Pulsatile Flow in an End-to-Side Vascular Graft Model: Comparison of Computations With Experimental Data
Various hemodynamic factors have been implicated in vascular graft intimal hyperplasia, the major mechanism contributing to chronic failure of small-diameter grafts. However, a thorough knowledge of the graft flow field is needed in order to determine the role of hemodynamics and how these factors a...
Gespeichert in:
Veröffentlicht in: | Journal of biomechanical engineering 2001-02, Vol.123 (1), p.80-87 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 87 |
---|---|
container_issue | 1 |
container_start_page | 80 |
container_title | Journal of biomechanical engineering |
container_volume | 123 |
creator | Lei, M Giddens, D. P Jones, S. A Loth, F Bassiouny, H |
description | Various hemodynamic factors have been implicated in vascular graft intimal hyperplasia, the major mechanism contributing to chronic failure of small-diameter grafts. However, a thorough knowledge of the graft flow field is needed in order to determine the role of hemodynamics and how these factors affect the underlying biological processes. Computational fluid dynamics offers much more versatility and resolution than in vitro or in vivo methods, yet computations must be validated by careful comparison with experimental data. Whereas numerous numerical and in vitro simulations of arterial geometries have been reported, direct point-by-point comparisons of the two techniques are rare in the literature. We have conducted finite element computational analyses for a model of an end-to-side vascular graft and compared the results with experimental data obtained using laser-Doppler velocimetry. Agreement for velocity profiles is found to be good, with some clear differences near the recirculation zones during the deceleration and reverse-flow segments of the flow waveform. Wall shear stresses are determined from velocity gradients, whether by computational or experimental methods, and hence the agreement for this quantity, while still good, is less consistent than for velocity itself. From the wall shear stress numerical results, we computed four variables that have been cited in the development of intimal hyperplasia—the time-averaged wall shear stress, an oscillating shear index, and spatial and temporal wall shear stress gradients—in order to illustrate the versatility of numerical methods. We conclude that the computational approach is a valid alternative to the experimental approach for quantitative hemodynamic studies. Where differences in velocity were found by the two methods, it was generally attributed to the inability of the numerical method to model the fluid dynamics when flow conditions are destabilizing. Differences in wall shear, in the absence of destabilizing phenomena, were more likely to be caused by difficulties in calculating wall shear from relatively low resolution in vitro data. |
doi_str_mv | 10.1115/1.1336145 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77004338</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77004338</sourcerecordid><originalsourceid>FETCH-LOGICAL-a360t-c044f2eb681122ee950e18293e3785989ed4cff172742d24bf611addc9ce168b3</originalsourceid><addsrcrecordid>eNqF0M9rFDEYxvEgit1WD54FCQgFD1PzJpmZxJus2ypUFPx1DNmZN3RKJtkmGdT_3ugOevQUAh8eki8hT4BdAED7Ei5AiA5ke49soOWqUbqF-2TDQKqG9QJOyGnOt4wBKMkekhMA3veCdRty83Hx2ZbJI7308TudArWB7sLYlNh8mkakX20eFm8TvUrWFfo-juhf0W2cDzZNOQYa3Z_bUupMDJl-m8oN3f04YJpmDMV6-sYW-4g8cNZnfLyeZ-TL5e7z9m1z_eHq3fb1dWNFx0ozMCkdx32n6hs5om4ZguJaoOhVq5XGUQ7OQc97yUcu964DsOM46AGhU3txRs6Pu4cU7xbMxcxTHtB7GzAu2fQ9Y1II9V_Ia89Wa6jwxREOKeac0JlD_ZlNPw0w87u_AbP2r_bZOrrsZxz_yTV4Bc9XULNa75INw5T_Os04V6yqp0dl84zmNi4p1GZGtkxIEL8AF8mT6Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21455991</pqid></control><display><type>article</type><title>Pulsatile Flow in an End-to-Side Vascular Graft Model: Comparison of Computations With Experimental Data</title><source>MEDLINE</source><source>ASME Transactions Journals (Current)</source><creator>Lei, M ; Giddens, D. P ; Jones, S. A ; Loth, F ; Bassiouny, H</creator><creatorcontrib>Lei, M ; Giddens, D. P ; Jones, S. A ; Loth, F ; Bassiouny, H</creatorcontrib><description>Various hemodynamic factors have been implicated in vascular graft intimal hyperplasia, the major mechanism contributing to chronic failure of small-diameter grafts. However, a thorough knowledge of the graft flow field is needed in order to determine the role of hemodynamics and how these factors affect the underlying biological processes. Computational fluid dynamics offers much more versatility