element models to assess how altered material properties of the anulus fibrosus during degeneration and aging may affect the mechanics of the entire intervertebral disc.</description><identifier>ISSN: 0362-2436</identifier><identifier>DOI: 10.1097/00007632-199512150-00010</identifier><identifier>PMID: 8747247</identifier><identifier>CODEN: SPINDD</identifier><language>eng</language><publisher>Philadelphia, PA: Lippincott</publisher><subject>Adolescent ; Adult ; Aged ; Aged, 80 and over ; Aging - physiology ; Biological and medical sciences ; Child ; Child, Preschool ; Data Interpretation, Statistical ; Diseases of the osteoarticular system ; Humans ; Intervertebral Disc - chemistry ; Intervertebral Disc - pathology ; Intervertebral Disc - physiology ; Lumbar Vertebrae - pathology ; Lumbar Vertebrae - physiology ; Mathematics ; Medical sciences ; Middle Aged ; Osteoarthritis ; Tensile Strength - physiology ; Water - analysis</subject><ispartof>Spine (Philadelphia, Pa. 1976), 1995-12, Vol.20 (24), p.2690-2701</ispartof><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c405t-26553fe2fe3af2c722ad1668757629bf796d30043e02f75b32fa3dd82d941d8e3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2947035$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8747247$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ACAROGLU, E. R</creatorcontrib><creatorcontrib>LATRIDIS, J. C</creatorcontrib><creatorcontrib>SETTON, L. A</creatorcontrib><creatorcontrib>FOSTER, R. J</creatorcontrib><creatorcontrib>MOW, V. C</creatorcontrib><creatorcontrib>WEIDENBAUM, M</creatorcontrib><title>Degeneration and aging affect the tensile behavior of human lumbar anulus fibrosus</title><title>Spine (Philadelphia, Pa. 1976)</title><addtitle>Spine (Phila Pa 1976)</addtitle><description>Samples of human lumbar (L3-L4) anulus fibrosus from four different anatomic sites (anterior outer, posterolateral inner), ranging from normal to severely degenerate, were studied in uniaxial tension and measured for water content. To evaluate the effects of aging and degeneration on the tensile properties and hydration of the anulus fibrosus in a site-specific manner. The relationship between hydration and parameters of the tensile behavior were investigated. Degeneration and aging have been shown to be related to dramatic changes in the composition and structure of the anulus fibrosus. The associated changes in the tensile, compressive, and shear properties of the anulus fibrosus have not been documented. Numerical studies using finite element models have attempted to simulate the degenerative process by incorporating estimated mechanical properties meant to represent the degenerate anulus fibrosus. Their results present findings that suggest that altered material properties of the anulus fibrosus affect the mechanics of the entire intervertebral disc. Samples of human lumbar anulus fibrosus were classified by grade of degeneration based on a morphologic grading scheme. Multiple layer anulus specimens from four sites in the disc were tested in uniaxial tension under quasistatic conditions in a physiologic saline bath. The tensile modules, Poisson's ratio, failure stress and strain, the strain energy density to failure, and the corresponding hydration were determined for each sample. The Poisson's ratio, failure stress, and strain energy density of the anulus fibrosus were found to be affected significantly by degeneration, with some evidence of a sensitivity of the tensile modulus to grade of degeneration. All material properties were found to exhibit a significant and greater dependence on site within the disc than on degenerative grade. Weak correlations between aging and the Poisson's ratio and strain energy density were observed. Water content of anulus fibrosus tissue was not affected by degeneration or aging, although correlations with tensile properties were observed. The dramatic changes in morphology, composition, and structure that occur in anulus fibrosus with aging and degeneration are accompanied by specific variations in the tensile properties, which were generally small in magnitude. Position of the anulus fibrosus within the intervertebral disc, particularly in the radial direction, appeared to be the most important variable affecting anulus fibrosus tensile properties. This dependence on position did not change with either aging or degeneration. Results from the present study may be useful in future finite element models to assess how altered material properties of the anulus fibrosus during degeneration and aging may affect the mechanics of the entire intervertebral disc.