Determination of captopril in pharmaceutical tablets by anion-exchange HPLC using indirect photometric detection; a study in systematic method development

The development and validation of a significantly cost effective and simpler anion-exchange high performance liquid chromatorgaphic (HPLC) procedure than the compendial methods for the analysis of captopril in tablet dosage forms using indirect photometric detection is described. A low capacity anio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical and biomedical analysis 2001-04, Vol.25 (1), p.39-52
Hauptverfasser: Mirza, Tahseen, Tan, Henry S.I
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 52
container_issue 1
container_start_page 39
container_title Journal of pharmaceutical and biomedical analysis
container_volume 25
creator Mirza, Tahseen
Tan, Henry S.I
description The development and validation of a significantly cost effective and simpler anion-exchange high performance liquid chromatorgaphic (HPLC) procedure than the compendial methods for the analysis of captopril in tablet dosage forms using indirect photometric detection is described. A low capacity anion-exchange column was used with potassium phthalate as the mobile phase marker and indirect detection at 280 nm. The chromatographic conditions were optimized using the Box and Behnken factorial experimental design. The method was precise and accurate with percent recovery (±%R.S.D.) of 99.8±0.7% ( n=12) with the spiked concentrations ranging between ±30% of the assay level. Youden and Steiner's robustness test, involving seven chosen variables, showed that the method is robust. Using the developed method, commercially available captopril tablets were assayed and the results were found to be comparable with those obtained by the compendial method.
doi_str_mv 10.1016/S0731-7085(00)00462-3
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77008898</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0731708500004623</els_id><sourcerecordid>77008898</sourcerecordid><originalsourceid>FETCH-LOGICAL-c389t-437f3539562c2c3fe9273b48724d4aeb581d57b33f501f04fdbafeaff7d9785c3</originalsourceid><addsrcrecordid>eNqFkV-L1DAUxYMo7uzqR1ACgqwP1aRpmhQfRMY_KwwoqOBbSJObnUjb1CRdnK_ipzXdGdZHn-7L75xzOQehJ5S8pIS2r74SwWgliOSXhLwgpGnrit1DGyoFq-q2-XEfbe6QM3Se0k9CCKdd8xCdUVqLRnKxQX_eQYY4-klnHyYcHDZ6zmGOfsB-wvNex1EbWLI3esBZ9wPkhPsD1lPhK_ht9nq6Bnz1ZbfFS_LTdZFZH8HkIg45jJCjN9iWGLNGvMYap7zYw2qfDinDWKINLtw-2MLdwBDmEab8CD1wekjw-HQv0PcP779tr6rd54-ftm93lWGyy1XDhGOcdbytTW2Yg64WrG-kqBvbaOi5pJaLnjHHCXWkcbbXDrRzwnZCcsMu0POj7xzDrwVSVqNPBoZBTxCWpIQgRMpOFpAfQRNDShGcKjWNOh4UJWodRd2OotbGFSHqdhTFiu7pKWDpR7D_VKcVCvDsBOhUanZRT8anO66reduuNm-OFJQybjxElYyHycCxbmWD_88jfwGBBqyg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77008898</pqid></control><display><type>article</type><title>Determination of captopril in pharmaceutical tablets by anion-exchange HPLC using indirect photometric detection; a study in systematic method development</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Mirza, Tahseen ; Tan, Henry S.I</creator><creatorcontrib>Mirza, Tahseen ; Tan, Henry S.I</creatorcontrib><description>The development and validation of a significantly cost effective and simpler anion-exchange high performance liquid chromatorgaphic (HPLC) procedure than the compendial methods for the analysis of captopril in tablet dosage forms using indirect photometric detection is described. A low capacity anion-exchange column was used with potassium phthalate as the mobile phase marker and indirect detection at 280 nm. The chromatographic conditions were optimized using the Box and Behnken factorial experimental design. The method was precise and accurate with percent recovery (±%R.S.D.) of 99.8±0.7% ( n=12) with the spiked concentrations ranging between ±30% of the assay level. Youden and Steiner's robustness test, involving seven chosen variables, showed that the method is robust. Using the developed method, commercially available captopril tablets were assayed and the results were found to be comparable with those obtained by the compendial method.