and resolution than in vitro or in vivo methods, yet computations must be validated by careful comparison with experimental data. Whereas numerous numerical and in vitro simulations of arterial geometries have been reported, direct point-by-point comparisons of the two techniques are rare in the literature. We have conducted finite element computational analyses for a model of an end-to-side vascular graft and compared the results with experimental data obtained using laser-Doppler velocimetry. Agreement for velocity profiles is found to be good, with some clear differences near the recirculation zones during the deceleration and reverse-flow segments of the flow waveform. Wall shear stresses are determined from velocity gradients, whether by computational or experimental methods, and hence the agreement for this quantity, while still good, is less consistent than for velocity itself. From the wall shear stress numerical results, we computed four variables that have been cited in the development of intimal hyperplasia—the time-averaged wall shear stress, an oscillating shear index, and spatial and temporal wall shear stress gradients—in order to illustrate the versatility of numerical methods. We conclude that the computational approach is a valid alternative to the experimental approach for quantitative hemodynamic studies. Where differences in velocity were found by the two methods, it was generally attributed to the inability of the numerical method to model the fluid dynamics when flow conditions are destabilizing. Differences in wall shear, in the absence of destabilizing phenomena, were more likely to be caused by difficulties in calculating wall shear from relatively low resolution in vitro data.</description><identifier>ISSN: 0148-0731</identifier><identifier>EISSN: 1528-8951</identifier><identifier>DOI: 10.1115/1.1336145</identifier><identifier>PMID: 11277306</identifier><identifier>CODEN: JBENDY</identifier><language>eng</language><publisher>New York, NY: ASME</publisher><subject>Anastomosis, Surgical ; Animals ; Arteries - physiopathology ; Arteries - surgery ; Biological and medical sciences ; Blood Flow Velocity ; Blood Vessel Prosthesis ; Computational fluid dynamics ; Computer simulation ; Dogs ; Finite element method ; Hemodynamics ; Laser Doppler velocimeters ; Laser-Doppler Flowmetry ; Mathematical models ; Medical sciences ; Models, Cardiovascular ; Oscillations ; Pulsatile Flow ; Reproducibility of Results ; Shear stress ; Stress, Mechanical ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Vascular surgery: aorta, extremities, vena cava. Surgery of the lymphatic vessels ; Wall flow</subject><ispartof>Journal of biomechanical engineering, 2001-02, Vol.123 (1), p.80-87</ispartof><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a360t-c044f2eb681122ee950e18293e3785989ed4cff172742d24bf611addc9ce168b3</citedby><cites>FETCH-LOGICAL-a360t-c044f2eb681122ee950e18293e3785989ed4cff172742d24bf611addc9ce168b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902,38497</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=902280$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11277306$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lei, M</creatorcontrib><creatorcontrib>Giddens, D. P</creatorcontrib><creatorcontrib>Jones, S. A</creatorcontrib><creatorcontrib>Loth, F</creatorcontrib><creatorcontrib>Bassiouny, H</creatorcontrib><title>Pulsatile Flow in an End-to-Side Vascular Graft Model: Comparison of Computations With Experimental Data</title><title>Journal of biomechanical engineering</title><addtitle>J Biomech Eng</addtitle><addtitle>J Biomech Eng</addtitle><description>Various hemodynamic factors have been implicated in vascular graft intimal hyperplasia, the major mechanism contributing to chronic failure of small-diameter grafts. However, a thorough knowledge of the graft flow field is needed in order to determine the role of hemodynamics and how these factors affect the underlying biological processes. Computational fluid dynamics offers much more versatility and resolution than in vitro or in vivo methods, yet computations must be validated by careful comparison with experimental data. Whereas numerous numerical and in vitro simulations of arterial geometries have been reported, direct point-by-point comparisons of the two techniques are rare in the literature. We have conducted finite element computational analyses for a model of an end-to-side vascular graft and compared the results with experimental data obtained using laser-Doppler velocimetry. Agreement for velocity profiles is