Short-term results of hydroxyapatite-coated primary total hip arthroplasty

One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné sco...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical orthopaedics and related research 1995, Vol.310 (310), p.98-102
Hauptverfasser: ROSSI, P, SIBELLI, P, FUMERO, S, CRUA, E
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 102
container_issue 310
container_start_page 98
container_title Clinical orthopaedics and related research
container_volume 310
creator ROSSI, P
SIBELLI, P
FUMERO, S
CRUA, E
description One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné score showed that 96 patients had an excellent score at a minimum of 2 years from the operation. Radiographic analysis, based on DeLee and Charnley criteria for the acetabular cup and on Gruen criteria for the femoral stem, showed equally good results. There was good initial stability of the cup and the metaphyseal portion of the stem, with a secondary increase of load transmission in Zones 2 and 6 with cortical and cancellous thickening.
doi_str_mv 10.1097/00003086-199501000-00017
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77458550</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>16832229</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-24ad9271e0028345c8abd054e10854de63fc550e6053d92575989d049f0deb183</originalsourceid><addsrcrecordid>eNqFkMtKxDAUhoMo4zj6CEIX4i6a-2Up4pUBFyq4K5k0pZXOpCYp2Lc349TZGgghOd9_knwAFBhdYaTlNcqDIiUg1pojnHcwTywPwBxzoiDGlByCeT7TUBP8cQxOYvzchhgnMzCTgmEmxBw8vzY-JJhcWBfBxaFLsfB10YxV8N-j6U1qk4PWm-Sqog_t2oSxSD6ZrmjavjAhNcH3nYlpPAVHtemiO5vWBXi_v3u7fYTLl4en25sltFSiBAkzlSYSO4SIys-xyqwqxJnDSHFWOUFryzlyAnGaQS65VrpCTNeocius6AJc7vr2wX8NLqZy3Ubrus5snB9iKSXjKnf4F8RCUUKIzqDagTb4GIOry-mnJUbl1nf557vc-y5_fefo-XTHsFq7ah-cBOf6xVQ30ZquDmZj27jHKCMaCUl_ANL8h2s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>16832229</pqid></control><display><type>article</type><title>Short-term results of hydroxyapatite-coated primary total hip arthroplasty</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>ROSSI, P ; SIBELLI, P ; FUMERO, S ; CRUA, E</creator><creatorcontrib>ROSSI, P ; SIBELLI, P ; FUMERO, S ; CRUA, E</creatorcontrib><description>One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné score showed that 96 patients had an excellent score at a minimum of 2 years from the operation. Radiographic analysis, based on DeLee and Charnley criteria for the acetabular cup and on Gruen criteria for the femoral stem, showed equally good results. There was good initial stability of the cup and the metaphyseal portion of the stem, with a secondary increase of load transmission in Zones 2 and 6 with cortical and cancellous thickening.</description><identifier>ISSN: 0009-921X</identifier><identifier>EISSN: 1528-1132</identifier><identifier>DOI: 10.1097/00003086-199501000-00017</identifier><identifier>PMID: 7641466</identifier><identifier>CODEN: CORTBR</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Adult ; Aged ; Biological and medical sciences ; Bone Remodeling ; Durapatite ; Female ; Hip Prosthesis - adverse effects ; Hip Prosthesis - methods ; Humans ; Male ; Medical sciences ; Middle Aged ; Orthopedic surgery ; Prospective Studies ; Prosthesis Design ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Treatment Outcome</subject><ispartof>Clinical orthopaedics and related research, 1995, Vol.310 (310), p.98-102</ispartof><rights>1995 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-24ad9271e0028345c8abd054e10854de63fc550e6053d92575989d049f0deb183</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4010,27902,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3429067$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7641466$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ROSSI, P</creatorcontrib><creatorcontrib>SIBELLI, P</creatorcontrib><creatorcontrib>FUMERO, S</creatorcontrib><creatorcontrib>CRUA, E</creatorcontrib><title>Short-term results of hydroxyapatite-coated primary total hip arthroplasty</title><title>Clinical orthopaedics and related research</title><addtitle>Clin Orthop Relat Res</addtitle><description>One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné score showed that 96 patients had an excellent score at a minimum of 2 years from the operation. Radiographic analysis, based on DeLee and Charnley criteria for the acetabular cup and on Gruen criteria for the femoral stem, showed equally good results. There was good initial stability of the cup and the metaphyseal portion of the stem, with a secondary increase of load transmission in Zones 2 and 6 with cortical and cancellous thickening.