In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses

The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles in vivo. The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of vascular and endovascular surgery 1995-08, Vol.10 (2), p.168-181
Hauptverfasser: Staalsen, N.H., Ulrich, M., Kim, W.Y., Pedersen, E.M., How, T.V., Hasenkam, J.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 181
container_issue 2
container_start_page 168
container_title European journal of vascular and endovascular surgery
container_volume 10
creator Staalsen, N.H.
Ulrich, M.
Kim, W.Y.
Pedersen, E.M.
How, T.V.
Hasenkam, J.M.
description The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles in vivo. The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyurethane graft. Three anastomosis angles: 90° ( n = 3), 45° ( n = 3) and 15° ( n = 4) were studied. The bypass length, the anatomical position and the geometry of the anastomoses were standardised. During measurements, the proximal outflow segment was occluded and the flow rate was controlled by reversible iliac artery cross-clamping. Using a colour Doppler system the velocity fields were measured at various positions in the anatomosis. The colour Doppler velocity data were transferred to a computer for dynamic three-dimensional visualisation of the velocity profiles. The angulation was reproduced within 10%. During the experiment, the flow rate was kept constant with Reynold's numbers typical for peripheral arteries. In the 90° anastomoses very disturbed flow fields were seen. The 45° anastomoses were characterised by: (1) low antegrade and retrograde velocities at the heel and (2) a zone of reverse and oscillating velocities at the toe and at one diameter downstream of the toe (1DDD) during deceleration. In the 15° anastomoses no flow disturbances were seen either at the toe or at 1DDD. The velocity profiles were close to parabolic at peak flow at both positions. It is concluded that the 15° anastomosis is preferable from a haemodynamic point of view.
doi_str_mv 10.1016/S1078-5884(05)80108-X
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77495623</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S107858840580108X</els_id><sourcerecordid>77495623</sourcerecordid><originalsourceid>FETCH-LOGICAL-c322x-699b876295f1fe4eda4dfe3a7130d97b1b994455bdbec8834224a1475c2f26ca3</originalsourceid><addsrcrecordid>eNqFkE9v1DAQxS0EakvLR6jkE4KDwXbsxDlV1Yo_lSpxgEq9WY49EUZJvPU4W_rt8XYXrpxmRu-9Gc2PkEvBPwgu2o_fBe8M08aod1y_N1xww-5fkDOhG8mkaPXL2v-1nJLXiL8451o0-oScdK3WfWvOSLpZ6C7uEnWLm54wYm0CLT8zAAtxhgVjqkr14OqmiK7UmaaRDlNKgY5TeqRbVwrkpUYL3Tn06-QyhSWwkhjGAPvdWNKcEPCCvBrdhPDmWM_J3edPPzZf2e23Lzeb61vmGyl_s7bvB9O1stejGEFBcCqM0LhONDz03SCGvldK6yEM4I1plJTKCdVpL0fZeteck7eHvducHlbAYueIHqbJLZBWtF2net3Kphr1wehzQsww2m2Os8tPVnC7B22fQds9Rcu1fQZt72vu8nhgHWYI_1JHslW_OuhQv9xFyBZ9hMVDiBl8sSHF_1z4A9F8j_g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77495623</pqid></control><display><type>article</type><title>In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Staalsen, N.H. ; Ulrich, M. ; Kim, W.Y. ; Pedersen, E.M. ; How, T.V. ; Hasenkam, J.M.</creator><creatorcontrib>Staalsen, N.H. ; Ulrich, M. ; Kim, W.Y. ; Pedersen, E.M. ; How, T.V. ; Hasenkam, J.M.</creatorcontrib><description>The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles in vivo. The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyurethane graft. Three anastomosis angles: 90° ( n = 3), 45° ( n = 3) and 15° ( n = 4) were studied. The bypass length, the anatomical position and the geometry of the anastomoses were standardised. During measurements, the proximal outflow segment was occluded and the flow rate was controlled by reversible iliac artery cross-clamping. Using a colour Doppler system the velocity fields were measured at various positions in the anatomosis. The colour Doppler velocity data were transferred to a computer for dynamic three-dimensional visualisation of the velocity profiles. The angulation was reproduced within 10%. During the experiment, the flow rate was kept constant with Reynold's numbers typical for peripheral arteries. In the 90° anastomoses very disturbed flow fields were seen. The 45° anastomoses were characterised by: (1) low antegrade and retrograde velocities at the heel and (2) a zone of reverse and oscillating velocities at the toe and at one diameter downstream of the toe (1DDD) during deceleration. In the 15° anastomoses no flow disturbances were seen either at the toe or at 1DDD. The velocity profiles were close to parabolic at peak flow at both positions. It is concluded that the 15° anastomosis is preferable from a haemodynamic point of view.