found to be good, with some clear differences near the recirculation zones during the deceleration and reverse-flow segments of the flow waveform. Wall shear stresses are determined from velocity gradients, whether by computational or experimental methods, and hence the agreement for this quantity, while still good, is less consistent than for velocity itself. From the wall shear stress numerical results, we computed four variables that have been cited in the development of intimal hyperplasia—the time-averaged wall shear stress, an oscillating shear index, and spatial and temporal wall shear stress gradients—in order to illustrate the versatility of numerical methods. We conclude that the computational approach is a valid alternative to the experimental approach for quantitative hemodynamic studies. Where differences in velocity were found by the two methods, it was generally attributed to the inability of the numerical method to model the fluid dynamics when flow conditions are destabilizing. Differences in wall shear, in the absence of destabilizing phenomena, were more likely to be caused by difficulties in calculating wall shear from relatively low resolution in vitro data.</description><subject>Anastomosis, Surgical</subject><subject>Animals</subject><subject>Arteries - physiopathology</subject><subject>Arteries - surgery</subject><subject>Biological and medical sciences</subject><subject>Blood Flow Velocity</subject><subject>Blood Vessel Prosthesis</subject><subject>Computational fluid dynamics</subject><subject>Computer simulation</subject><subject>Dogs</subject><subject>Finite element method</subject><subject>Hemodynamics</subject><subject>Laser Doppler velocimeters</subject><subject>Laser-Doppler Flowmetry</subject><subject>Mathematical models</subject><subject>Medical sciences</subject><subject>Models, Cardiovascular</subject><subject>Oscillations</subject><subject>Pulsatile Flow</subject><subject>Reproducibility of Results</subject><subject>Shear stress</subject><subject>Stress, Mechanical</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Vascular surgery: aorta, extremities, vena cava. Surgery of the lymphatic vessels</subject><subject>Wall flow</subject><issn>0148-0731</issn><issn>1528-8951</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqF0M9rFDEYxvEgit1WD54FCQgFD1PzJpmZxJus2ypUFPx1DNmZN3RKJtkmGdT_3ugOevQUAh8eki8hT4BdAED7Ei5AiA5ke49soOWqUbqF-2TDQKqG9QJOyGnOt4wBKMkekhMA3veCdRty83Hx2ZbJI7308TudArWB7sLYlNh8mkakX20eFm8TvUrWFfo-juhf0W2cDzZNOQYa3Z_bUupMDJl-m8oN3f04YJpmDMV6-sYW-4g8cNZnfLyeZ-TL5e7z9m1z_eHq3fb1dWNFx0ozMCkdx32n6hs5om4ZguJaoOhVq5XGUQ7OQc97yUcu964DsOM46AGhU3txRs6Pu4cU7xbMxcxTHtB7GzAu2fQ9Y1II9V_Ia89Wa6jwxREOKeac0JlD_ZlNPw0w87u_AbP2r_bZOrrsZxz_yTV4Bc9XULNa75INw5T_Os04V6yqp0dl84zmNi4p1GZGtkxIEL8AF8mT6Q</recordid><startdate>20010201</startdate><enddate>20010201</enddate><creator>Lei, M</creator><creator>Giddens, D. P</creator><creator>Jones, S. A</creator><creator>Loth, F</creator><creator>Bassiouny, H</creator><general>ASME</general><general>American Society of Mechanical Engineers</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20010201</creationdate><title>Pulsatile Flow in an End-to-Side Vascular Graft Model: Comparison of Computations With Experimental Data</title><author>Lei, M ; Giddens, D. P ; Jones, S. A ; Loth, F ; Bassiouny, H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a360t-c044f2eb681122ee950e18293e3785989ed4cff172742d24bf611addc9ce168b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Anastomosis, Surgical</topic><topic>Animals</topic><topic>Arteries - physiopathology</topic><topic>Arteries - surgery</topic><topic>Biological and medical sciences</topic><topic>Blood Flow Velocity</topic><topic>Blood Vessel Prosthesis</topic><topic>Computational fluid dynamics</topic><topic>Computer simulation</topic><topic>Dogs</topic><topic>Finite element method</topic><topic>Hemodynamics</topic><topic>Laser Doppler velocimeters</topic><topic>Laser-Doppler Flowmetry</topic><topic>Mathematical models</topic><topic>Medical sciences</topic><topic>Models, Cardiovascular</topic><topic>Oscillations</topic><topic>Pulsatile Flow</topic><topic>Reproducibility of Results</topic><topic>Shear stress</topic><topic>Stress, Mechanical</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Vascular surgery: aorta, extremities, vena cava. Surgery of the lymphatic vessels</topic><topic>Wall flow</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lei, M</creatorcontrib><creatorcontrib>Giddens, D. P</creatorcontrib><creatorcontrib>Jones, S. A</creatorcontrib><creatorcontrib>Loth, F</creatorcontrib><creatorcontrib>Bassiouny, H</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of