ESTRACE-1: a stethoscope for functional checking of electrostimulators and low cost body surface mapping system

In a project on the mapping of body surface potentials evoked by implanted spinal cord stimulators and transcutaneous electrostimulators, a simple device was developed for use in polyclinical practice for easy checking of the function of these stimulators. The device is an electrical stethoscope and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical engineering & physics 1994-11, Vol.16 (6), p.492-495
Hauptverfasser: Journée, H.L., Hulshof, M., de Jonge, A.B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 495
container_issue 6
container_start_page 492
container_title Medical engineering & physics
container_volume 16
creator Journée, H.L.
Hulshof, M.
de Jonge, A.B.
description In a project on the mapping of body surface potentials evoked by implanted spinal cord stimulators and transcutaneous electrostimulators, a simple device was developed for use in polyclinical practice for easy checking of the function of these stimulators. The device is an electrical stethoscope and consists of an instrumentation amplifier, bandpass filter, a distortion circuit and a headphone. In vivo measurements demonstrate the generation of an amplitude-dependent tone by the distortion circuit. The apparatus is in many aspects similar to a stethoscope: simple to understand and a practical tool for a fast Go/No-Go test. The device can be optionally connected with a PC and enables body surface mapping documentation within a few minutes.
doi_str_mv 10.1016/1350-4533(94)90074-4
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77736935</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1350453394900744</els_id><sourcerecordid>16910810</sourcerecordid><originalsourceid>FETCH-LOGICAL-c397t-c329b6274709a6575b3624b037d23436b3dbefbfc7c3214d27e1e0e5ad1ac0573</originalsourceid><addsrcrecordid>eNqFkU1v1DAQhiMEKqXwD0DyAaFyCIzjr4QDUrVaPqRKSFDOlmOPqSGJUzuh2n-Pl116pBfb8jzzajRPVT2n8IYClW8pE1Bzwdh5x193AIrX_EF1SlvFag4MHpb3P-Rx9STnnwDAuWQn1YlqRataelrF7berrxebbU3fEUPygst1zDbOSHxMxK-TXUKczEDsNdpfYfpBoic4oF1SzEsY18EsMWViJkeGeEts-SV9dDuS1-SNRTKaed735V1JH59Wj7wZMj473mfV9w_bq82n-vLLx8-bi8vask4t5Wy6XjaKK-iMFEr0TDa8B6ZcwziTPXM9-t5bVUjKXaOQIqAwjhoLQrGz6tUhd07xZsW86DFki8NgJoxr1kopJjsm7gUbKVoqmvZekMqOQkuhgPwA2rKinNDrOYXRpJ2moPfm9F6L3mvRHdd_zWle2l4c89d-RHfXdFRV6i-PdZOtGXwykw35DmNMCVBNwd4fMCzb_R0w6WwDThZdSMWadjH8f44_E6y0OA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>16910810</pqid></control><display><type>article</type><title>ESTRACE-1: a stethoscope for functional checking of electrostimulators and low cost body surface mapping system</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Journée, H.L. ; Hulshof, M. ; de Jonge, A.B.</creator><creatorcontrib>Journée, H.L. ; Hulshof, M. ; de Jonge, A.B.</creatorcontrib><description>In a project on the mapping of body surface potentials evoked by implanted spinal cord stimulators and transcutaneous electrostimulators, a simple device was developed for use in polyclinical practice for easy checking of the function of these stimulators. The device is an electrical stethoscope and consists of an instrumentation amplifier, bandpass filter, a distortion circuit and a headphone. In vivo measurements demonstrate the generation of an amplitude-dependent tone by the distortion circuit. The apparatus is in many aspects similar to a stethoscope: simple to understand and a practical tool for a fast Go/No-Go test. The device can be optionally connected with a PC and enables body surface mapping documentation within a few minutes.