</description><identifier>ISSN: 1078-5884</identifier><identifier>EISSN: 1532-2165</identifier><identifier>DOI: 10.1016/S1078-5884(05)80108-X</identifier><identifier>PMID: 7655968</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Anastomosis angle ; Anastomosis, Surgical - methods ; Animals ; Aorta, Abdominal - surgery ; Blood Flow Velocity ; Blood velocity ; Blood Vessel Prosthesis ; Colour Doppler ultrasound ; Pigs ; Polyurethanes ; Swine ; Ultrasonography, Doppler, Color ; Vascular anastomosis ; Vascular Surgical Procedures - methods</subject><ispartof>European journal of vascular and endovascular surgery, 1995-08, Vol.10 (2), p.168-181</ispartof><rights>1995 W. B. Saunders Company Ltd. All rights reserved</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c322x-699b876295f1fe4eda4dfe3a7130d97b1b994455bdbec8834224a1475c2f26ca3</citedby><cites>FETCH-LOGICAL-c322x-699b876295f1fe4eda4dfe3a7130d97b1b994455bdbec8834224a1475c2f26ca3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S1078-5884(05)80108-X$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7655968$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Staalsen, N.H.</creatorcontrib><creatorcontrib>Ulrich, M.</creatorcontrib><creatorcontrib>Kim, W.Y.</creatorcontrib><creatorcontrib>Pedersen, E.M.</creatorcontrib><creatorcontrib>How, T.V.</creatorcontrib><creatorcontrib>Hasenkam, J.M.</creatorcontrib><title>In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses</title><title>European journal of vascular and endovascular surgery</title><addtitle>Eur J Vasc Endovasc Surg</addtitle><description>The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles in vivo. The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyurethane graft. Three anastomosis angles: 90° ( n = 3), 45° ( n = 3) and 15° ( n = 4) were studied. The bypass length, the anatomical position and the geometry of the anastomoses were standardised. During measurements, the proximal outflow segment was occluded and the flow rate was controlled by reversible iliac artery cross-clamping. Using a colour Doppler system the velocity fields were measured at various positions in the anatomosis. The colour Doppler velocity data were transferred to a computer for dynamic three-dimensional visualisation of the velocity profiles. The angulation was reproduced within 10%. During the experiment, the flow rate was kept constant with Reynold's numbers typical for peripheral arteries. In the 90° anastomoses very disturbed flow fields were seen. The 45° anastomoses were characterised by: (1) low antegrade and retrograde velocities at the heel and (2) a zone of reverse and oscillating velocities at the toe and at one diameter downstream of the toe (1DDD) during deceleration. In the 15° anastomoses no flow disturbances were seen either at the toe or at 1DDD. The velocity profiles were close to parabolic at peak flow at both positions. It is concluded that the 15° anastomosis is preferable from a haemodynamic point of view.</description><subject>Anastomosis angle</subject><subject>Anastomosis, Surgical - methods</subject><subject>Animals</subject><subject>Aorta, Abdominal - surgery</subject><subject>Blood Flow Velocity</subject><subject>Blood velocity</subject><subject>Blood Vessel Prosthesis</subject><subject>Colour Doppler ultrasound</subject><subject>Pigs</subject><subject>Polyurethanes</subject><subject>Swine</subject><subject>Ultrasonography, Doppler, Color</subject><subject>Vascular anastomosis</subject><subject>Vascular Surgical Procedures - methods</subject><issn>1078-5884</issn><issn>1532-2165</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE9v1DAQxS0EakvLR6jkE4KDwXbsxDlV1Yo_lSpxgEq9WY49EUZJvPU4W_rt8XYXrpxmRu-9Gc2PkEvBPwgu2o_fBe8M08aod1y_N1xww-5fkDOhG8mkaPXL2v-1nJLXiL8451o0-oScdK3WfWvOSLpZ6C7uEnWLm54wYm0CLT8zAAtxhgVjqkr14OqmiK7UmaaRDlNKgY5TeqRbVwrkpUYL3Tn06-QyhSWwkhjGAPvdWNKcEPCCvBrdhPDmWM_J3edPPzZf2e23Lzeb61vmGyl_s7bvB9O1stejGEFBcCqM0LhONDz03SCGvldK6yEM4I1plJTKCdVpL0fZeteck7eHvducHlbAYueIHqbJLZBWtF2net3Kphr1wehzQsww2m2Os8tPVnC7B22fQds9Rcu1fQZt72vu8nhgHWYI_1JHslW_OuhQv9xFyBZ9hMVDiBl8sSHF_1z4A9F8j_g</recordid><startdate>199508</startdate><enddate>199508</enddate><creator>Staalsen, N.H.</creator><creator>Ulrich, M.</creator><creator>Kim, W.Y.</creator><creator>Pedersen, E.M.</creator><creator>How, T.V.</creator><creator>Hasenkam, J.M.</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199508</creationdate><title>In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses</title><author>Staalsen, N.H. ; Ulrich, M. ; Kim, W.Y. ; Pedersen, E.M. ; How, T.V. ; Hasenkam, J.