Identification of vascular sphincters at the junction between alveolar capillaries and pulmonary venules of the mouse lung
Background: A peculiar feature of lung circulation in the lung is the pronounced variations in blood volume observed in alveolar capillaries that occur because of the changes in the conformation of the alveolar wall that are associated with the respiratory movements. This phenomenon has led to the p...
Gespeichert in:
Veröffentlicht in: | The Anatomical record 1995-03, Vol.241 (3), p.383-390 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 390 |
---|---|
container_issue | 3 |
container_start_page | 383 |
container_title | The Anatomical record |
container_volume | 241 |
creator | Peáto, Mário N. D. Águas, Artur P. De SÁ, Carlos M. Grande, Nuno Rodrigues |
description | Background: A peculiar feature of lung circulation in the lung is the pronounced variations in blood volume observed in alveolar capillaries that occur because of the changes in the conformation of the alveolar wall that are associated with the respiratory movements. This phenomenon has led to the postulate that mechanisms of postcapillary control of blood flow are to be present in the lung vessels. In the present study we searched for microanatomical evidence of vascular sphincters in the deep lung tissue of mice, namely in alveolar capillaries and pulmonary veins.
Methods: We have used scanning electron microscopy (SEM) to examine two types of samples of normal lung tissue of CD‐1 mice: 1) vascular corrosion casts made by vascular perfusion with Mercox® resin, and 2) routinely made gold/platinum‐coated replicas of sectioned lung tissue.
Results: Careful scrutiny of the vessels of the deep lung tissue led to the identification of sphincters in alveolar capillaries. These sphincters were located at the junction between capillary and pulmonary veins. They corresponded to areas to the vascular wall showing circular swellings where a radial organization was observed, since they were made up of alternating grooves and bulges. Transmission electron microscopy showed that smooth muscle cells participated in the formation of the sphincters.
Conclusions: Our data reveal a new location for vascular sphincters in pulmonary vessels and, because these novel sphincters are located at the capillary‐vein junction, they offer a structural setting for the existence of postcapillary control of blood flow in the pulmonary circulation of mice. © 1995 Wiley‐Liss, Inc. |
doi_str_mv | 10.1002/ar.1092410313 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77285754</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77285754</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3363-b7c84a471550e5b647d2aa89ec173118f01cf32b0ed83fbfd8ea8b055796b56f3</originalsourceid><addsrcrecordid>eNp9kM9LwzAUx4Moc06PHoWcvFWTpmmy4xB_DAaCKHgrafriMtq0Ju3G_OvN2FBPnl5e3ocP730RuqTkhhKS3iof6zTNKGGUHaFxbERCqOTHaEwIYUkq8vdTdBbCihBKszwfoZEQnFMhx-hrXoHrrbFa9bZ1uDV4rYIeauVx6JbW6R58wKrH_RLwaoj9Diuh3wA4rOo1tDtWq87W8WEhwq7C3VA3rVN-i9fghjr-RvNO0bRDAFwP7uMcnRhVB7g41Al6e7h_vXtKFs-P87vZItGM5SwphZaZygTlnAAv80xUqVJyCpoKRqk0hGrD0pJAJZkpTSVByZJwLqZ5yXPDJuh67-18-zlA6IvGBg1xWwdxmUKIVHLBswgme1D7NgQPpui8beINBSXFLutC-eI368hfHcRD2UD1Qx_CjXOxn29sDdv_ZcXs5Y_5G6GtjHQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77285754</pqid></control><display><type>article</type><title>Identification of vascular sphincters at the junction between alveolar capillaries and pulmonary venules of the mouse lung</title><source>MEDLINE</source><source>Wiley Journals</source><creator>Peáto, Mário N. D. ; Águas, Artur P. ; De SÁ, Carlos M. ; Grande, Nuno Rodrigues</creator><creatorcontrib>Peáto, Mário N. D. ; Águas, Artur P. ; De SÁ, Carlos M. ; Grande, Nuno Rodrigues</creatorcontrib><description>Background: A peculiar feature of lung circulation in the lung is the pronounced variations in blood volume observed in alveolar capillaries that occur because of the changes in the conformation of the alveolar wall that are associated with the respiratory movements. This phenomenon has led to the postulate that mechanisms of postcapillary control of blood flow are to be present in the lung vessels. In the present study we searched for microanatomical evidence of vascular sphincters in the deep lung tissue of mice, namely in alveolar capillaries and pulmonary veins.
Methods: We have used scanning electron microscopy (SEM) to examine two types of samples of normal lung tissue of CD‐1 mice: 1) vascular corrosion casts made by vascular perfusion with Mercox® resin, and 2) routinely made gold/platinum‐coated replicas of sectioned lung tissue.
Results: Careful scrutiny of the vessels of the deep lung tissue led to the identification of sphincters in alveolar capillaries. These sphincters were located at the junction between capillary and pulmonary veins. They corresponded to areas to the vascular wall showing circular swellings where a radial organization was observed, since they were made up of alternating grooves and bulges. Transmission electron microscopy showed that smooth muscle cells participated in the formation of the sphincters.
