Noninvasive, automatic 24-h ambulatory blood pressure monitoring in normotensive subjects
The reliability of noninvasive, automatic blood pressure monitoring is not yet clearly established. A 24-h ambulatory blood pressure profile was obtained in 9 healthy, normotensive subjects with an automatic, noninvasive device. The blood pressure profile showed the typical circadian pattern with lo...
Gespeichert in:
Veröffentlicht in: | European Journal of Applied Physiology and Occupational Physiology 1987-07, Vol.56 (4), p.381-383 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 383 |
---|---|
container_issue | 4 |
container_start_page | 381 |
container_title | European Journal of Applied Physiology and Occupational Physiology |
container_volume | 56 |
creator | SUNDBERG, S |
description | The reliability of noninvasive, automatic blood pressure monitoring is not yet clearly established. A 24-h ambulatory blood pressure profile was obtained in 9 healthy, normotensive subjects with an automatic, noninvasive device. The blood pressure profile showed the typical circadian pattern with lower systolic and diastolic values during sleep, although pulse pressure was fairly constant (about 40 mm Hg). The systolic blood pressure rose steeply in the early morning hours--before waking up. The results were compared with simultaneous hourly readings using the auscultatory method. There were no statistically significant differences between the automatic and auscultatory readings, 13 of the 18 mean values at different time points being within 2 mm Hg of each other. All the auscultatory means fell within the 95% confidence limits of those measured hourly by the automatic method. Although the automatic method seemed to be reliable compared with the auscultatory method, its sensitivity to motion artifacts is a disadvantage in a truly ambulatory setting. |
doi_str_mv | 10.1007/bf00417763 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77664061</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77664061</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-8f404e7da365222db5d139e410bc6c167f34ce5a8d336682ee367a977d9972df3</originalsourceid><addsrcrecordid>eNo9kD1PwzAQhi0EKqWwsCN5QAyIgL9iJyNUFJAqWGBgihz7Aq6SuNhJpf57UjVwy0n3PvcOD0LnlNxSQtRdWREiqFKSH6ApFZwllLD0EE0JJzRJU5Edo5MYV4QwknM1QRMuGRMqn6LPV9-6dqOj28AN1n3nG905g5lIvrFuyr7WnQ9bXNbeW7wOEGMfADfD13B37Rd2LW59aHwH7a4Ex75cgeniKTqqdB3hbNwz9LF4fJ8_J8u3p5f5_TIxXKkuySpBBCiruUwZY7ZMLeU5CEpKIw2VquLCQKozy7mUGQPgUulcKZvnitmKz9DVvncd_E8PsSsaFw3UtW7B97EYtEhBJB3A6z1ogo8xQFWsg2t02BaUFDuPxcPiz-MAX4ytfdmA_UdHcUN-OeY6Gl1XQbfGxX9MCZ7xYX4Bf9d6bA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77664061</pqid></control><display><type>article</type><title>Noninvasive, automatic 24-h ambulatory blood pressure monitoring in normotensive subjects</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>SUNDBERG, S</creator><creatorcontrib>SUNDBERG, S</creatorcontrib><description>The reliability of noninvasive, automatic blood pressure monitoring is not yet clearly established. A 24-h ambulatory blood pressure profile was obtained in 9 healthy, normotensive subjects with an automatic, noninvasive device. The blood pressure profile showed the typical circadian pattern with lower systolic and diastolic values during sleep, although pulse pressure was fairly constant (about 40 mm Hg). The systolic blood pressure rose steeply in the early morning hours--before waking up. The results were compared with simultaneous hourly readings using the auscultatory method. There were no statistically significant differences between the automatic and auscultatory readings, 13 of the 18 mean values at different time points being within 2 mm Hg of each other. All the auscultatory means fell within the 95% confidence limits of those measured hourly by the automatic method. Although the automatic method seemed to be reliable compared with the auscultatory method, its sensitivity to motion artifacts is a disadvantage in a truly ambulatory setting.</description><identifier>ISSN: 0301-5548</identifier><identifier>EISSN: 1432-1025</identifier><identifier>EISSN: 1439-6327</identifier><identifier>DOI: 10.1007/bf00417763</identifier><identifier>PMID: 3622479</identifier><identifier>CODEN: EJAPCK</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Adult ; Biological and medical sciences ; Blood Pressure ; Blood Pressure Determination - methods ; Cardiovascular system ; Circadian Rhythm ; Female ; Humans ; Investigative techniques of hemodynamics ; Investigative techniques, diagnostic techniques (general aspects) ; Male ; Medical sciences</subject><ispartof>European Journal of Applied Physiology and Occupational Physiology, 1987-07, Vol.56 (4), p.381-383</ispartof><rights>1988 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-8f404e7da365222db5d139e410bc6c167f34ce5a8d336682ee367a977d9972df3</citedby><cites>FETCH-LOGICAL-c377t-8f404e7da365222db5d139e410bc6c167f34ce5a8d336682ee367a977d9972df3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=7438333$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/3622479$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>SUNDBERG, S</creatorcontrib><title>Noninvasive, automatic 24-h ambulatory blood pressure monitoring in normotensive subjects</title><title>European Journal of Applied Physiology and Occupational Physiology</title><addtitle>Eur J Appl Physiol Occup Physiol</addtitle><description>The reliability of noninvasive, automatic blood pressure monitoring is not yet clearly established. A 24-h ambulatory blood pressure profile was obtained in 9 healthy, normotensive subjects with an automatic, noninvasive device. The blood pressure profile showed the typical circadian pattern with lower systolic and diastolic values during sleep, although pulse pressure was fairly constant (about 40 mm Hg). The systolic blood pressure rose steeply in the early morning hours--before waking up. The results were compared with simultaneous hourly readings using the auscultatory method. There were no statistically significant differences between the automatic and auscultatory readings, 13 of the 18 mean values at different time points being within 2 mm Hg of each other. All the auscultatory means fell within the 95% confidence limits of those measured hourly by the automatic method. Although the automatic method seemed to be reliable compared with the auscultatory method, its sensitivity to motion artifacts is a disadvantage in a truly ambulatory setting.