Comparison of Sinus Node Response to Exercise with Responses From Two Different Activity-Based Rate Adaptive Pacemakers in Healthy Subjects of Different Age Groups

The pacing rates from accelerometer‐based (Excel™) and piezoelectric‐based (Legend™) activity sensing rate adaptive pacemakers, both strapped externally in the pectoral position, were compared with sinus rate response in normal volunteers of two different age groups (group 1, mean age 35 ± 16 years;...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pacing and clinical electrophysiology 1995-10, Vol.18 (10), p.1882-1888
Hauptverfasser: ROBERTS, DAVID H., BAXTER, SUSAN E., BRENNAN, PAULA T., GAMMAGE, MICHAEL D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1888
container_issue 10
container_start_page 1882
container_title Pacing and clinical electrophysiology
container_volume 18
creator ROBERTS, DAVID H.
BAXTER, SUSAN E.
BRENNAN, PAULA T.
GAMMAGE, MICHAEL D.
description The pacing rates from accelerometer‐based (Excel™) and piezoelectric‐based (Legend™) activity sensing rate adaptive pacemakers, both strapped externally in the pectoral position, were compared with sinus rate response in normal volunteers of two different age groups (group 1, mean age 35 ± 16 years; group 2, mean age 72 ± 9 years) during various physical activities. Both pacemakers were programmed in manufacturers' nominal rate adaptive settings. Both types of activity sensing pacemakers programmed in this way showed chronotropic deficiencies to metabolic demand in healthy young subjects and in those matching the usual age of pacemaker implant, especially during “burst” activities. These data suggest that present recommended activity sensing rate response algorithms for accelerometer and piezoelectric pacemakers are inappropriate for many physical activities.
doi_str_mv 10.1111/j.1540-8159.1995.tb03836.x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77783820</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77783820</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3242-d4c56a62e2d30ff811de376cd382cbc5d1a0c2da95e663de8f6e4ba046e4f68c3</originalsourceid><addsrcrecordid>eNqVkdFu0zAUhiMEGmXwCEgWF9wls-PEcbiilK5FjDFtQ1xajn3C3CVxsJ21fR5elEStKm7xzbH9-3y2_EXRO4ITMo6LTULyDMec5GVCyjJPQoUppyzZPYtmp-h5NMMkK2JOefkyeuX9BmPMcJafRWc8pyXJ2Sz6s7BtL53xtkO2RnemGzy6thrQLfjedh5QsGi5A6fMON-a8HBKPLp0tkX3W4s-m7oGB11AcxXMkwn7-JP0oNGtDIDmWvbjLqAbqaCVj-A8Mh1ag2zCwx7dDdUGVPDTA_4B_QK0cnbo_evoRS0bD2-O9Tz6cbm8X6zjq--rL4v5VaxomqWxzlTOJEsh1RTXNSdEAy2Y0pSnqlK5JhKrVMsyB8aoBl4zyCqJs7HUjCt6Hr0_cHtnfw_gg2iNV9A0sgM7eFEUxfiXKR4PfjgcVM5676AWvTOtdHtBsJgMiY2YNIhJg5gMiaMhsRub3x5vGaoW9Kn1qGTMPx7yrWlg_x9kcTNfLAnn6YiIDwjjA-xOCOkeBStokYuf1yvxLftalutxsaJ_AZoHs44</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77783820</pqid></control><display><type>article</type><title>Comparison of Sinus Node Response to Exercise with Responses From Two Different Activity-Based Rate Adaptive Pacemakers in Healthy Subjects of Different Age Groups</title><source>MEDLINE</source><source>Access via Wiley Online Library</source><creator>ROBERTS, DAVID H. ; BAXTER, SUSAN E. ; BRENNAN, PAULA T. ; GAMMAGE, MICHAEL D.</creator><creatorcontrib>ROBERTS, DAVID H. ; BAXTER, SUSAN E. ; BRENNAN, PAULA T. ; GAMMAGE, MICHAEL D.</creatorcontrib><description>The pacing rates from accelerometer‐based (Excel™) and piezoelectric‐based (Legend™) activity sensing rate adaptive pacemakers, both strapped externally in the pectoral position, were compared with sinus rate response in normal volunteers of two different age groups (group 1, mean age 35 ± 16 years; group 2, mean age 72 ± 9 years) during various physical activities. Both pacemakers were programmed in manufacturers' nominal rate adaptive settings. Both types of activity sensing pacemakers programmed in this way showed chronotropic deficiencies to metabolic demand in healthy young subjects and in those matching the usual age of pacemaker implant, especially during “burst” activities. These data suggest that present recommended activity sensing rate response algorithms for accelerometer and piezoelectric pacemakers are inappropriate for many physical activities.