In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses
The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles in vivo. The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyu...
Gespeichert in:
Veröffentlicht in: | European journal of vascular and endovascular surgery 1995-08, Vol.10 (2), p.168-181 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 181 |
---|---|
container_issue | 2 |
container_start_page | 168 |
container_title | European journal of vascular and endovascular surgery |
container_volume | 10 |
creator | Staalsen, N.H. Ulrich, M. Kim, W.Y. Pedersen, E.M. How, T.V. Hasenkam, J.M. |
description | The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles
in vivo.
The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyurethane graft. Three anastomosis angles: 90° (
n = 3), 45° (
n = 3) and 15° (
n = 4) were studied. The bypass length, the anatomical position and the geometry of the anastomoses were standardised. During measurements, the proximal outflow segment was occluded and the flow rate was controlled by reversible iliac artery cross-clamping. Using a colour Doppler system the velocity fields were measured at various positions in the anatomosis. The colour Doppler velocity data were transferred to a computer for dynamic three-dimensional visualisation of the velocity profiles.
The angulation was reproduced within 10%. During the experiment, the flow rate was kept constant with Reynold's numbers typical for peripheral arteries. In the 90° anastomoses very disturbed flow fields were seen. The 45° anastomoses were characterised by: (1) low antegrade and retrograde velocities at the heel and (2) a zone of reverse and oscillating velocities at the toe and at one diameter downstream of the toe (1DDD) during deceleration. In the 15° anastomoses no flow disturbances were seen either at the toe or at 1DDD. The velocity profiles were close to parabolic at peak flow at both positions.
It is concluded that the 15° anastomosis is preferable from a haemodynamic point of view. |
doi_str_mv | 10.1016/S1078-5884(05)80108-X |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77495623</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S107858840580108X</els_id><sourcerecordid>77495623</sourcerecordid><originalsourceid>FETCH-LOGICAL-c322x-699b876295f1fe4eda4dfe3a7130d97b1b994455bdbec8834224a1475c2f26ca3</originalsourceid><addsrcrecordid>eNqFkE9v1DAQxS0EakvLR6jkE4KDwXbsxDlV1Yo_lSpxgEq9WY49EUZJvPU4W_rt8XYXrpxmRu-9Gc2PkEvBPwgu2o_fBe8M08aod1y_N1xww-5fkDOhG8mkaPXL2v-1nJLXiL8451o0-oScdK3WfWvOSLpZ6C7uEnWLm54wYm0CLT8zAAtxhgVjqkr14OqmiK7UmaaRDlNKgY5TeqRbVwrkpUYL3Tn06-QyhSWwkhjGAPvdWNKcEPCCvBrdhPDmWM_J3edPPzZf2e23Lzeb61vmGyl_s7bvB9O1stejGEFBcCqM0LhONDz03SCGvldK6yEM4I1plJTKCdVpL0fZeteck7eHvducHlbAYueIHqbJLZBWtF2net3Kphr1wehzQsww2m2Os8tPVnC7B22fQds9Rcu1fQZt72vu8nhgHWYI_1JHslW_OuhQv9xFyBZ9hMVDiBl8sSHF_1z4A9F8j_g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77495623</pqid></control><display><type>article</type><title>In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Staalsen, N.H. ; Ulrich, M. ; Kim, W.Y. ; Pedersen, E.M. ; How, T.V. ; Hasenkam, J.M.</creator><creatorcontrib>Staalsen, N.H. ; Ulrich, M. ; Kim, W.Y. ; Pedersen, E.M. ; How, T.V. ; Hasenkam, J.M.</creatorcontrib><description>The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles
in vivo.
The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyurethane graft. Three anastomosis angles: 90° (
n = 3), 45° (
n = 3) and 15° (
n = 4) were studied. The bypass length, the anatomical position and the geometry of the anastomoses were standardised. During measurements, the proximal outflow segment was occluded and the flow rate was controlled by reversible iliac artery cross-clamping. Using a colour Doppler system the velocity fields were measured at various positions in the anatomosis. The colour Doppler velocity data were transferred to a computer for dynamic three-dimensional visualisation of the velocity profiles.
The angulation was reproduced within 10%. During the experiment, the flow rate was kept constant with Reynold's numbers typical for peripheral arteries. In the 90° anastomoses very disturbed flow fields were seen. The 45° anastomoses were characterised by: (1) low antegrade and retrograde velocities at the heel and (2) a zone of reverse and oscillating velocities at the toe and at one diameter downstream of the toe (1DDD) during deceleration. In the 15° anastomoses no flow disturbances were seen either at the toe or at 1DDD. The velocity profiles were close to parabolic at peak flow at both positions.
