Correlation of histological tumor vascularization and Doppler sonography in patients with malignant melanoma of the choroid

In previous studies Doppler sonography was proven to the useful for diagnostics and follow-up of malignant melanomas of the choroid. To evaluate the correlation between Doppler sonographical findings and the histological tumor vascularization, we examined five eyes of five patients with malignant me...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Graefe's archive for clinical and experimental ophthalmology 1995-05, Vol.233 (5), p.257-260
Hauptverfasser: Damms, T, Schäfer, H, Guthoff, R, Winkler, P, Winter, R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 260
container_issue 5
container_start_page 257
container_title Graefe's archive for clinical and experimental ophthalmology
container_volume 233
creator Damms, T
Schäfer, H
Guthoff, R
Winkler, P
Winter, R
description In previous studies Doppler sonography was proven to the useful for diagnostics and follow-up of malignant melanomas of the choroid. To evaluate the correlation between Doppler sonographical findings and the histological tumor vascularization, we examined five eyes of five patients with malignant melanoma of the choroid before enucleation with an ATL Ultramark-8 Duplex scanner and compared these results with computerized planimetry of histological tumor vascularization after immunohistochemical staining of vascular endothelium with anti-factor-VIII antibodies. We found no definite correlation of flow velocities with histological parameters of tumor vascularization. The tendency was for a decrease in maximum flow velocities as histological vascularization increased. Due to (1) the usual lack of sensitivity parameters of the used Duplex device for the clinical user and (2) the unpredictable branching pattern within a melanoma resulting in an unknown angle of incidence of the Doppler beam, we conclude that the quantitative results of Doppler sonography require cautious interpretation. Nevertheless, presence or absence of Doppler shifts is a valuable parameter for the follow-up of irradiated tumors.
doi_str_mv 10.1007/BF00177646
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77412683</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77412683</sourcerecordid><originalsourceid>FETCH-LOGICAL-c282t-b243b6ba9ced5c5f4f92d5f13276fa03c29077f7ad92377a324a5f5aca8c56113</originalsourceid><addsrcrecordid>eNpFkM9LwzAYhoMoc04v3oWcPAjV_Gib9qjTqTDworBb-Zoma6RtapIq03_ejg09fYf34X0_HoTOKbmmhIibuwUhVIg0Tg_QlMY8iQRhq0M0JYLRKONsdYxOvH8nhIwhnaCJSGKW0myKfubWOdVAMLbDVuPa-GAbuzYSGhyG1jr8CV4ODTjzvaOgq_C97ftGOextZ9cO-nqDTYf7EVBd8PjLhBq30Jh1B13A7TjQ2Ra2A6FWWNbWWVOdoiMNjVdn-ztDb4uH1_lTtHx5fJ7fLiPJMhaiksW8TEvIpaoSmehY56xKNOVMpBoIlywnQmgBVc64EMBZDIlOQEImk5RSPkOXu97e2Y9B-VC0xkvVjE8pO_hCiJiyNOMjeLUDpbPeO6WL3pkW3KagpNiaLv5Nj_DFvnUoW1X9oXu1_BfwDXub</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77412683</pqid></control><display><type>article</type><title>Correlation of histological tumor vascularization and Doppler sonography in patients with malignant melanoma of the choroid</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Damms, T ; Schäfer, H ; Guthoff, R ; Winkler, P ; Winter, R</creator><creatorcontrib>Damms, T ; Schäfer, H ; Guthoff, R ; Winkler, P ; Winter, R</creatorcontrib><description>In previous studies Doppler sonography was proven to the useful for diagnostics and follow-up of malignant melanomas of the choroid. To evaluate the correlation between Doppler sonographical findings and the histological tumor vascularization, we examined five eyes of five patients with malignant melanoma of the choroid before enucleation with an ATL Ultramark-8 Duplex scanner and compared these results with computerized planimetry of histological tumor vascularization after immunohistochemical staining of vascular endothelium with anti-factor-VIII antibodies. We found no definite correlation of flow velocities with histological parameters of tumor vascularization. The tendency was for a decrease in maximum flow velocities as histological vascularization increased. Due to (1) the usual lack of sensitivity parameters of the used Duplex device for the clinical user and (2) the unpredictable branching pattern within a melanoma resulting in an unknown angle of incidence of the Doppler beam, we conclude that the quantitative results of Doppler sonography require cautious interpretation. Nevertheless, presence or absence of Doppler shifts is a valuable parameter for the follow-up of irradiated tumors.