Short-term results of hydroxyapatite-coated primary total hip arthroplasty
One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné sco...
Gespeichert in:
Veröffentlicht in: | Clinical orthopaedics and related research 1995, Vol.310 (310), p.98-102 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 102 |
---|---|
container_issue | 310 |
container_start_page | 98 |
container_title | Clinical orthopaedics and related research |
container_volume | 310 |
creator | ROSSI, P SIBELLI, P FUMERO, S CRUA, E |
description | One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné score showed that 96 patients had an excellent score at a minimum of 2 years from the operation. Radiographic analysis, based on DeLee and Charnley criteria for the acetabular cup and on Gruen criteria for the femoral stem, showed equally good results. There was good initial stability of the cup and the metaphyseal portion of the stem, with a secondary increase of load transmission in Zones 2 and 6 with cortical and cancellous thickening. |
doi_str_mv | 10.1097/00003086-199501000-00017 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77458550</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>16832229</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-24ad9271e0028345c8abd054e10854de63fc550e6053d92575989d049f0deb183</originalsourceid><addsrcrecordid>eNqFkMtKxDAUhoMo4zj6CEIX4i6a-2Up4pUBFyq4K5k0pZXOpCYp2Lc349TZGgghOd9_knwAFBhdYaTlNcqDIiUg1pojnHcwTywPwBxzoiDGlByCeT7TUBP8cQxOYvzchhgnMzCTgmEmxBw8vzY-JJhcWBfBxaFLsfB10YxV8N-j6U1qk4PWm-Sqog_t2oSxSD6ZrmjavjAhNcH3nYlpPAVHtemiO5vWBXi_v3u7fYTLl4en25sltFSiBAkzlSYSO4SIys-xyqwqxJnDSHFWOUFryzlyAnGaQS65VrpCTNeocius6AJc7vr2wX8NLqZy3Ubrus5snB9iKSXjKnf4F8RCUUKIzqDagTb4GIOry-mnJUbl1nf557vc-y5_fefo-XTHsFq7ah-cBOf6xVQ30ZquDmZj27jHKCMaCUl_ANL8h2s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>16832229</pqid></control><display><type>article</type><title>Short-term results of hydroxyapatite-coated primary total hip arthroplasty</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>ROSSI, P ; SIBELLI, P ; FUMERO, S ; CRUA, E</creator><creatorcontrib>ROSSI, P ; SIBELLI, P ; FUMERO, S ; CRUA, E</creatorcontrib><description>One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné score showed that 96 patients had an excellent score at a minimum of 2 years from the operation. Radiographic analysis, based on DeLee and Charnley criteria for the acetabular cup and on Gruen criteria for the femoral stem, showed equally good results. There was good initial stability of the cup and the metaphyseal portion of the stem, with a secondary increase of load transmission in Zones 2 and 6 with cortical and cancellous thickening.</description><identifier>ISSN: 0009-921X</identifier><identifier>EISSN: 1528-1132</identifier><identifier>DOI: 10.1097/00003086-199501000-00017</identifier><identifier>PMID: 7641466</identifier><identifier>CODEN: CORTBR</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Adult ; Aged ; Biological and medical sciences ; Bone Remodeling ; Durapatite ; Female ; Hip Prosthesis - adverse effects ; Hip Prosthesis - methods ; Humans ; Male ; Medical sciences ; Middle Aged ; Orthopedic surgery ; Prospective Studies ; Prosthesis Design ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Treatment Outcome</subject><ispartof>Clinical orthopaedics and related research, 1995, Vol.310 (310), p.98-102</ispartof><rights>1995 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-24ad9271e0028345c8abd054e10854de63fc550e6053d92575989d049f0deb183</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4010,27902,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=3429067$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7641466$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ROSSI, P</creatorcontrib><creatorcontrib>SIBELLI, P</creatorcontrib><creatorcontrib>FUMERO, S</creatorcontrib><creatorcontrib>CRUA, E</creatorcontrib><title>Short-term results of hydroxyapatite-coated primary total hip arthroplasty</title><title>Clinical orthopaedics and related research</title><addtitle>Clin Orthop Relat Res</addtitle><description>One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné score showed that 96 patients had an excellent score at a minimum of 2 years from the operation. Radiographic analysis, based on DeLee and Charnley criteria for the acetabular cup and on Gruen criteria for the femoral stem, showed equally good results. There was good initial stability of the cup and the metaphyseal portion of the stem, with a secondary increase of load transmission in Zones 2 and 6 with cortical and cancellous thickening.