It is concluded that the 15° anastomosis is preferable from a haemodynamic point of view.</description><identifier>ISSN: 1078-5884</identifier><identifier>EISSN: 1532-2165</identifier><identifier>DOI: 10.1016/S1078-5884(05)80108-X</identifier><identifier>PMID: 7655968</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Anastomosis angle ; Anastomosis, Surgical - methods ; Animals ; Aorta, Abdominal - surgery ; Blood Flow Velocity ; Blood velocity ; Blood Vessel Prosthesis ; Colour Doppler ultrasound ; Pigs ; Polyurethanes ; Swine ; Ultrasonography, Doppler, Color ; Vascular anastomosis ; Vascular Surgical Procedures - methods</subject><ispartof>European journal of vascular and endovascular surgery, 1995-08, Vol.10 (2), p.168-181</ispartof><rights>1995 W. B. Saunders Company Ltd. All rights reserved</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c322x-699b876295f1fe4eda4dfe3a7130d97b1b994455bdbec8834224a1475c2f26ca3</citedby><cites>FETCH-LOGICAL-c322x-699b876295f1fe4eda4dfe3a7130d97b1b994455bdbec8834224a1475c2f26ca3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S1078-5884(05)80108-X$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7655968$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Staalsen, N.H.</creatorcontrib><creatorcontrib>Ulrich, M.</creatorcontrib><creatorcontrib>Kim, W.Y.</creatorcontrib><creatorcontrib>Pedersen, E.M.</creatorcontrib><creatorcontrib>How, T.V.</creatorcontrib><creatorcontrib>Hasenkam, J.M.</creatorcontrib><title>In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses</title><title>European journal of vascular and endovascular surgery</title><addtitle>Eur J Vasc Endovasc Surg</addtitle><description>The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles
in vivo.
The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyurethane graft. Three anastomosis angles: 90° (
n = 3), 45° (
n = 3) and 15° (
n = 4) were studied. The bypass length, the anatomical position and the geometry of the anastomoses were standardised. During measurements, the proximal outflow segment was occluded and the flow rate was controlled by reversible iliac artery cross-clamping. Using a colour Doppler system the velocity fields were measured at various positions in the anatomosis. The colour Doppler velocity data were transferred to a computer for dynamic three-dimensional visualisation of the velocity profiles.
The angulation was reproduced within 10%. During the experiment, the flow rate was kept constant with Reynold's numbers typical for peripheral arteries. In the 90° anastomoses very disturbed flow fields were seen. The 45° anastomoses were characterised by: (1) low antegrade and retrograde velocities at the heel and (2) a zone of reverse and oscillating velocities at the toe and at one diameter downstream of the toe (1DDD) during deceleration. In the 15° anastomoses no flow disturbances were seen either at the toe or at 1DDD. The velocity profiles were close to parabolic at peak flow at both positions.
It is concluded that the 15° anastomosis is preferable from a haemodynamic point of view.</description><subject>Anastomosis angle</subject><subject>Anastomosis, Surgical - methods</subject><subject>Animals</subject><subject>Aorta, Abdominal - surgery</subject><subject>Blood Flow Velocity</subject><subject>Blood velocity</subject><subject>Blood Vessel Prosthesis</subject><subject>Colour Doppler ultrasound</subject><subject>Pigs</subject><subject>Polyurethanes</subject><subject>Swine</subject><subject>Ultrasonography, Doppler, Color</subject><subject>Vascular anastomosis</subject><subject>Vascular Surgical Procedures - methods</subject><issn>1078-5884</issn><issn>1532-2165</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE9v1DAQxS0EakvLR6jkE4KDwXbsxDlV1Yo_lSpxgEq9WY49EUZJvPU4W_rt8XYXrpxmRu-9Gc2PkEvBPwgu2o_fBe8M08aod1y_N1xww-5fkDOhG8mkaPXL2v-1nJLXiL8451o0-oScdK3WfWvOSLpZ6C7uEnWLm54wYm0CLT8zAAtxhgVjqkr14OqmiK7UmaaRDlNKgY5TeqRbVwrkpUYL3Tn06-QyhSWwkhjGAPvdWNKcEPCCvBrdhPDmWM_J3edPPzZf2e23Lzeb61vmGyl_s7bvB9O1stejGEFBcCqM0LhONDz03SCGvldK6yEM4I1plJTKCdVpL0fZeteck7eHvducHlbAYueIHqbJLZBWtF2net3Kphr1wehzQsww2m2Os8tPVnC7B22fQds9Rcu1fQZt72vu8nhgHWYI_1JHslW_OuhQv9xFyBZ9hMVDiBl8sSHF_1z4A9F8j_g</recordid><startdate>199508</startdate><enddate>199508</enddate><creator>Staalsen, N.H.</creator><creator>Ulrich, M.</creator><creator>Kim, W.Y.</creator><creator>Pedersen, E.M.</creator><creator>How, T.V.</creator><creator>Hasenkam, J.M.</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199508</creationdate><title>In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses</title><author>Staalsen, N.H. ; Ulrich, M. ; Kim, W.Y. ; Pedersen, E.M. ; How, T.V. ; Hasenkam, J.