</description><subject>Adult</subject><subject>Biological and medical sciences</subject><subject>Blood Pressure</subject><subject>Blood Pressure Determination - methods</subject><subject>Cardiovascular system</subject><subject>Circadian Rhythm</subject><subject>Female</subject><subject>Humans</subject><subject>Investigative techniques of hemodynamics</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Male</subject><subject>Medical sciences</subject><issn>0301-5548</issn><issn>1432-1025</issn><issn>1439-6327</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1987</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kD1PwzAQhi0EKqWwsCN5QAyIgL9iJyNUFJAqWGBgihz7Aq6SuNhJpf57UjVwy0n3PvcOD0LnlNxSQtRdWREiqFKSH6ApFZwllLD0EE0JJzRJU5Edo5MYV4QwknM1QRMuGRMqn6LPV9-6dqOj28AN1n3nG905g5lIvrFuyr7WnQ9bXNbeW7wOEGMfADfD13B37Rd2LW59aHwH7a4Ex75cgeniKTqqdB3hbNwz9LF4fJ8_J8u3p5f5_TIxXKkuySpBBCiruUwZY7ZMLeU5CEpKIw2VquLCQKozy7mUGQPgUulcKZvnitmKz9DVvncd_E8PsSsaFw3UtW7B97EYtEhBJB3A6z1ogo8xQFWsg2t02BaUFDuPxcPiz-MAX4ytfdmA_UdHcUN-OeY6Gl1XQbfGxX9MCZ7xYX4Bf9d6bA</recordid><startdate>198707</startdate><enddate>198707</enddate><creator>SUNDBERG, S</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198707</creationdate><title>Noninvasive, automatic 24-h ambulatory blood pressure monitoring in normotensive subjects</title><author>SUNDBERG, S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-8f404e7da365222db5d139e410bc6c167f34ce5a8d336682ee367a977d9972df3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1987</creationdate><topic>Adult</topic><topic>Biological and medical sciences</topic><topic>Blood Pressure</topic><topic>Blood Pressure Determination - methods</topic><topic>Cardiovascular system</topic><topic>Circadian Rhythm</topic><topic>Female</topic><topic>Humans</topic><topic>Investigative techniques of hemodynamics</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Male</topic><topic>Medical sciences</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>SUNDBERG, S</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European Journal of Applied Physiology and Occupational Physiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SUNDBERG, S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Noninvasive, automatic 24-h ambulatory blood pressure monitoring in normotensive subjects</atitle><jtitle>European Journal of Applied Physiology and Occupational Physiology</jtitle><addtitle>Eur J Appl Physiol Occup Physiol</addtitle><date>1987-07</date><risdate>1987</risdate><volume>56</volume><issue>4</issue><spage>381</spage><epage>383</epage><pages>381-383</pages><issn>0301-5548</issn><eissn>1432-1025</eissn><eissn>1439-6327</eissn><coden>EJAPCK</coden><abstract>The reliability of noninvasive, automatic blood pressure monitoring is not yet clearly established. A 24-h ambulatory blood pressure profile was obtained in 9 healthy, normotensive subjects with an automatic, noninvasive device. The blood pressure profile showed the typical circadian pattern with lower systolic and diastolic values during sleep, although pulse pressure was fairly constant (about 40 mm Hg). The systolic blood pressure rose steeply in the early morning hours--before waking up. The results were compared with simultaneous hourly readings using the auscultatory method. There were no statistically significant differences between the automatic and auscultatory readings, 13 of the 18 mean values at different time points being within 2 mm Hg of each other. All the auscultatory means fell within the 95% confidence limits of those measured hourly by the automatic method. Although the automatic method seemed to be reliable compared with the auscultatory method, its sensitivity to motion artifacts is a disadvantage in a truly ambulatory setting.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>3622479</pmid><doi>10.1007/bf00417763</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0301-5548 |
ispartof | European Journal of Applied Physiology and Occupational Physiology, 1987-07, Vol.56 (4), p.381-383 |
issn | 0301-5548 1432-1025 1439-6327 |
language | eng |
recordid | cdi_proquest_miscellaneous_77664061 |
source | MEDLINE; SpringerLink Journals - AutoHoldings |
subjects | Adult Biological and medical sciences Blood Pressure Blood Pressure Determination - methods Cardiovascular system Circadian Rhythm Female Humans Investigative techniques of hemodynamics Investigative techniques, diagnostic techniques (general aspects) Male Medical sciences |
title | Noninvasive, automatic 24-h ambulatory blood pressure monitoring in normotensive subjects |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T15%3A59%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Noninvasive,%20automatic%2024-h%20ambulatory%20blood%20pressure%20monitoring%20in%20normotensive%20subjects&rft.jtitle=European%20Journal%20of%20Applied%20Physiology%20and%20Occupational%20Physiology&rft.au=SUNDBERG,%20S&rft.date=1987-07&rft.volume=56&rft.issue=4&rft.spage=381&rft.epage=383&rft.pages=381-383&rft.issn=0301-5548&rft.eissn=1432-1025&rft.coden=EJAPCK&rft_id=info:doi/10.1007/bf00417763&rft_dat=%3Cproquest_cross%3E77664061%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77664061&rft_id=info:pmid/3622479&rfr_iscdi=true |