Artificial endocrine pancreas and optimal blood glucose regulation in diabetic patients — from bedside-type to wearable-type
The artificial endocrine pancreas is a feedback control system regulating insulin delivery on a minute-by-minute basis according to the measured blood glucose levels. The bedside-type artificial endocrine pancreas has been proven to be useful not only as a therapeutic tool for diabetes mellitus but...
Gespeichert in:
Veröffentlicht in: | Diabetes research and clinical practice 1994-10, Vol.24, p.S251-S259 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | S259 |
---|---|
container_issue | |
container_start_page | S251 |
container_title | Diabetes research and clinical practice |
container_volume | 24 |
creator | Shichiri, Motoaki Kishikawa, Hideki Sakakida, Michiharu Kajiwara, Kenichiro Hashiguchi, Yasuhiro Nishida, Kenro Uemura, Takero Konno, Yumi Ichinose, Kenshi |
description | The artificial endocrine pancreas is a feedback control system regulating insulin delivery on a minute-by-minute basis according to the measured blood glucose levels. The bedside-type artificial endocrine pancreas has been proven to be useful not only as a therapeutic tool for diabetes mellitus but also as an elegant research tool for investigating the pathophysiology of the disease. With significant advances in the development of a subcutaneous tissue glucose monitoring system, the wearable-type artificial endocrine pancreas has been applied to diabetic patients. With this system, perfect glycemic control can be obtained for longer periods in ambulatory diabetic patients. The trend in the development of the artificial endocrine pancreas is now directed to implantable devices. Much efforts have been conducted to realize these devices. |
doi_str_mv | 10.1016/0168-8227(94)90258-5 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77728213</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0168822794902585</els_id><sourcerecordid>77728213</sourcerecordid><originalsourceid>FETCH-LOGICAL-c452t-36f1c0e00d3f44d3d9f71fcbd9aac347d9b0dc86d2ecb94332ba695478ae2b63</originalsourceid><addsrcrecordid>eNp9kM1KHUEQhZsQMVfNGyTQqxAXo_0309MbQSRRQXDjvumfGukwd3rS3RO5G8lD5Al9Evt6Ly6zKArqnFNFfQh9oeSMEtqd1-qbnjH5XYlTRVjbN-0HtKK9ZG_jj2j1bvmEjnL-RQjpuGgP0aHsW9XRdoWeL1MJQ3DBjBgmH10KE-DZTC6BydhMHse5hHWV7Rijx4_j4mIGnOBxGU0JccJhwj4YCyW4miwBppLxy99_eEhxjS34HDw0ZTMDLhE_gUnGjrvBCToYzJjh874fo4efPx6ubpq7--vbq8u7xomWlYZ3A3UECPF8EMJzrwZJB2e9MsZxIb2yxLu-8wycVYJzZk2nWiF7A8x2_Bh9262dU_y9QC56HbKDcTQTxCVrKSXrGeXVKHZGl2LOCQY9p_p82mhK9Ja63iLVW6RaCf1GXbc19nW_f7Fr8O-hPeaqX-x0qD_-CZB0dhWTAx8SuKJ9DP8_8AqmrJU9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77728213</pqid></control><display><type>article</type><title>Artificial endocrine pancreas and optimal blood glucose regulation in diabetic patients — from bedside-type to wearable-type</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Shichiri, Motoaki ; Kishikawa, Hideki ; Sakakida, Michiharu ; Kajiwara, Kenichiro ; Hashiguchi, Yasuhiro ; Nishida, Kenro ; Uemura, Takero ; Konno, Yumi ; Ichinose, Kenshi</creator><creatorcontrib>Shichiri, Motoaki ; Kishikawa, Hideki ; Sakakida, Michiharu ; Kajiwara, Kenichiro ; Hashiguchi, Yasuhiro ; Nishida, Kenro ; Uemura, Takero ; Konno, Yumi ; Ichinose, Kenshi</creatorcontrib><description>The artificial endocrine pancreas is a feedback control system regulating insulin delivery on a minute-by-minute basis according to the measured blood glucose levels. The bedside-type artificial endocrine pancreas has been proven to be useful not only as a therapeutic tool for diabetes mellitus but also as an elegant research tool for investigating the pathophysiology of the disease. With significant advances in the development of a subcutaneous tissue glucose monitoring system, the wearable-type artificial endocrine pancreas has been applied to diabetic patients. With this system, perfect glycemic control can be obtained for longer periods in ambulatory diabetic patients. The trend in the development of the artificial endocrine pancreas is now directed to implantable devices. Much efforts have been conducted to realize these devices.