</description><identifier>ISSN: 1350-4533</identifier><identifier>EISSN: 1873-4030</identifier><identifier>DOI: 10.1016/1350-4533(94)90074-4</identifier><identifier>PMID: 7858781</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Adult ; Auscultation - economics ; Auscultation - instrumentation ; Biological and medical sciences ; body surface potential mapping ; Body Surface Potential Mapping - economics ; Body Surface Potential Mapping - instrumentation ; Electric Stimulation Therapy - standards ; Electrodes, Implanted ; Electrodiagnosis. Electric activity recording ; Equipment Design ; Equipment Failure ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Male ; Medical sciences ; Miscellaneous. Technology ; neuromodulation ; Spinal Cord ; spinal cord stimulation ; Transcutaneous electrical stimulation</subject><ispartof>Medical engineering &amp; physics, 1994-11, Vol.16 (6), p.492-495</ispartof><rights>1994</rights><rights>1995 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/1350453394900744$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3375072$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7858781$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Journée, H.L.</creatorcontrib><creatorcontrib>Hulshof, M.</creatorcontrib><creatorcontrib>de Jonge, A.B.</creatorcontrib><title>ESTRACE-1: a stethoscope for functional checking of electrostimulators and low cost body surface mapping system</title><title>Medical engineering &amp; physics</title><addtitle>Med Eng Phys</addtitle><description>In a project on the mapping of body surface potentials evoked by implanted spinal cord stimulators and transcutaneous electrostimulators, a simple device was developed for use in polyclinical practice for easy checking of the function of these stimulators. The device is an electrical stethoscope and consists of an instrumentation amplifier, bandpass filter, a distortion circuit and a headphone. In vivo measurements demonstrate the generation of an amplitude-dependent tone by the distortion circuit. The apparatus is in many aspects similar to a stethoscope: simple to understand and a practical tool for a fast Go/No-Go test. The device can be optionally connected with a PC and enables body surface mapping documentation within a few minutes.</description><subject>Adult</subject><subject>Auscultation - economics</subject><subject>Auscultation - instrumentation</subject><subject>Biological and medical sciences</subject><subject>body surface potential mapping</subject><subject>Body Surface Potential Mapping - economics</subject><subject>Body Surface Potential Mapping - instrumentation</subject><subject>Electric Stimulation Therapy - standards</subject><subject>Electrodes, Implanted</subject><subject>Electrodiagnosis. Electric activity recording</subject><subject>Equipment Design</subject><subject>Equipment Failure</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Miscellaneous. Technology</subject><subject>neuromodulation</subject><subject>Spinal Cord</subject><subject>spinal cord stimulation</subject><subject>Transcutaneous electrical stimulation</subject><issn>1350-4533</issn><issn>1873-4030</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkU1v1DAQhiMEKqXwD0DyAaFyCIzjr4QDUrVaPqRKSFDOlmOPqSGJUzuh2n-Pl116pBfb8jzzajRPVT2n8IYClW8pE1Bzwdh5x193AIrX_EF1SlvFag4MHpb3P-Rx9STnnwDAuWQn1YlqRataelrF7berrxebbU3fEUPygst1zDbOSHxMxK-TXUKczEDsNdpfYfpBoic4oF1SzEsY18EsMWViJkeGeEts-SV9dDuS1-SNRTKaed735V1JH59Wj7wZMj473mfV9w_bq82n-vLLx8-bi8vask4t5Wy6XjaKK-iMFEr0TDa8B6ZcwziTPXM9-t5bVUjKXaOQIqAwjhoLQrGz6tUhd07xZsW86DFki8NgJoxr1kopJjsm7gUbKVoqmvZekMqOQkuhgPwA2rKinNDrOYXRpJ2moPfm9F6L3mvRHdd_zWle2l4c89d-RHfXdFRV6i-PdZOtGXwykw35DmNMCVBNwd4fMCzb_R0w6WwDThZdSMWadjH8f44_E6y0OA</recordid><startdate>19941101</startdate><enddate>19941101</enddate><creator>Journée, H.L.</creator><creator>Hulshof, M.</creator><creator>de Jonge, A.B.