</description><identifier>ISSN: 0731-7085</identifier><identifier>EISSN: 1873-264X</identifier><identifier>DOI: 10.1016/S0731-7085(00)00462-3</identifier><identifier>PMID: 11274857</identifier><identifier>CODEN: JPBADA</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analysis ; Angiotensin-Converting Enzyme Inhibitors - analysis ; Biological and medical sciences ; Captopril ; Captopril - analysis ; Chemistry, Pharmaceutical ; Chromatography, High Pressure Liquid - methods ; Chromatography, Ion Exchange - methods ; General pharmacology ; Indirect photometric detection ; Ion-exchange chromatography ; Medical sciences ; Pharmaceutical tablets ; Pharmacology. Drug treatments ; Photometry - methods ; Quality Control ; Reference Standards ; Reproducibility of Results ; Tablets - chemistry</subject><ispartof>Journal of pharmaceutical and biomedical analysis, 2001-04, Vol.25 (1), p.39-52</ispartof><rights>2001 Elsevier Science B.V.</rights><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c389t-437f3539562c2c3fe9273b48724d4aeb581d57b33f501f04fdbafeaff7d9785c3</citedby><cites>FETCH-LOGICAL-c389t-437f3539562c2c3fe9273b48724d4aeb581d57b33f501f04fdbafeaff7d9785c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0731-7085(00)00462-3$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=925663$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11274857$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mirza, Tahseen</creatorcontrib><creatorcontrib>Tan, Henry S.I</creatorcontrib><title>Determination of captopril in pharmaceutical tablets by anion-exchange HPLC using indirect photometric detection; a study in systematic method development</title><title>Journal of pharmaceutical and biomedical analysis</title><addtitle>J Pharm Biomed Anal</addtitle><description>The development and validation of a significantly cost effective and simpler anion-exchange high performance liquid chromatorgaphic (HPLC) procedure than the compendial methods for the analysis of captopril in tablet dosage forms using indirect photometric detection is described. A low capacity anion-exchange column was used with potassium phthalate as the mobile phase marker and indirect detection at 280 nm. The chromatographic conditions were optimized using the Box and Behnken factorial experimental design. The method was precise and accurate with percent recovery (±%R.S.D.) of 99.8±0.7% ( n=12) with the spiked concentrations ranging between ±30% of the assay level. Youden and Steiner's robustness test, involving seven chosen variables, showed that the method is robust. Using the developed method, commercially available captopril tablets were assayed and the results were found to be comparable with those obtained by the compendial method.</description><subject>Analysis</subject><subject>Angiotensin-Converting Enzyme Inhibitors - analysis</subject><subject>Biological and medical sciences</subject><subject>Captopril</subject><subject>Captopril - analysis</subject><subject>Chemistry, Pharmaceutical</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Chromatography, Ion Exchange - methods</subject><subject>General pharmacology</subject><subject>Indirect photometric detection</subject><subject>Ion-exchange chromatography</subject><subject>Medical sciences</subject><subject>Pharmaceutical tablets</subject><subject>Pharmacology. Drug treatments</subject><subject>Photometry - methods</subject><subject>Quality Control</subject><subject>Reference Standards</subject><subject>Reproducibility of Results</subject><subject>Tablets - chemistry</subject><issn>0731-7085</issn><issn>1873-264X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkV-L1DAUxYMo7uzqR1ACgqwP1aRpmhQfRMY_KwwoqOBbSJObnUjb1CRdnK_ipzXdGdZHn-7L75xzOQehJ5S8pIS2r74SwWgliOSXhLwgpGnrit1DGyoFq-q2-XEfbe6QM3Se0k9CCKdd8xCdUVqLRnKxQX_eQYY4-klnHyYcHDZ6zmGOfsB-wvNex1EbWLI3esBZ9wPkhPsD1lPhK_ht9nq6Bnz1ZbfFS_LTdZFZH8HkIg45jJCjN9iWGLNGvMYap7zYw2qfDinDWKINLtw-2MLdwBDmEab8CD1wekjw-HQv0PcP779tr6rd54-ftm93lWGyy1XDhGOcdbytTW2Yg64WrG-kqBvbaOi5pJaLnjHHCXWkcbbXDrRzwnZCcsMu0POj7xzDrwVSVqNPBoZBTxCWpIQgRMpOFpAfQRNDShGcKjWNOh4UJWodRd2OotbGFSHqdhTFiu7pKWDpR7D_VKcVCvDsBOhUanZRT8anO66reduuNm-OFJQybjxElYyHycCxbmWD_88jfwGBBqyg</recordid><startdate>20010401</startdate><enddate>20010401</enddate><creator>Mirza, Tahseen</creator><creator>Tan, Henry S.I</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20010401</creationdate><title>Determination of captopril in pharmaceutical tablets by anion-exchange HPLC using indirect photometric detection; a study in systematic method development</title><author>Mirza, Tahseen ; Tan, Henry