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c322x-699b876295f1fe4eda4dfe3a7130d97b1b994455bdbec8834224a1475c2f26ca3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Anastomosis angle</topic><topic>Anastomosis, Surgical - methods</topic><topic>Animals</topic><topic>Aorta, Abdominal - surgery</topic><topic>Blood Flow Velocity</topic><topic>Blood velocity</topic><topic>Blood Vessel Prosthesis</topic><topic>Colour Doppler ultrasound</topic><topic>Pigs</topic><topic>Polyurethanes</topic><topic>Swine</topic><topic>Ultrasonography, Doppler, Color</topic><topic>Vascular anastomosis</topic><topic>Vascular Surgical Procedures - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Staalsen, N.H.</creatorcontrib><creatorcontrib>Ulrich, M.</creatorcontrib><creatorcontrib>Kim, W.Y.</creatorcontrib><creatorcontrib>Pedersen, E.M.</creatorcontrib><creatorcontrib>How, T.V.</creatorcontrib><creatorcontrib>Hasenkam, J.M.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of vascular and endovascular surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Staalsen, N.H.</au><au>Ulrich, M.</au><au>Kim, W.Y.</au><au>Pedersen, E.M.</au><au>How, T.V.</au><au>Hasenkam, J.M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses</atitle><jtitle>European journal of vascular and endovascular surgery</jtitle><addtitle>Eur J Vasc Endovasc Surg</addtitle><date>1995-08</date><risdate>1995</risdate><volume>10</volume><issue>2</issue><spage>168</spage><epage>181</epage><pages>168-181</pages><issn>1078-5884</issn><eissn>1532-2165</eissn><abstract>The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles
in vivo.
The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyurethane graft. Three anastomosis angles: 90° (
n = 3), 45° (
n = 3) and 15° (
n = 4) were studied. The bypass length, the anatomical position and the geometry of the anastomoses were standardised. During measurements, the proximal outflow segment was occluded and the flow rate was controlled by reversible iliac artery cross-clamping. Using a colour Doppler system the velocity fields were measured at various positions in the anatomosis. The colour Doppler velocity data were transferred to a computer for dynamic three-dimensional visualisation of the velocity profiles.
The angulation was reproduced within 10%. During the experiment, the flow rate was kept constant with Reynold's numbers typical for peripheral arteries. In the 90° anastomoses very disturbed flow fields were seen. The 45° anastomoses were characterised by: (1) low antegrade and retrograde velocities at the heel and (2) a zone of reverse and oscillating velocities at the toe and at one diameter downstream of the toe (1DDD) during deceleration. In the 15° anastomoses no flow disturbances were seen either at the toe or at 1DDD. The velocity profiles were close to parabolic at peak flow at both positions.
It is concluded that the 15° anastomosis is preferable from a haemodynamic point of view.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>7655968</pmid><doi>10.1016/S1078-5884(05)80108-X</doi><tpages>14</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1078-5884 |
ispartof | European journal of vascular and endovascular surgery, 1995-08, Vol.10 (2), p.168-181 |
issn | 1078-5884 1532-2165 |
language | eng |
recordid | cdi_proquest_miscellaneous_77495623 |
source | MEDLINE; ScienceDirect Journals (5 years ago - present); EZB-FREE-00999 freely available EZB journals |
subjects | Anastomosis angle Anastomosis, Surgical - methods Animals Aorta, Abdominal - surgery Blood Flow Velocity Blood velocity Blood Vessel Prosthesis Colour Doppler ultrasound Pigs Polyurethanes Swine Ultrasonography, Doppler, Color Vascular anastomosis Vascular Surgical Procedures - methods |
title | In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T01%3A15%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20vivo%20analysis%20and%20three-dimensional%20visualisation%20of%20blood%20flow%20patterns%20at%20vascular%20end-to-side%20anastomoses&rft.jtitle=European%20journal%20of%20vascular%20and%20endovascular%20surgery&rft.au=Staalsen,%20N.H.&rft.date=1995-08&rft.volume=10&rft.issue=2&rft.spage=168&rft.epage=181&rft.pages=168-181&rft.issn=1078-5884&rft.eissn=1532-2165&rft_id=info:doi/10.1016/S1078-5884(05)80108-X&rft_dat=%3Cproquest_cross%3E77495623%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77495623&rft_id=info:pmid/7655968&rft_els_id=S107858840580108X&rfr_iscdi=true |