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Aging - physiology</subject><subject>Biological and medical sciences</subject><subject>Child</subject><subject>Child, Preschool</subject><subject>Data Interpretation, Statistical</subject><subject>Diseases of the osteoarticular system</subject><subject>Humans</subject><subject>Intervertebral Disc - chemistry</subject><subject>Intervertebral Disc - pathology</subject><subject>Intervertebral Disc - physiology</subject><subject>Lumbar Vertebrae - pathology</subject><subject>Lumbar Vertebrae - physiology</subject><subject>Mathematics</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Osteoarthritis</subject><subject>Tensile Strength - physiology</subject><subject>Water - analysis</subject><issn>0362-2436</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kElLA0EQhfugxBj9CUIfxNto78tR4goBQfQ89ExXJy2zxO4ZwX_vaGLqUlDvvariQwhTck2J1TdkKq04K6i1kjIqSTFNKDlCc8IVK5jg6gSd5vwxjRWndoZmRgvNhJ6j1ztYQwfJDbHvsOs8duvYrbELAeoBDxvAA3Q5NoAr2Liv2CfcB7wZW9fhZmwrl6bU2IwZh1ilPo_5DB0H12Q43_cFen-4f1s-FauXx-fl7aqoBZFDwZSUPAALwF1gtWbMeaqU0VIrZqugrfKcEMGBsKBlxVlw3HvDvBXUG-ALdLXbu0395wh5KNuYa2ga10E_5lJrY4Q2dDKanbGe_ssJQrlNsXXpu6Sk_EVY_iMsDwjLP4RT9GJ_Y6xa8Ifgnt-kX-51l2vXhOS6OuaDjVmhCZf8Bw8tesY</recordid><startdate>19951215</startdate><enddate>19951215</enddate><creator>ACAROGLU, E. R</creator><creator>LATRIDIS, J. C</creator><creator>SETTON, L. A</creator><creator>FOSTER, R. J</creator><creator>MOW, V. C</creator><creator>WEIDENBAUM, M</creator><general>Lippincott</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19951215</creationdate><title>Degeneration and aging affect the tensile behavior of human lumbar anulus fibrosus</title><author>ACAROGLU, E. R ; LATRIDIS, J. C ; SETTON, L. A ; FOSTER, R. J ; MOW, V. C ; WEIDENBAUM, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c405t-26553fe2fe3af2c722ad1668757629bf796d30043e02f75b32fa3dd82d941d8e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Aging - physiology</topic><topic>Biological and medical sciences</topic><topic>Child</topic><topic>Child, Preschool</topic><topic>Data Interpretation, Statistical</topic><topic>Diseases of the osteoarticular system</topic><topic>Humans</topic><topic>Intervertebral Disc - chemistry</topic><topic>Intervertebral Disc - pathology</topic><topic>Intervertebral Disc - physiology</topic><topic>Lumbar Vertebrae - pathology</topic><topic>Lumbar Vertebrae - physiology</topic><topic>Mathematics</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Osteoarthritis</topic><topic>Tensile Strength - physiology</topic><topic>Water - analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ACAROGLU, E. R</creatorcontrib><creatorcontrib>LATRIDIS, J. C</creatorcontrib><creatorcontrib>SETTON, L. A</creatorcontrib><creatorcontrib>FOSTER, R. J</creatorcontrib><creatorcontrib>MOW, V. C</creatorcontrib><creatorcontrib>WEIDENBAUM, M</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Spine (Philadelphia, Pa. 1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ACAROGLU, E. R</au><au>LATRIDIS, J. C</au><au>SETTON, L. A</au><au>FOSTER, R. J</au><au>MOW, V. C</au><au>WEIDENBAUM, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Degeneration and aging affect the tensile behavior of human lumbar anulus fibrosus</atitle><jtitle>Spine (Philadelphia, Pa. 1976)</jtitle><addtitle>Spine (Phila Pa 1976)</addtitle><date>1995-12-15</date><risdate>1995</risdate><volume>20</volume><issue>24</issue><spage>2690</spage><epage>2701</epage><pages>2690-2701</pages><issn>0362-2436</issn><coden>SPINDD</coden><abstract>Samples of human lumbar (L3-L4) anulus fibrosus from four different anatomic sites (anterior outer, posterolateral inner), ranging from normal to severely degenerate, were studied in uniaxial tension and