Conclusions: Our data reveal a new location for vascular sphincters in pulmonary vessels and, because these novel sphincters are located at the capillary‐vein junction, they offer a structural setting for the existence of postcapillary control of blood flow in the pulmonary circulation of mice. © 1995 Wiley‐Liss, Inc.</description><identifier>ISSN: 0003-276X</identifier><identifier>EISSN: 1097-0185</identifier><identifier>DOI: 10.1002/ar.1092410313</identifier><identifier>PMID: 7755178</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Animals ; Blood vessels ; Capillaries - anatomy & histology ; Corrosion Casting ; Corrosion casts ; Endothelium, Vascular - anatomy & histology ; Female ; Lung ; Mice ; Microscopy, Electron ; Microscopy, Electron, Scanning ; Pulmonary Alveoli - blood supply ; Scanning electron microscopy ; Vascular sphincters ; Venules - anatomy & histology</subject><ispartof>The Anatomical record, 1995-03, Vol.241 (3), p.383-390</ispartof><rights>Copyright © 1995 Wiley‐Liss, Inc.</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3363-b7c84a471550e5b647d2aa89ec173118f01cf32b0ed83fbfd8ea8b055796b56f3</citedby><cites>FETCH-LOGICAL-c3363-b7c84a471550e5b647d2aa89ec173118f01cf32b0ed83fbfd8ea8b055796b56f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Far.1092410313$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Far.1092410313$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7755178$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Peáto, Mário N. D.</creatorcontrib><creatorcontrib>Águas, Artur P.</creatorcontrib><creatorcontrib>De SÁ, Carlos M.</creatorcontrib><creatorcontrib>Grande, Nuno Rodrigues</creatorcontrib><title>Identification of vascular sphincters at the junction between alveolar capillaries and pulmonary venules of the mouse lung</title><title>The Anatomical record</title><addtitle>Anat Rec</addtitle><description>Background: A peculiar feature of lung circulation in the lung is the pronounced variations in blood volume observed in alveolar capillaries that occur because of the changes in the conformation of the alveolar wall that are associated with the respiratory movements. This phenomenon has led to the postulate that mechanisms of postcapillary control of blood flow are to be present in the lung vessels. In the present study we searched for microanatomical evidence of vascular sphincters in the deep lung tissue of mice, namely in alveolar capillaries and pulmonary veins.
Methods: We have used scanning electron microscopy (SEM) to examine two types of samples of normal lung tissue of CD‐1 mice: 1) vascular corrosion casts made by vascular perfusion with Mercox® resin, and 2) routinely made gold/platinum‐coated replicas of sectioned lung tissue.
Results: Careful scrutiny of the vessels of the deep lung tissue led to the identification of sphincters in alveolar capillaries. These sphincters were located at the junction between capillary and pulmonary veins. They corresponded to areas to the vascular wall showing circular swellings where a radial organization was observed, since they were made up of alternating grooves and bulges. Transmission electron microscopy showed that smooth muscle cells participated in the formation of the sphincters.
Conclusions: Our data reveal a new location for vascular sphincters in pulmonary vessels and, because these novel sphincters are located at the capillary‐vein junction, they offer a structural setting for the existence of postcapillary control of blood flow in the pulmonary circulation of mice. © 1995 Wiley‐Liss, Inc.</description><subject>Animals</subject><subject>Blood vessels</subject><subject>Capillaries - anatomy & histology</subject><subject>Corrosion Casting</subject><subject>Corrosion casts</subject><subject>Endothelium, Vascular - anatomy & histology</subject><subject>Female</subject><subject>Lung</subject><subject>Mice</subject><subject>Microscopy, Electron</subject><subject>Microscopy, Electron, Scanning</subject><subject>Pulmonary Alveoli - blood supply</subject><subject>Scanning electron microscopy</subject><subject>Vascular sphincters</subject><subject>Venules - anatomy & histology</subject><issn>0003-276X</issn><issn>1097-0185</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kM9LwzAUx4Moc06PHoWcvFWTpmmy4xB_DAaCKHgrafriMtq0Ju3G_OvN2FBPnl5e3ocP730RuqTkhhKS3iof6zTNKGGUHaFxbERCqOTHaEwIYUkq8vdTdBbCihBKszwfoZEQnFMhx-hrXoHrrbFa9bZ1uDV4rYIeauVx6JbW6R58wKrH_RLwaoj9Diuh3wA4rOo1tDtWq87W8WEhwq7C3VA3rVN-i9fghjr-RvNO0bRDAFwP7uMcnRhVB7g41Al6e7h_vXtKFs-P87vZItGM5SwphZaZygTlnAAv80xUqVJyCpoKRqk0hGrD0pJAJZkpTSVByZJwLqZ5yXPDJuh67-18-zlA6IvGBg1xWwdxmUKIVHLBswgme1D7NgQPpui8beINBSXFLutC-eI368hfHcRD2UD1Qx_CjXOxn29sDdv_ZcXs5Y_5G6GtjHQ</recordid><startdate>199503</startdate><enddate>199503</enddate><creator>Peáto, Mário N. D.</creator><creator>Águas, Artur P.</creator><creator>De SÁ, Carlos M.