</creator><general>Elsevier Ltd</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7SP</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>19941101</creationdate><title>ESTRACE-1: a stethoscope for functional checking of electrostimulators and low cost body surface mapping system</title><author>Journée, H.L. ; Hulshof, M. ; de Jonge, A.B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c397t-c329b6274709a6575b3624b037d23436b3dbefbfc7c3214d27e1e0e5ad1ac0573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Adult</topic><topic>Auscultation - economics</topic><topic>Auscultation - instrumentation</topic><topic>Biological and medical sciences</topic><topic>body surface potential mapping</topic><topic>Body Surface Potential Mapping - economics</topic><topic>Body Surface Potential Mapping - instrumentation</topic><topic>Electric Stimulation Therapy - standards</topic><topic>Electrodes, Implanted</topic><topic>Electrodiagnosis. Electric activity recording</topic><topic>Equipment Design</topic><topic>Equipment Failure</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Miscellaneous. Technology</topic><topic>neuromodulation</topic><topic>Spinal Cord</topic><topic>spinal cord stimulation</topic><topic>Transcutaneous electrical stimulation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Journée, H.L.</creatorcontrib><creatorcontrib>Hulshof, M.</creatorcontrib><creatorcontrib>de Jonge, A.B.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Medical engineering &amp; physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Journée, H.L.</au><au>Hulshof, M.</au><au>de Jonge, A.B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>ESTRACE-1: a stethoscope for functional checking of electrostimulators and low cost body surface mapping system</atitle><jtitle>Medical engineering &amp; physics</jtitle><addtitle>Med Eng Phys</addtitle><date>1994-11-01</date><risdate>1994</risdate><volume>16</volume><issue>6</issue><spage>492</spage><epage>495</epage><pages>492-495</pages><issn>1350-4533</issn><eissn>1873-4030</eissn><abstract>In a project on the mapping of body surface potentials evoked by implanted spinal cord stimulators and transcutaneous electrostimulators, a simple device was developed for use in polyclinical practice for easy checking of the function of these stimulators. The device is an electrical stethoscope and consists of an instrumentation amplifier, bandpass filter, a distortion circuit and a headphone. In vivo measurements demonstrate the generation of an amplitude-dependent tone by the distortion circuit. The apparatus is in many aspects similar to a stethoscope: simple to understand and a practical tool for a fast Go/No-Go test. The device can be optionally connected with a PC and enables body surface mapping documentation within a few minutes.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><pmid>7858781</pmid><doi>10.1016/1350-4533(94)90074-4</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1350-4533
ispartof Medical engineering & physics, 1994-11, Vol.16 (6), p.492-495
issn 1350-4533
1873-4030
language eng
recordid cdi_proquest_miscellaneous_77736935
source MEDLINE; Elsevier ScienceDirect Journals
subjects Adult
Auscultation - economics
Auscultation - instrumentation
Biological and medical sciences
body surface potential mapping
Body Surface Potential Mapping - economics
Body Surface Potential Mapping - instrumentation
Electric Stimulation Therapy - standards
Electrodes, Implanted
Electrodiagnosis. Electric activity recording
Equipment Design
Equipment Failure
Humans
Investigative techniques, diagnostic techniques (general aspects)
Male
Medical sciences
Miscellaneous. Technology
neuromodulation
Spinal Cord
spinal cord stimulation
Transcutaneous electrical stimulation
title ESTRACE-1: a stethoscope for functional checking of electrostimulators and low cost body surface mapping system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T23%3A44%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=ESTRACE-1:%20a%20stethoscope%20for%20functional%20checking%20of%20electrostimulators%20and%20low%20cost%20body%20surface%20mapping%20system&rft.jtitle=Medical%20engineering%20&%20physics&rft.au=Journ%C3%A9e,%20H.L.&rft.date=1994-11-01&rft.volume=16&rft.issue=6&rft.spage=492&rft.epage=495&rft.pages=492-495&rft.issn=1350-4533&rft.eissn=1873-4030&rft_id=info:doi/10.1016/1350-4533(94)90074-4&rft_dat=%3Cproquest_cross%3E16910810%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=16910810&rft_id=info:pmid/7858781&rft_els_id=1350453394900744&rfr_iscdi=true