</description><identifier>ISSN: 0168-8227</identifier><identifier>EISSN: 1872-8227</identifier><identifier>DOI: 10.1016/0168-8227(94)90258-5</identifier><identifier>PMID: 7859615</identifier><language>eng</language><publisher>Ireland: Elsevier Ireland Ltd</publisher><subject>Bedside-type artificial endocrine pancreas ; Biocompatible membrane ; Blood Glucose - analysis ; Blood Glucose Self-Monitoring ; Diabetes Mellitus - blood ; Diabetes Mellitus - drug therapy ; Diabetes Mellitus - epidemiology ; Humans ; Infusion Pumps, Implantable ; Insulin - administration & dosage ; Insulin - therapeutic use ; Insulin Infusion Systems - standards ; Insulin Infusion Systems - trends ; Japan - epidemiology ; Microdialysis sampling method ; Needle-type glucose sensor ; Wearable-type artificial endocrine pancreas</subject><ispartof>Diabetes research and clinical practice, 1994-10, Vol.24, p.S251-S259</ispartof><rights>1994</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c452t-36f1c0e00d3f44d3d9f71fcbd9aac347d9b0dc86d2ecb94332ba695478ae2b63</citedby><cites>FETCH-LOGICAL-c452t-36f1c0e00d3f44d3d9f71fcbd9aac347d9b0dc86d2ecb94332ba695478ae2b63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0168-8227(94)90258-5$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,45974</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7859615$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shichiri, Motoaki</creatorcontrib><creatorcontrib>Kishikawa, Hideki</creatorcontrib><creatorcontrib>Sakakida, Michiharu</creatorcontrib><creatorcontrib>Kajiwara, Kenichiro</creatorcontrib><creatorcontrib>Hashiguchi, Yasuhiro</creatorcontrib><creatorcontrib>Nishida, Kenro</creatorcontrib><creatorcontrib>Uemura, Takero</creatorcontrib><creatorcontrib>Konno, Yumi</creatorcontrib><creatorcontrib>Ichinose, Kenshi</creatorcontrib><title>Artificial endocrine pancreas and optimal blood glucose regulation in diabetic patients — from bedside-type to wearable-type</title><title>Diabetes research and clinical practice</title><addtitle>Diabetes Res Clin Pract</addtitle><description>The artificial endocrine pancreas is a feedback control system regulating insulin delivery on a minute-by-minute basis according to the measured blood glucose levels. The bedside-type artificial endocrine pancreas has been proven to be useful not only as a therapeutic tool for diabetes mellitus but also as an elegant research tool for investigating the pathophysiology of the disease. With significant advances in the development of a subcutaneous tissue glucose monitoring system, the wearable-type artificial endocrine pancreas has been applied to diabetic patients. With this system, perfect glycemic control can be obtained for longer periods in ambulatory diabetic patients. The trend in the development of the artificial endocrine pancreas is now directed to implantable devices. Much efforts have been conducted to realize these devices.</description><subject>Bedside-type artificial endocrine pancreas</subject><subject>Biocompatible membrane</subject><subject>Blood Glucose - analysis</subject><subject>Blood Glucose Self-Monitoring</subject><subject>Diabetes Mellitus - blood</subject><subject>Diabetes Mellitus - drug therapy</subject><subject>Diabetes Mellitus - epidemiology</subject><subject>Humans</subject><subject>Infusion Pumps, Implantable</subject><subject>Insulin - administration & dosage</subject><subject>Insulin - therapeutic use</subject><subject>Insulin Infusion Systems - standards</subject><subject>Insulin Infusion Systems - trends</subject><subject>Japan - epidemiology</subject><subject>Microdialysis sampling method</subject><subject>Needle-type glucose sensor</subject><subject>Wearable-type artificial endocrine pancreas</subject><issn>0168-8227</issn><issn>1872-8227</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kM1KHUEQhZsQMVfNGyTQqxAXo_0309MbQSRRQXDjvumfGukwd3rS3RO5G8lD5Al9Evt6Ly6zKArqnFNFfQh9oeSMEtqd1-qbnjH5XYlTRVjbN-0HtKK9ZG_jj2j1bvmEjnL-RQjpuGgP0aHsW9XRdoWeL1MJQ3DBjBgmH10KE-DZTC6BydhMHse5hHWV7Rijx4_j4mIGnOBxGU0JccJhwj4YCyW4miwBppLxy99_eEhxjS34HDw0ZTMDLhE_gUnGjrvBCToYzJjh874fo4efPx6ubpq7--vbq8u7xomWlYZ3A3UECPF8EMJzrwZJB2e9MsZxIb2yxLu-8wycVYJzZk2nWiF7A8x2_Bh9262dU_y9QC56HbKDcTQTxCVrKSXrGeXVKHZGl2LOCQY9p_p82mhK9Ja63iLVW6RaCf1GXbc19nW_f7Fr8O-hPeaqX-x0qD_-CZB0dhWTAx8SuKJ9DP8_8AqmrJU9</recordid><startdate>19941001</startdate><enddate>19941001</enddate><creator>Shichiri, Motoaki</creator><creator>Kishikawa, Hideki</creator><creator>Sakakida, Michiharu</creator><creator>Kajiwara, Kenichiro</creator><creator>Hashiguchi, Yasuhiro</creator><creator>Nishida, Kenro</creator><creator>Uemura, Takero</creator><creator>Konno, Yumi</creator><creator>Ichinose, Kenshi</creator><general>Elsevier Ireland Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19941001</creationdate><title>Artificial endocrine pancreas and optimal blood glucose regulation in diabetic patients — from bedside-type to wearable-type</title><author>Shichiri, Motoaki ; Kishikawa, Hideki ; Sakakida, Michiharu ; Kajiwara, Kenichiro ; Hashiguchi, Yasuhiro ; Nishida, Kenro ; Uemura, Takero ; Konno, Yumi ; Ichinose, Kenshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c452t-36f1c0e00d3f44d3d9f71fcbd9aac347d9b0dc86d2ecb94332ba695478ae2b63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Bedside-type