</description><identifier>ISSN: 0721-832X</identifier><identifier>EISSN: 1435-702X</identifier><identifier>DOI: 10.1007/BF00177646</identifier><identifier>PMID: 7542618</identifier><language>eng</language><publisher>Germany</publisher><subject>Blood Flow Velocity ; Choroid Neoplasms - blood supply ; Choroid Neoplasms - diagnostic imaging ; Choroid Neoplasms - pathology ; Endothelium, Vascular - chemistry ; Eye Enucleation ; Factor VIII - analysis ; Humans ; Immunoenzyme Techniques ; Melanoma - blood supply ; Melanoma - diagnostic imaging ; Melanoma - pathology ; Neovascularization, Pathologic - diagnostic imaging ; Neovascularization, Pathologic - pathology ; Ultrasonography, Doppler, Duplex</subject><ispartof>Graefe's archive for clinical and experimental ophthalmology, 1995-05, Vol.233 (5), p.257-260</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c282t-b243b6ba9ced5c5f4f92d5f13276fa03c29077f7ad92377a324a5f5aca8c56113</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7542618$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Damms, T</creatorcontrib><creatorcontrib>Schäfer, H</creatorcontrib><creatorcontrib>Guthoff, R</creatorcontrib><creatorcontrib>Winkler, P</creatorcontrib><creatorcontrib>Winter, R</creatorcontrib><title>Correlation of histological tumor vascularization and Doppler sonography in patients with malignant melanoma of the choroid</title><title>Graefe's archive for clinical and experimental ophthalmology</title><addtitle>Graefes Arch Clin Exp Ophthalmol</addtitle><description>In previous studies Doppler sonography was proven to the useful for diagnostics and follow-up of malignant melanomas of the choroid. To evaluate the correlation between Doppler sonographical findings and the histological tumor vascularization, we examined five eyes of five patients with malignant melanoma of the choroid before enucleation with an ATL Ultramark-8 Duplex scanner and compared these results with computerized planimetry of histological tumor vascularization after immunohistochemical staining of vascular endothelium with anti-factor-VIII antibodies. We found no definite correlation of flow velocities with histological parameters of tumor vascularization. The tendency was for a decrease in maximum flow velocities as histological vascularization increased. Due to (1) the usual lack of sensitivity parameters of the used Duplex device for the clinical user and (2) the unpredictable branching pattern within a melanoma resulting in an unknown angle of incidence of the Doppler beam, we conclude that the quantitative results of Doppler sonography require cautious interpretation. Nevertheless, presence or absence of Doppler shifts is a valuable parameter for the follow-up of irradiated tumors.</description><subject>Blood Flow Velocity</subject><subject>Choroid Neoplasms - blood supply</subject><subject>Choroid Neoplasms - diagnostic imaging</subject><subject>Choroid Neoplasms - pathology</subject><subject>Endothelium, Vascular - chemistry</subject><subject>Eye Enucleation</subject><subject>Factor VIII - analysis</subject><subject>Humans</subject><subject>Immunoenzyme Techniques</subject><subject>Melanoma - blood supply</subject><subject>Melanoma - diagnostic imaging</subject><subject>Melanoma - pathology</subject><subject>Neovascularization, Pathologic - diagnostic imaging</subject><subject>Neovascularization, Pathologic - pathology</subject><subject>Ultrasonography, Doppler, Duplex</subject><issn>0721-832X</issn><issn>1435-702X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkM9LwzAYhoMoc04v3oWcPAjV_Gib9qjTqTDworBb-Zoma6RtapIq03_ejg09fYf34X0_HoTOKbmmhIibuwUhVIg0Tg_QlMY8iQRhq0M0JYLRKONsdYxOvH8nhIwhnaCJSGKW0myKfubWOdVAMLbDVuPa-GAbuzYSGhyG1jr8CV4ODTjzvaOgq_C97ftGOextZ9cO-nqDTYf7EVBd8PjLhBq30Jh1B13A7TjQ2Ra2A6FWWNbWWVOdoiMNjVdn-ztDb4uH1_lTtHx5fJ7fLiPJMhaiksW8TEvIpaoSmehY56xKNOVMpBoIlywnQmgBVc64EMBZDIlOQEImk5RSPkOXu97e2Y9B-VC0xkvVjE8pO_hCiJiyNOMjeLUDpbPeO6WL3pkW3KagpNiaLv5Nj_DFvnUoW1X9oXu1_BfwDXub</recordid><startdate>19950501</startdate><enddate>19950501</enddate><creator>Damms, T</creator><creator>Schäfer, H</creator><creator>Guthoff, R</creator><creator>Winkler, P</creator><creator>Winter, R</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19950501</creationdate><title>Correlation of histological tumor vascularization and Doppler sonography in patients with malignant melanoma of the choroid</title><author>Damms, T ; Schäfer, H ; Guthoff, R ; Winkler, P ; Winter, R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c282t-b243b6ba9ced5c5f4f92d5f13276fa03c29077f7ad92377a324a5f5aca8c56113</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Blood Flow Velocity</topic><topic>Choroid Neoplasms - blood supply</topic><topic>Choroid Neoplasms - diagnostic imaging</topic><topic>Choroid Neoplasms - pathology</topic><topic>Endothelium, Vascular - chemistry</topic><topic>Eye Enucleation</topic><topic>Factor VIII - analysis</topic><topic>Humans</topic><topic>Immunoenzyme Techniques</topic><topic>Melanoma - blood supply</topic><topic>Melanoma - diagnostic imaging</topic><topic>Melanoma - pathology</topic><topic>Neovascularization, Pathologic - diagnostic imaging</topic><topic>Neovascularization, Pathologic - pathology</topic><topic>Ultrasonography, Doppler, Duplex</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Damms, T</creatorcontrib><creatorcontrib>Schäfer, H</creatorcontrib><creatorcontrib>Guthoff, R</creatorcontrib><creatorcontrib>Winkler, P</creatorcontrib><creatorcontrib>Winter, R</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Graefe's archive for clinical and experimental ophthalmology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Damms, T</au><au>Schäfer, H</au><au>Guthoff, R</au><au>Winkler, P</au><au>Winter, R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Correlation of histological tumor vascularization and Doppler sonography in patients with malignant melanoma of the choroid</atitle><jtitle>Graefe's archive for clinical and experimental ophthalmology</jtitle><addtitle>Graefes Arch Clin Exp Ophthalmol</addtitle><date>1995-05-01</date><risdate>1995</risdate><volume>233</volume><issue>5</issue><spage>257</spage><epage>260</epage><pages>257-260</pages><issn>0721-832X</issn><eissn>1435-702X</eissn><abstract>In previous studies Doppler sonography was proven to the useful for diagnostics and follow-up of malignant melanomas of the choroid. To evaluate the correlation between Doppler sonographical findings and the histological tumor vascularization, we examined five eyes of five patients with malignant melanoma of the choroid before enucleation with an ATL Ultramark-8 Duplex scanner and compared these results with computerized planimetry of histological tumor vascularization after immunohistochemical staining of vascular endothelium with anti-factor-VIII antibodies. We found no definite correlation of flow velocities with histological parameters of tumor vascularization. The tendency was for a decrease in maximum flow velocities as histological vascularization increased. Due to (1) the usual lack of sensitivity parameters of the used Duplex device for the clinical user and (2) the unpredictable branching pattern within a melanoma resulting in an unknown angle of incidence of the Doppler beam, we conclude that the quantitative results of Doppler sonography require cautious interpretation. Nevertheless, presence or absence of Doppler shifts is a valuable parameter for the follow-up of irradiated tumors.</abstract><cop>Germany</cop><pmid>7542618</pmid><doi>10.1007/BF00177646</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0721-832X
ispartof Graefe's archive for clinical and experimental ophthalmology, 1995-05, Vol.233 (5), p.257-260
issn 0721-832X
1435-702X
language eng
recordid cdi_proquest_miscellaneous_77412683
source MEDLINE; SpringerLink Journals - AutoHoldings
subjects Blood Flow Velocity
Choroid Neoplasms - blood supply
Choroid Neoplasms - diagnostic imaging
Choroid Neoplasms - pathology
Endothelium, Vascular - chemistry
Eye Enucleation
Factor VIII - analysis
Humans
Immunoenzyme Techniques
Melanoma - blood supply
Melanoma - diagnostic imaging
Melanoma - pathology
Neovascularization, Pathologic - diagnostic imaging
Neovascularization, Pathologic - pathology
Ultrasonography, Doppler, Duplex
title Correlation of histological tumor vascularization and Doppler sonography in patients with malignant melanoma of the choroid
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T19%3A44%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Correlation%20of%20histological%20tumor%20vascularization%20and%20Doppler%20sonography%20in%20patients%20with%20malignant%20melanoma%20of%20the%20choroid&rft.jtitle=Graefe's%20archive%20for%20clinical%20and%20experimental%20ophthalmology&rft.au=Damms,%20T&rft.date=1995-05-01&rft.volume=233&rft.issue=5&rft.spage=257&rft.epage=260&rft.pages=257-260&rft.issn=0721-832X&rft.eissn=1435-702X&rft_id=info:doi/10.1007/BF00177646&rft_dat=%3Cproquest_cross%3E77412683%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77412683&rft_id=info:pmid/7542618&rfr_iscdi=true