measured for water content. To evaluate the effects of aging and degeneration on the tensile properties and hydration of the anulus fibrosus in a site-specific manner. The relationship between hydration and parameters of the tensile behavior were investigated. Degeneration and aging have been shown to be related to dramatic changes in the composition and structure of the anulus fibrosus. The associated changes in the tensile, compressive, and shear properties of the anulus fibrosus have not been documented. Numerical studies using finite element models have attempted to simulate the degenerative process by incorporating estimated mechanical properties meant to represent the degenerate anulus fibrosus. Their results present findings that suggest that altered material properties of the anulus fibrosus affect the mechanics of the entire intervertebral disc. Samples of human lumbar anulus fibrosus were classified by grade of degeneration based on a morphologic grading scheme. Multiple layer anulus specimens from four sites in the disc were tested in uniaxial tension under quasistatic conditions in a physiologic saline bath. The tensile modules, Poisson's ratio, failure stress and strain, the strain energy density to failure, and the corresponding hydration were determined for each sample. The Poisson's ratio, failure stress, and strain energy density of the anulus fibrosus were found to be affected significantly by degeneration, with some evidence of a sensitivity of the tensile modulus to grade of degeneration. All material properties were found to exhibit a significant and greater dependence on site within the disc than on degenerative grade. Weak correlations between aging and the Poisson's ratio and strain energy density were observed. Water content of anulus fibrosus tissue was not affected by degeneration or aging, although correlations with tensile properties were observed. The dramatic changes in morphology, composition, and structure that occur in anulus fibrosus with aging and degeneration are accompanied by specific variations in the tensile properties, which were generally small in magnitude. Position of the anulus fibrosus within the intervertebral disc, particularly in the radial direction, appeared to be the most important variable affecting anulus fibrosus tensile properties. This dependence on position did not change with either aging or degeneration. Results from the present study may be useful in future finite element models to assess how altered material properties of the anulus fibrosus during degeneration and aging may affect the mechanics of the entire intervertebral disc.</abstract><cop>Philadelphia, PA</cop><cop>Hagerstown, MD</cop><pub>Lippincott</pub><pmid>8747247</pmid><doi>10.1097/00007632-199512150-00010</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0362-2436
ispartof Spine (Philadelphia, Pa. 1976), 1995-12, Vol.20 (24), p.2690-2701
issn 0362-2436
language eng
recordid cdi_proquest_miscellaneous_77884781
source MEDLINE; Journals@Ovid Complete
subjects Adolescent
Adult
Aged
Aged, 80 and over
Aging - physiology
Biological and medical sciences
Child
Child, Preschool
Data Interpretation, Statistical
Diseases of the osteoarticular system
Humans
Intervertebral Disc - chemistry
Intervertebral Disc - pathology
Intervertebral Disc - physiology
Lumbar Vertebrae - pathology
Lumbar Vertebrae - physiology
Mathematics
Medical sciences
Middle Aged
Osteoarthritis
Tensile Strength - physiology
Water - analysis
title Degeneration and aging affect the tensile behavior of human lumbar anulus fibrosus
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T20%3A28%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Degeneration%20and%20aging%20affect%20the%20tensile%20behavior%20of%20human%20lumbar%20anulus%20fibrosus&rft.jtitle=Spine%20(Philadelphia,%20Pa.%201976)&rft.au=ACAROGLU,%20E.%20R&rft.date=1995-12-15&rft.volume=20&rft.issue=24&rft.spage=2690&rft.epage=2701&rft.pages=2690-2701&rft.issn=0362-2436&rft.coden=SPINDD&rft_id=info:doi/10.1097/00007632-199512150-00010&rft_dat=%3Cproquest_cross%3E77884781%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77884781&rft_id=info:pmid/8747247&rfr_iscdi=true