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c322x-699b876295f1fe4eda4dfe3a7130d97b1b994455bdbec8834224a1475c2f26ca3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Anastomosis angle</topic><topic>Anastomosis, Surgical - methods</topic><topic>Animals</topic><topic>Aorta, Abdominal - surgery</topic><topic>Blood Flow Velocity</topic><topic>Blood velocity</topic><topic>Blood Vessel Prosthesis</topic><topic>Colour Doppler ultrasound</topic><topic>Pigs</topic><topic>Polyurethanes</topic><topic>Swine</topic><topic>Ultrasonography, Doppler, Color</topic><topic>Vascular anastomosis</topic><topic>Vascular Surgical Procedures - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Staalsen, N.H.</creatorcontrib><creatorcontrib>Ulrich, M.</creatorcontrib><creatorcontrib>Kim, W.Y.</creatorcontrib><creatorcontrib>Pedersen, E.M.</creatorcontrib><creatorcontrib>How, T.V.</creatorcontrib><creatorcontrib>Hasenkam, J.M.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of vascular and endovascular surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Staalsen, N.H.</au><au>Ulrich, M.</au><au>Kim, W.Y.</au><au>Pedersen, E.M.</au><au>How, T.V.</au><au>Hasenkam, J.M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses</atitle><jtitle>European journal of vascular and endovascular surgery</jtitle><addtitle>Eur J Vasc Endovasc Surg</addtitle><date>1995-08</date><risdate>1995</risdate><volume>10</volume><issue>2</issue><spage>168</spage><epage>181</epage><pages>168-181</pages><issn>1078-5884</issn><eissn>1532-2165</eissn><abstract>The aim of this study was to describe the velocity fields at distal vascular end-to-side anastomoses with different anastomosis angles in vivo. The abdominal aorta of ten 90 kg pigs was exposed from the superior mesenteric artery to the trifurcation. A segment of the aorta was bypassed using a polyurethane graft. Three anastomosis angles: 90° ( n = 3), 45° ( n = 3) and 15° ( n = 4) were studied. The bypass length, the anatomical position and the geometry of the anastomoses were standardised. During measurements, the proximal outflow segment was occluded and the flow rate was controlled by reversible iliac artery cross-clamping. Using a colour Doppler system the velocity fields were measured at various positions in the anatomosis. The colour Doppler velocity data were transferred to a computer for dynamic three-dimensional visualisation of the velocity profiles. The angulation was reproduced within 10%. During the experiment, the flow rate was kept constant with Reynold's numbers typical for peripheral arteries. In the 90° anastomoses very disturbed flow fields were seen. The 45° anastomoses were characterised by: (1) low antegrade and retrograde velocities at the heel and (2) a zone of reverse and oscillating velocities at the toe and at one diameter downstream of the toe (1DDD) during deceleration. In the 15° anastomoses no flow disturbances were seen either at the toe or at 1DDD. The velocity profiles were close to parabolic at peak flow at both positions. It is concluded that the 15° anastomosis is preferable from a haemodynamic point of view.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>7655968</pmid><doi>10.1016/S1078-5884(05)80108-X</doi><tpages>14</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1078-5884
ispartof European journal of vascular and endovascular surgery, 1995-08, Vol.10 (2), p.168-181
issn 1078-5884
1532-2165
language eng
recordid cdi_proquest_miscellaneous_77495623
source MEDLINE; ScienceDirect Journals (5 years ago - present); EZB-FREE-00999 freely available EZB journals
subjects Anastomosis angle
Anastomosis, Surgical - methods
Animals
Aorta, Abdominal - surgery
Blood Flow Velocity
Blood velocity
Blood Vessel Prosthesis
Colour Doppler ultrasound
Pigs
Polyurethanes
Swine
Ultrasonography, Doppler, Color
Vascular anastomosis
Vascular Surgical Procedures - methods
title In vivo analysis and three-dimensional visualisation of blood flow patterns at vascular end-to-side anastomoses
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T01%3A15%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20vivo%20analysis%20and%20three-dimensional%20visualisation%20of%20blood%20flow%20patterns%20at%20vascular%20end-to-side%20anastomoses&rft.jtitle=European%20journal%20of%20vascular%20and%20endovascular%20surgery&rft.au=Staalsen,%20N.H.&rft.date=1995-08&rft.volume=10&rft.issue=2&rft.spage=168&rft.epage=181&rft.pages=168-181&rft.issn=1078-5884&rft.eissn=1532-2165&rft_id=info:doi/10.1016/S1078-5884(05)80108-X&rft_dat=%3Cproquest_cross%3E77495623%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77495623&rft_id=info:pmid/7655968&rft_els_id=S107858840580108X&rfr_iscdi=true