</creator><creator>Grande, Nuno Rodrigues</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199503</creationdate><title>Identification of vascular sphincters at the junction between alveolar capillaries and pulmonary venules of the mouse lung</title><author>Peáto, Mário N. D. ; Águas, Artur P. ; De SÁ, Carlos M. ; Grande, Nuno Rodrigues</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3363-b7c84a471550e5b647d2aa89ec173118f01cf32b0ed83fbfd8ea8b055796b56f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Animals</topic><topic>Blood vessels</topic><topic>Capillaries - anatomy & histology</topic><topic>Corrosion Casting</topic><topic>Corrosion casts</topic><topic>Endothelium, Vascular - anatomy & histology</topic><topic>Female</topic><topic>Lung</topic><topic>Mice</topic><topic>Microscopy, Electron</topic><topic>Microscopy, Electron, Scanning</topic><topic>Pulmonary Alveoli - blood supply</topic><topic>Scanning electron microscopy</topic><topic>Vascular sphincters</topic><topic>Venules - anatomy & histology</topic><toplevel>online_resources</toplevel><creatorcontrib>Peáto, Mário N. D.</creatorcontrib><creatorcontrib>Águas, Artur P.</creatorcontrib><creatorcontrib>De SÁ, Carlos M.</creatorcontrib><creatorcontrib>Grande, Nuno Rodrigues</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Anatomical record</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Peáto, Mário N. D.</au><au>Águas, Artur P.</au><au>De SÁ, Carlos M.</au><au>Grande, Nuno Rodrigues</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Identification of vascular sphincters at the junction between alveolar capillaries and pulmonary venules of the mouse lung</atitle><jtitle>The Anatomical record</jtitle><addtitle>Anat Rec</addtitle><date>1995-03</date><risdate>1995</risdate><volume>241</volume><issue>3</issue><spage>383</spage><epage>390</epage><pages>383-390</pages><issn>0003-276X</issn><eissn>1097-0185</eissn><abstract>Background: A peculiar feature of lung circulation in the lung is the pronounced variations in blood volume observed in alveolar capillaries that occur because of the changes in the conformation of the alveolar wall that are associated with the respiratory movements. This phenomenon has led to the postulate that mechanisms of postcapillary control of blood flow are to be present in the lung vessels. In the present study we searched for microanatomical evidence of vascular sphincters in the deep lung tissue of mice, namely in alveolar capillaries and pulmonary veins.
Methods: We have used scanning electron microscopy (SEM) to examine two types of samples of normal lung tissue of CD‐1 mice: 1) vascular corrosion casts made by vascular perfusion with Mercox® resin, and 2) routinely made gold/platinum‐coated replicas of sectioned lung tissue.
Results: Careful scrutiny of the vessels of the deep lung tissue led to the identification of sphincters in alveolar capillaries. These sphincters were located at the junction between capillary and pulmonary veins. They corresponded to areas to the vascular wall showing circular swellings where a radial organization was observed, since they were made up of alternating grooves and bulges. Transmission electron microscopy showed that smooth muscle cells participated in the formation of the sphincters.
Conclusions: Our data reveal a new location for vascular sphincters in pulmonary vessels and, because these novel sphincters are located at the capillary‐vein junction, they offer a structural setting for the existence of postcapillary control of blood flow in the pulmonary circulation of mice. © 1995 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>7755178</pmid><doi>10.1002/ar.1092410313</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-276X |
ispartof | The Anatomical record, 1995-03, Vol.241 (3), p.383-390 |
issn | 0003-276X 1097-0185 |
language | eng |
recordid | cdi_proquest_miscellaneous_77285754 |
source | MEDLINE; Wiley Journals |
subjects | Animals Blood vessels Capillaries - anatomy & histology Corrosion Casting Corrosion casts Endothelium, Vascular - anatomy & histology Female Lung Mice Microscopy, Electron Microscopy, Electron, Scanning Pulmonary Alveoli - blood supply Scanning electron microscopy Vascular sphincters Venules - anatomy & histology |
title | Identification of vascular sphincters at the junction between alveolar capillaries and pulmonary venules of the mouse lung |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T04%3A00%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Identification%20of%20vascular%20sphincters%20at%20the%20junction%20between%20alveolar%20capillaries%20and%20pulmonary%20venules%20of%20the%20mouse%20lung&rft.jtitle=The%20Anatomical%20record&rft.au=Pe%C3%A1to,%20M%C3%A1rio%20N.%20D.&rft.date=1995-03&rft.volume=241&rft.issue=3&rft.spage=383&rft.epage=390&rft.pages=383-390&rft.issn=0003-276X&rft.eissn=1097-0185&rft_id=info:doi/10.1002/ar.1092410313&rft_dat=%3Cproquest_cross%3E77285754%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77285754&rft_id=info:pmid/7755178&rfr_iscdi=true |