S.I</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c389t-437f3539562c2c3fe9273b48724d4aeb581d57b33f501f04fdbafeaff7d9785c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Analysis</topic><topic>Angiotensin-Converting Enzyme Inhibitors - analysis</topic><topic>Biological and medical sciences</topic><topic>Captopril</topic><topic>Captopril - analysis</topic><topic>Chemistry, Pharmaceutical</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Chromatography, Ion Exchange - methods</topic><topic>General pharmacology</topic><topic>Indirect photometric detection</topic><topic>Ion-exchange chromatography</topic><topic>Medical sciences</topic><topic>Pharmaceutical tablets</topic><topic>Pharmacology. Drug treatments</topic><topic>Photometry - methods</topic><topic>Quality Control</topic><topic>Reference Standards</topic><topic>Reproducibility of Results</topic><topic>Tablets - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mirza, Tahseen</creatorcontrib><creatorcontrib>Tan, Henry S.I</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of pharmaceutical and biomedical analysis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mirza, Tahseen</au><au>Tan, Henry S.I</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of captopril in pharmaceutical tablets by anion-exchange HPLC using indirect photometric detection; a study in systematic method development</atitle><jtitle>Journal of pharmaceutical and biomedical analysis</jtitle><addtitle>J Pharm Biomed Anal</addtitle><date>2001-04-01</date><risdate>2001</risdate><volume>25</volume><issue>1</issue><spage>39</spage><epage>52</epage><pages>39-52</pages><issn>0731-7085</issn><eissn>1873-264X</eissn><coden>JPBADA</coden><abstract>The development and validation of a significantly cost effective and simpler anion-exchange high performance liquid chromatorgaphic (HPLC) procedure than the compendial methods for the analysis of captopril in tablet dosage forms using indirect photometric detection is described. A low capacity anion-exchange column was used with potassium phthalate as the mobile phase marker and indirect detection at 280 nm. The chromatographic conditions were optimized using the Box and Behnken factorial experimental design. The method was precise and accurate with percent recovery (±%R.S.D.) of 99.8±0.7% ( n=12) with the spiked concentrations ranging between ±30% of the assay level. Youden and Steiner's robustness test, involving seven chosen variables, showed that the method is robust. Using the developed method, commercially available captopril tablets were assayed and the results were found to be comparable with those obtained by the compendial method.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>11274857</pmid><doi>10.1016/S0731-7085(00)00462-3</doi><tpages>14</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0731-7085
ispartof Journal of pharmaceutical and biomedical analysis, 2001-04, Vol.25 (1), p.39-52
issn 0731-7085
1873-264X
language eng
recordid cdi_proquest_miscellaneous_77008898
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Analysis
Angiotensin-Converting Enzyme Inhibitors - analysis
Biological and medical sciences
Captopril
Captopril - analysis
Chemistry, Pharmaceutical
Chromatography, High Pressure Liquid - methods
Chromatography, Ion Exchange - methods
General pharmacology
Indirect photometric detection
Ion-exchange chromatography
Medical sciences
Pharmaceutical tablets
Pharmacology. Drug treatments
Photometry - methods
Quality Control
Reference Standards
Reproducibility of Results
Tablets - chemistry
title Determination of captopril in pharmaceutical tablets by anion-exchange HPLC using indirect photometric detection; a study in systematic method development
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T10%3A55%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20captopril%20in%20pharmaceutical%20tablets%20by%20anion-exchange%20HPLC%20using%20indirect%20photometric%20detection;%20a%20study%20in%20systematic%20method%20development&rft.jtitle=Journal%20of%20pharmaceutical%20and%20biomedical%20analysis&rft.au=Mirza,%20Tahseen&rft.date=2001-04-01&rft.volume=25&rft.issue=1&rft.spage=39&rft.epage=52&rft.pages=39-52&rft.issn=0731-7085&rft.eissn=1873-264X&rft.coden=JPBADA&rft_id=info:doi/10.1016/S0731-7085(00)00462-3&rft_dat=%3Cproquest_cross%3E77008898%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77008898&rft_id=info:pmid/11274857&rft_els_id=S0731708500004623&rfr_iscdi=true