</description><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Bone Remodeling</subject><subject>Durapatite</subject><subject>Female</subject><subject>Hip Prosthesis - adverse effects</subject><subject>Hip Prosthesis - methods</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Orthopedic surgery</subject><subject>Prospective Studies</subject><subject>Prosthesis Design</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Treatment Outcome</subject><issn>0009-921X</issn><issn>1528-1132</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkMtKxDAUhoMo4zj6CEIX4i6a-2Up4pUBFyq4K5k0pZXOpCYp2Lc349TZGgghOd9_knwAFBhdYaTlNcqDIiUg1pojnHcwTywPwBxzoiDGlByCeT7TUBP8cQxOYvzchhgnMzCTgmEmxBw8vzY-JJhcWBfBxaFLsfB10YxV8N-j6U1qk4PWm-Sqog_t2oSxSD6ZrmjavjAhNcH3nYlpPAVHtemiO5vWBXi_v3u7fYTLl4en25sltFSiBAkzlSYSO4SIys-xyqwqxJnDSHFWOUFryzlyAnGaQS65VrpCTNeocius6AJc7vr2wX8NLqZy3Ubrus5snB9iKSXjKnf4F8RCUUKIzqDagTb4GIOry-mnJUbl1nf557vc-y5_fefo-XTHsFq7ah-cBOf6xVQ30ZquDmZj27jHKCMaCUl_ANL8h2s</recordid><startdate>1995</startdate><enddate>1995</enddate><creator>ROSSI, P</creator><creator>SIBELLI, P</creator><creator>FUMERO, S</creator><creator>CRUA, E</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QP</scope><scope>7X8</scope></search><sort><creationdate>1995</creationdate><title>Short-term results of hydroxyapatite-coated primary total hip arthroplasty</title><author>ROSSI, P ; SIBELLI, P ; FUMERO, S ; CRUA, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-24ad9271e0028345c8abd054e10854de63fc550e6053d92575989d049f0deb183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Bone Remodeling</topic><topic>Durapatite</topic><topic>Female</topic><topic>Hip Prosthesis - adverse effects</topic><topic>Hip Prosthesis - methods</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Orthopedic surgery</topic><topic>Prospective Studies</topic><topic>Prosthesis Design</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ROSSI, P</creatorcontrib><creatorcontrib>SIBELLI, P</creatorcontrib><creatorcontrib>FUMERO, S</creatorcontrib><creatorcontrib>CRUA, E</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Calcium &amp; Calcified Tissue Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical orthopaedics and related research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ROSSI, P</au><au>SIBELLI, P</au><au>FUMERO, S</au><au>CRUA, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Short-term results of hydroxyapatite-coated primary total hip arthroplasty</atitle><jtitle>Clinical orthopaedics and related research</jtitle><addtitle>Clin Orthop Relat Res</addtitle><date>1995</date><risdate>1995</risdate><volume>310</volume><issue>310</issue><spage>98</spage><epage>102</epage><pages>98-102</pages><issn>0009-921X</issn><eissn>1528-1132</eissn><coden>CORTBR</coden><abstract>One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné score showed that 96 patients had an excellent score at a minimum of 2 years from the operation. Radiographic analysis, based on DeLee and Charnley criteria for the acetabular cup and on Gruen criteria for the femoral stem, showed equally good results. There was good initial stability of the cup and the metaphyseal portion of the stem, with a secondary increase of load transmission in Zones 2 and 6 with cortical and cancellous thickening.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>7641466</pmid><doi>10.1097/00003086-199501000-00017</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0009-921X
ispartof Clinical orthopaedics and related research, 1995, Vol.310 (310), p.98-102
issn 0009-921X
1528-1132
language eng
recordid cdi_proquest_miscellaneous_77458550
source MEDLINE; Journals@Ovid Complete
subjects Adult
Aged
Biological and medical sciences
Bone Remodeling
Durapatite
Female
Hip Prosthesis - adverse effects
Hip Prosthesis - methods
Humans
Male
Medical sciences
Middle Aged
Orthopedic surgery
Prospective Studies
Prosthesis Design
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Treatment Outcome
title Short-term results of hydroxyapatite-coated primary total hip arthroplasty
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T13%3A15%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Short-term%20results%20of%20hydroxyapatite-coated%20primary%20total%20hip%20arthroplasty&rft.jtitle=Clinical%20orthopaedics%20and%20related%20research&rft.au=ROSSI,%20P&rft.date=1995&rft.volume=310&rft.issue=310&rft.spage=98&rft.epage=102&rft.pages=98-102&rft.issn=0009-921X&rft.eissn=1528-1132&rft.coden=CORTBR&rft_id=info:doi/10.1097/00003086-199501000-00017&rft_dat=%3Cproquest_cross%3E16832229%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=16832229&rft_id=info:pmid/7641466&rfr_iscdi=true