</description><identifier>ISSN: 0147-8389</identifier><identifier>EISSN: 1540-8159</identifier><identifier>DOI: 10.1111/j.1540-8159.1995.tb03836.x</identifier><identifier>PMID: 8539156</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>accelerometer ; Adult ; Aged ; Aging - physiology ; Electrocardiography, Ambulatory ; Female ; Holter monitoring ; Humans ; Male ; Middle Aged ; Pacemaker, Artificial ; Physical Exertion ; piezoelectric pacemaker ; Sinoatrial Node - physiology ; sinus node response</subject><ispartof>Pacing and clinical electrophysiology, 1995-10, Vol.18 (10), p.1882-1888</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3242-d4c56a62e2d30ff811de376cd382cbc5d1a0c2da95e663de8f6e4ba046e4f68c3</citedby><cites>FETCH-LOGICAL-c3242-d4c56a62e2d30ff811de376cd382cbc5d1a0c2da95e663de8f6e4ba046e4f68c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1540-8159.1995.tb03836.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1540-8159.1995.tb03836.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8539156$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ROBERTS, DAVID H.</creatorcontrib><creatorcontrib>BAXTER, SUSAN E.</creatorcontrib><creatorcontrib>BRENNAN, PAULA T.</creatorcontrib><creatorcontrib>GAMMAGE, MICHAEL D.</creatorcontrib><title>Comparison of Sinus Node Response to Exercise with Responses From Two Different Activity-Based Rate Adaptive Pacemakers in Healthy Subjects of Different Age Groups</title><title>Pacing and clinical electrophysiology</title><addtitle>Pacing Clin Electrophysiol</addtitle><description>The pacing rates from accelerometer‐based (Excel™) and piezoelectric‐based (Legend™) activity sensing rate adaptive pacemakers, both strapped externally in the pectoral position, were compared with sinus rate response in normal volunteers of two different age groups (group 1, mean age 35 ± 16 years; group 2, mean age 72 ± 9 years) during various physical activities. Both pacemakers were programmed in manufacturers' nominal rate adaptive settings. Both types of activity sensing pacemakers programmed in this way showed chronotropic deficiencies to metabolic demand in healthy young subjects and in those matching the usual age of pacemaker implant, especially during “burst” activities. These data suggest that present recommended activity sensing rate response algorithms for accelerometer and piezoelectric pacemakers are inappropriate for many physical activities.</description><subject>accelerometer</subject><subject>Adult</subject><subject>Aged</subject><subject>Aging - physiology</subject><subject>Electrocardiography, Ambulatory</subject><subject>Female</subject><subject>Holter monitoring</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Pacemaker, Artificial</subject><subject>Physical Exertion</subject><subject>piezoelectric pacemaker</subject><subject>Sinoatrial Node - physiology</subject><subject>sinus node response</subject><issn>0147-8389</issn><issn>1540-8159</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqVkdFu0zAUhiMEGmXwCEgWF9wls-PEcbiilK5FjDFtQ1xajn3C3CVxsJ21fR5elEStKm7xzbH9-3y2_EXRO4ITMo6LTULyDMec5GVCyjJPQoUppyzZPYtmp-h5NMMkK2JOefkyeuX9BmPMcJafRWc8pyXJ2Sz6s7BtL53xtkO2RnemGzy6thrQLfjedh5QsGi5A6fMON-a8HBKPLp0tkX3W4s-m7oGB11AcxXMkwn7-JP0oNGtDIDmWvbjLqAbqaCVj-A8Mh1ag2zCwx7dDdUGVPDTA_4B_QK0cnbo_evoRS0bD2-O9Tz6cbm8X6zjq--rL4v5VaxomqWxzlTOJEsh1RTXNSdEAy2Y0pSnqlK5JhKrVMsyB8aoBl4zyCqJs7HUjCt6Hr0_cHtnfw_gg2iNV9A0sgM7eFEUxfiXKR4PfjgcVM5676AWvTOtdHtBsJgMiY2YNIhJg5gMiaMhsRub3x5vGaoW9Kn1qGTMPx7yrWlg_x9kcTNfLAnn6YiIDwjjA-xOCOkeBStokYuf1yvxLftalutxsaJ_AZoHs44</recordid><startdate>199510</startdate><enddate>199510</enddate><creator>ROBERTS, DAVID H.</creator><creator>BAXTER, SUSAN E.</creator><creator>BRENNAN, PAULA T.</creator><creator>GAMMAGE, MICHAEL D.