</description><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Bone Remodeling</subject><subject>Durapatite</subject><subject>Female</subject><subject>Hip Prosthesis - adverse effects</subject><subject>Hip Prosthesis - methods</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Orthopedic surgery</subject><subject>Prospective Studies</subject><subject>Prosthesis Design</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Treatment Outcome</subject><issn>0009-921X</issn><issn>1528-1132</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkMtKxDAUhoMo4zj6CEIX4i6a-2Up4pUBFyq4K5k0pZXOpCYp2Lc349TZGgghOd9_knwAFBhdYaTlNcqDIiUg1pojnHcwTywPwBxzoiDGlByCeT7TUBP8cQxOYvzchhgnMzCTgmEmxBw8vzY-JJhcWBfBxaFLsfB10YxV8N-j6U1qk4PWm-Sqog_t2oSxSD6ZrmjavjAhNcH3nYlpPAVHtemiO5vWBXi_v3u7fYTLl4en25sltFSiBAkzlSYSO4SIys-xyqwqxJnDSHFWOUFryzlyAnGaQS65VrpCTNeocius6AJc7vr2wX8NLqZy3Ubrus5snB9iKSXjKnf4F8RCUUKIzqDagTb4GIOry-mnJUbl1nf557vc-y5_fefo-XTHsFq7ah-cBOf6xVQ30ZquDmZj27jHKCMaCUl_ANL8h2s</recordid><startdate>1995</startdate><enddate>1995</enddate><creator>ROSSI, P</creator><creator>SIBELLI, P</creator><creator>FUMERO, S</creator><creator>CRUA, E</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QP</scope><scope>7X8</scope></search><sort><creationdate>1995</creationdate><title>Short-term results of hydroxyapatite-coated primary total hip arthroplasty</title><author>ROSSI, P ; SIBELLI, P ; FUMERO, S ; CRUA, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-24ad9271e0028345c8abd054e10854de63fc550e6053d92575989d049f0deb183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Bone Remodeling</topic><topic>Durapatite</topic><topic>Female</topic><topic>Hip Prosthesis - adverse effects</topic><topic>Hip Prosthesis - methods</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Orthopedic surgery</topic><topic>Prospective Studies</topic><topic>Prosthesis Design</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ROSSI, P</creatorcontrib><creatorcontrib>SIBELLI, P</creatorcontrib><creatorcontrib>FUMERO, S</creatorcontrib><creatorcontrib>CRUA, E</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical orthopaedics and related research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ROSSI, P</au><au>SIBELLI, P</au><au>FUMERO, S</au><au>CRUA, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Short-term results of hydroxyapatite-coated primary total hip arthroplasty</atitle><jtitle>Clinical orthopaedics and related research</jtitle><addtitle>Clin Orthop Relat Res</addtitle><date>1995</date><risdate>1995</risdate><volume>310</volume><issue>310</issue><spage>98</spage><epage>102</epage><pages>98-102</pages><issn>0009-921X</issn><eissn>1528-1132</eissn><coden>CORTBR</coden><abstract>One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné score showed that 96 patients had an excellent score at a minimum of 2 years from the operation. Radiographic analysis, based on DeLee and Charnley criteria for the acetabular cup and on Gruen criteria for the femoral stem, showed equally good results. There was good initial stability of the cup and the metaphyseal portion of the stem, with a secondary increase of load transmission in Zones 2 and 6 with cortical and cancellous thickening.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>7641466</pmid><doi>10.1097/00003086-199501000-00017</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0009-921X |
ispartof | Clinical orthopaedics and related research, 1995, Vol.310 (310), p.98-102 |
issn | 0009-921X 1528-1132 |
language | eng |
recordid | cdi_proquest_miscellaneous_77458550 |
source | MEDLINE; Journals@Ovid Complete |
subjects | Adult Aged Biological and medical sciences Bone Remodeling Durapatite Female Hip Prosthesis - adverse effects Hip Prosthesis - methods Humans Male Medical sciences Middle Aged Orthopedic surgery Prospective Studies Prosthesis Design Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Treatment Outcome |
title | Short-term results of hydroxyapatite-coated primary total hip arthroplasty |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T13%3A15%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Short-term%20results%20of%20hydroxyapatite-coated%20primary%20total%20hip%20arthroplasty&rft.jtitle=Clinical%20orthopaedics%20and%20related%20research&rft.au=ROSSI,%20P&rft.date=1995&rft.volume=310&rft.issue=310&rft.spage=98&rft.epage=102&rft.pages=98-102&rft.issn=0009-921X&rft.eissn=1528-1132&rft.coden=CORTBR&rft_id=info:doi/10.1097/00003086-199501000-00017&rft_dat=%3Cproquest_cross%3E16832229%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=16832229&rft_id=info:pmid/7641466&rfr_iscdi=true |