biomechanical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lei, M</au><au>Giddens, D. P</au><au>Jones, S. A</au><au>Loth, F</au><au>Bassiouny, H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pulsatile Flow in an End-to-Side Vascular Graft Model: Comparison of Computations With Experimental Data</atitle><jtitle>Journal of biomechanical engineering</jtitle><stitle>J Biomech Eng</stitle><addtitle>J Biomech Eng</addtitle><date>2001-02-01</date><risdate>2001</risdate><volume>123</volume><issue>1</issue><spage>80</spage><epage>87</epage><pages>80-87</pages><issn>0148-0731</issn><eissn>1528-8951</eissn><coden>JBENDY</coden><abstract>Various hemodynamic factors have been implicated in vascular graft intimal hyperplasia, the major mechanism contributing to chronic failure of small-diameter grafts. However, a thorough knowledge of the graft flow field is needed in order to determine the role of hemodynamics and how these factors affect the underlying biological processes. Computational fluid dynamics offers much more versatility and resolution than in vitro or in vivo methods, yet computations must be validated by careful comparison with experimental data. Whereas numerous numerical and in vitro simulations of arterial geometries have been reported, direct point-by-point comparisons of the two techniques are rare in the literature. We have conducted finite element computational analyses for a model of an end-to-side vascular graft and compared the results with experimental data obtained using laser-Doppler velocimetry. Agreement for velocity profiles is found to be good, with some clear differences near the recirculation zones during the deceleration and reverse-flow segments of the flow waveform. Wall shear stresses are determined from velocity gradients, whether by computational or experimental methods, and hence the agreement for this quantity, while still good, is less consistent than for velocity itself. From the wall shear stress numerical results, we computed four variables that have been cited in the development of intimal hyperplasia—the time-averaged wall shear stress, an oscillating shear index, and spatial and temporal wall shear stress gradients—in order to illustrate the versatility of numerical methods. We conclude that the computational approach is a valid alternative to the experimental approach for quantitative hemodynamic studies. Where differences in velocity were found by the two methods, it was generally attributed to the inability of the numerical method to model the fluid dynamics when flow conditions are destabilizing. Differences in wall shear, in the absence of destabilizing phenomena, were more likely to be caused by difficulties in calculating wall shear from relatively low resolution in vitro data.</abstract><cop>New York, NY</cop><pub>ASME</pub><pmid>11277306</pmid><doi>10.1115/1.1336145</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0148-0731 |
ispartof | Journal of biomechanical engineering, 2001-02, Vol.123 (1), p.80-87 |
issn | 0148-0731 1528-8951 |
language | eng |
recordid | cdi_proquest_miscellaneous_77004338 |
source | MEDLINE; ASME Transactions Journals (Current) |
subjects | Anastomosis, Surgical Animals Arteries - physiopathology Arteries - surgery Biological and medical sciences Blood Flow Velocity Blood Vessel Prosthesis Computational fluid dynamics Computer simulation Dogs Finite element method Hemodynamics Laser Doppler velocimeters Laser-Doppler Flowmetry Mathematical models Medical sciences Models, Cardiovascular Oscillations Pulsatile Flow Reproducibility of Results Shear stress Stress, Mechanical Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Vascular surgery: aorta, extremities, vena cava. Surgery of the lymphatic vessels Wall flow |
title | Pulsatile Flow in an End-to-Side Vascular Graft Model: Comparison of Computations With Experimental Data |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T22%3A42%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pulsatile%20Flow%20in%20an%20End-to-Side%20Vascular%20Graft%20Model:%20Comparison%20of%20Computations%20With%20Experimental%20Data&rft.jtitle=Journal%20of%20biomechanical%20engineering&rft.au=Lei,%20M&rft.date=2001-02-01&rft.volume=123&rft.issue=1&rft.spage=80&rft.epage=87&rft.pages=80-87&rft.issn=0148-0731&rft.eissn=1528-8951&rft.coden=JBENDY&rft_id=info:doi/10.1115/1.1336145&rft_dat=%3Cproquest_cross%3E77004338%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=21455991&rft_id=info:pmid/11277306&rfr_iscdi=true |