artificial endocrine pancreas</topic><topic>Biocompatible membrane</topic><topic>Blood Glucose - analysis</topic><topic>Blood Glucose Self-Monitoring</topic><topic>Diabetes Mellitus - blood</topic><topic>Diabetes Mellitus - drug therapy</topic><topic>Diabetes Mellitus - epidemiology</topic><topic>Humans</topic><topic>Infusion Pumps, Implantable</topic><topic>Insulin - administration & dosage</topic><topic>Insulin - therapeutic use</topic><topic>Insulin Infusion Systems - standards</topic><topic>Insulin Infusion Systems - trends</topic><topic>Japan - epidemiology</topic><topic>Microdialysis sampling method</topic><topic>Needle-type glucose sensor</topic><topic>Wearable-type artificial endocrine pancreas</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shichiri, Motoaki</creatorcontrib><creatorcontrib>Kishikawa, Hideki</creatorcontrib><creatorcontrib>Sakakida, Michiharu</creatorcontrib><creatorcontrib>Kajiwara, Kenichiro</creatorcontrib><creatorcontrib>Hashiguchi, Yasuhiro</creatorcontrib><creatorcontrib>Nishida, Kenro</creatorcontrib><creatorcontrib>Uemura, Takero</creatorcontrib><creatorcontrib>Konno, Yumi</creatorcontrib><creatorcontrib>Ichinose, Kenshi</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Diabetes research and clinical practice</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shichiri, Motoaki</au><au>Kishikawa, Hideki</au><au>Sakakida, Michiharu</au><au>Kajiwara, Kenichiro</au><au>Hashiguchi, Yasuhiro</au><au>Nishida, Kenro</au><au>Uemura, Takero</au><au>Konno, Yumi</au><au>Ichinose, Kenshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Artificial endocrine pancreas and optimal blood glucose regulation in diabetic patients — from bedside-type to wearable-type</atitle><jtitle>Diabetes research and clinical practice</jtitle><addtitle>Diabetes Res Clin Pract</addtitle><date>1994-10-01</date><risdate>1994</risdate><volume>24</volume><spage>S251</spage><epage>S259</epage><pages>S251-S259</pages><issn>0168-8227</issn><eissn>1872-8227</eissn><abstract>The artificial endocrine pancreas is a feedback control system regulating insulin delivery on a minute-by-minute basis according to the measured blood glucose levels. The bedside-type artificial endocrine pancreas has been proven to be useful not only as a therapeutic tool for diabetes mellitus but also as an elegant research tool for investigating the pathophysiology of the disease. With significant advances in the development of a subcutaneous tissue glucose monitoring system, the wearable-type artificial endocrine pancreas has been applied to diabetic patients. With this system, perfect glycemic control can be obtained for longer periods in ambulatory diabetic patients. The trend in the development of the artificial endocrine pancreas is now directed to implantable devices. Much efforts have been conducted to realize these devices.</abstract><cop>Ireland</cop><pub>Elsevier Ireland Ltd</pub><pmid>7859615</pmid><doi>10.1016/0168-8227(94)90258-5</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0168-8227 |
ispartof | Diabetes research and clinical practice, 1994-10, Vol.24, p.S251-S259 |
issn | 0168-8227 1872-8227 |
language | eng |
recordid | cdi_proquest_miscellaneous_77728213 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Bedside-type artificial endocrine pancreas Biocompatible membrane Blood Glucose - analysis Blood Glucose Self-Monitoring Diabetes Mellitus - blood Diabetes Mellitus - drug therapy Diabetes Mellitus - epidemiology Humans Infusion Pumps, Implantable Insulin - administration & dosage Insulin - therapeutic use Insulin Infusion Systems - standards Insulin Infusion Systems - trends Japan - epidemiology Microdialysis sampling method Needle-type glucose sensor Wearable-type artificial endocrine pancreas |
title | Artificial endocrine pancreas and optimal blood glucose regulation in diabetic patients — from bedside-type to wearable-type |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T05%3A46%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Artificial%20endocrine%20pancreas%20and%20optimal%20blood%20glucose%20regulation%20in%20diabetic%20patients%20%E2%80%94%20from%20bedside-type%20to%20wearable-type&rft.jtitle=Diabetes%20research%20and%20clinical%20practice&rft.au=Shichiri,%20Motoaki&rft.date=1994-10-01&rft.volume=24&rft.spage=S251&rft.epage=S259&rft.pages=S251-S259&rft.issn=0168-8227&rft.eissn=1872-8227&rft_id=info:doi/10.1016/0168-8227(94)90258-5&rft_dat=%3Cproquest_cross%3E77728213%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77728213&rft_id=info:pmid/7859615&rft_els_id=0168822794902585&rfr_iscdi=true |