</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199510</creationdate><title>Comparison of Sinus Node Response to Exercise with Responses From Two Different Activity-Based Rate Adaptive Pacemakers in Healthy Subjects of Different Age Groups</title><author>ROBERTS, DAVID H. ; BAXTER, SUSAN E. ; BRENNAN, PAULA T. ; GAMMAGE, MICHAEL D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3242-d4c56a62e2d30ff811de376cd382cbc5d1a0c2da95e663de8f6e4ba046e4f68c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>accelerometer</topic><topic>Adult</topic><topic>Aged</topic><topic>Aging - physiology</topic><topic>Electrocardiography, Ambulatory</topic><topic>Female</topic><topic>Holter monitoring</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Pacemaker, Artificial</topic><topic>Physical Exertion</topic><topic>piezoelectric pacemaker</topic><topic>Sinoatrial Node - physiology</topic><topic>sinus node response</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ROBERTS, DAVID H.</creatorcontrib><creatorcontrib>BAXTER, SUSAN E.</creatorcontrib><creatorcontrib>BRENNAN, PAULA T.</creatorcontrib><creatorcontrib>GAMMAGE, MICHAEL D.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Pacing and clinical electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ROBERTS, DAVID H.</au><au>BAXTER, SUSAN E.</au><au>BRENNAN, PAULA T.</au><au>GAMMAGE, MICHAEL D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of Sinus Node Response to Exercise with Responses From Two Different Activity-Based Rate Adaptive Pacemakers in Healthy Subjects of Different Age Groups</atitle><jtitle>Pacing and clinical electrophysiology</jtitle><addtitle>Pacing Clin Electrophysiol</addtitle><date>1995-10</date><risdate>1995</risdate><volume>18</volume><issue>10</issue><spage>1882</spage><epage>1888</epage><pages>1882-1888</pages><issn>0147-8389</issn><eissn>1540-8159</eissn><abstract>The pacing rates from accelerometer‐based (Excel™) and piezoelectric‐based (Legend™) activity sensing rate adaptive pacemakers, both strapped externally in the pectoral position, were compared with sinus rate response in normal volunteers of two different age groups (group 1, mean age 35 ± 16 years; group 2, mean age 72 ± 9 years) during various physical activities. Both pacemakers were programmed in manufacturers' nominal rate adaptive settings. Both types of activity sensing pacemakers programmed in this way showed chronotropic deficiencies to metabolic demand in healthy young subjects and in those matching the usual age of pacemaker implant, especially during “burst” activities. These data suggest that present recommended activity sensing rate response algorithms for accelerometer and piezoelectric pacemakers are inappropriate for many physical activities.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>8539156</pmid><doi>10.1111/j.1540-8159.1995.tb03836.x</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0147-8389
ispartof Pacing and clinical electrophysiology, 1995-10, Vol.18 (10), p.1882-1888
issn 0147-8389
1540-8159
language eng
recordid cdi_proquest_miscellaneous_77783820
source MEDLINE; Access via Wiley Online Library
subjects accelerometer
Adult
Aged
Aging - physiology
Electrocardiography, Ambulatory
Female
Holter monitoring
Humans
Male
Middle Aged
Pacemaker, Artificial
Physical Exertion
piezoelectric pacemaker
Sinoatrial Node - physiology
sinus node response
title Comparison of Sinus Node Response to Exercise with Responses From Two Different Activity-Based Rate Adaptive Pacemakers in Healthy Subjects of Different Age Groups
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T20%3A51%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20Sinus%20Node%20Response%20to%20Exercise%20with%20Responses%20From%20Two%20Different%20Activity-Based%20Rate%20Adaptive%20Pacemakers%20in%20Healthy%20Subjects%20of%20Different%20Age%20Groups&rft.jtitle=Pacing%20and%20clinical%20electrophysiology&rft.au=ROBERTS,%20DAVID%20H.&rft.date=1995-10&rft.volume=18&rft.issue=10&rft.spage=1882&rft.epage=1888&rft.pages=1882-1888&rft.issn=0147-8389&rft.eissn=1540-8159&rft_id=info:doi/10.1111/j.1540-8159.1995.tb03836.x&rft_dat=%3Cproquest_cross%3E77783820%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77783820&rft_id=info:pmid/8539156&rfr_iscdi=true